Evolution in the knowledge about interior firefighting

Similar documents
A fire suffering from a lack of air...

The most familiar form of Rapid Fire Progress: Flashover

Max Fire Box Users Guide

New insights into ventilation

So, How do Fire Starts & Spreads? A question we need to understand and appreciate the dynamics of fire life cycle.

Essentials of Fire Fighting 6 th Edition Firefighter I

LESSON ONE FIREFIGHTER I Fire Behavior

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

At the end of this study topic, you will be able to discuss the chemistry of fire; discuss the fire dynamics in a compartment fire; and explain the

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

The phenomenon of the flashover and backdraft. Backdrafts and flashovers. Backdrafts, rollovers and flashovers

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE?

Modeling a real backdraft incident fire

Fire Gas Ignition; Brandgasexplosion; Fire gas Explosion; 3D Firefighting; Terminology & Developments 2004

INTERNATIONAL FIRE TRAINING CENTRE

Fire is No Accident Fire is No Accident It can be prevented.

CFD Model of a Specific Fire Scenario

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

Ventilation Effects on Fire Patterns during Post Flashover Burning

Review for Unit Test #3: Fire Emergencies

Anatomy of a Fire. Christopher Crivello, MSFPE, PE. Douglas Nadeau, MSFPE, PE, CFPS, LEED AP

TIMOTHY R. SZYMANSKI Instructor

Fire safety systems. Behaviour of fires

The standpipe A link between fire prevention and fire fighting

InstrumentationTools.com

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Charles M Fleischmann a, *, ZhiJian Chen b

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

Course Learning Outcomes for Unit III. Reading Assignment. Unit Lesson. UNIT III STUDY GUIDE Physical Properties of the Three States of Matter: Part 2

Upon completion of this unit of study, the student should be able to: 1. Identify the components of the fire triangle and the fire tetrahedron.

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Workplace FIRE SAFETY

LEARNING SPECIAL HAZARD DETECTION TYPES

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

12-Minutes on the Fireground. Introduction Case Study Method Case Study 1: Keokuk, Iowa Fire Modeling... 9

Fire Detection System: An Overview

WATER MIST CONVENTION AND EXHIBITION

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

Fire Safety Awareness Training START

Gothenburg dance hall, Sweden, 1998

Experimental Room Fire Studies with Perforated Suspended Ceiling

A DECADE OF SCANDINAVIAN RESEARCH AIMED AT BENEFITING THE FIRE SERVICE

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Fire Behavior CHAPTER OVERVIEW OBJECTIVES AND RESOURCES C H A P T E R 6

Hazardous Material Safety Program

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Leader s Guide 2007 CLMI Training

Full Scale Battery Tests

Fire Prevention. Risk Management Services. October 7-13, 2012 National Fire Prevention Week National Fire Protection Association

( )

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

5 Key Stages to Risk Assessment

E4218 Fire Extinguisher Basic Training. Leader s Guide

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

The Possibilities of Applying Mobile Ventilators In the Process of Indoor Fire-fighting

BULLARD T4MAX THERMAL IMAGER CAMERA

CRJ 248: Scientific Investigation. Chapter 14: Arson and Explosive Evidence

LCES: LOOKOUTS, COMMUNICATIONS, ESCAPE ROUTES, SAFETY ZONES

Analysis of Two Typical Barriers to Fire Spread. Assignment #1. Prepared by STUDENT NAME. For Professor XXXXXXXXXXX

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Building Science Basics

RELIGIOUS, FESTIVAL & OTHER DECORATIONS - FIRE SAFETY GUIDANCE

In just two minutes, a fire can become life-threatening. In five minutes, a residence can be engulfed in flames.

WSU-TFREC Fire Safety Training

IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)

1893 Chicago World s Fair

INVESTIGATION OF THE DECREASE OF SOIL ORGANIC MATTER AND SOIL POLLUTION BY HEAVY METALS IN THE AREAS INTENSIVELY USED FOR MILITARY ACTIVITIES

"FIRE PREVENTION IN HEALTHCARE FACILITIES"

Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm

Indicators of Trouble. by John J. Lentini, CFI, F-ABC

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

FIRE AND FIRE FITTING By Mr. Prashant Sansare

SOUTH AFRICAN PONY CLUB

CHIEF S FILE CABINET

Salt Lake Community College FIRE EXTINGUISHER TRAINING

EASTERN ARIZONA COLLEGE Fire Department Operations I

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

(Material correct Autumn 2013)

Fire Investigation Terms

Lesson Plan for Fire Safety Starts with You!

First Revision No. 6-NFPA [ Section No. 2.2 ]

METHODOLOGY. Definitions. A Collaboration of U.S. NRC Office of Nuclear Regulatory Research (RES) & Electric Power Research Institute (EPRI)

"USING FIRE EXTINGUISHERS"

Fire Investigation Terms

FIRE SAFETY FOR OFFICE WORKERS

Fire in an archive warehouse January 28 th 2002 Roye [Somme] France

What are the four things that must be present at the same time to produce fire?

COMBUSTIBLE DUST SAFETY PROGRAM

Transcription:

Evolution in the knowledge about interior firefighting Most of us followed the basic firefighter course years ago. For some this may even be decades ago. Since that time, say the 80 s, society has gone through a major transition. Some bought their first car back in those days. If we would look at that first car and compare it with the new cars we buy today, we would notice some major differences. The same statement goes for the way we are constructing house and buildings. Today houses are constructed with high performance double glazing or even triple glazing. Houses and buildings have thicker thermal insulation layers. We even build airtight passive houses. It is obvious that the fires we have to fight in these buildings also changed. The fire department is nowadays sometimes confronted with fires that, about 40 years ago, not even existed. Luckily our tools & gear also improved. The nozzle from today hardly resembles with the normalized nozzle from the old days. And the knowledge about fire, the fire science, has also evolved. So let s have a closer look. With these articles we want to see where we are today: old knowledge which is still relevant as well as the new approaches to firefighting. In this first article we start with two themes that always have been around: the fire triangle and the ventilated fire behavior. 1 The fire triangle 1.1 The start of a fire Everybody knows the fire triangle model. It is being used to explain the start of combustion. The three components are fuel, air (oxygen) and (activation-)energy. The word energy is often replaced by temperature or heat in this context. These three components need to be present in sufficient quantities to get the combustion going. The process of combustion is actually a chemical interaction between fuel particles and oxygen. This process produces heat (energy). To start this process there has to be an energy source available. This can be a candle, an overcharged electrical wire, Figure 1 The fire triangle (graphic: www.wikipedia.org) Once the combustion is going and the is fire started, it consumes oxygen. In the air there normally is 21% oxygen present. A fire in a closed compartment consumes so much oxygen that the oxygen levels in the compartment actually go down. At a certain point the combustion process stops because of lack of oxygen. In general it is stated that CFBT-BE 1/5 Article March 2010

combustion will stop with oxygen levels at or below of 14% to 15%. This is very easy demonstrated by lighting a candle an placing it in a glass bell. At that time the candle is actually burning in a closed compartment. The air (oxygen) present in the compartment is consumed and eventually the candle will go out by itself. 1.2 The fire quadrangle Sometimes the fire quadrangle is mentioned. In that case the ratio between air and fuel is also taken into account. Let s say we put some wood shavings in bowl. It will be very easy to ignite. The wood shavings have a big surface exposed to air. This means there is a good fuel/air ratio. If we would try to put a wooden beam on fire with the same ignition source it wouldn t work. The surface of the wooden beam exposed to air is in fact a lot smaller compared to the wood shavings. With the wooden beam we have a bad fuel/air ratio. 1.3 The role of the fire triangle in rapid fire progress In case of rapid fire progress (Flashover, Backdraft & Fire Gas Ignition) there is an important role for the fire triangle. Whenever one of these phenomena occurs you can apply the fire triangle. There always has to be a mixture of fuel, oxygen and energy in certain proportions to trigger one of the phenomena mentioned. A rather simple example of this is backdraft. Prior to backdraft there is a rich mixture with a lack of oxygen. The temperature in the compartment assures that two sides of the fire triangle are present: fuel and energy. It is only when we add oxygen, the third side, into the compartment that backdraft can occur. In other words: we need to have all three sides of the fire triangle to get a backdraft. This also goes for all the other rapid fire phenomena. 2 The ventilated fire The burning regime plays a crucial role in the fire development. The quantity of air available to the fire will determine the regime of the fire. Because of this we have two kinds of fire. The ventilated fire is historically seen the fire that we came across the most. This kind of fire typically has enough ventilation (air supply) to keep going. 2.1 Ignition and start of the fire At a certain moment in time there will be an ignition. In each compartment there normally is 21% oxygen present. So at the start of the fire there is plenty of oxygen for the fire to keep going. After some time the oxygen will be replaced by the smoke produced by the fire. The percentage of oxygen in the room will decrease. Therefore we can say that during this phase a fire is fuel controlled. This means that the quantity of fuel will determine how fast the fire can grow. In the starting phase the energy source (for example a cigarette) will interact with a flammable product. This flammable product will initially produce smoke. In other words, after the ignition we get a smoldering fire. In general more and more fuel will get involved into the fire. The surface of the fire will become bigger and the temperature will start to rise. CFBT-BE 2/5 Article March 2010

A little later the rising smoke will ignite. These flames in itself produce radiant heat. As soon as there are flames in the smoke, the combustion process will accelerate. The radiant heat coming from the flames can reach further. The temperature of objects nearby the fire will start to increase. When these objects received sufficient heat, they will first emit vapour and then pyrolysis gases. Both gasses will be light-colored (white to gray). 2.2 The growth phase As soon as the rising smoke above the starting fire is showing flames the growth phase has started. Within the compartment it is now very obvious that there is a fire going. There is plenty of smoke visible and the temperature is obviously rising. The smoke layer will start to descend. It is built up by the rising smoke of the fire and the pyrolysis gasses coming from the radiated objects in the room. During the growth phase a neutral layer or neutral zone will appear (See Figure 2). Figurally speaking, we could draw a line at the bottom of the smoke layer. In the smoke layer the amount of gaseous fuel will keep increasing, while under the smoke layer there is still a lot of oxygen present. Also the visibility under the smoke layer is still rather good. With the growing fire the smoke layer will come down. The speed of this evolution is an indicator that tells us how fast the fire is growing. A fast lowering smoke layer indicates a fast developing fire and is very dangerous. Figure 2 Establishment of the neutral zone in an attack cell. Above we find dark grey smoke. Below there is still a good visibility. (Picture: Stef Vandersmissen Zaventem Fire department) At a certain time flames within the rising smoke will hit the ceiling and they will be propagating horizontally along the ceiling. At that point there is a flame front within the smoke layer. This flame front will advance away from the seat of the fire through the smoke. This phenomenon is called a roll-over. The appearance of a rollover marks the end of the growth phase of the fire. Because of the radiant heat coming from the smoke layer the ambient temperature will now rise very quickly. Flashover will occur. During the growth phase more and more fuel becomes involved in the fire. The front of flames will grow and the volume of the fire also will become larger. The fire needs more and more oxygen. At the same time the percentage of oxygen in the compartment will start to go down. Especially in the upper zone of the compartment the air becomes CFBT-BE 3/5 Article March 2010

polluted with smoke from the combustion. The fire is still fuel controlled but is evolving towards a ventilation controlled fire. 2.3 Flashover During the growth phase all the objects in the compartment started to pyrolyse. The combustion process produced a lot of smoke. This smoke contains a certain amount of flammable gasses like CO. The hot smoke layer is essentially a reservoir of hot gaseous fuel. With the roll over this reservoir ignites. Temperatures will then rise quickly. In a few seconds the fire in one spot of a compartment evolves to a fire that engulfs the complete compartment. We then see the transition of a two dimensional fire to a three dimensional fire. This means we can define a flashover as: Flashover is a sudden and continuing transition from a developing fire to a fully developed fire. After the flashover the whole compartment is fully engulfed in fire. The amount of fuel taking part in the combustion process has become a lot bigger. Therefore the fire now needs more oxygen then before the flashover. The fire has become ventilation controlled. This happens because in a compartment a fully developed fire needs a lot more oxygen then possibly can be provided through ventilation. Ignition Growth Fully developed Decay Figure 3 The ventilated fire (Graphic: Karel Lambert) Time 2.4 The fully developed fire Once a fire is post-flashover the whole compartment is on fire. Anything within the compartment is lost. The fire resistance of the construction elements surrounding the fire (floor, ceiling, walls, ) will determine if the fire stays contained or finds its way to other compartments. If a door is left open the adjoining room will quickly evolve to flashover. CFBT-BE 4/5 Article March 2010

It possible that you have a fully developed fire (post flashover) in one room and a fire in developing phase (pre flashover) in the next room. The compartment with the fully developed fire will burn down completely. The fire is at that time ventilation controlled. It will keep on going till it runs out of fuel. 2.5 Decay of the fire While the fire is going it will consume more and more fuel. At the end of the burning phase the intensity of the fire will go down. The production of smoke will also become less. This way the quantity of inflowing air increases. The amount of fuel involved in the combustion will become less while the amount of oxygen will rise. At some time the burning regime will go back from ventilation controlled to fuel controlled. During the decay of the fire there are still objects that are hot enough to continue to pyrolyse. The intensity of the fire might be a lot less, the continuous release of pyrolysis gasses remains a risk for the firefighters. 3 References [1] Hartin Ed, www.cfbt-us.com [2] Mcdonough John, New South Wales Fire Brigade, personal communication, 2009 [3] Raffel Shan, www.cfbt-au.com, personal communication, 2009 [4] Grimwood Paul, Hartin Ed, Mcdonough John & Raffel Shan, 3D Firefighting, Training, Techniques & Tactics, 2005 [5] Grimwood Paul, www.firetactics.com, personal communication, 2008 [6] Lambert Karel & Desmet Koen, Binnenbrandbestrijding, versie 2008 & versie 2009 (in Dutch or French) [7] Bengtsson Lars-Göran, Enclosure Fires,2001 [8] Gaviot-Blanc, Franc, www.promesis.fr Karel Lambert CFBT-BE 5/5 Article March 2010