Product Data BW9 WATER BOILER SERIES B

Similar documents
Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Suggested Specifications Prestige Excellence 110

Boiler & Water Heater

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Utica Boilers MAC Submittal

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

WM97+ Wall Mount Boiler

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Raypak Residential Products

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

G6RC Series TECHNICAL SPECIFICATIONS

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

GB Condensing Gas Boiler

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

iq1001, Gen II Submittal Data

GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. Models (Series B) BW9AAN BW9AAN BW9AAN000100

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Commercial Gas Water Heaters

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Raptor 320HB & 399HB Submittal Sheet

13 GEP A L P - 1 A

Cooling Capacity CFM in. w.c. (125 Pa)

Installation, Start-up, and Operating Instructions

Cooling Capacity CFM in. w.c. (125 Pa)

RG7D 1-Stage Heat Series

Wt. Lbs Model Number (BTUH) Hz

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Automatic Circulating Water Heaters

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Tankless Rack System

Cooling Capacity CFM range

Residential/Commercial Gas Condensing Tankless Models

NPE-A and NPE-S Condensing Tankless Water Heaters

FG7T (C and L Series)

UB Series 2 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. Models UB90-50 UB90-75 UB INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION MANUAL GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER. DUNKIRK BOILERS 85 Middle Rd. Dunkirk, NY

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration

Trade Price Book - 816

Date: Project #: Engineer: Prepared By: Bid Date:

Commercial Tankless Rack System

The WCGH High Efficiency Commercial Water Heater with Storage Tank

TECHNICAL SPECIFICATIONS

iq751/iq1001/iq1501 Specifications (Floor-standing units)

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Residential & Commercial

RGE 13 A T - 1 A

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

NPE-A and NPE-S Condensing Tankless Water Heaters

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

GB Condensing Gas Boiler

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

NPE-A and NPE-S Condensing Tankless Water Heaters

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

NPE-A and NPE-S Condensing Tankless Water Heaters

GMS9/GCS9 SERIES 93% AFUE

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

MERIT SERIES Downflow

NHB High Efficiency Condensing Boilers

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Transcription:

GAS --- FIRED CONDENSING WATER BOILER SERIES B Product Data Fig. 1 - Model 50-100 Series B Fig. 2 - Model 125-200 Series B C US Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. A12524 A12523 The is a gas fired direct vent condensing hot water boiler with cast aluminum heat exchanger sections. A revolutionary cast aluminum heat exchanger means better heat transfer and thermal storage than similarly sized cast iron boiler, which results in higher efficiency. The heating system water absorbs large amounts of heat from the cast aluminum heat exchanger, cooling the flue gases and causing condensation. Sealed combustion, premix gas burner, and low flame temperature means reduced CO and NOx emissions, which contribute to a cleaner and healthier environment. The, unlike other residential atmospheric and induced draft boilers, takes its combustion air directly from the outdoors (sealed combustion) and does not compete with building occupants for fresh air. Sealed combustion (also known as direct vent ) is the best way to obtain clean combustion air. The draft fan draws in the outside combustion air, then takes the cooler flue gases from the heat exchanger and provides a positive removal of the flue gases from the building through inexpensive and readily available PVC and CPVC pipes. FEATURES RANGE OF CAPACITIES - Seven sizes ranging from 50,000 through 200,000 Btuh input. 2012 DOE COMPLIANT - The boiler features a 2012 DOE compliant Hydrolevel Fuel Smart Hydrostat. The control monitors the water temperature and delays the burner starting until the residual heat has been transferred. This maximizes efficiency by turning on the burner only when needed. COMPLETELY PACKAGED - Each boiler comes fully assembled, including all controls (except thermostat and expansion tank). Factory pre-wired for quick connection of supplied circulator pump. Easily identified field connections for gas, electric, water and room thermostat. VENTING - This boiler is direct vented with PVC and CPVC pipe. ALUMINUM SECTIONS - These sections speed heat transfer to the boiler water. With faster thermal response, greater comfort and economy are achieved. PRE -MIX BURNER - Provides quiet operation and improved combustion efficiency. CONTROLS - UTEC Ignition Control manages operation of gas flow, ignition devices and supervision of safety components to provide superior combustion performance and protection. A factory installed low water cut-off is provided on all models. SECTIONS TESTED - Each section is hydrostatically tested per ASME Section H requirements. The maximum allowable working pressure is 50 psig for hot water boilers. PROPANE CONVERTIBLE - With factory approved conversion kit accessory.

MODEL NUMBER NOMENCLATURE B W 9 A A N 000 075 A B AA B Boiler Variations AA Standard Type of System W Water Combustion/Ignition 9 90% Direct Vent/Sealed Combustion Series Labeling A Common Unit Model Code Electrical A 110 to 125 60 Hz Heating Size Btu Input (x 1000) Fuel N Natural Gas P Propane Gas Cooling A12522 ACCESSORIES DESCRIPTION Filltrol Package (Up to 75,000 BTUH) Filltrol Package (Up to 150,000 BTUH) Filltrol Package (Up to 300,000 BTUH) High Limit Control Gas Conversion Kit, Combination Natural to Propane (-050, 0 to 10,000 ft.) Gas Conversion Kit, Combination Natural to Propane (-075, 0 to 5000 ft.) Gas Conversion Kit, Combination Natural to Propane (-075, 5001 to 10,000 ft.) Gas Conversion Kit, Combination Natural to Propane (-100, 0 to 10,000 ft.) Gas Conversion Kit, Combination Natural to Propane (-125, 0 to 10,000 ft.) Gas Conversion Kit, Combination Natural to Propane (-150, 0 to 10,000 ft.) Gas Conversion Kit, Combination Natural to Propane (-175, 0 to 10,000 ft.) Gas Conversion Kit, Combination Natural to Propane (-200, 0 to 10,000 ft.) Gas Conversion Kit, Combination Propane to Natural (-050, 0 to 10,000 ft.) Gas Conversion Kit, Combination Propane to Natural (-075, 0 to 10,000 ft.) Gas Conversion Kit, Combination Propane to Natural (-100, 0 to 10,000 ft.) Gas Conversion Kit, Combination Propane to Natural (-125, 0 to 10,000 ft.) Gas Conversion Kit, Combination Propane to Natural (-150, 0 to 10,000 ft.) Gas Conversion Kit, Combination Propane to Natural (-175, 0 to 10,000 ft.) Gas Conversion Kit, Combination Propane to Natural (-200, 0 to 10,000 ft.) Concentric Vent Kit 2 Concentric Vent Kit 3 NOTE: Accessory High Limit Control is a strap---on aquastat used as an auxiliary limit or revers acting circulator control. PART NO. KBAFP0101DNK KBAFP0201DNK KBAFP0301DNK KBAHL0101DNK KBANP2401DNK KBANP2501DNK KBANP2601DNK KBANP2701DNK KBANP1401DNK KBANP1501DNK KBANP1601DNK KBANP1701DNK KBAPN1501DNK KBAPN1601DNK KBAPN1701DNK KGAVT0701CVT KGAVT0801CVT 2

DIMENSIONS MODEL -50/75/100 CLEARANCES - IN. (MM) PART OF BOILER COMBUSTIBLE TOP 1 (25) LEFT SIDE 1 (25) RIGHT SIDE 11(279)* BASE 1 (25) FRONT 1 (25)* BACK 1 (25) INTAKE/VENT PIPING 0 NEAR BOILER HOT WATER PIPING 1 (25) *Service clearance requirement 24---in. (610 mm); front alcove clearance 18---in. (457 mm) A12525 3

SPECIFICATIONS UNIT SIZE 50 75 100 Sections 2 GAS CONTROLS Gas Valve Honeywell Inlet Size 1/2-in. Integrated Boiler Control UTEC, Hot Surface Burner Stainless Alloy Natural Gas 1 WATER CONTROLS Limit Control Hydrolevel, Fuel Smart Hydrostat Limit Control Range 100-190_F Pressure Relief Valve Setting 3/4-in. 30 Psig Drain Valve 3/4-in. Air Vent 1/8-in. CIRCULATOR Pump Taco 007 Full Load Current.76 amps Flange Size FPT 1-1/4-in. 4

DIMENSIONS MODEL -125/150/175/200 OPENING FOR RELIEF VALVE DISCHARGE PIPE OPENING FOR AIR VENT AND EXPANSION TANK CONNECTION JUNCTION BOX FOR 120V. POWER & 24 V THERMOSTAT LEADS STANDARD SUPPLY & RETURN OPENINGS 1 1/4 NPT CONNECTIONS PROVIDED INSIDE BOILER CABINET. VENT CONNECTION (2 CPVC) COMBUSTION AIR INTAKE FITTING (2 PVC) TOP 32 5/16 20 1/8 GAS SUPPLY OPENING (1/2 NPT) 40 1/4 25 1/4 4 7/16 6 1/4 LEFT SIDE VENT TEE (2 CPVC) FRONT RIGHT SIDE BACK CONDENSATE DRAIN FITTING (1/2 PVC) LEVELING FEET A04049 CLEARANCES - IN. (MM) PART OF BOILER COMBUSTIBLE TOP 1 (25) LEFT SIDE 8 (203)* RIGHT SIDE 1 (25) BASE 1 (25) FRONT 0(0)* BACK 1 (25) INTAKE/VENT PIPING 0(0) NEAR BOILER HOT WATER PIPING 1 (25) *Service clearance requirement 24---in. (610 mm); front alcove clearance 18---in. (457 mm) SPECIFICATIONS UNIT SIZE 125 150 175 200 Sections 1 GAS CONTROLS Gas Valve Honeywell Inlet Size 1/2-in. Integrated Boiler Control UTEC, Hot Surface Burner Stainless Alloy Natural Gas 1 WATER CONTROLS Limit Control Hydrolevel, Fuel Smart Hydrostat Limit Control Range 100-190_F Pressure Relief Valve Setting 3/4-in. 30 Psig Drain Valve 3/4-in. Air Vent 1/8-in. CIRCULATOR Pump Taco 007 Full Load Current.76 amps Flange Size FPT 1-1/4-in. 5

CIRCULATOR CURVE 12 1 WATER FLOW M 3 /H 2 3 4 5 10 TOTAL HEAD FEET 8 6 4 3 2 1 TOTAL HEAD METERS 2 0 4 8 12 16 20 24 WATER FLOW GPM A12448 ELECTRICAL DATA ALL MODELS Voltage Hertz Phase 120 60 1 Minimum Branch Circuit Wire Size (AWG) 14 MaximumFuseSize(Amps) 15 Control Circuit Power Available 40va @ 24v MODEL GAS TYPE MAX INPUT (BTUH) RATINGS AND CAPACITIES HEATING CAPACITY (BTUH) AFUE % NET RATINGS (BTUH) BOILER WATER CAPACITY (GALLONS) APPROXIMATE SHIP WEIGHT (LBS.) AAN050* Natural 50,000 45,000 90.0 39,000 2.6 220 AAN075* Natural 75,000 68,000 90.0 59,000 2.6 220 AAN100* Natural 100,000 90,000 90.0 78,000 2.6 220 AAN125{ Natural 125,000 113,000 90.0 98,000 3.0 284 AAN150{ Natural 150,000 134,000 90.0 117,000 3.0 284 AAN175{ Natural 175,000 158,000 90.0 137,000 3.0 284 AAN200{ Natural 200,000 180,000 90.0 157,000 3.0 284 *Boilers are factory equipped for operation at elevations from 0 to 5,000 ft. (1,524 M) above sea level. For elevations from 5,000 ft. (1,524 M) to 10,000 ft. (3,048 M) above sea level, gas manifold pressure needs to be adjusted based upon calorific value of supply gas. AAN075 installations firing on Propane at elevations from 5,000 ft. (1,524 M) to 10,000 ft. (3,048 M) above sea level also require an orifice change as well as gas manifold pressure adjustment. Canada --- Boilers are factory equipped for operation at elevations from 0 to 4,500 ft. (1,372 M) above sea level. Contact Provincial Authority having jurisdiction for installations above 4,500 ft. (1,372 M) above sea level. {Ratings shown are for sea level applications. Boiler automatically derates input as altitude increases. No alterations to boiler are required for altitudes up to 1000 ft. (305 M). Combustion analyzer required for input adjustment at all altitudes. Refer to installation instructions. Copyright 2013 CAC/BDP. S 7310 W. Morris St. S Indianapolis, IN 46231 edition date: 06/13 Catalog No: SS --- A --- 02 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: SS --- A --- 01 6