SMARTWALK DEMENTIA WANDERING SYSTEM

Similar documents
Wander-Alarm DOORWAY SENSORS

Wireless Call Point ( )

MEDI-MINDER USER MANUAL

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

Secure WANDERING INSTALLATION AND USAGE GUIDE

MEDI-LINK USER MANUAL

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

CORPORATION PTY LTD MEDI-LINK

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

ERS-3600B. PERS-3600B Personal Emergency Reporting System

Silent Alert Fire Safe System

New Silent Alert Fire Safe System

Finally, an affordable wireless call bell system for smaller facilities

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Beacon 800 Gas Monitor Operator s Manual

1125 PIR Motion Detector

ezone Alert System ezone is a UK designed and manufactured care alerting system unlike any other comparably priced system.

TRUST WIRELESS ALARM SYSTEM 200S

P162B Radio PIR Motion Detector

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Fire / CO Alarm Interface

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

SMARTWIRE MKII INSTALLATION MANUAL HARD-WIRED NURSE CALL SYSTEM. SmartWire MK2 Nurse Call Installation Manual v1.8.doc

Sentry Freedom Wireless Emergency Call

Installation & Programming Guide

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Alert-it Care Systems

PTE0705 Electric Fence Monitor

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Clofield Limited. Product Data Sheets. Paging System. Care Call. Preventative monitoring for homecare... Wireless alerting system for Carers

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

GSM RFID VOICE Alarm System

Premium 8 Zone Wireless Alarm Kit

Touchpad Exit Controller Administration Guide

Medi-Minder Guardian USER MANUAL

1126 Series Ceiling Mount PIR Motion Detector

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Advanced DIGITAL Wired PIR Motion Detector

5000 SERIES 8 ZONE INSTRUCTION MANUAL

ZLM4 OEM Technical Manual

THE BELLMAN & SYMFON WAY Visit technical training

Deaf & Hearing Impaired RadioLINK Alarm System

X64 Wireless Training

KT-100 Door Controller

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

Exit Stopper. STI-6400 Series

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

2G & 3G GSM Door Contact Alarm

HRX Technical Manual. Version 1.2

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

MEDI-MINDER USER MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

"Pegaso" wireless alarm system

Telecare Equipment Guide

2G & 3G GSM Portable PIR Alarm

Wireless Alarm system s manual

Challenger10 Users Manual

CC408. Quick Reference Guide Solution 880

MD12-1 Vehicle Loop Detector

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

21-light Remote Annunciator. Owner s Manual

INSTALLATION INSTRUCTIONS

General Routing Interface

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

FEC400 Series. Installation Manual

Solution Ultima 862 Operators Manual ISSUE 1.10

Pioneer-R16 Gas Monitor Operator s Manual

Wireless ShatterPro Acoustic Sensor Installation Instructions

Challenger Series Users Manual

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

Power Wave Zone Alarm Panel V8.5. Installation Manual

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Quick Touch Pendant User Guide

600 Range Dialer Installation Manual. Version 1.0

Exit Stopper. STI-6400 Series

9 100% Recycled Paper

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Accessible Toilet Alarm

Addendum for STI-6406 with Dual Access Control

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

STANDARD FEATURES SPECIFICATIONS

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

Fratech Multipath-IP


Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Model 17A00 Expansion Enclosure

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

169MHz Telecare Devices Universal Transmitter

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

Beacon 110 Gas Monitor Operator s Manual

Digital Electronic Thermostat With RF

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Transcription:

A division of NESS CORPORATION PTY LTD SMARTWALK DEMENTIA WANDERING SYSTEM SWD Door Responder SWD Resonator SWD-PET (Sold Separately) SWD-PET-BAND (Sold Separately) INSTALLATION MANUAL

1. CONTENTS 1. CONTENTS...1 2. INTRODUCTION...2 2.1 Overview...2 2.2 Handling Alarms...2 2.3 Fitting a Transmitter to a Patient...2 2.4 Removing a Transmitter from a Patient...2 2.5 Maintenance of Transmitters...2 2.6 Multiple Patients...2 2.7 Replacement Wristbands...2 3. SYSTEM COMPONENTS...3 3.1 SmartWalk Resonator...3 3.2 SmartWalk Door Responder...4 4. SYSTEM OPERATION...5 4.1 Normal Operation...5 4.2 Resonator...5 4.3 Door Responder...6 4.4 Wrist Transmitter Battery Life...6 4.5 Adjustment of Resonator Activation Field (10K Trimpot)...6 5. SYSTEM INSTALLATION...6 5.1 Location Of Equipment...6 5.2 Detailed Wiring Diagram...9 5.3 Connecting Indicators (Light and Buzzer)...10 5.4 Operating the Resonator from 12V DC Only...10 5.5 Powering the Door Responder (12V DC)...11 5.6 Connecting a Door Lock System...11 5.7 Connecting a Universal Wireless Transmitter...12 5.8 Integrating to a SmartWire Nurse Call System...13 6. TROUBLESHOOTING...14 1

2. INTRODUCTION The SmartLink System is a means of detecting when a dementia patient has an opportunity to wander from a designated area and become missing. 2.1 Overview A small Radio Transmitter is attached to the wrist of the wanderer and Door Stations are mounted near each door that lead to unsafe or restricted areas. If a Patient wearing a Wrist Transmitter opens a monitored door, an alarm will sound, warning staff of the breach. For security at night the SmartWalk system can be switched to NIGHT MODE, where any opening of a monitored door will alert staff. If a monitored Patient wearing a Wrist Transmitter opens a monitored door, the Door Station indicates the alarm via a buzzer and alarm light. The alarm can also be extended to a Nurse Station, to operate a beeper, flashing lights, pagers etc. For multiple door installations a total of 200 doors can be monitored through SmartLink s unique gateway receiver/decoder system, linking RF transmitters to each door. 2.2 Handling Alarms Go to the door indicated by the Alarm and look for any of your monitored patients. It is possible that the patient opened the door, then turned around and went back inside. Alternatively a monitored patient may have been standing near the door when someone else opened it. Look for any of your monitored patients near the door. When the patient has been located and brought back inside, press the CANCEL button on the Door Responder. You may cancel the alarm as soon as you get to the door, however this may cause the alarm to sound again when the patient is brought back through the doorway. 2.3 Fitting a Transmitter to a Patient The Transmitter is fitted to the Patient by slipping the new band into the slot in the back of the Transmitter and snapping the retaining clip onto both ends of the band. The excess band may then be cut off with scissors. 2.4 Removing a Transmitter from a Patient Removal of the Transmitter requires cutting the band, so a new band and clip are required for each fitting. 2.5 Maintenance of Transmitters The Transmitters are fully sealed which means they are resilient to wet conditions and are usually only damaged by physical abuse or through excessive environmental temperature (e.g. in a tumbledrier) which can melt the plastic case. 2.6 Multiple Patients The SmartWalk System works with as many Transmitters as you have dementia patients. 2.7 Replacement Wristbands Your purchasing department may obtain packs of ten replacement bands with clips by faxing or emailing an order to SmartLink International. 2

3. SYSTEM COMPONENTS The SmartLink SmartWalk Dementia Wandering Alarm System must be installed by a qualified technician. 3.1 SmartWalk Resonator Specifications Dimensions (W x L x D): 350mm x 250mm x 60mm Mountable on a non-metallic wall Generates an alternating magnetic field at 200khz Null transmit area parallel to mounting surface Adjustable range (Warning: Do Not Adjust. Refer to SmartLink International) Description The Resonator is part of the SmartWalk door kit SWD. The Resonator is connected via two wires to the SWD-Door Responder. The Resonator mounts opposite the SWD-Door Responder (see Section 5.1 Diagrams) The Resonator also has optional battery backup facilities (No Longer Available). Operation The Resonator creates a magnetic field of approximately 8-10 feet. Once a SmartWalk Wristwatch Transmitter SWD-PET comes within this field, it wakes up the internal transmitter, which then sends a signal to the Door Responder. Applications Retirement Villages, Nursing Homes, Hostels, Hospitals. 3

3.2 SmartWalk Door Responder Specifications Dimensions 200mm L x 110mm W x 50mm D ABS Plastic construction Relay output N/O contact Momentary or latching Optional Transmitter board (Part No. 100-529) Optional Door Locking Function Description The Responder is part of the SmartWalk door kit SWD. The Door Responder is connected via 2 wires to the SWD-Resonator. The Door Responder mounts opposite the Resonator (see Section 5.1 Diagrams). Operation The Door Responder receives a signal from a SmartWalk Wristwatch (SWD-PET). The Door Responder then looks to see if the door has been opened (the reed contact broken). If both events have occurred, the Door Responder then triggers a response by closing the relay contact and sending a message to displays and/or paging. Other options of response are also available. The nurse then attends the call and retrieves the patient from the restricted area and cancels the Door Responder. Applications Retirement Villages, Nursing Homes, Hostels, Hospitals. 4

4. SYSTEM OPERATION 4.1 Normal Operation The Wrist Transmitter (SWD_PET) is normally in power-down mode (not transmitting) until the wanderer approaches a monitored door where a Resonator is located together with a Door Responder (each mounted on either side of the door at least 1.5 meters apart). At a predetermined distance from the door the Wrist Transmitter is activated by a magnetic field being transmitted by the Resonator either by opening a door (Reed Switch) or PIR detector (proximity alert). The distance at which the Wrist Transmitter is activated can be controlled by adjustment of the field from the Resonator. In locations where the door is frequently in use (e.g. the front entrance), the wanderer would be almost right in the doorway before the alarm is activated. Once activated, the Wrist Transmitter will transmit an RF signal continually until the Wrist Transmitter leaves the immediate area (beyond the range of the activating field of the Resonator). While the Wrist Transmitter stays in the triggering area of the Resonator, the Wrist Transmitter will be detected by the Door Responder s RF receiver section. If the door is now opened, while the Door Responder is picking up data from the Wrist Transmitter, the Door Responder will go into alarm. The Door Responder will attract the attention of staff either locally by internal beeper, or communicating via an optional RF transmitter, or as an alarm on a SmartWire Nurse Call System. 4.2 Resonator The Resonator is housed within an ABS vacuum formed two (2) piece housing which is designed for attachment to a wall using its internal mounting brackets. The front cover can be removed by removing two small screws. The Resonator obtains power either from a 16 VAC plug pack (connected to a dedicated 240 VAC GPO) or 12 volts DC from the Nurse Call System. Connection is made to on-board terminals within the enclosure. The plug pack is the preferred option as voltage drop in cabling of nurse-call systems combined with the current drain of the SmartWalk System is sometimes unsatisfactory. The Resonator has terminals for a standby battery backup (optional) which has sufficient capacity to maintain operation of a Door Responder and Resonator (one of each) for a period of at least four (4) hours, should the mains fail. The battery is maintenance free and will automatically recharge when the AC mains are restored. The Resonator has an AC power monitoring facility and will alert via a flashing LED (an on-board audible alarm) if the AC mains should fail (this of course only applies if backup battery is fitted). The alarm frequency is such that it will be noticeable when activated but can be tolerated if the AC failure is prolonged e.g. Electrician re-wiring on the circuit etc. This alarm will automatically reset when the AC mains are restored. Access to the Door Responder power supply and 16VAC plug pack is provided via entry holes in the rear of the housing. The Door Responder has a single green LED used to indicating three functions: 1. Off (no light/black) No supply power (no battery) 2. Green Steady AC mains present 3. Green Flashing AC mains failure (battery present) 5

4.3 Door Responder The Door Responder is housed within a plastic case screwed together, designed for attachment to the wall using integral keyhole screw mounting. The Door Responder obtains 12 Volt D.C. power from the Resonator, which obtains its power from a 16 Volt AC 1.5 Amp plug pack power supply inserted into a 240 Volt general-purpose outlet. The reed switch on the monitored door connects to terminals on the Door Responder. 4.4 Wrist Transmitter Battery Life The power down feature of the Wrist Transmitter provides a long service life. The actual service life will depend upon the amount of activations, i.e. how many times and for what period the wanderer goes to a monitored door. We expect a minimum service life of at least 12 months and up to two years. The only limiting factors, apart from the number of activations, would be physical damage to the Wrist Transmitter housing. The Wrist Transmitters are common coded and any Door Responder will detect any Wrist Transmitter. 4.5 Adjustment of Resonator Activation Field (10K Trimpot) The Resonator controls the area where the Wrist Transmitter is activated, and hence sets the operating area of the Wrist Transmitter and Door Responder. Warning: Adjustment of the square blue 10k Trimpot WILL NOT increase the range of the SmartWalk System, adjustment of the square blue 10k Trimpot will only changes the waveform. If moved from the position set at SmartLink, it will only reduce the range due to the distortion of the waveform. 5. SYSTEM INSTALLATION 5.1 Location Of Equipment The Door Responder and Resonator should be installed at a height of approximately 1.5 meters (5 feet) on either side of the door, or with the Resonator near the door and the Door Responder 1.5 meters away. The two units must be at least 1.5 meters (5 feet) to 2.20 metres (7 feet) apart. WARNING: DO NOT MOUNT THE RESONATOR AND RESPONDER SIDE-BY-SIDE or NEAR ANY TRANSMITTING DEVICES (EG. PAGING TRANSMITTERS), as this will reduce the effective area of the magnetic field resulting in an insufficient reception range. WARNING: DO NOT MOUNT THE RESONATOR ON A CONDUCTING METAL WALL/FRAME or WITHIN 1 METRE FROM THE EXIT SIGN, as this will affect the transmission of the magnetic field by blocking its path. WARNING: DO NOT MOUNT THE RESONATOR HORIZONTALLY (EG. CEILING), as this will affect the transmission of the magnetic field. A 16 VAC 1.5A Plug Pack is provided which is connected to the terminals marked AC in the Resonator, which has a 12 VDC output to power the Door Responder. The Reed Switch is normally fitted at the top edge of the doorframe with the terminals on the top connected to the Door Responder and the magnet on the door in line with the door handle. Note that a normally closed Reed Switch is required, i.e. the reed switch is closed when the door is closed (this is the general type of Reed Switch available). Where a door switch is not practical (e.g. in a corridor), a Passive Infra Red (P.I.R) Movement Detector can be used. Most P.I.Rs are fitted with a normally closed relay contact that can be used as a replacement for a Reed Switch. 6

Example A: Single Door Installation Reed Switch Power Supply (16 V AC 1.5A) Resonator Door Responder 1.5m - 2.2m Patient Wrist Transmitter (Sold Separately) 1.5m - 2.2m Example B: Single Door Installation Power Supply (16 V AC 1.5A) Reed Switch Resonator Door Responder 1.5m - 2.2 m Patient Wrist Transmitter (Sold Separately) 1.5m - 2.2m 7

Example C: Double Door or Sliding Door Installation Power Supply (16 V AC 1.5A) Resonator Reed Switch Door Door Responder 1.5m - 2.2m Patient Wrist Transmitter (Sold Separately) 1.5m - 2.2m Example D: Wide Double Sliding Door Installation Resonator Reed Switch Reed Switch Sliding Door Sliding Door Responder Door Door Responder 1.5m - 2.2m Patient Transmitter (Wrist Band) 2.2 m (max) 8

5.2 Detailed Wiring Diagram TO COIL + BATTERY BACKUP BATTERY (optional) +12V OUT RESONATOR OUTPUT LEVEL VOLTAGE SET FOR BATTERY CHARGING RESONATOR 16 VOLT AC PLUG PACK 16V AC PLUG PACK NIGHT REED GND 12V GND RESET N/O COMM B A B - L REMOTE LIGHT and/or BUZZER (both optional) OS ON RESPONDER Link Selects ONE SHOT MODE or ON MODE: ON mode: Relay operates and holds until ALARM RESET button is pressed. ONE SHOT mode (OS): Relay operates and holds for 15 seconds before releasing. Call must still be cancelled using the responder ALARM RESET button. Note: The link setting only affects the RELAY OUTPUT of the responder, not the radio link output. 9

5.3 Connecting Indicators (Light and Buzzer) The SmartWalk System can be connected to a light and buzzer at a remote location, for example a Nurses Station. See Detailed Wiring Diagram on Page 9. 5.4 Operating the Resonator from 12V DC Only If the SmartWalk Resonator is operated from a 12 Volt DC supply (e.g. from an existing non- SmartLink Nurse Call System) there are two possible problems to consider: As the unit normally operates at 13.7 volts DC, there WILL be a reduction in the Resonators Field range. As no AC supply is used, the Mains Fail alarm is not applicable and must be disabled. To do this, remove the resistor from the Resonator PCB as described in the diagram below. Then connect the 12 Volt DC Supply to the Battery Terminals. Note that the Door Responder should be connected to the usual terminals. Connect 12 Volt DC Supply Here Remove Resistor (middle of three) WARNING: Do Not Adjust 10K Trimpot Note: 2007 Onwards Has been removed for Optimum System Performance. 10

5.5 Powering the Door Responder (12V DC) A SmartWalk Door Responder operates from a 12 Volt DC supply from the Resonator. An alternative source can and should be used when: A Resonator is not required (e.g. when monitoring a door for Night Mode only) Note that the Wandering Patient feature will not be available on this door. To connect an alternative 12 Volt DC supply, connect the supply wires to the 12V and GND terminals, as indicated in the picture below. Reed Switch On Door Connect 12 Volt DC Supply here from Resonator Door Lock Adaptor Board X8 Link = ON X6 Link = ON 5.6 Connecting a Door Lock System An optional 12V electric door strike can be installed with the SmartWalk system using the door lock adaptor on the Door Responder PCB. When used to operate a door lock system, the Door Responder will detect a patient wearing a Transmitter that wonders into its range. When this occurs the door will automatically lock until the patient has moved away from the door, returning it to the normally unlocked condition. Wire the Door Lock Adapter (on Door Responder) to Door Strike as follows: RESPONDER ON OS NIGHT REED GND 12V GND DOOR LOCK ADAPTER N/C COM N/O RESET N/O COM B A REED SWITCH ON DOOR 12 VOLT DC PLUG PACK or 12 VOLTS FROM RESONATOR 12 VOLT ELECTRIC DOOR STRIKE (MAX 200mA, ENERGISED = LOCKED) 11

5.7 Connecting a Universal Wireless Transmitter Interfacing with a wireless transmitter can be achieved using the Door Responder unit in conjunction with operation of an RF receiving Medi-Call Dialler. Below is an example for wiring a wireless reed/vibration sensor (product code 100-112) to the SmartWalk Door Responder. Note that the Door Lock adapter board is not present, providing access to the 4-block terminal directly on the Door Responder PCB. REED SWITCH ON DOOR 12 VOLT DC PLUG PACK or 12 VOLTS FROM RESONATOR Reed Switch (Part No. 100-529) NIGHT REED GND 12V GND RESET N/O COMM B A WIRELESS TRANSMITTER OS + ON _ RESPONDER 12

5.8 Integrating to a SmartWire Nurse Call System The SmartWalk System can be integrated with a SmartWire hard-wired Nurse Call System. The Door Responder connects directly to the systems four-wire bus, which will supply the Door Responder and Resonator with power. Once connected, the SmartWalk system can produce an alarm similar to a TYPE B call point, which can be monitored via SmartLink software and reset via a TYPE A call point feature. The SmartWire system will ensure alarm is associated with an identification (client code) that can be used for monitoring and recording purposes on a PC (see SmartWire Installation Manual). Note: SmartWalk can be connected to other nurse call systems, however this will not be covered within the manual. Smartlink Software Connection SMARTWIRE SYSTEM INTERFACE - + C B - + C B - + R S EMERGENCY R G REED SWITCH ON DOOR Y SMARTWIRE TYPE A CALL POINT NIGHT REED GND 12V GND RESET N/O COMM B A OS ON RESPONDER 13

6. TROUBLESHOOTING Problem Explanation/Solution Wanderer NOT being picked up when in Door Responder range. (Red LED does not pulse) Firstly, ensure that the Door Stations and Base Station are all switched on and being supplied with power. When testing a system, observe the red sensing LED in the Door Responder. As soon as the wanderer is within the field of the Resonator, the LED should start flashing at a constant rate to indicate that the wrist unit is transmitting. If the LED is not flashing either the wrist transmitter or the Resonator is not functioning. To confirm the wrist transmitter operation, test with a different wrist unit and observe the result. Wrist transmitters are subjected to damage through normal use, and can be rendered inoperative by a substantial physical shock or repetitive physical treatment. If no wrist transmitters will activate the red LED then the Resonator or Door Responder may be inoperative. Bring the wrist transmitter up very close to the Resonator and check the LED. If it starts flashing, then the Resonator is operating on a very reduced range and will require replacement. If these tests do not rectify the problem please contact your distributor. Wanderer is picked up but alarms are not activating. If the Reed Switch on the exit door is faulty (i.e stuck in the closed position), then the alarm will not activate. To test a Reed Switch, turn off the power, connect a multi-meter (set to read resistance in Ohms) between the Reed Switch connection and the Responders ground terminal, then open and close the door to ensure that Reed Switch is opening and closing the circuit. If not, replace the Reed Switch. No alarms are reported at the Base Station. If the internal RF transmitter in the Responder is incorrectly set, then no alarm will be activated at the Base Station. Check the RF transmitter, in particular the settings of the access codes on the transmitter, and the Base Gateway Receiver. If they do not match, a signal will NOT be received. To easily confirm the operation of the transmitter set the RF Base Station to night operation. Occurrence of False alarms. False Alarms are usually a result of a Wrist Transmitter being left within the field of the Resonator unintentionally. Make sure all spare Wrist Transmitters are stored well away from any door stations, preferably in a metal cabinet. Also note that wrist transmitters can be triggered by other alternating magnetic fields, including those from scanning circuits in TV s, video monitors etc. Also check that a resident who wears a wrist unit does not occupy a bed adjacent to a door station. The field can penetrate through brick walls and activate nearby Wrist Transmitters in another room. False alarms can also occur when a wanderer lingers close to the field of a door station, and a door to another station nearby is opened. The nearby door station may pick up the signal of the wanderer at the other door, even though they have not opened that door. The signal from the Wrist Transmitter can penetrate up to 15 meters under ideal conditions. The best practice is to discourage wanderers from lingering near monitored doors. 14

A division of NESS CORPORATION PTY LTD Copyright SmartLink International August 2011 Unit 4/56 Norcal Rd, Nunawading VIC 3131 Australia Tel: +61 3 9875 6400 Facsimile: +61 3 9875 6422 Email: smartlink@ness.com.au Website: www.smartlink.com.au To the best of our knowledge, the information contained in this manual is correct at the time of print. SmartLink International A division of NESS CORPORATION PTY LTD reserves the right to make changes to the features and specifications at any time without prior notice in the course of product development. 15