Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers. 8th March 2016 Dr Tim Nichols CPhys MIFireE

Similar documents
FM Approvals & Water Mist Systems. Paul Bardsley Engineer, FM Approvals

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

FUEL. Fire & Flammable Liquids Properties. Flammable & Combustible Liquid Safety. Safety. Practice. Laws: OSHA & NFPA. Safety.

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Fixed fire protection solutions

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

COMMERCIAL KITCHEN FIRE SAFETY

A Guide for Meeting NFPA 10 Subsection


READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

Water Spray Systems: NFPA 15

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

Fire Safety PPT-SM-FIRESFTY V.A.0.0

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

CO 2 Fire Extinguishing Systems

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

ANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

Fire Prevention Plan Program

Fire is No Accident Fire is No Accident It can be prevented.

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Watermist Fire Protection of Plant Rooms

UNDER CABINET RANGE HOOD

SUPPRESSION SALES I INSTALLATION I SERVICE

TAMUCC Fire Safety Training

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Up on the Roof Fire Prevention BY David Laks, P. Eng., CFPS, ARM, RRC

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Water Mist Fire Suppression

Explosion Protection Engineering Principles

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

Making sense of risk Risk engineering. Metalworking operations

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

Leader s Guide 2007 CLMI Training

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Technical Discussion on

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

INSTALLATION & OPERATION MANUAL GAS CHARBROILERS

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

ODS & SGG Alternatives for the Fire Protection Industry 2018

Flammable and Combustible Liquids

Water Mist System. Principle of Water mist evolves from combination of 3 main effects:

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

& Fire Extinguisher Training

LABORATORY SAFETY SERIES: Flammables & Explosives

Portable Fire Extinguishers

Fire protection for buildings

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

APPUZO RANGE HOOD INSTALLATION

DUST EXPLOSION CODES AND STANDARDS: Ensuring Regional Compliance and Global Consistency

Flammable Liquid Storage

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Kitchen Fire Suppression Systems Post-Event Analysis

2012 ICC Commercial Kitchen Hoods

Fire Safety and Utility Controls. CERT Basic Training Unit 2

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Above Ground Fuel Tank Requirements

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

WATER MIST CONVENTION AND EXHIBITION

FIXED PROTECTION FOR OIL AND CHEMICAL PLANTS

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

The regulatory section first discusses codes and standards and then Federal and State legislative and local requirements.

2015 ICC Commercial Cooking Systems

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Mobile Vendors Bulletin

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

WSU-TFREC Fire Safety Training

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

HEATEC PRODUCTS AND SERVICES FOR THE FOOD INDUSTRY

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

Spray Painting and Coating

Cadet Entry Level Award(ELA) Part Four. Fire Safety

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

2How does a vibratory fluid-bed dryer work?

Ships and marine technology Fireextinguishing. of galley cooking equipment

Chapter One Commercial Kitchen Fires

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

Rick Seidel Fike Corporation Regional Sales Manager

REGISTRATION EXAMINATION, JUNE 2012 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

PROFESSIONAL KITCHEN CLEANING. New Kitchen Ventilation Systems supplied and fitted at competitive rates

Transcription:

Water Mist Fire Protection Systems for the Protection of Industrial Oil Cookers 8th March 2016 Dr Tim Nichols CPhys MIFireE

Industrial Oil Cookers 2

What are Industrial Oil Cookers Large cooker of food products Oils used as cooking medium Up to 5,000 gal (18,927 l) of oil Arrangements: Conveyor Fryers Kettle Fryers Conveyor Fryer Placed in large industrial manufacturing environments Kettle Fryer 3

What are Industrial Oil Cookers Configuration Movable covers, or hoods, that may be hydraulically operated Hood is closed during system operation, but occasionally opened for routine maintenance Exhaust Stacks connected on top of hood Cooking Methods Conveyor Fryer Heated indirectly by exchanging heat with a heat transfer fluid or steam Heated directly by gas/oil fired radiant tubes beneath pan or flame impingement on the bottom of the pan Kettle Fryer 4

Fire Hazard Fire Classification Class K Cooking Oil Combustible Liquid Class IIIB Tested with canola oil Comparable oils: Olive Oil Corn Oil Flash Point Temperature at which the vapour and air mixture lying just above the liquid fuel s vaporizing surface is capable of supporting a momentarily flashing propagation of a flame when prompted by a quick sweep of a small gas flame pilot near the surface Auto-ignition Temperature Minimum temperature at which the mixture of a vapour (or gas) and air is self-igniting 5

Fire Risk Primary Cooking Area The Primary Cooking Area consists of the pan area under the hood containing heated oil where general cooking takes place. Highest Probability for fire events due to product Paddles, Drums, & Conveyors Movable Hoods 6

Fire Risk Primary Cooking Area 7

Fire Risk Take Out Area The Takeout Area consists of the area in which processed or cooked food is removed from the fryer, typically via a conveyor. High Probability for fire events due to cooked product and oil soaked crumbs 8

Fire Risk Take Out Area 9

Fire Risk Fines Box The Fines Box consists of the equipment utilized to filter the oil during continuous operation. 10

Fire Risk Fines Box 11

Fire Risk Exhaust Stack The Exhaust Stack(s) consists of the ductwork utilized to remove the gases and vapours generated during the cooking process from the primary cooking area and possibly the fines box. 12

Fire Risk Exhaust Stack 13

Challenges 14

Challenges Insurers view Significant risk potential Material damage Consequential loss Large recent claim history Operators view Rapid suppression Minimal infrastructure impact Quick recovery 15

Challenges Agent CO2 Water Spray Water Mist Reference Advantages Disadvantages NFPA 12 Established FM 7-20 Prescriptive Economic Thermal Shock Flood Risk High Water Consumption FM 5560 /NFPA 750 Infrastructure High Cooling Effect H²O Consumption Expandable Small Footprint Health & Safety Issues Finite Supply/Downtime Reduced Cooling Effect Not supported by FM FM Global Property Loss Prevention Data Sheet 4-11N, Carbon Dioxide Extinguishing Systems Appendix B, B-1 Commercial/Industrial Food Processing Deep-Fat (Hot Oil) Cookers Protection of industrial oil cookers is covered by FM Global Loss Prevention Data Sheet 7-20, Oil Cookers. Carbon dioxide protection of industrial oil cookers is not recommended by FM Global given the limited cooling capacity of carbon dioxide and its questionable based on reported loss experience 16

Industrial Oil Cooker Approval Fire Test Protocol 17

Approval Protocol Fire Testing per FM 5560 Appendix J: Fire Tests for Water Mist Systems for the Protection of Industrial Oil Cookers Primary Cooking Area Dimensions Mock-Up A: 8.0 ft (2.4 m) wide by 8.0 ft (2.4 m) long Mock-Up B: 8.0 ft (2.4 m) wide by 16.0 ft (4.8 m) long Mock-Up C: 8.0 ft (2.4 m) wide by 24.0 ft (7.2 m) long Test Mock-Up Hood Position 1 A Up 2 A Down 3 B Up 4 B Down 5 C Up 6 C Down (1 x L) (2 x L) (3 x L) We have proved infinite length scalability through fire testing; the results suggest there is no trend between fryer length and rapid extinguishment reliability. 18

Approval Protocol Fire Test Approval Criteria Extinguish AIT fire inside oil cooker mockup, regardless of hood position Extinguish all open flames within 1-minute of system discharge Cool oil so its average temperature is below the oil s flash point 600oF (316oC) within two minutes of system discharge Design Duration shall be twice the cooling time to get below Flash point, or 10 minutes, whichever is greater (be aware of potential spill over) No excessive fire flare-ups, micro explosions of oil reacting with water, or splashing of burning oil 19

Approval Protocol TFPP Fire Tests More than 50 full-scale fire tests were performed 14 tests were witnessed by FM Global in Marinette, WI 20

Approval Protocol 21

Approval Protocol 22

Approval Protocol 23

Approval Protocol 11131-T20121212-2 700 AIT 300 Activation Extinguishment 650 250 600 200 550 150 Avg Oil Temp Max Oil Temp 500 Nozzle Pressure [PSIG] Average Oil Temp [F] Flame 100 Autoignition Temp Flash Point Milestones 450 50 Nozzle Pressure 400 0-120 -60 0 60 120 180 Elapsed time [sec] 24

Approval Protocol Component Approval: Strength Discharge Co-efficient Corrosion Resistance Vibration Rough handling Extreme temperature exposure Vitally important for challenging environments such as industrial oil cookers 25

Approval Protocol 26

Industrial Oil Cooker Case Studies 27

Case Study One Multi-national snack manufacturer Arson total facility loss Insurance lead Full facility protection 17 Fryers Central water supply Pump-based system with directional valves but flow capability of all fryers at once! 28

Case Study One 29

Case Study Two Multi-national Food manufacturer Infrastructure upgrade No civil infrastructure available Water Supply Stand-alone Tank No Power Supply available 30

Thank You 31