STREAMLINED & EFFICIENT

Similar documents
SPACE SAVING & EFFICIENT Zoneline Single Packaged Vertical Air Conditioners

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

Zoneline vertical packaged terminal air conditioners

Ge zoneline SinGle PackaGeD Vertical air conditioners Product Guide

PRELIMINARY NEW PRODUCT GUIDE. Zoneline Packaged Terminal Air Conditioners

all-season comfort GE Zoneline packaged terminal air conditioners New product introductions Spring 2010

We bring good things to life. Zoneline. Packaged Terminal Units PRELIMINARY

GE zoneline. Packaged Terminal Air Conditioners

Important Safety Information. Operating Instructions The Controls on Your Zoneline Care of Product

built-in comfort GE built-in air conditioners New product introductions January 2010

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

Air Conditioners. Zoneline Vertical. GEAppliances.com

Important Safety Information. Operating Instructions The Controls on Your Zoneline Care of Product

GE Zoneline packaged terminal air conditioners. AZ41/ contract sales architects and engineers data manual

GE Zoneline packaged terminal air conditioners contract sales architects and engineers data manual

TECHNICAL SERVICE GUIDE

Air Conditioners. Zoneline.

built-in comfort GE built-in air conditioners and heat pumps

UseandCare & Installation Guide

room air conditioners #1 preferred brand of room air conditioners.

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

E Z S E R I E S " W X 16" H

Technical Service Guide

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

Air ConditionersSafety Instructions

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

ARCHITECTS AND ENGINEERS DESIGN DATA MANUAL

We bring good things to life. GE Room Air Conditioners The 1997 Line

PTW 42 Series 230/208 VOLT

Commercial High-Efficiency Condensing Units

THRU-THE-WALL AIR CONDITIONERS

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Service Instructions

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Room Air PRODUCT CATALOG. comfort, room by room

Packaged Terminal Air Conditioner (PTAC)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

52C 52C and 52P SERIES OWNER S MANUAL PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS. 7,000-15,000 Btuh

Concealed Ducted Split Series R-407C MBH

PACKAGE AIR CONDITIONER

Geniuses at work. Residential Mini Splits

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

High Heat COP. High/Low Stage

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

MAC N-407 Air-Cooled Chiller

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

13 GEP A L P - 1 A

Technical Specifications

Product Profile SINGLE PACKAGE VERTICAL AIR CONDITIONERS. Features

R4H4. Product Specifications

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

Single Package Vertical Air Conditioners

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

AE/AH R410A Window Air Conditioners & Heat Pumps

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units

Single Package Vertical Air Conditioners

Product Information and Technical Guide

13 SEER CONDENSING UNITS & AIR HANDLERS

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

RGE 13 A T - 1 A

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

PTAC 2017 Air Conditioner Collection

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

Service Manual A SERIES. Single Package Vertical Air Conditioning System For Years 2009 and *(Electronic Control)

Service Manual R410A Models

GE AIR CONDITIONER ACCESSORIES Split System/Built-In/Window/Zoneline Models

Packaged Terminal Air Conditioners & Heat Pumps

GREEN REFRIGERANT R-410A

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

OWNER S MANUAL PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

operating and maintenance instructions

Packaged Terminal Air Conditioner (PTAC)

MACH N-407 Heat Pump Air-Cooled Chiller

GFT14ESSMWW GE 4.1 Cu.Ft. Stainless Steel Capacity 24" Ventless Condenser Frontload Electric Dryer

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

PAJ3. Product Specifications

A 14 SEER Heat Pump with R---410A Refrigerant Series

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

Packaged Terminal Air Conditioners. SG Series. Efficient and reliable for the lowest cost of ownership. More efficient. More reliable.

R4H4. Product Specifications

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

E3EH-xxx-H Series E3EB-xxx-H Series

Transcription:

STREAMLINED & EFFICIENT Zoneline Packaged Vertical Air Conditioners

2 WHY GE ZONELINE VERTICAL AIR CONDITIONERS?

SLEEK LOOK. MINIMAL SPACE. Vertical design leaves more usable floor space and allows for installation in a closet or out-of-sight area. With proper ducting, a single unit can serve multiple rooms. LOW ENERGY COSTS. ONGOING SAVINGS. Zonelines are some of the most efficient vertical air conditioners in the industry. The more energy efficient the unit, the lower the utility bill and that means a better bottom line for you. PEACE AND QUIET Every component is engineered to provide whisper-quiet cooling performance, creating perfectly comfortable and relaxing environments. 3

VERTICAL ZONELINE CHART ELECTRIC RESISTANCE HEAT HEAT PUMPS 230/208V MODELS AZ85E09DAC AZ85E12DAC AZ85E18DAC AZ85H09DAC AZ85H12DAC AZ85H18DAC Cooling (BTUH) 9,000/8,800 11,700/11,500 17,900/17,700 8,800/8,600 11,700/11,500 17,700/17,400 EER (BTUH/Watt) 10.5/10.5 10.6/10.6 9.3/9.3 10.5/10.5 10.6/10.6 9.1/9.1 Dehumidification (pints/hr.) 2.5 3.2 5.0 2.5 3.2 5.0 Heating (BTUH) 8,200/8,000 10,400/10,300 16,700/16,300 COP @ 47 3.4/3.4 3.4/3.4 3.0/3.0 Voltage (V) 230/208 230/208 230/208 230/208 230/208 230/208 Unit Width (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Depth (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Height (in.) 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 Indoor CFM (Hi/Med/Low) 520/460/360 590/500/380 600/520/400 520/460/360 590/500/380 600/520/400 265V MODELS AZ85E09EAC AZ85E12EAC AZ85E18EAC AZ85H09EAC AZ85H12EAC AZ85H18EAC Cooling (BTUH) 9,000 11,700 17,900 8,800 11,700 17,800 EER (BTUH/Watt) 10.5 10.6 9.3 10.5 10.6 9.3 Dehumidification (pints/hr.) 2.5 3.2 5.0 2.5 3.2 5.0 Heating (BTUH) 8,200 10,400 16,400 COP @ 47 3.4 3.4 3.0 Voltage (V) 265 265 265 265 265 265 Unit Width (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Depth (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Height (in.) 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 Indoor CFM (Hi/Med/Low) 520/460/360 590/500/380 600/520/400 520/460/360 590/500/380 600/520/400 See Power connection kits section on page 5 for Universal Heater information. 265 Volt available by special order. Specifications subject to change. 4

VERTICAL ZONELINE BASICS MINIMUM CLEARANCES Front Allow 4" in front of unit. Note that plenum may protrude into closet, depending on exterior wall thickness. Sides Allow 3" on each side of unit. Platform An 8" 12"-high field-supplied platform is recommended for drain access. Side-access closets Allow 5" on the side where access is required and 5" in front of unit. VERTICAL VIEW OVERALL UNIT DIMENSIONS 32-1/4 H x 23-1/8 W x 23-1/8 D Closet Door POWER CONNECTION KITS Required on all vertical Zoneline chassis (see chart to the right). The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a power cord kit would be used; if the unit is to be permanently connected, a direct connect kit would be used. RAK3152/3202/3302 230/208-volt cord connection kit Power connection kits See specification sheet for heater KW and branch circuit ampacity. 230/208 VOLT LINE CORD CONNECTED UNITS Power Connection Kit RAK3152 RAK3202 RAK3302 Heater KW 2.61/2.19 3.42/2.87 4.81/4.07 Min. circuit amps 15 20 30 Recommended protective device 15 amp time-delay 20 amp time-delay 30 amp time-delay 230/208 VOLT DIRECT CONNECTED UNITS Power Connection Kit RAK4157 RAK4207 RAK4307 Heater KW 2.61/2.19 3.42/2.87 4.81/4.07 Min. circuit amps 15 20 30 Recommended protective device 15 amp time-delay 20 amp time-delay 30 amp time-delay 265/277 VOLT DIRECT CONNECTED UNITS Power Connection Kit RAK5157 RAK5207 RAK4307 Heater KW 2.71 3.55 5.03 Heater Amps 10.6 13.9 19.6 Min. circuit amps 15 20 30 Recommended protective device 15 amp time-delay 20 amp time-delay 265/277-volt units and line cord kits available by special order 30 amp time-delay Specifications subject to change. 5

VERTICAL ZONELINE DETAILS NOMENCLATURE The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features included on the unit. When specifying or ordering the Zoneline chassis, use of this nomenclature will assure receiving the correct unit. A Z 8 5 H 1 8 D A C Zoneline Chassis series 85=single package vertical unit Unit type E= cooling with electric resistance heat H= heat pump with electric resistance heat Nominal cooling capacity* Universal 09=9,000 BTUH cooling power connection 12=12,000 BTUH cooling 18=18,000 BTUH cooling Special features Voltage/Phase/ Frequency D= 230/208 Volt, single phase, 60 Hz E= 265 Volt, single phase, 60 Hz C=corrosion treated *Approximate see product specs for actual performance. 6

WARRANTY* For the period of One year From the date of the original purchase Five years From the date of the original purchase Second through fifth year From the date of the original purchase GE will replace *See written warranty for complete details. Any part of the air conditioner which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part. Sealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor, condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or workmanship. During this limited five-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part. Fan Motors, Switches, Heater, Heater Protectors, Compressor Overload, Solenoids, Circuit Boards, Auxiliary Controls, Thermistors, Frost Controls, ICR Pump, Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in materials or workmanship. During this additional four-year limited warranty, the customer will be responsible for any labor and related service costs. 7

GE APPLIANCES GE s commitment to appliances has never been stronger. Backed by an investment of more than $1 billion, that legacy continues. We re streamlining our manufacturing. Conducting more consumer research. Launching new product innovations. Creating more U.S. jobs. Advertising on a national scale. And delivering the support our partners need to succeed well into the future. The opportunity for growth has never been so promising. We re not just imagining. We re doing. GE Appliances Appliance Park Louisville, KY 40225 geappliances.com 2014 General Electric Company Pub. No. 20-X014 PC77458