QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

Similar documents
MARSTAIR INDEX. Product Description. Cellarator Units Condensing Units 3-6. Condensing Units - Ducted 7

IPAC Air Handling Units

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

System architecture. Air treatment Index

Modular Air Cooled Scroll Chillers

Ducted Air Conditioning

gforce Units Data Aire and Data Temp Series

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

Flexible & Innovative. Cooling Solutions

Flexible and efficient: Close Climate Control for IT equipment

IPAC. Invicta Precision Air Control Floor Standing Range

Ducted Air Conditioning

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

Denco has been producing and installing. equipment specifically designed for the precise. control of air temperature, humidity and quality

Heat Pump Air Conditioning Systems

technical data Fan coil unit FWB small duct unit

DATA & FACTS Close Control Units Multi-DENCO. Flexible and Efficient

Aegean Range. A new range of fan coils for heating and cooling commercial applications

3 rd Generation of VRV. The professional solution for your professional project

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Air Curtains. For a better working environment. Tel:

Product Specifications. Vertical Floor Consoles By First Co.

Technical Data Ducted Three Phase Split System Air Conditioner

Guide Specifications for InRow Direct Expansion

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

Close Control Air Cooled Twin Circuit Range

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Innovative air conditioning

TECHNICAL MANUAL. for 529 SERIES CELLARATOR SPLIT SYSTEMS

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Integrated VarIable refrigerant flow ahu/pau (r410a)

Amena s Globo series are a group of air conditioning products designed for markets where maximum

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

RE9X Series Downflow, Upflow Electric Furnaces

UniTrane Ductable Units D-line and B-Line

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

TOSHIBA AIR CONDITIONING

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Q-TEC QC-Series Chilled Water Air Conditioner

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

HVS, Hydro Variable System Air cooled chiller

R4H4. Product Specifications

ROOFTOP PACKAGED AIR CONDITIONERS

AQUASNAP JUNIOR 30RHV

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Caice Attenuator Selector - Specifier Edition

COMFORT HYDRONIC TERMINALS

HVS, Hydro Variable System

Just feel well. 2017/2018 Air conditioning

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Blending Commercial and Residential. MiNi VRF

ESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

Q-Tec TM QC-Series Chilled Water Air Conditioner

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

Business. The business range. The most advanced solutions for larger buildings.

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Metropolitan high output natural and powered trench heaters

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Liebert PDX and PCW Thermal Management Systems

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

2013 Product Range Precision Air Conditioners (CRAC)

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

Ductless Series Variable Speed Split Systems

TECHNICAL SPECIFICATIONS

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Air Cooled Packaged Systems AIRAH Back to Basics

Transcription:

AIR CONDITIONING An air conditioned environment is increasingly expected in retail, commercial and industrial premises. Whilst there will always be a demand for custom built air conditioning the standard off the shelf product market continues to grow. Established 25 years ago, Qualitair was one of the first British manufacturers of standard air conditioning products and it was acquired by Eaton-Williams Group in 1993. This has created an air conditioning business that can provide standard product solutions to a wide range of specialised applications and projects. The Qualitair portfolio covers chilled water and DX (direct expansion) refrigeration product ranges including ceiling cassettes, high and low wall split systems, free standing or in-wall packaged units, concealed fan-coil units and roof-top models. Qualitair can cater for simple cooling only requirements up to full close control unit applications for computer or control room areas. For food preparation areas it offers a unique low temperature ceiling cassette that can operate down to 10ºC, meeting many of the forthcoming EU directives and legislation. Cellar cooling, storage of fresh fruit, vegetables and florist stocks are protected with Qualitair refrigeration split systems. Qualitair products are supported by an in-house technical team and all products come with a 3-year warranty. Qualitair was one of the first manufacturers to have products tested, duties verified and performances certified by Eurovent.

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS QCeiling Cassettes Fan Coil Units Floor Standing Units Roof Top or Ceiling Void Packaged System In-Wall Packaged System

PACKAGED AND APPLIED PRODUCTS 2 3 1 5 MVU QST The 600 and 700 series floor & 1. Roof Top or Ceiling Void Packaged System The versatile MVU roof top and ceiling void range offers the installer and designer the choice of either locating the unit on the roof or in a ceiling void. Easily installed and only requiring connecting to supply and return air ducting and power, the range is ideal for many installations. 2. In-Wall Packaged System The QPM in-wall unit can be mounted at high or low level, 4 QPM 700 with a slim 235mm casing within QCH the room and the main sections contained in the standard 280mm wall with no projection on the outside of the building. Cooling only or full heat pump versions available. 3. Fan Coil Units The QST Stowaway chilled water fan coil units are suitable for universal mounting in concealed ceiling or wall mounted installations or can be provided in a customised casing for floor standing or wall mounting. The range is suitable for hotels, hospital suites, conference rooms and any multiple or single site applications. 4. Ceiling Cassettes The QCH chilled water ceiling cassette range offers cooling and LPHW heating features to the contractor. The design of the cassette enables the unit to fit into the standard 600mm square and 600 1200mm ceiling tile openings. Optional fascias and valves complete the range. 5. Floor Standing Units standing compact chilled water range combines versatility and high performance to meet with the needs of today s modern offices and manufacturing plants. Basic modules form the design concept with the adaptability of being able to have upflow or downflow, ducted or free blow header boxes fitted. Units can be supplied in any B.S. colour to order. FAX: 01732 866731 Name: Company: Address: Telephone: ATTENTION OF PETER DEWDNEY Postcode: Facsimile: Eaton-Williams Group Limited Station Road, Edenbridge Kent TN8 6EG, England Telephone: +44 (0)1732 866055 Facsimile: +44 (0)1732 863461 0413019 QPA/7.97/1

QUALITAIR QCH3 CHILLED WATER CASSETTE Low Profile Fascia. Cooling and Heating. 3 Fan Speeds. Wall and Floor Space Saving. Options: LPHW Heating Coil. Electric Resistance Heating. Valve Arrangements. Condensate Lift Pump. Fresh Air Inlet. 2, 3 or 4-Way Air Distribution. Optional Fascia Designs. The Qualitair QCH3 chilled water cassette fan coil unit fits directly into the standard 600mm square ceiling tile opening. The QCH3 cassettes are particularly suitable for all large buildings, offices and hotels with a high internal heat gain. Valuable floor and wall space is saved by using the QCH3 cassettes chilled water systems, with optional hot water heating coil available for all year round effectiveness. QCH3 RANGE Air Conditioning

1 2 3 Cooling only Cooling Capacity 3.5 kw (Maximum Airflow) Cooling and Electric Entering Air Water Water Water Pressure Heating Temperature Temperature Flow Drop Cooling Capacity 3.5 kw (Maximum Airflow) Electric Resistance 1.5 kw Heater (Optional) Cooling and LPHW Entering Air Water Water Water Pressure Heating Temperature Temperature Flow Drop Cooling Capacity 3.5 kw (Maximum Airflow) TECHNICAL SPECIFICATIONS QCH3 cooling and heating capacities Entering Air Water Water Water Pressure Temperature Temperature Flow Drop 27ºC db 19ºC wb 27ºC db 19ºC wb 27ºC db 19ºC wb 7ºC 0.17 l/s 36 Kpa 7ºC 0.17 l/s 36 Kpa 230 volts / single phase / 50Hz 7ºC 0.17 l/s 36 Kpa Heating Capacity 3.0 kw (Maximum Airflow) 20ºC 70ºC 0.10.l/s 21 Kpa LPHW Coil (Optional) QCH3 OPTIONS Fascia Plastic / Steel Fascia Steel Unit With Valves External Valve Condensation Tray Fresh Air Kit Fresh Air Fan Kit Condensate Lift Pump Electro Mechanical Thermostat Electronic Thermostat Branch Duct Kit Full technical data sheets available for other capacities and options part numbers. Noise Levels at 1.5m From Fascia (Fan Speeds / Air flow = m 3 /s) Fan Low Fan Medium Fan High (0.10) (0.12) (0.17) Electrical Supply 230 volts / single phase / 50Hz Water Connections (Flow and Return) 29 dba 36 dba 44 dba NR23 NR31 NR39 Cooling: 1/2 BSPM Heating: 1/2 BSPM Condensate 15mm o/d F CH3 565mm 637mm Over Mounting Plates 605mm Unit Mounting Centres Valve Drip Tray Mounting Plates in Transit Position 210mm 535mm Mounting Centres 565mm 290mm Cooling Flow Ø 15 Return 292mm Heating Valve Drip Tray 565mm Electrical Fresh Air Duct Condensate 630mm Fascia (Plastic) 615mm Fascia (Metal) 150mm 60mm 43mm 23mm 28mm 242mm Eaton-Williams Group Limited Station Road, Edenbridge Kent TN8 6EG, England Telephone: 01732 866066 Facsimile: 01732 866653 We reserve the right to alter specifications without notice and products will sometimes be supplied with modifications which do not strictly comply with the descriptions and illustrations in this publication. 0413007 QCH3 /5.96/1

QUALITAIR QDX CEILING CASSETTE RANGE Cooling and Heat Pump or Electric Heat. Low Profile Fascia. Condensate Lift Pump. 3 Fan Speeds. Low Pressure Switch as Standard. Wall and Floor Space Saving. 3 Year Warranty. Fan Speed Control. Options: Branch Duct / Fresh Air Spigot. Electric Resistance Heating. 3 or 4-Way Air Distribution. Optional Fascia Designs. Thermostat Controls. The Qualitair QDX direct expansion cassette fan coil units fit directly into standard 600mm square and 600 1200mm ceiling tile openings. The QDX cassettes are particularly suitable for any buildings, restaurants, offices and hotels with a high internal heat gain. Valuable floor and wall space is saved by using the QDX cassette split systems, offering cooling and heating for all year round effectiveness. The QRO outdoor units complete the QDX system. QRO units come with scroll and rotary compressors and are extremely slim. QDX RANGE Air Conditioning

Cooling TECHNICAL SPECIFICATIONS QDX (indoor unit) and QRO (outdoor unit) technical data Capacity* Optional Airflow Noise Levels (Max) Refrigerant Elect Heater m 3 /s kw Btu/hr kw (Max) QDX QRO QDX3 3.5 12000 R22 1.5 0.15 44 QRO12 0.45 48 QDX5 5.0 17100 R22 1.5 0.19 51 QRO18 0.45 47 QDX OPTIONS Ultra Slim Fascia Fresh Air Kit Heating QDX7 6.7 23000 R22 1.5 0.21 53 QRO24 0.70 53 QDX11 10.3 35100 R22 3.0 0.37 55 QRO36 0.70 54 * Cooling capacities based on: 27ºC db / 19ºC wb indoors; 35ºC db / 24ºC wb outdoors (maximum fan speed). Average dba noise levels at 1.5m from fascia. NR noise levels at 3m free field. kw Capacity Btu/hr QDX3 3.5 12000 QDX5 5.0 17000 QDX7 6.6 22500 QDX Fan Speeds / Airflow = m 3 /s (dba Noise Levels at 1.5m from Fascia) Fan Low Fan Medium Fan Boost 0.09 (dba 29) 0.12 (dba 36) 0.15 (dba 44) 0.14 (dba 44) 0.17 (dba 48) 0.19 (dba 51) 0.16 (dba 48) 0.18 (dba 51) 0.21 (dba 53) QDX11 9.4 32100 0.28 (dba 47) 0.33 (dba 52) 0.37 (dba 55) Heating capacities based on: 20ºC db / 12ºC wb indoors; 7ºC db / 6ºC wb outdoors (maximum fan speed). Fresh Air Fan Kit Electro Mechanical Thermostat Electronic Thermostat Branch Duct Kit Air Baffle Kit Electric Heater Condensate Pump Alarm Relay Full technical data sheets available with options part numbers. System Electrical Supply Options** 230 Volts 400 Volts Single Phase Three Phase 50Hz 50Hz QDX3/QRO12 QDX5/QRO18 QDX7/QRO24 Weight Dimensions Connections Kg (Nett) A B C Suct o/d Liquid o/d QDX3 23 630 630 290 60 5/8 1/4 QRO12 42 720 610 250 5/8 1/4 QDX5 23 630 630 290 60 5/8 1/4 QRO18 60 800 765 320 5/8 1/4 B 107mm 93mm QDX11/QRO36 ** QDX (only): 230 volts / single phase control. 479mm 292mm 71mm Liquid Suction Electrical Electrical Fresh Air Duct 550mm QDX indoor unit 79mm 693mm 1160mm Suction A Fascia Liquid 150mm QDX3/5/7 64mm QDX11 Only DX We reserve the right to alter specifications without CA Fascia (Plastic) QDX7 25 630 630 290 60 3/4 3/8 QRO24 64 800 765 320 3/4 3/8 QDX11 43 630 1230 290 60 3/4 3/8 QRO36 88 1050 765 320 3/4 3/8 615mm Fascia (Metal) 107.5mm 93.5mm 243mm C Eaton-Williams Group Limited Station Road, Edenbridge Kent TN8 6EG, England Telephone: +44 (0)1732 866066 Facsimile: +44 (0)1732 867937 23mm QRO outdoor unit A notice and products will sometimes be supplied with modifications which do not strictly comply with the descriptions and illustrations in this publication. C 0413010 QDX /2.97/1 Airflow 130mm Minimum distance from wall B

QUALITAIR QPM II IN-WALL PACKAGED AIR CONDITIONER In the wall packaged air conditioner with heat pump model options. Slim indoor section. No projection on the exterior of building. Easy installation and maintenance. Free cooling mode. Rotary/Scroll compressors. Low noise levels. Low starting currents. Fully factory tested with Three Year Warranty. Optional architectural grilles for external mounting. Interior section Wall section The Qualitair QPM II range is the building designer s answer to air conditioning. Particularly suited to high-rise shallow buildings, the elegant QPM II cabinet takes up only 235mm of space in the room the rest of the unit is contained within a standard 280mm wall with no projection on the outside of the building. The slim room section is light grey, two tone and has an attractive cabinet with formed ends and decorative panels. The QPM II range is designed to meet architects requirements for an in the wall complete air conditioning unit. The unit can be mounted at high or low level and the adjustable grilles can be positoned to provide complete comfort. The use of architectural grilles on the outside ensures that the installation blends with, and complements, the design of the building. QPM II units are available in two cooling capacities: 3.4kW and 5.0kW, and have automatic heat pump heating and fresh air free cooling facility. Control panel contains a function selector switch and thermostat. Simply select the temperature required, choose boost or normal and the QPM II unit will automatically maintain comfort conditions. A third position selects free cooling fresh air with normal fan speed. A fourth position selects fan only at low speed for recirculating and fresh air. QPM II RANGE Air Conditioning

TECHNICAL SPECIFICATIONS QPM II Range cooling capacities and dimension data Capacity Airflow Noise Weight Dimensions mm m 3 /s Level kw Btu/hr kg NR A B C D E F G QPM12 3.4 11600 0.13 41 80 955 570 235 813 408 267 71 QPM18 5.1 17300 0.21 43 102 1136 570 235 1076 450 285 30 QPM12 HP Heat Pump QPM18 HP Heat Pump 3.4 11600 0.13 41 80 955 570 235 813 408 267 71 5.1 17300 0.21 43 102 1136 570 235 1076 450 285 30 Cooling capacities based on 27ºC db / 19ºC wb indoors and 35ºC ambient outdoors. (NR) Noise levels at 3 metres and normal fan speed. QPM II Range heating capacities and electrical data QPM12 Electric Heater QPM18 Electric Heater QPM12 Heat Pump QPM18 Heat Pump Capacity Airflow Electrical Running Starting HBC Fuse m 3 /s Supply Current Current Rating kw Btu/hr Amps Amps Amps 2.5 8530 0.13 230 volts / single phase / 50Hz 7.4 31 16 2.8 9554 0.21 230 volts / single phase / 50Hz 11.6 57 16 3.6 12300 0.13 230 volts / single phase / 50Hz 11.2 31 16 5.3 18100 0.21 230 volts / single phase / 50Hz 18.6 59 25 Heat pump capacities based on 7ºC ambient outdoors. B 100mm minimum C Interior section Floor Wall 40mm 6mm PM II Wall section F Services entry E 17mm G 120mm 30mm Services entry A Interior section D Wall section shown dotted Eaton-Williams Group Limited Station Road, Edenbridge Kent TN8 6EG, England Telephone: +44 (0)1732 866066 Facsimile: +44 (0)1732 867937 We reserve the right to alter specifications without notice and products will sometimes be supplied with modifications which do not strictly comply with the descriptions and illustrations in this publication. 0413003 QPMII /9.98/1

QUALITAIR QFS600 DX & CHILLED WATER FLOOR STANDING RANGE 10-40kW Cooling Only. Cooling and Heating or Full Air Conditioning s. DX or Chilled Water Cooling. Upflow or Downflow Air Supply. Microprocessor Controls as Standard. Compact Module Design. Front Access. Minimum Space. Options: B.S. Colour Coded Finishes. Base Plinths. Header Plenums. Condensate Pump. Quiet Downflow Units. High Efficiency Filters. Humidifier. Water Cooled Condensers. BMS Interface (Volt Free Contacts). The QFS600 Floor Standing range combines application versatility with compact console unit design. Each QFS600 module occupies an area 600 600mm delivering up to 34kW of cooling from 1 square metre of floor space. Whether the application is for spot cooling in a production area or an office, up to the demands of a computer room or studio, the QFS600 can be matched economically for the project. With optional B.S. colour coded finishes, upflow or downflow air supply, DX or chilled water models and microprocessor controller as standard, the QFS600 range provides the installer and designer with an ideal solution. The QCV external condensers are matched for the DX models. QFS RANGE 600 Air Conditioning

TECHNICAL SPECIFICATIONS QFS600 Range technical data Capacity* Electric Humidifier DX s C/W s Airflow Number of Heater Output DX C/W Fans Capacity (when fitted) Number of Condenser Water Flow kw kw m 3 /s kw kg/hr Compressors l/s QFS600/1 12.5 12.1 0.95 1 7.5 2 1 QCV1-18 0.53 QFS600/2 20.0 20.5 1.60 1 15.0 4 1 QCV1-40 0.90 QFS600/3 33.0 28.0 2.40 2 15.0 4 2 2 QCV1-40 1.22 QFS600/4 40.0 41.0 3.20 2 15.0 4 2 2 QCV1-40 1.80 * Capacities based on air entry of 22ºC db / 15ºC wb, C/W inlet temperature 7ºC, DX condenser (30ºC ambient). Electrical data Electrical Supply: 400 Volts Three Phase N 50Hz Running Current Per Phase (Amps) Fan Motor Compressor(s) Heater(s) Humidifier QFS600/1 2.5 8.4 10.4 3.0 QFS600/2 3.7 13.6 20.8 5.0 QFS600/3 4.9 21.8 20.8 5.0 QFS600 OPTIONS B.S. Colour Coded Finishes Base Plinths Header Plenums QFS600/4 7.4 27.2 20.8 5.0 Dimensions and weights Height (A) Width (B) Depth (C) Weight mm mm mm kg QFS600/1 1850 600 650 165 QFS600/2 1850 1200 650 250 Condensate Pump Quiet Downflow Units High Efficiency Filters Humidifier Water Cooled Condensers A QFS600/3 1850 1800 650 375 QFS600/4 1850 2405 650 495 FS Full technical data sheets available with options part numbers. QFS600/1 QFS600/2 QFS600/3 QFS600/4 BMS Interface B B B B C 600 Eaton-Williams Group Limited Station Road, Edenbridge Kent TN8 6EG, England Telephone: +44 (0)1732 866066 Facsimile: +44 (0)1732 867937 We reserve the right to alter specifications without notice and products will sometimes be supplied with modifications which do not strictly comply with the descriptions and illustrations in this publication. 0413000 QFS600 /8.97/1

QUALITAIR QFS700 DX & CHILLED WATER FLOOR STANDING RANGE 25-80kW Cooling Only, Cooling and Heating or Full Air Conditioning s. DX or Chilled Water Cooling. Upflow or Downflow Air Supply Units. Microprocessor Controls as Standard. Compact Module Design. Easy Access for Service and Maintenance. Options: B.S. Colour Coded Finishes. Base Plinths. Condensate Pump. High Efficiency Filters. Water Cooled Condensers. Communication Choices. The QFS700 Floor Standing range offers a choice of cooling options in a compact modular design. The range offers simple spot cooling, cooling and heating or full air conditioning models. With DX or chilled water cooling, upflow or downflow air supply, standard or high efficiency filters, Vapac humidifier fitted (full air conditioning models) and microprocessor controller as standard, the QFS700 range is suitable for many applications. Where necessary, the QSF700 range can be supplied in any B.S. colour coded finish to match the site location decor and furnishings. The Qualitair QCV external air cooled condensers are matched for the QFS700 DX models or water cooled condensers may be provided for water/glycol cooled project models. The chilled water QFS700 units are fitted with control and balancing valves as an integral part of all models. QFS RANGE 700 Air Conditioning

TECHNICAL SPECIFICATIONS QFS700 Range technical data Maximum Capacity* Electric Humidifier DX s C/W s Maximum Number Heater Output DX C/W Airflow of Capacity (when fitted) Number of Condenser Water Flow kw kw m 3 /s Fans kw kg/hr Compressors l/s QFS700/1 32.6 30.0 2.50 1 15.0 6 2 2 QCV1-18 1.08/1.30 2 QCV1-40 QFS700/2 59.0 55.0 4.05 2 22.5 8.12 2 or 1.75/2.64 2 QCV2-40 QFS700/3 80.0 80.0 6.00 2 30.0 15 2 2 QCV2.70 3.05/3.47 * Capacities based on air entry of 22ºC db / 15ºC wb, C/W inlet temperature 7ºC, DX condenser (30ºC ambient). (Duplex) fans fitted. Electrical data Electrical Supply: 400 Volts Three Phase N 50 Hz Running Current Per Phase (Amps) Fan Motor(s) Compressor(s) Heater(s) Humidifier QFS700/1 6.9 22.0 to 28.0 21.0 7.0 QFS700/2 8.4 32.0 to 46.0 31.5 9.0 to 13.5 QFS700/3 16.8 46.0 to 58.0 42.0 17.0 QFS700 OPTIONS B.S. Colour Coded Finishes Base Plinths Condensate Pump Dimensions and weights Height (A) Width (B) Depth (C) Weight mm mm mm kg DX C/W DX C/W DX C/W DX C/W High Efficiency Filters Humidifier Water Cooled Condensers QFS700/1 1800 1800 2105 1660 730 730 580 460 QFS700/2 1800 1800 2795 2350 730 730 780 630 QFS700/3 1800 1800 2795 2350 930 930 950 750 BMS Interface Full technical data sheets available with options part numbers. FS B B C QFS700/1 QFS700/2/3 QFS700/3 Filter Chamber A 200 mm Free Returns 400 mm Ducted or HEF 700 Eaton-Williams Group Limited Station Road, Edenbridge Kent TN8 6EG, England Telephone: +44 (0)1732 866066 Facsimile: +44 (0)1732 867937 We reserve the right to alter specifications without notice and products will sometimes be supplied with modifications which do not strictly comply with the descriptions and illustrations in this publication. 0413001 QFS700 /11.97/1