High Speed Fine Pitch Connectors (MICTOR, MICTOR SB, Micro-Strip and STEP-Z Interconnection Systems)

Similar documents
Z-PACK TinMan 85 ohm Connector Overview

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

Quick Reference Guide.050 Centerline Micro-MaTch Connector Series

Introduction. Technical Features

Battery Interconnects

Inverted Through Board Surface

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Introducing Corcom DB Series

Introducing SlimSeal SSL Connector

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

Level V IDC Connectors,.125 x.125 [3.18 x 3.18] Centerline

Introducing Hermaphroditic Blade and Receptacle Connector

Contacts for Econoseal III Connectors Series.070 (1.8 mm) and Series.250 (6.3 mm)

Quick Reference Guide: Connectors for Mobile Devices

March 2002 Rev O

Universal Retention Modules 02 MAR 10 Rev A

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Waterproof Circular Connectors

G4 Pulsed Fiber Laser

SM CONNECTOR. 1Certified LR R Specifications. Standards. 2.5mm pitch/disconnectable Crimp style wire-to-wire connectors

Introducing Inverted SMT Thru Board Connector

Proximity Sensor Components

CATEGORY 6A FTP RJ45 SOLUTION

Solutions for AdvancedTCA, AdvancedTCA 300, MicroTCA, and AdvancedMC Standards. RoHS. Ready

onlinecomponents.com

Technical Manual Ionisation Chamber MUSIC80

Telecom Fuses. Benefits. Features. Applications

Total compliance. Unmatched safety. Proven reliability.

PlanarMag Product Technology

Micropower Omnipolar Digital Hall-Effect Sensor ICs

General Specifications. Small size Fast 500µs response time Cable or quick-disconnect options 11 28V DC Operating Voltage Red output LED indicator

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Products for Mobile Equipment. RoHS. Ready

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

NG4access ODF Platform Standard Chassis Installation Manual

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

NT DUAL CHANNEL DISPLAY. User Guide

AMP SUPERSEAL 1.5 SERIES Connectors

RUE Selection Guide and Product Data. RUE Selection Guide

Mar11 Rev C

SPECIFICATION OF ANALOG MEMS MICROPHONE. ( Ultra Mini Top Port ) MODEL NO. : F1-(A)MOE-C110T42-4CP

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

FEATURES AND BENEFITS

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

G4 Pulsed Fiber Laser

ThermoCable Linear Heat Detection System

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

DESCRIPTION INSTALLATION

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

R UNIT 5. Tools of the Trade

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

AMP SUPERSEAL 1.5 SERIES Connectors

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

General Specifications

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Application Specification MAG-MATE* Poke-In Tab Terminals

Fibre Specification Standards

INSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES WE GO TO EXTREMES TO MAKE EVERY CONNECTION COUNT

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

AC-046 Peltier-Thermoelectric Air Cooler

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

Fiber Optic Products Catalog

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Introducing Low Voltage DC Grid Interconnects

MT-RJ Optical Fiber System Field Testing

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

EPON ONU Optical Transceiver SFF Module

Compact Module. Category 6A FTP Cabling System 1.1

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Low-Power CMOS ALARM IC with Horn Driver

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

PD10. Serial Plates with Side Ports for ISO Valves. Technical Features. Technical Data. Functional Description. Page 1. Size 10 (D05) p max

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

Precision Crimp Wrenches

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

DROP IN POPCORN WARMERS

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

SOLARLOK Interconnection System Installation Manual

Aerospace Linear Variable Differential Transformers Single Channel, Dual Parallel, & Dual Tandem Series Issue 1. Datasheet

Apr06 Rev A

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

AMR 4-Pin Quadrature Sensor Integrated Circuit

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

C2M Simulation and Methodology

Transcription:

4 Need more information? all Technical Support at the numbers listed below. Technical Support is staffed with specialists well versed in all Tyco Electronics products. They can provide you with: Technical support atalogs Technical Documents Product Samples Tyco Electronics uthorized Distributor Locations For current tooling information, call the Tooling ssistance enter: 1-800-722-1111. Produced under a Quality Management System certified to ISO 9001 copy of the certificate is available upon request. Dimensioning: are in millimeters and inches unless specified otherwise. Values in brackets are equivalent U.S. customary units. Metric symbols used are: (elsius) Kg (Kilogram) N (newton) m (meter) mm (millimeter) mm 2 (square millimeter) Specifications subject to change. onsult Tyco Electronics for latest design applications. ISO 9001 ertified Table of ontents Signal Integrity Services: Taking SI to the Next Level............................................ 1 High Speed Stacking onnectors (Parallel and Right-ngle oard-to-oard) Stacking Height Guide........... 2 Introduction.......................................................................... 5 5.00 [.197] Receptacles................................................................ 6 15.00 [.591] Receptacles............................................................... 7 10.00 [.394] Plugs..................................................................... 8 1 [.472] Plugs..................................................................... 9 13.00 [.512] Plugs.................................................................... 10 15.00 [.591] Plugs.................................................................... 11 20.00 [.787] Plugs.................................................................... 12 25.00 [.984] Plugs.................................................................... 13 MITOR (0.64 [.025] enterline) Introduction......................................................................... 14 onnector ross Section.............................................................. 15 Material and Performance Specifications.................................................. 16 Stack Height ombinations............................................................ 17 Right-ngle (Straddle Mount) ombinations............................................... 18 Vertical Plugs: 6.60 [.260] Stacking Height....................................................... 19, 20 8.99 Stacking Height....................................................... 21, 22 10.92 [.430] Stacking Height...................................................... 23, 24 12.57 [.495] Stacking Height..................................................... 25, 26 17.96 [.707] Stacking Height..................................................... 27, 28 18.75 [.738] Stacking Height....................................................... 29 20.02 [.788] Stacking Height...................................................... 30, 31 22.86 [.900] Stacking Height...................................................... 32, 33 Right-ngle Plugs................................................................. 34, 35 Vertical Receptacles............................................................... 36, 37 Vertical Receptacles (Extended Height)................................................ 38, 39 Right-ngle Receptacles........................................................... 40, 41 MITOR S Introduction......................................................................... 42 Material and Performance Specifications.................................................. 43 Stack Height ombinations............................................................ 44 onnector ross Section.............................................................. 45 0.80 [.032] enterline Receptacles...................................................... 46 0.80 [.032] enterline Plugs 5.00 [.197] Stacking Height.......................................................... 47 8.00 [.315] Stacking Height.......................................................... 48 11.00 [.433] Stacking Height......................................................... 49 14.00 [.551] Stacking Height......................................................... 50 16.00 [.630] Stacking Height......................................................... 51 1 [.748] Stacking Height......................................................... 52 2 [.866] Stacking Height......................................................... 53 25.00 [.984] Stacking Height......................................................... 54 30.00 [1.181] Stacking Height........................................................ 55 0.50 [.020] enterline Receptacles...................................................... 56 0.50 [.020] enterline Plugs 5.00 [.197] Stacking Height.......................................................... 57 8.00 [.315] Stacking Height.......................................................... 58 11.00 [.433] Stacking Height......................................................... 59 14.00 [.551] Stacking Height......................................................... 60 16.00 [.630] Stacking Height......................................................... 61 1 [.748] Stacking Height......................................................... 62 2 [.866] Stacking Height......................................................... 63 25.00 [.984] Stacking Height......................................................... 64 30.00 [1.181] Stacking Height........................................................ 65 Micro-Strip (1.27 x 2.54 [.050 x.100] enterline) Introduction...................................................................... 66-67 Vertical Plugs: 10.92 [.430] Stacking Height....................................................... 68-70 18.75 [.738] Stacking Height...................................................... 71, 72 Vertical Receptacles.................................................................. 73 Right-ngle Receptacles........................................................... 74, 75 Extended Vertical Receptacles......................................................... 76 pplication Tooling for MITOR Right-ngle onnectors......................................... 77 TION PIN Press-Fit ontacts......................................................... 78, 79 pplication Tooling for Micro-Strip onnectors with TION PIN ontacts............................ 80 Technical Documents.................................................................. 81 PREISION INTERONNET LUE RION oax ssemblies................................... 82, 83 Part Number Index..................................................................... 84

Introduction to the Product Facts Excellent electrical performance for applications requiring 10+ Gb/s data rates Multipair differential cross talk less than 3% at 100 ps risetime for all stack heights Impedance specification of 100 ohms for Differential Pair configuration and 50 ohms for Single-Ended configuration Stack heights available ranging from 15.00 [.590] to 35.00 [1.378] High Speed position sizes ranging from to per connector SMT G attachment Dual beam signal contacts for high reliability Receptacle contacts fully protected with plastic cover Polarized housing design Packaging available for Trays or Tape & Reel High temperature housing plastic aps for use with vacuum pick & place equipment The connector is a grid array mezzanine connector specifically designed for high speed and high density applications up to 10+ gigabit per second data rates. Pin out patterns for either differential pair or single ended provide excellent isolation of high speed signals. Ground connections in close proximity to signal connections enable proper electrical coupling through the entire interconnect dramatically reducing crosstalk. The connector system maintains a 100 ohm impedance for differential applications and a 50 ohm impedance for singleended applications throughout the interconnect. all Grid rray attachment for both halves minimizes the performance degradation typically found with through hole connections and improves routing capability. Dual beam signal contacts provide for a highly reliable interface connection. The connector housing is polarized to ensure proper mating. 10 Gbps Reference Eye Pattern 20 mm Stack 10 Gbps Differential Eye Pattern 25 mm Stack 10 Gbps Differential Eye Pattern Mask mplitude was set to 25% (mv p-p) of the input signal and mask width was set to 40% (40 ps) of the input signal. 5

5.00 [.197] Receptacles Optional Pick-Up ap Position 1 1 ± 0.20 [.419 ±.008] 4.52 [.178] 28.60 [1.126] Position T25 ontacts In These Rows re (ommoned) 24x 49x Stencil onnector Outline Onto oard Recommended P oard Layout Pos.* With Pick & Place ap 22.60 16.25 8.13 SnPb 1761613-5.890.640.320 Pb-free 5-1761613-5 38.20 31.85 15.93 SnPb 1761615-5 1.504 1.254.627 Pb-free 5-1761615-5 53.75 47.45 23.73 SnPb 1761617-5 2.116 1.868.934 Pb-free 5-1761617-5 Tray packaged shown. ontact Tyco Electronics Engineering for Tape and Reel 6 Note: are RoHS compliant except: Indicates non-rohs compliant;

(ontinued) 15.00 [.591] Receptacles Optional Pick-Up ap 2 ± 0.20 [.813 ±.008] 14.51 [.572] Position 1 28.60 [1.126] Position T37 ontacts In These Rows re (ommoned) 36x 73x Stencil onnector Outline Onto oard Recommended P oard Layout Pos.* With Pick & Place ap 22.60 16.25 8.13 SnPb 1-1761613-5.890.640.320 Pb-free 6-1761613-5 38.20 31.85 15.93 SnPb 1-1761615-5 1.504 1.254.627 Pb-free 6-1761615-5 53.75 47.45 23.73 SnPb 1-1761617-5 2.116 1.868.934 Pb-free 6-1761617-5 Tray packaged shown. ontact Tyco Electronics Engineering for Tape and Reel Note: are RoHS compliant except: Indicates non-rohs compliant; 7

(ontinued) 10.00 [.394] Plugs Position 1 Position T25 28.60 [1.126] Optional Pick-Up ap 10.95 ± 0.25 [.431 ±.010] 9.65 ± 0.12 [.380 ±.005] ontacts In These Rows re (ommoned) 24x 49x Stencil onnector Outline Onto oard Recommended P oard Layout Pos.* With Pick & Place ap 22.60 16.25 8.13 SnPb 1-1761612-0.890.640.320 Pb-free 6-1761612-0 38.20 31.85 15.93 SnPb 1-1761614-0 1.504 1.254.627 Pb-free 6-1761614-0 53.75 47.45 23.73 SnPb 1-1761616-0 2.116 1.868.934 Pb-free 6-1761616-0 Tray packaged shown. ontact Tyco Electronics Engineering for Tape and Reel 8 Note: are RoHS compliant except: Indicates non-rohs compliant;

(ontinued) 1 [.472] Plugs Position T37 Position 1 28.60 [1.126] Optional Pick-Up ap 12.95 ± 0.25 [.510 ±.010] 11.65 ± 0.12 [.459 ±.005] ontacts In These Rows re (ommoned) 36x 73x Stencil onnector Outline Onto oard Recommended P oard Layout Pos.* With Pick & Place ap 22.60 16.25 8.13 SnPb 1-1761612-2.890.640.320 Pb-free 6-1761612-2 38.20 31.85 15.93 SnPb 1-1761614-2 1.504 1.254.627 Pb-free 6-1761614-2 53.75 47.45 23.73 SnPb 1-1761616-2 2.116 1.868.934 Pb-free 6-1761616-2 Tray packaged shown. ontact Tyco Electronics Engineering for Tape and Reel Note: are RoHS compliant except: Indicates non-rohs compliant; 9

(ontinued) 13.00 [.512] Plugs Position 1 Position T25 28.60 [1.126] Optional Pick-Up ap 13.95 ± 0.25 [.549 ±.010] 12.65 ± 0.12 [.498 ±.005] ontacts In These Rows re (ommoned) 24x 49x Stencil onnector Outline Onto oard Recommended P oard Layout Pos.* With Pick & Place ap 22.60 16.25 8.13 SnPb 1-1761612-3.890.640.320 Pb-free 6-1761612-3 38.20 31.85 15.93 SnPb 1-1761614-3 1.504 1.254.627 Pb-free 6-1761614-3 53.75 47.45 23.73 SnPb 1-1761616-3 2.116 1.868.934 Pb-free 6-1761616-3 Tray packaged shown. ontact Tyco Electronics Engineering for Tape and Reel 10 Note: are RoHS compliant except: Indicates non-rohs compliant;

(ontinued) 15.00 [.591] Plugs 0.42 [.017] Position T25 15.95 [.628] 14.65 [.577] 28.60 [1.126] Position 1 Ø ± 0.05 [.022 ±.002] Typ. Typ. Stencil onnector Outline Onto oard Recommended P oard Layout Pos.* With Pick & Place ap 22.60 16.25 8.13 SnPb 1-1761612-5.890.640.320 Pb-free 6-1761612-5 38.20 31.85 15.93 SnPb 1-1761614-5 1.504 1.254.627 Pb-free 6-1761614-5 53.75 47.45 23.73 SnPb 1-1761616-5 2.116 1.868.934 Pb-free 6-1761616-5 Tray packaged shown. ontact Tyco Electronics Engineering for Tape and Reel Note: are RoHS compliant except: Indicates non-rohs compliant; 11

(ontinued) 20.00 [.787] Plugs Position T37 Position 1 28.60 [1.126] Optional Pick-Up ap 20.94 ± 0.25 [.824 ±.010] 19.64 ± 0.12 [.773 ±.005] ontacts In These Rows re (ommoned) 36x 73x Stencil onnector Outline Onto oard Recommended P oard Layout Pos.* With Pick & Place ap 22.60 16.25 8.13 SnPb 2-1761612-0.890.640.320 Pb-free 7-1761612-0 38.20 31.85 15.93 SnPb 2-1761614-0 1.504 1.254.627 Pb-free 7-1761614-0 53.75 47.45 23.73 SnPb 2-1761616-0 2.116 1.868.934 Pb-free 7-1761616-0 Tray packaged shown. ontact Tyco Electronics Engineering for Tape and Reel 12 Note: are RoHS compliant except: Indicates non-rohs compliant;