Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

Similar documents
Zone Cabling & Wireless Enclosures

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

CONSTRUCTION MANUAL PART 4

Applications and Features

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Weatherproof 14" x 12" x 7" Enclosure with 110 VAC Mounting Plate, Cooling Fan and Heater. Model: NB HF. Applications and Features

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION ELECTRICAL IDENTIFICATION

Access Point Mounting Instructions

SECTION AIR DUCT ACCESSORIES

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

TABLE OF CONTENTS DIVISION 21- FIRE SUPPRESSION PAGES SECTION WATER BASED FIRE PROTECTION SYSTEMS... 5

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

Professional Wi-Fi Installation Solutions

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

Two (2) Side Rail Cable Tray

PART GENERAL 1.01 SECTION INCLUDES

Gas Station & C Store SECTION CWM Job No

SECTION INTRUSION DETECTION

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

J-PRO TM Cable Support System

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Telecommunications Survey

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

B-LINE SERIES. Product brochure. Firestop

SECTION CONVECTION HEATING AND COOLING UNITS

EcoAisle Thermal Containment System

SECTION DOMESTIC WATER PUMPS

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Union County Vocational - Technical Schools Scotch Plains, New Jersey

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

ARCHITECTURAL SPECIFICATIONS

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Standard Product. Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

B. Section Identification for Fire Suppression Piping and Equipment.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Vertical Wall-Mount Server Rack - Solid Steel - 6U

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

SECTION NURSE CALL SYSTEM

2 PREPARE THE OPENING

5900 SERIES Low Energy Power Operator

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

Innovative POWER Solutions

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION ELECTRICAL GENERAL PROVISIONS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES

PowerWave 2 Busway System

Architectural Specification Sheet

CABINET PARTS For Models: KSRP25QDWH01, KSRP25QDAL01, KSRP25QDBL01 (White) (Almond) (Black)

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION (15820) - AIR DUCT ACCESSORIES

5900 Series X-in Low Energy Power Operator

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

SECTION FIRE-SUPPRESSION STANDPIPES

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

SPACE TYPE: JUDICIAL CHAMBER

Elements Headwall System (P2008A)

SECTION INTERIOR LIGHTING

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems

Oberon Professional WiFi Installation Solutions for Cisco Wireless Access Points

HR Powder Feed Hopper

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

AV equipment racks for residential installations

Architect s Specification Guideline:

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

DESIGN & CONSTRUCTION GUIDELINES

SECTION INTRUSION DETECTION SYSTEM

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

SECTION FAN COIL UNITS

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

SECTION Overhead Coiling Doors

Steel Casework Acid Storage

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Transcription:

PART 1 GENERAL 1.1 WORK INCLUDED Section 27 11 00 COMMUNICATION EQUIPMENT ROOM FITTINGS Section 27 11 16 Communications Cabinets, Racks, Frames and Enclosures A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This section includes the minimum requirements for ceiling-mounted, floormounted and wall-mounted zone cabling and wireless enclosures for use as consolidation point enclosures, telecommunications enclosures, or wireless access point enclosures outside of communications equipment rooms. B. Included in this section are the minimum composition requirements and installation methods for the following: 1. Enclosures, ceiling-mounted. 2. Enclosures, floor-mounted. 3. Enclosures, wall-mounted. 1.3 QUALITY ASSURANCE A. All cable and equipment shall be installed in a neat and workmanlike manner. All methods of construction that are not specifically described or indicated in the contract documents shall be subject to the control and approval of the Owner or Owner Representative. Equipment and materials shall be of the quality and manufacture indicated. The equipment specified is based upon the acceptable manufacturers listed. Where approved equal is stated, equipment shall be equivalent in every way to that of the equipment specified and subject to approval. B. Strictly adhere to all Building Industry Consulting Service International (BICSI), Electronic Industries Alliance (EIA) and Telecommunications Industry Association (TIA) recommended installation practices when installing communications/data cabling. C. Material and work specified herein shall comply with the applicable requirements of: 1. ANSI/TIA/EIA 568-B Commercial Building Telecommunications Cabling Standard, 2000-2004 2. TIA 569-B Commercial Building Standard for Telecommunications Pathways and Spaces, 2004 REQUIREMENTS 270510-1 Communication Equipment Rooms

3. ANSI/TIA/EIA 606-A Administration Standard for the Telecommunications Infrastructure of Commercial Buildings, 2002 4. ANSI-J-STD 607-A Joint Standard for Commercial Building Grounding (Earthing) and Bonding Requirements for Telecommunications, 2002 5. NFPA 70 National Electric Code, 2005 6. BICSI Telecommunications Distribution Methods Manual, 10 th Edition, 2003 1.4 SUBMITTALS A. Provide product data for the following: 1. Manufacturers data sheets/cut sheets, specifications and installation instructions for all products (submit with bid). PART 2 PRODUCTS 1.0 Consolidation Point Enclosures A. Consolidation Point Enclosures, Ceiling-Mounted 1. Ceiling-mounted consolidation point enclosures shall be manufactured from sheet aluminum,.06 thick. 2. Each enclosure will be rectangular in shape sized to replace a single 2 x 4 drop ceiling tile, or square in shape sized to replace a single 2 x 2 drop ceiling tile, as specified below. 3. When installed into the ceiling, the body of the enclosure will be located above the drop ceiling, suspended from the structural ceiling by threaded rods. The enclosure will include brackets for attaching threaded rods. One side of the enclosure will be flush with the drop ceiling. An access door on the flush surface will open into the work area below the drop ceiling providing access to equipment within the enclosure. 4. The access door will be fully hinged and will latch closed. On the larger 2 x 4 model, the access door will open slowly using pneumatic assist brackets. When the access door is open, the interior of the enclosure (usable space) will be no less than 10-1/2 deep. The outside of the access door will be recessed, allowing the ceiling tile to be inserted over the door to help disguise the enclosure when the access door is closed. The manufacturer will sell a compatible keyed lock set as a separate accessory. 5. The enclosure will include one or two removable support brackets for block-terminating hardware or for 19 EIA patch panels, as specified below. The brackets will be designed to attach to the access door and/or to the enclosure. REQUIREMENTS 270510-2 Communication Equipment Rooms

6. Brackets for block terminating hardware will be removable flat metal panels with a minimum ½ standoff, each capable of supporting two 300- pair 110D-style termination blocks side-by-side. Approximate usable mounting surface is 19-1/2 by 13-1/2. 7. Brackets for 19 EIA patch panels will provide a minimum of four rackmount spaces (RMU) for equipment. Equipment mounting holes will be EIA-310-D compliant with threaded #12-24 inserts spaced on 1-1/4 (wide) vertical centers. The manufacturer will sell compatible equipmentmounting screws as a separate accessory. 8. The enclosure will have a minimum of two cable access ports located on the sides of the enclosure. The ports will include approved fire-rated foam sealing kits. Cable tie points for securing cables will be located within the enclosure. The manufacturer will sell compatible cable management straps as a separate accessory. 9. Finish shall be epoxy-polyester hybrid powder coat (paint) in the color(s) specified below. Cable ports and mounting panels will be mill finish. 10. The enclosure shall be delivered fully assembled. 11. Load bearing capacity for the 2 x 4 enclosure will be 85 pounds. The access door will be capable of supporting 50 pounds of the total 85- pound load. Load bearing capacity for the 2 x 2 enclosure will be 70 pounds. The access door will be capable of supporting 20 pounds of the total 70-pound load. Load bearing capacity will be stated in the manufacturer s product literature. 12. The enclosure will be UL Listed for use within a plenum space. UL Listing will be stated in the manufacturer s product literature. 13. Design Make: Ceiling-Mounted Consolidation Point Enclosures Part Number A1222-LP, Ceiling Enclosure, 2 x 2, 12 deep, with (1) removable mounting panel for block terminating hardware, White. UL Listed. Part Number A1224-LP, Ceiling Enclosure, 2 x 4, 12 deep, with (2) removable mounting panels for block terminating hardware, White. UL Listed. Part Number A1222-PP, Ceiling Enclosure, 2 x 2, 12 deep, with (1) removable 19 EIA x 4RMU equipment-mounting bracket for patch panels, White. UL Listed. Part Number A1224-PP, Ceiling Enclosure, 2 x 4, 12 deep, with (2) removable 19 EIA x 4RMU equipment-mounting brackets for patch panels, White. UL Listed. B. Consolidation Point Enclosures, Floor-Mounted 0. Floor-mounted consolidation point enclosures shall be manufactured from sheet aluminum,.06 thick. REQUIREMENTS 270510-3 Communication Equipment Rooms

0. Each enclosure will be square in shape and sized to fit under a single 2 x 2 raised floor tile. 0. When installed into the floor, the body of the enclosure will be located below the raised floor in the space between the raised floor tiles and the structural floor. The depth of the enclosure will not exceed the height of this space. The top of the enclosure will be flush with the raised floor. When necessary, the enclosure will be supported from the raised floor pedestals with included installation hardware. The raised floor tile will act as the cover for the enclosure. 0. The enclosure will include one or two 19 EIA equipment-mounting brackets for attaching patch panels into the enclosure, as specified below. The brackets will provide a minimum of two rack-mount spaces (RMU) for equipment. Equipment mounting holes will be EIA-310-D compliant and threaded #12-24 on 1-1/4 (wide) vertical centers. The manufacturer will sell compatible equipment-mounting screws as a separate accessory. 0. The enclosure will have a minimum of four cable access ports located on the sides of the enclosure. The ports will include approved fire-rated foam sealing kits. Cable tie points for securing cables will be located within the enclosure. The manufacturer will sell compatible cable management straps as a separate accessory. 0. Finish shall be mill finish. 0. The enclosure shall be delivered fully assembled. 0. The enclosure will be UL Listed for use within a plenum space. UL Listing will be stated in the manufacturer s product literature. 0. Design Make: Floor-Mounted Consolidation Point Enclosures Part Number A0222-RF, Raised Floor Enclosure, 2 x 2, 2 deep, with (2) pivoting 19 EIA x 1RMU equipment-mounting brackets for patch panels, mill finish. UL Listed. Note: A0222-RF does not include raised floor mounting brackets (P/N RF-BRACKET). Part Number A0422-RF, Raised Floor Enclosure, 2 x 2, 4 deep, with (2) pivoting 19 EIA x 1RMU equipment-mounting brackets for patch panels, mill finish. UL Listed. Part Number A0622-RF, Raised Floor Enclosure, 2 x 2, 6 deep, with (2) pivoting 19 EIA x 2RMU equipment-mounting brackets for patch panels, mill finish. UL Listed. Part Number A0822-RF, Raised Floor Enclosure, 2 x 2, 8 deep, with (2) pivoting 19 EIA x 4RMU equipment-mounting brackets for patch panels, mill finish. UL Listed. Part Number A1422-RF, Raised Floor Enclosure, 2 x 2, 14 deep, with (1) fixed 19 EIA x 11RMU equipment-mounting bracket for patch panels, mill finish. UL Listed. REQUIREMENTS 270510-4 Communication Equipment Rooms

Part Number A0822-RF-F, Raised Floor Enclosure, 2 x 2, 8 deep, with (1) fixed 19 EIA x 4RMU equipment-mounting bracket (removable) for fiber enclosures, mill finish. UL Listed. C. Equipment-Mounting Hardware for Ceiling-Mounted Enclosures: 1. Provide equipment-mounting hardware, if required, to attach equipment to the threaded equipment mounting rails in the enclosure. 2. Equipment mounting hardware will be combination pan head, pilot point mounting screws, threaded #12-24, and 5/8 long. 3. Design Make: Equipment Mounting Hardware Part Number 40605-001, Hardware Kit for Threaded Mounting Rails, 12-24 Screws, Package of 50, Zinc. 2.0 Telecommunications Enclosures A. Telecommunications Enclosures, Ceiling-Mounted 1. Ceiling-mounted telecommunications enclosures shall be manufactured from sheet aluminum,.06 thick. 2. Each enclosure will be rectangular in shape sized to replace a single 2 x 4 drop ceiling tile, or square in shape sized to replace a single 2 x 2 drop ceiling tile, as specified below. 3. When installed into the ceiling, the body of the enclosure will be located above the drop ceiling, suspended from the structural ceiling by threaded rods. The enclosure will include brackets for attaching threaded rods. One side of the enclosure will be flush with the drop ceiling. An access door on the flush surface will open into the work area below the drop ceiling providing access to equipment within the enclosure. 4. The access door will be fully hinged and will latch closed. On the larger 2 x 4 model, the access door will open slowly using pneumatic assist brackets. When the access door is open, the interior of the enclosure (usable space) will be no less than 10-1/2 deep. The outside of the access door will be recessed, allowing the ceiling tile to be inserted over the door to help disguise the enclosure when the access door is closed. The manufacturer will sell a compatible keyed lock set as a separate accessory. 5. The enclosure will include one or two pairs of equipment mounting brackets for 19 EIA equipment (patch panels and network switches). The brackets will be designed to attach to the access door and/or the enclosure. Each pair of brackets will provide four rack-mount spaces (RMU) for equipment. Equipment mounting holes will be EIA-310-D compliant with threaded #12-24 inserts spaced on 1-1/4 (wide) vertical centers. The manufacturer will sell compatible equipment-mounting screws as a separate accessory. 6. The enclosure will have a minimum of two cable access ports located on the sides of the enclosure and opposite the hinge side of the enclosure. The REQUIREMENTS 270510-5 Communication Equipment Rooms

ports will include approved fire-rated foam sealing kits. Cable tie points for securing cables will be located within the enclosure. The manufacturer will sell compatible cable management straps as a separate accessory. 7. The enclosure will include one or two ventilation fans, as specified below. The access door will be vented. Air will enter the enclosure through vents in the access door. The fan(s) will expel air from the enclosure through the vents in the access door. Each fan will include a 115 VAC to DC power transformer. 8. The enclosure will have one or two integrated junction boxes, as specified below. Each junction box will be sized to accept two duplex receptacles each. Each junction box will be pre-punched with a ¾ knockout for conduit. 9. The enclosure will have a bonding point consisting of two threaded studs spaced 5/8 apart for a two-hole compression style lug. The manufacturer will sell a compatible lug as a separate accessory. 10. Finish shall be epoxy-polyester hybrid powder coat (paint) in the color(s) specified below. Cable ports and mounting panels will be mill finish. 11. The enclosure shall be delivered fully assembled. 12. Load bearing capacity for the 2 x 4 enclosure will be 85 pounds. The access door will be capable of supporting 50 pounds of the total 85-pound load. Load bearing capacity for the 2 x 2 enclosure will be 70 pounds. The access door will be capable of supporting 20 pounds of the total 70-pound load. Load bearing capacity will be stated in the manufacturer s product literature. 13. The enclosure will be UL Listed for use within a plenum space. UL Listing will be stated in the manufacturer s product literature. 14. Design Make: Ceiling-Mounted Telecommunications Enclosures Part Number A1222-HR, Ceiling Enclosure, 2 x 2, 12 deep, with (1) removable 19 EIA x 4RMU equipment-mounting bracket, one ventilation fan, one electrical junction box, and bonding point, White. Part Number A1224-HR, Ceiling Enclosure, 2 x 4, 12 deep, with (2) removable 19 EIA x 4RMU equipment-mounting brackets, two ventilation fans, two electrical junction boxes, and bonding point, White. B. Telecommunications Enclosures, Floor-Mounted 0. Floor-mounted telecommunications enclosures shall be manufactured from sheet aluminum,.06 thick. 0. Each enclosure will be square in shape and sized to fit under a single 2 x 2 raised floor tile. 0. When installed into the floor, the body of the enclosure will be located below the raised floor in the space between the raised floor tiles and the structural floor. The depth of the enclosure will not exceed the height of REQUIREMENTS 270510-6 Communication Equipment Rooms

this space. The top of the enclosure will be flush with the raised floor. When necessary, the enclosure will be supported from the raised floor pedestals with included installation hardware. The raised floor tile will act as the cover for the enclosure. 0. The enclosure will include two 19 EIA equipment-mounting brackets for attaching patch panels and network switches into the enclosure. The brackets will be attached to a lift-out tray that rests completely inside the enclosure. The brackets will provide four rack-mount spaces (RMU) for patch panels and two rack-mount spaces for equipment. Equipment must be less than 14 deep. Equipment mounting holes will be EIA-310-D compliant and threaded #12-24 on 1-1/4 (wide) vertical centers. The manufacturer will sell compatible equipment-mounting screws as a separate accessory. 0. The enclosure will have a minimum of two cable access ports located on the sides of the enclosure. The ports will include approved fire-rated foam sealing kits. Cable tie points for securing cables will be located within the enclosure. The manufacturer will sell compatible cable management straps as a separate accessory. 0. The enclosure will include one ventilation fan. Air will enter the enclosure through a vent on the side opposite the fan. The fan will expels air through a vent on the side of the enclosure. The fan will include a 115 VAC to DC power transformer. 0. The enclosure will include a junction box punched to accept one duplex receptacle. 0. The enclosure will have a bonding point consisting of two threaded studs spaced 5/8 apart for a two-hole compression style lug. The manufacturer will sell a compatible lug as a separate accessory. 0. Finish shall be mill finish. 0. The enclosure shall be delivered fully assembled. 0. The enclosure will be UL Listed for use within a plenum space. UL Listing will be stated in the manufacturer s product literature. 0. Design Make: Floor-Mounted Telecommunications Enclosure Part Number A1411-RF-HR, Raised Floor Enclosure, 2 x 2, 14 deep, with (1) removable 19 EIA x 6RMU equipment-mounting tray, one ventilation fan, one electrical junction box, and bonding point, mill finish. UL Listed. C. Equipment-Mounting Hardware for Ceiling-Mounted Enclosures: 0. Provide equipment-mounting hardware, if required, to attach equipment to the threaded equipment mounting rails in the enclosure. REQUIREMENTS 270510-7 Communication Equipment Rooms

0. Equipment mounting hardware will be combination pan head, pilot point mounting screws, threaded #12-24, and 5/8 long. 0. Design Make: Equipment Mounting Hardware Part Number 40605-001, Hardware Kit for Threaded Mounting Rails, 12-24 Screws, Package of 50, Zinc. 3.0 Wireless Enclosures A. Wireless Enclosures, Ceiling-Mounted (AAT-CAP) 0. Ceiling-mounted wireless enclosures shall be manufactured from sheet aluminum,.06 thick. 0. Each enclosure will be rectangular in shape sized to fit within a single 2 x 2 drop ceiling tile, as specified below. 0. When installed into the ceiling, the body of the enclosure will be located above the drop ceiling supported from the ceiling tile support grid with included support brackets. One side of the enclosure will be flush with the drop ceiling. An access door on the flush surface will open into the work area below the drop ceiling providing access to equipment within the enclosure. 0. The access door will be fully hinged and will lock in the closed position. The access door will have an interchangeable (removable) faceplate. Faceplates will be punched with a slot and/or hole pattern to allow the antennas of wireless access point to extend below the enclosure. The wireless access point will be secured to the door with an adjustable bracket included with the enclosure, straps or hardware. The manufacturer will sell several styles of compatible faceplates as separate accessories. 0. The enclosure will have a single cable access port located on the side of the enclosure and opposite the hinge side of the access door. The ports will include approved fire-rated foam sealing kits. Cable tie points for securing cables will be located within the enclosure and on the access door. The manufacturer will sell compatible cable management straps as a separate accessory. 0. The enclosure will have an optional integrated junction box sized to accept two duplex receptacles. The junction box will be pre-punched with a 7/8 knockout for trade size ½ conduit. 0. Enclosures with the optional integrated junction box will have a bonding point consisting of two threaded studs spaced 5/8 apart for a two-hole compression style lug. The manufacturer will sell a compatible lug as a separate accessory. 0. Finish shall be epoxy-polyester hybrid powder coat (paint) in the color(s) specified below. Cable ports and mounting brackets will be mill finish. REQUIREMENTS 270510-8 Communication Equipment Rooms

0. The enclosure shall be delivered fully assembled. Access doors will be sold separately or included in a kit with the enclosure. 0. The enclosure will be UL Listed for use within a plenum space. UL Listing will be stated in the manufacturer s product literature. 0. Design Make: Ceiling-Mounted Wireless Enclosures Part Number AAT-CAP, Wireless Enclosure, 14-1/2 wide by 12 long, 10 deep, no faceplate, no electrical junction box, no bonding point, White. UL Listed. Part Number AAT-CAP-10-P, Wireless Enclosure, 14-1/2 wide by 12 long, 10 deep, no faceplate, electrical junction box, bonding point, White. UL Listed. Part Number AAT-CAP-S, Wireless Enclosure, 14-1/2 wide by 12 long, 5 deep, no faceplate, no electrical junction box, no bonding point, White. UL Listed. Part Number AAT-CAP-00, Blank faceplate (no holes), White. Part Number AAT-CAP-UNI, Universal faceplate (one large slot with brushed cover), White. Part Number AAT-CAP-35, Faceplate for Cisco Aironet 350 wireless access point or bridge, White. Part Number AAT-CAP-11, Faceplate for Cisco Aironet 1100 wireless access point, White. Part Number AAT-CAP-12, Faceplate for Cisco Aironet 1200 wireless access point, White. Note: Cisco Aironet 1100 will not fit inside an AAT-CAP-S enclosure. Use faceplate AAT- CAP-11 with the AAT-CAP enclosure. Cisco and Aironet are registered trademarks of Cisco Systems, Inc. Part Number AAT-CAP-00-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 10 deep, with (1) removable blank faceplate (no holes), no equipment-mounting bracket, no electrical junction box, and no bonding point, White. Part Number AAT-CAP-UNI-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 10 deep, with (1) removable universal faceplate (brushed slot), equipment-mounting bracket, no electrical junction box, and no bonding point, White. Part Number AAT-CAP-35-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 10 deep, with (1) removable faceplate optimized for a Cisco Aironet 350 Wireless Access Point, with equipment-mounting bracket, no electrical junction box, and no bonding point, White. Part Number AAT-CAP-11-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 10 deep, with (1) removable faceplate optimized for a Cisco Aironet 1100 Wireless Access Point, no equipment-mounting bracket, no electrical junction box, and no bonding point, White. Part Number AAT-CAP-12-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 10 deep, with (1) removable faceplate optimized for a Cisco Aironet 1200 Wireless Access Point, with equipment-mounting bracket, no electrical junction box, and no bonding point, White. REQUIREMENTS 270510-9 Communication Equipment Rooms

Part Number AAT-CAP-S-00-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 5 deep, with (1) removable blank faceplate (no holes), no equipment-mounting bracket, no electrical junction box, and no bonding point, White. Part Number AAT-CAP-S-UNI-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 5 deep, with (1) removable universal faceplate (brushed slot), equipment-mounting bracket, no electrical junction box, and no bonding point, White. Part Number AAT-CAP-S-35-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 5 deep, with (1) removable faceplate optimized for a Cisco Aironet 350 Wireless Access Point, with equipment-mounting bracket, no electrical junction box, and no bonding point, White. Part Number AAT-CAP-S-12-KIT, Wireless Enclosure, 14-1/2 wide by 12 long, 5 deep, with (1) removable faceplate optimized for a Cisco Aironet 1200 Wireless Access Point, with equipment-mounting bracket, no electrical junction box, and no bonding point, White. B. Wireless Enclosures, Ceiling-Mounted (AAT-ACE-DOME) 0. Ceiling-mounted wireless enclosures shall be manufactured from sheet aluminum,.06 thick. 0. Each enclosure will be rectangular in shape sized to replace a single 2 x 2 drop ceiling tile, as specified below. 0. When installed into the ceiling, the body of the enclosure will be located above the drop ceiling supported from the structural ceiling by threaded rods. The enclosure will include brackets for attaching threaded rods. One side of the enclosure will be flush with the drop ceiling. An access door on the flush surface will open into the work area below the drop ceiling providing access to equipment within the enclosure. 0. The access door will be fully hinged and will lock in the closed position. The access door will have a 14 diameter half sphere dome located in the center of the door. The sphere will project into the workspace approximately 6-1/2 below the drop ceiling tiles. The sphere will be opaque plastic, white in color. 0. The wireless access point will be attached to a removable 6-7/8 by 8-7/8 back plate. The back plate will attach to the back of the enclosure on standoffs so that the wireless access point is suspended within the half sphere dome at the center of the access door. There are no openings in the enclosure or the door for antennas to project outside of the enclosure. 0. The enclosure will have a single cable access port located on the side of the enclosure. The port will include an approved fire-rated foam sealing kit. Cable tie points for securing cables will be located within the enclosure. The manufacturer will sell compatible cable management straps as a separate accessory. 0. Finish shall be epoxy-polyester hybrid powder coat (paint) in the color(s) specified below. Cable port and threaded rod brackets are mill finish. Back plate and dome are white plastic. REQUIREMENTS 270510-10 Communication Equipment Rooms

0. The enclosure shall be delivered fully assembled. 0. The enclosure will be UL Listed for use within a plenum space. UL Listing will be stated in the manufacturer s product literature. 0. Design Make: Ceiling-Mounted Wireless Enclosures Part Number AAT-ACE-DOME, Wireless Enclosure, 2 x 2, 3 deep, with 14 diameter by 6-1/2 high dome, and (1) removable 6-7/8 x 8-7/8 equipment-mounting back plate, White. UL Listed. C. Wireless Enclosures, Wall-Mounted, Outdoor/Industrial/Warehouse Use (AAT- MWME-P, AAT-WMESG-P, AAT-WME-P) 0. Wall-mounted wireless enclosures shall be manufactured from fiberglass-reinforced polyester. 0. Each enclosure will be rectangular in shape. The enclosures will be sized as specified below. 0. The access door will be fully hinged and will latch in the closed position. Latches will accept padlocks to secure the enclosure. Access doors may be solid or have a tinted window, as specified below. 0. The enclosure will include a removable back plate, sized as specified below. The back plate will attach to the back of the enclosure. There are no openings in the enclosure or the door for antennas to project outside of the enclosure. 0. The enclosure will have no cable access ports. All penetrations will be made in the field by the installer. The enclosure will be NEMA rated: NEMA 1, NEMA 3R, NEMA 4X, NEMA 6P, and NEMA 12. The enclosure may be used outdoors or in a light industrial/warehouse environment. The enclosure should not be submerged. 0. Finish is gray. Optional tinted window for door is bronze acrylic. 0. The enclosure shall be delivered fully assembled. 0. The enclosure will be UL Listed for use within a plenum space. UL Listing will be stated in the manufacturer s product literature. 0. Design Make: Ceiling-Mounted Wireless Enclosures Part Number AAT-WMESG-P, Wireless Enclosure, Wall Mounted, with tinted door window, 15-1/2 high by 13-1/2 wide by 6 deep, 5 deep interior, 13-1/4 long by 11-1/8 wide removable back plate, Gray. REQUIREMENTS 270510-11 Communication Equipment Rooms

Part Number AAT-WME-P, Wireless Enclosure, Wall Mounted, with solid door, 15-1/2 high by 13-1/2 wide by 6 deep, 5 deep interior, 13-1/4 long by 11-1/8 wide removable back plate, Gray. Part Number AAT-MWME-P, Wireless Enclosure, Wall Mounted, with solid door, 11-1/2 high by 9-1/2 wide by 4-1/2 deep, 3 deep interior, 8-7/8 long by 6-7/8 wide removable back plate, Gray. PART 3 EXECUTION 3.1 INSTALLATION A. Ceiling Enclosures 1. Attach the enclosure to the ceiling so that the access door can be opened fully without obstruction by other building, storage or architectural components. Locate the enclosure near the center of the cabling zone. The enclosure should be positioned so that access to the enclosure does not require movement of furnishings and so that disturbance in the workspace is minimized. The ceiling space must provide sufficient height for the enclosure. Access to the enclosure through surrounding ceiling tiles should also be considered when selecting location of the enclosure. 2. Follow the manufacturer s installation instructions when securing the enclosure to the ceiling and installing equipment. The enclosure must be attached to building structure with threaded rods and cannot be supported by the drop ceiling grid (t-bars) or tiles unless the enclosure is provided with brackets specifically for this purpose. Use 3/8 hardware or appropriate hardware as defined by local code or the authority having jurisdiction to secure the enclosure to building structure. Auxiliary framing may be required to position the enclosure as desired. The body of the enclosure should be above the drop ceiling tiles. The access door of the enclosure should be flush with the drop ceiling grid. Seal the cable port(s) with the included foam sealing kit(s) per instructions in plenum ceilings used as air handling spaces. Note: Seismic installations require additional bracing of enclosures and overhead cable runways to building structure as advised by and certified by a licensed structural engineer. B. Raised-Floor Enclosures 0. Select a position for the raised floor enclosure where the enclosure (tile over the enclosure) can be opened fully without obstruction by other building, storage or architectural components. Location should be central within the cabling zone. The enclosure should be positioned so that access to the enclosure does not require movement of furnishings and so that disturbance in the workspace is minimized. The floor space must provide sufficient depth for the enclosure. Access to the enclosure through surrounding raised floor tiles should also be considered when selecting location of the enclosure. 0. Follow the manufacturer s installation instructions when securing the enclosure to the floor or raised floor pedestals and installing equipment. The body of the enclosure should be below the raised floor tiles. The raised floor tile above the enclosure serves as the cover for the enclosure and should be REQUIREMENTS 270510-12 Communication Equipment Rooms

flush with the floor. Seal the cable port(s) with the included foam sealing kit(s) per instructions in raised floor plenums used as air handling spaces. Note: Seismic installations require additional bracing of enclosures to building structure as advised by and certified by a licensed structural engineer. Wall-Mount Enclosures 1. Select a location for the wall-mount enclosure where the enclosure can be opened fully without obstruction by other building, storage or architectural components. Location should be central within the cabling zone. The enclosure should be positioned so that access to the enclosure does not require movement of furnishings and so that disturbance in the workspace is minimized. 2. Follow the manufacturer s installation instructions when securing the enclosure to the wall and installing equipment. REQUIREMENTS 270510-13 Communication Equipment Rooms