Operating instruction. Remote control station WCM-FS /

Similar documents
Operating instructions

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

BM Programming Module. For the heating engineer Installation instructions

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

new.11 The new Weishaupt products

Boiler controller S-Tronic Plus

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

Boiler controller Lambdatronic S 3200

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Condensing Boiler RS100 Controller Training Program

Operating instructions

Installation and Operating Manual. Merlin 5064 V3. System Manager

Operating Instructions

INSTRUCTION FOR THE USER THC V E OIL BLU

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Operating Instructions

Installation and servicing instructions

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

VIESMANN. Operating instructions VITOTRONIC 200. for the system user

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

Quickheat 30 weather compensated boiler control

Model: Slimline-RF. 1 Slimline Series

danfoss Heating Solutions 5

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Installation & User s Instructions

Vokèra OpenTherm 711 without external sensor connected

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Operating instructions

VR 90 Remote control unit

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Operating Instructions

Model: Touch-RF. 1 Wireless Series

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

Installation and Operating Manual. Merlin IO 5064 V4 with BM-T. System Manager

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

CS027 User Instructions

Vokèra OpenTherm 711 with external sensor connected

Heating Controller SDC Remote Heating Controller DHC

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

REA22 Room Temperature Controller

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

ECL Comfort 210 / 296 / 310

E8 Controller and BCM for Modulex EXT GF-136-C USER MANUAL. Installation, Operation & Maintenance

Modulating clock thermostat

Supplement to operating and installation manual no for the VR 81 remote control unit

Heating Controller SDC Remote Heating Controller DHC

For heating engineer/user. Operating and Installation Manual VRC 630/2. Weather compensated cascade control VRC 630

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Heating Controller SDC Remote Heating Controller DHC

WLM2 WLTA WLTD WLTP WLCT2

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

Operating Instructions. Luxtronik. Heating- and Heat Pump Control

Installation instructions. Advanced Weather Compensation Controller. Sense II O UK/IE (2015/10)

Daikin Altherma Hybrid User Guide

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

USERS GUIDE 24, 30. For installation guide see reverse of book

Control System THETA. Operating Instructions. Room control unit RSC and RSC-OT

Albatros 2 Solar compact controller User manual RVA Building Technologies

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

Service Instructions for use by heating contractor

Heating and D.h.w. Controller RVL482 Basic Documentation

Room Unit for Boiler Control QAA User manual. Building Technologies. With OpenTherm Interface

Model: Touch-RS. 1 Touch-RS

Digital Thermostat Models: VS30W and VS30B

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

User Instructions For TopTronic RS-30

Control Application. Supplement - ACVMax

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

On initial power up the thermostat will guide you through set up procedure for the following:

Transcription:

83277702 1/22-04

1 User instructions... 4 1.1 User instructions... 4 1.2 User guide... 4 1.2.1 Symbols... 4 1.2.2 Target group... 4 1.3 Guarantee and Liability... 4 2 Safety... 5 2.1 Permissible application... 5 2.2 Safety measures... 5 2.3 Disposal... 5 3 Product description... 6 3.1 Type key... 6... 7 4.1 Operating panel... 7 4.2 Display... 8 4.2.1 display... 8 4.2.2 Setting level standard display... 9 4.2.3 Lockout display... 9 4.2.4 Service display... 9 4.3 Settings in the standard display... 10 4.3.1 Set DHW setpoint... 10 4.3.2 Display general information... 11 4.3.3 Set room temperature... 14 4.3.4 Select type of operation... 15 4.4 Presence and absence function... 16 4.4.1 Activating a heating program... 16 4.4.2 Cancelling a heating program... 16 4.4.3 Setting the effectiveness duration... 17 4.5 Activating end user level... 19 4.6 Menu structure end user level... 21 83277702 1/22-04 La 2-43

4.7 Settings of end user level... 23 4.7.1 Call up info external min... 23 4.7.2 Call up info external max... 23 4.7.3 Call up info solar yield counter... 24 4.7.4 Call up info total solar yield... 25 4.7.5 Call up info solar statistic... 26 4.7.6 Setting room sensor correction... 27 4.7.7 Set contrast... 27 4.7.8 Set brightness... 28 4.7.9 Set normal room temperature... 28 4.7.10 Set setback room temperature... 29 4.7.11 Set normal supply temperature setpoint... 29 4.7.12 Set setback supply temperature setpoint... 30 4.7.13 Set acceptance room... 31 4.7.14 Set gradient... 31 4.7.15 Set room frost protection temperature... 33 4.7.16 Set Summer/Winter change-over... 33 4.7.17 Set normal DHW temperature... 34 4.7.18 Set setback DHW temperature... 34 4.7.19 Set acceptance DHW... 35 4.7.20 Set holiday duration... 35 4.7.21 Set temperature level... 36 4.7.22 ing holiday function ahead of schedule... 36 4.7.23 Set date, time and summer time change-over... 37 4.7.24 Call up time program... 38 4.7.25 Changing a time program... 39 4.7.26 Set pre-setting HC#2... 40 4.7.27 Set WCM-EM without WCM-FS assigned... 41 5 Key word index... 43 83277702 1/22-04 La 3-43

1 User instructions 1 User instructions Translation of original operating instructions 1.1 User instructions These operating instructions form part of the equipment and must be kept on site. 1.2 User guide 1.2.1 Symbols DANGER Immediate danger with high risk. Non observance can lead to serious injury or death. WARNING CAUTION Danger with medium risk. Non observance can lead to environmental damage, serious injury or death. Danger with low risk. Non observance can cause damage to the equipment and injury to personnel. Important information. Requires direct action Result after an action Itemisation. Range. 1.2.2 Target group These operating instructions are intended for the operator. They should be observed by all personnel working with the device. 1.3 Guarantee and Liability Guarantee and liability claims for personal and equipment damage are excluded, if they can be attributed to one or more of the following causes: Non approved application of the remote control station, non observance of the operating instructions, continual operation despite a fault, repairs, which have been carried out incorrectly, the use of non original Weishaupt parts, acts of God. 83277702 1/22-04 La 4-43

2 Safety 2 Safety 2.1 Permissible application The remote control station WCM-FS 2.0 is suitable for the control of a heating system consisting of a Weishaupt condensing boiler combined with a solar system and solar controller WCM-SOL 1.0 home. Any use other than that described above shall be deemed improper. Weishaupt cannot be held responsible for any damage resulting from such use. The risk of such misuse lies entirely with the user. Correct use also includes compliance with the installation and operating manual and all other documents, which are included in the delivery in addition to these instructions. The device described in these instructions conforms to the recognised level of technology and safety relevant regulations. Improper or inappropriate use could endanger the health and safety of the user or third party and impair the device function. 2.2 Safety measures Safety relevant fault conditions must be eliminated immediately. 2.3 Disposal Dispose of all materials used in a safe and environmentally friendly way. Observe local regulations. 83277702 1/22-04 La 5-43

3 Product description 3 Product description The remote control station WCM-FS 2.0 is a control and operating device for WCM components, such as a Weishaupt condensing boiler in combination with a solar controller WCM-SOL 1.0 home. 3.1 Type key WCM Series: Weishaupt Condens Manager -FS Type: Remote control station 83277702 1/22-04 La 6-43

4.1 Operating panel modul control 1 Dial knob Navigation through levels and parameters, change values, switch on illumination. 2 Function keys 1 4 Used to activate functions. 3 Presence and absence key Used for short term interruption or extension of the heating program. Used to set duration of effectiveness. 4 Menu key Used to activate or exit user level. 83277702 1/22-04 La 7-43

4.2 Display Depending on the type of system, different features may be shown in the display. 4.2.1 display Factory presetting Display of allocated factory pre-settings (standard). 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. 20.0 C Heating program 1 1 ebus address, weekday, date, time 2 Symbol DHW heating 3 Information time program bar (HC = heating circuit, DHW = DHW load circuit) 4 current room temperature possibly current flow temperature (no display of room temperature, if the remote control station WCM-FS is installed in the boiler) 5 Type of operation with symbol Symbols for type of operation Normal operation Night setback operation Summer (DHW operation only) Standby 83277702 1/22-04 La 8-43

4.2.2 Setting level standard display Normal room temp Set 22.0 C Act 22.0 C 15.0 C - 30.0 C 1 Display function key 1 Abort setting procedure without saving and exit level 2 Display function key 2, if applicable special functions e.g. Holiday, DHW Boost 3 Display function key 3 Display factory pre-settings 4 Display function key 4 save altered values and exit level 5 Setting level 6 Room temperature setpoint 7 Current room temperature 8 Value range 4.2.3 Lockout display The display can be triggered by any WCM device in the system. Note down display and inform the customer service department. 1 Mo 21.May 07 19:20 WTC sensor Lockout Heating program 1 i 1 Error location and error type 2 Error code specifying the fault 4.2.4 Service display This display is initiated by the condensing boiler. Inform customer service department. 1 Mo 21.May 07 19:20 WTC#1 Service Heating program 1 i 83277702 1/22-04 La 9-43

4.3 Settings in the standard display 4.3.1 Set DHW setpoint The water tap symbol is only available on systems with DHW operation. In the standard display, the Normal DHW-Set can only be changed in normal DHW operation and the Setback DHW-Set can only be changed in DHW setback operation. Press function key 1 (water tap). Level Normal DHW setpoint or if applicable, Setback DHW setpoint is displayed. Set value using the dial knob and save with function key. 1 Mo 21.May 07 19:20 1 Mo 21.May 07 23:20 HC 12 24 i Room temp. 20.0 C Heating program 1 HC 12 24 i Room temp. 20.0 C Heating program 1 Normal DHW setpoint Set 50.0 C Set DHW boost Act 45.0 C Act Setback DHW setpoint 40.0 C DHW boost 45.0 C 40.0 C - 60.0 C 8.0 C - 40.0 C Manuel DHW boost function The DHW boost function is used to cover increased demand for hot water during setback operation. The hot water temperature heats up once to the normal DHW setpoint. At the same time the circulation pump is activated. Press function key 1 (water tap). Setback DHW setpoint is displayed Activate DHW boost function with function key DHW boost. Display changes temporarily from Setback 1 to Normal 2 Setback DHW setpoint Set 40.0 C DHW Boost Act 45.0 C 8.0 C - 40.0 C Normal DHW setpoint Set 50.0 C DHW Boost Act 45.0 C 40.0 C - 60.0 C 83277702 1/22-04 La 10-43

4.3.2 Display general information In the standard display, the time bar 1 shows the heating program currently active (HC = heating circuit or DHW = DHW load circuit). By repeatedly pressing function key 2 i, the current actual values of the heating system are displayed one by one. The information selected last remains permanently displayed and is only interrupted by a lockout or servicing. 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. 20.0 C Heating program 1 Lockout i Lockout Servicing i Servicing HC 12 24 i Time bar current heating program (with control centre DHW) External C i External temperature DHW C i DHW temperature Boiler C i Boiler temperature Supply temperature C i Supply temperature heating circuit Calorifier C i Calorifier temperature Calorifier top C i Calorifier temperature bottom De-couple C i De-couple temperature The scope of information depends on the scope of the system. If the system includes a WCM-SOL solar controller or a WCM-KA cascade manager, the boiler temperature is not displayed. 83277702 1/22-04 La 11-43

Status information of the heating circuit: Status#...... i Additional functions activated Screed Service SOL-Excess temp SOL-Excess Frost Syst-Standby Frost limit Summer Heating limit Thermostat Adaption On Opti DHW active Acceptance Heat Normal Setback Standby Summer Screed function Chimney sweep function is carried out on the heat exchanger. Heat consumption due to excess solar temperature. Heat consumption due to solar coverage. Frost protection is activated System in Standby mode External temperature has fallen below the frost limit. System operates continuously at normal temperature. Average external temperature has exceeded the summer switch over temperature. Heating is off. Average external temperature exceeds the room temperature setpoint. Heating is off. The room thermostat function has switched off the heating. Automatic adaption activated System heats up due to the switch on optimisation. DHW loading is carried out. Level reduction due to high solar yield. Current temperature level. The current type of operation is not overridden by any of the functions listed above. Current temperature level. Current temperature level. Current temperature level. Status information of the DHW load circuit: Status DHW... i Additional functions activated DHW active SOL-Excess temp SOL-Excess Acceptance DHW Normal Setback Standby Summer DHW loading is carried out. Heat consumption due to excess solar temperature. Heat consumption due to solar coverage. Level reduction due to high solar yield. Current temperature level. The current type of operation is not overridden by any of the functions listed above. Current temperature level. Current temperature level. Current temperature level. 83277702 1/22-04 La 12-43

The following display appears only when using the solar controller WCM-SOL 1.0 home. Collector C i Temperature of the collector Solar bottom C i Temperature when lowering Yield kwh Today's solar yield Status information of the solar circuit: Status SOL: Stagnation Overheat protection for collector, hydraulic and temperature reduction. Status SOL: K-Frost Collector frost protection activated. Status SOL: Manual Solar controller in manual function. Status SOL: Emergency Solar controller in emergency operation. Status SOL: Off No energy yield from solar system. Status SOL 0,5 kw Energy yield from solar system (in kw). Status SOL: Cool Status SOL: Special Solar recooling. Solar energy yield: DTR special phase T1-T2 Due to the update of the information there may be a delay in the reaction of the display. 83277702 1/22-04 La 13-43

4.3.3 Set room temperature The display differs according to the type of operation and setting selected by the heating engineer. Type of operation Symbol Display Normal Normal room temp Normal supply setpoint Heating program 1 3 in heating operation Heating program 1 3 in setback operation Setback Standby Normal room temp Normal supply setpoint Setback room temp Setback supply setpoint Setback room temp Setback supply setpoint Room frost temp Summer Room frost temp Press function key 3. Depending on the controller configuration either Room temp or Supply setpoint is displayed. Set required value using the dial knob. Save with function key 4. 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. 20.0 C Heating program 1 Normal room temp Set 21.5 C Act 20.0 C 16.0 C - 35.0 C 83277702 1/22-04 La 14-43

4.3.4 Select type of operation Menus and parameters are shown or hidden depending on the system variation. Type of operation Standby Heating program 1 3 Summer Normal Setback No heating or DHW operation. Frost protection is activated. Heating program 1 3 can be set individually (see Ch. 4.7.25). No heating operation, DHW operation only. Frost protection is activated. Heating operation is on continuously. DHW operation is carried out according to the DHW time program.. Heating operation is continuously in setback mode and/ or frost protection mode, this depends on the settings made by the heating engineer. DHW operation is carried out according to the DHW time program. The following functions are available in heating programs 1 3: Presence and absence function, automatic Summer-/Winter change-over and room thermostat function. Set Holiday (see Ch. 4.7.20). Press function key 4. Menu Type of operation is displayed. Make selection using the dial knob and save with function key. The type of operation saved is displayed 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. 20.0 C Heating program 1 Type of operation Holiday Heating program 2 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. 20.0 C Heating program 2 83277702 1/22-04 La 15-43

4.4 Presence and absence function Using the presence and absence function, the heating program can be extended or interrupted for a short period of time. This function is only possible in type of operation heating program 1... 3. The presence and absence function remains activated until: the next automatic switch-over of the heating program, until the heating program is reactivated by pressing the key. Presence and absence function does not operate with: a control centre, a WCM-FS, which has been assigned to a WCM-EM in DHW function. 4.4.1 Activating a heating program Switch from setback temperature to normal temperature for a short period of time. Press presence and absence key The time bar increases in length, type of operation Heating program 1 changes over to Absence, the Moon symbol changes to Sun. 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. 20.0 C Heating program 1 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. Absence 20.0 C 4.4.2 Cancelling a heating program Switch from normal temperature to setback temperature for a short period of time. Press presence and absence key The time bar decreases in length, type of operation Heating program 1 changes over to Absence, the Sun symbol changes to Moon. 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. 20.0 C Heating program 1 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. Absence 20.0 C 83277702 1/22-04 La 16-43

4.4.3 Setting the effectiveness duration Settings: from current time, to next heating cycle change-over. From setback level to heating phase Press and hold presence and absence key for approx. 1.5 seconds. The entry level is displayed. Set the time using the dial knob. Move the Cursor using function key <==. Save entry using function key. The timer bar increases in length according to the time set, Presence and symbol Sun are displayed. 1 Mo 21.May 07 14:15 HC 12 24 i Room temp. 20.0 C Heating program 1 Normal from 14:15 to 06:00 <== Normal from 15:15 to 20:30 <== 1 Mo 21.May 07 14:15 HC 12 24 i Room temp. Presence 20.0 C Cancelling the function Press presence and absence key Function is cancelled. Heating program 1 and the Moon symbol are displayed. 83277702 1/22-04 La 17-43

From heating phase to setback level Save entry using function key. The timer bar decreases in length according to the time set. Absence and symbol Moon are displayed. 1 Mo 21.May 07 15:20 HC 12 24 i Room temp. 20.0 C Heating program 1 Setback from 15:15 to 22:00 e <== Setback from 15:15 to 20:30 e <== 1 Mo 21.May 07 15:20 HC 12 24 i Room temp. Absence 20.0 C Cancelling the function Press presence and absence key Function is cancelled. Heating program 1 and the Sun symbol are displayed. 83277702 1/22-04 La 18-43

4.5 Activating end user level Activate end user level Briefly press menu key user level is displayed. user Info Remote control Setting #1 in the standard display. 1 Page number menu 2 user level 3 Function key for menu selection Display further pages Turn the dial knob. Further pages of the menu are displayed. user 02 Setting #2 DHW Holiday user 03 Time-Date Time program Access HC without FS Selecting a menu Select menu and press the relevant function key. Menu is displayed. user 02 Setting #2 DHW Holiday DHW Normal DHW setpoint 50.0 C Setback DHW setpoint 40.0 C 83277702 1/22-04 La 19-43

Selecting and setting parameters Select parameter and press the relevant function key. Parameter is displayed. Make a selection using the dial knob and save setting with function key. DHW Normal DHW set 50.0 C Setback DHW set 40.0 C Normal DHW set 132 50.0 C 40.0 C - 60.0 C Resetting parameters to factory presetting Press function key. Factory presetting is displayed. Press function key. Factory presetting is saved. Normal DHW setpoint 132 50.0 C 40.0 C - 60.0 C Exit end user level Press function key repeatedly or briefly press menu key. display appears. 83277702 1/22-04 La 20-43

4.6 Menu structure end user level Menu points and parameters are hidden or displayed according to the settings made in the heating engineer level. Menu point Parameters Description Factory presetting Level info 0 External max 002 External min 003 Yield counter kwh, Wh MWh, kwh 004 Total yield kwh, Wh MWh, kwh 005 Statistic kwh, Wh Remote control 1 Room sensor corr 0.0K (see Ch. 4.7.6) 102 Contrast (see Ch. 4.7.7) 04 103 Brightness (see Ch. 4.7.8) 30 Settings#1 112 Normal room temp 21.5 C (see Ch. 4.7.9) 113 Setback room temp 16.0 C (see Ch. 4.7.10) 114 Acceptance room Off (see Ch. 4.7.13) 115 Normal supply setpoint 75.0 C (see Ch. 4.7.11) 116 Setback supply setpoint 45.0 C (see Ch. 4.7.12) 117 Gradient (see Ch. 4.7.14) 118 Room frost temp 10.0 C (see Ch. 4.7.15) 119 Su/Wi change-over 20.0 C (see Ch. 4.7.16) Settings#2 121 Normal supply setpoint 75.0 C (see Ch. 4.7.11) 122 Setback supply setpoint 45.0 C (see Ch. 4.7.12) 123 Gradient (see Ch. 4.7.14) 125 Su/Wi change-over 20.0 C (see Ch. 4.7.16) DHW 132 Normal DHW setpoint 50.0 C (see Ch. 4.7.17) 133 Setback DHW setpoint 40.0 C (see Ch. 4.7.18) 134 Acceptance DHW Off (see Ch. 4.7.19) Holiday 141 Duration (see Ch. 4.7.20) 142 Temp. level (see Ch. 4.7.20) Frost Set 83277702 1/22-04 La 21-43

Menu point Parameters Description Factory presetting Time-Date 151 Date (see Ch. 4.7.23) 152 Time (see Ch. 4.7.23) 153 Summertime start 25.Mar (see Ch. 4.7.23) 154 Summertime end (see Ch. 4.7.23) 25.Oct Time program Heating program 1 (see Ch. 4.7.24) Heating program 2 Heating program 3 161 Advance #2 (see Ch. 4.7.26) Off DHW program (see Ch. 4.7.24) Circ. program (see Ch. 4.7.24) Access HC without FS new config List of all WCM-EM s without WCM-FS assigned (see Ch. 4.7.27) EM-HC#2 or EM-DHW#2 EM-HC#8 or EM-DHW#8 Set 83277702 1/22-04 La 22-43

4.7 Settings of end user level 4.7.1 Call up info external min Press function key Info. Menu Info is displayed. Press function key External Min. Parameter External Min is displayed. Info External Min External max Yield counter External Min 0 3.0 C 4.7.2 Call up info external max Press function key Info. Menu Info is displayed. Press function key External max. Parameter External max is displayed. Info External Min External max Yield counter External max 002 6.0 C 83277702 1/22-04 La 23-43

4.7.3 Call up info solar yield counter Press function key Info. Menu Info is displayed. Press function key Yield counter. Parameter Yield counter is displayed. Info External Min External Max Yield counter Yield counter 003 since 04.Aug 11 W th 45.0kWh Operation 124.0h Reset 83277702 1/22-04 La 24-43

4.7.4 Call up info total solar yield Press function key Info. Menu Info is displayed. Use dial knob to move to the second menu level. Press function key Info Solar. Menu Info Solar is displayed. Press function key Total yield. Parameter Total yield is displayed. Info External Min External max Yield counter Info Total yield Statistic Total yield 004 W th 134.4 MWh Operation 481.0 h 83277702 1/22-04 La 25-43

4.7.5 Call up info solar statistic Display of solar yields and ope5rating times of the last 14 days. Press function key Info. Menu Info is displayed. Use dial knob to move to the second menu level. Press function key Statistic. Parameter Statistic is displayed. Info External Min External max Yield counter Yield counter Total yield Statistic Statistikc 005 02: 25.Aug 11 W th 200.0kWh Operation 3.0h Reset 83277702 1/22-04 La 26-43

4.7.6 Setting room sensor correction The room sensor can be adapted to an existing thermometer. Press function key Remote control. Menu Remote control is displayed. Press function key Room sensor corr. Parameter Room sensor corr is displayed. Set value using the dial knob and save with function key. Room sensor corr Room sensor corr 0.0K Contrast 04 Illumination 30 Room sensor corr 1 0.0K -5.0K - 5.0K 4.7.7 Set contrast Press function key Remote control. Menu Remote control is displayed. Press function key Contrast. Parameter Contrast is displayed. Set value using the dial knob and save with function key. Room sensor corr Room sensor corr 0.0K Contrast 04 Illumination 30 Contrast 102 04 00-06 83277702 1/22-04 La 27-43

4.7.8 Set brightness Press function key Remote control. Menu Remote control is displayed. Press function key Illumination. Parameter Illumination is displayed. Set value using the dial knob and save with function key. Remote control Room sensor corr 0.0K Contrast 04 Illumination 30 Illumination 103 30 00-30 4.7.9 Set normal room temperature Press function key Setting #1. Menu Settings #1 is displayed. Press function key Normal room temp. Parameter Normal room temp is displayed. Set value using the dial knob and save with function key. Settings #1 Normal room temp. 21.5 C Setback room temp. 16.0 C Gradient 12.5 Normal room temp. 112 21.5 C 16.0 C - 35.0 C 83277702 1/22-04 La 28-43

4.7.10 Set setback room temperature Press function key Setting #1. Menu Settings #1 is displayed. Press function key Setback room temp. Parameter Setback room temp is displayed. Set value using the dial knob and save with function key. Settings #1 Normal room temp. 21.5 C Setback room temp. 16.0 C Gradient 12.5 Setback room temp. 113 16.0 C 10.0 C - 21.5 C 4.7.11 Set normal supply temperature setpoint Press function key Setting #1. Menu Settings #1 is displayed. Press function key Normal supply set. Parameter Normal supply setpoint is displayed. Set value using the dial knob and save with function key. Settings #1 Normal supply set. 75.0 C Setback supply set. 45.0 C Gradient 12.5 Normal supply setpoint 115 75.0 C 45.0 C - 75.0 C 83277702 1/22-04 La 29-43

4.7.12 Set setback supply temperature setpoint Press function key Setting #1. Menu Settings #1 is displayed. Press function key Setback supply set. Parameter setback supply setpoint is displayed. Set value using the dial knob and save with function key. Settings #1 Normal supply set. 75.0 C Setback supply set. 45.0 C Gradient 12.5 Setback supply set. 116 45.0 C 8.0 C - 75.0 C 83277702 1/22-04 La 30-43

4.7.13 Set acceptance room If the current solar yield is sufficient, this parameter can be set to save fossil fuel. From a particular yield level, which is set in the WCM-Sol, reheating (heat demand) by the WTC is blocked, until the current room temperature falls below the room temperature setpoint minus the "Acceptance room" set here. The mixer tries to continue the control to the room temperature setpoint set. For this function, the room sensor of the WCM-FS 2.0 is evaluated, this assumes that the FS is installed at a suitable location. Press function key Setting #1. Menu Settings #1 is displayed. Press function key Acceptance room. Parameter Acceptance room is displayed. Set value using the dial knob and save with function key. Settings #1 Normal room temp. 21.5 C Setback room temp. 16.0 C Acceptance room Off Acceptance room 116 Off --; 0.1K - 10K 4.7.14 Set gradient The heat reference line can be matched to the building by adjusting the gradient. Setting ranges depending on the type of heating circuit Type of heating circuit (P313/P314) Range Factory presetting UFH heat-up (underfloor heat-up) 2.5-6.0 2.5 UFH- heating (underfloor heating) 4.0-10.0 5.0 Radiator 60 8.0-20.0 10.0 Radiator 70 11.0-25.0 12.5 Convector 11.0-40.0 12.5 Universal (Factory presetting) 2.5-40.0 10.0 The heat circuit is set by the heating engineer in the heating engineer level. 83277702 1/22-04 La 31-43

A change in the normal room temperature or setback room temperature leads to a parallel translation of the set rate of rise. In cold weather, the room temperature is too cold. Increase gradient. In cold weather, the room temperature is too warm Decrease gradient In mild weather, the room temperature is too cold Increase normal and setback room temperature. In mild weather, the room temperature is too warm Decrease normal and setback room temperature. 90 40 35 30 27,5 25 22,5 20 17,5 15 80 12,5 70 10 60 50 40 30 9,5 9 8 7 6 5 4 3 2,5 20 20 15 10 5 0-5 -10-15 -20-25 -30-35 1 External temperature 2 Supply temperature 3 Gradient (at normal room temperature of 20 C) Press function key Setting #1. Menu Settings #1 is displayed. Press function key Gradient. Parameter Gradient is displayed. Set value using the dial knob and save with function key. Settings #1 Normal room temp. 21.5 C Setback room temp. 16.0 C Gradient 10.0 Gradient 117 10.0 2.5-40.0 83277702 1/22-04 La 32-43

4.7.15 Set room frost protection temperature The parameter room frost temperature has a direct effect on the supply temperature. The temperature set is not the actual room temperature during frost protection. The difference is negligible if the gradient has been set correctly. If the actual room temperature drops below the critical value during frost protection, increase the room frost protection temperature. If the room frost temperature is set too high, unnecessary energy will be consumed during frost protection. Press function key Setting #1. Menu Settings #1 is displayed. Use dial knob to move to the second menu level. Press function key Room frost temp. Parameter Room frost temp is displayed. Set value using the dial knob and save with function key. Settings #1 02 Room frost temp 10.0 C Su/Wi change-over 20.0 Room frost temp 118 10.0 C 4.0 C - 16.0 C 4.7.16 Set Summer/Winter change-over If the temperature set is exceeded by the average external temperature, only DHW operation is activated. The heating circuit is switched off. Press function key Setting #1. Menu Settings #1 is displayed. Press function key S/W change-over. Parameter Su/Wi change is displayed. Set value using the dial knob and save with function key. Settings #1 02 Room frost temp 10.0 C Su/Wi change-over 20.0 Su/Wi change-over 119 20.0 C --; 8.0 C - 30.0 C 83277702 1/22-04 La 33-43

4.7.17 Set normal DHW temperature Press function key DHW. Menu DHW is displayed. Press function key Normal DHW set. Parameter Normal DHW set is displayed. Set value using the dial knob and save with function key. DHW Normal DHW set 50.0 C Setback DHW set 40.0 C Normal DHW set 132 50.0 C 40.0 C - 60.0 C 4.7.18 Set setback DHW temperature Press function key DHW. Menu DHW is displayed. Press function key Setback DHW set. Parameter Setback DHW set is displayed. Set value using the dial knob and save with function key. DHW Normal DHW set 50.0 C Setback DHW set 40.0 C Setback DHW set 133 40.0 C 8.0 C - 50.0 C 83277702 1/22-04 La 34-43

4.7.19 Set acceptance DHW If the current solar yield is sufficient, this parameter can be set to save fossil fuel. From a particular yield level which is set in the WCM-Sol, DHW reheating by the WTC is blocked, until the DHW temperature falls below the DHW temperature setpoint minus the "Acceptance DHW" set here. Press function key DHW. Menu DHW is displayed. Press function key Acceptance DHW. Parameter Acceptance DHW is displayed. Set value using the dial knob and save with function key. DHW Normal DHW setpoint 50.0 C Setback DHW setpoint 40.0 C Acceptance DHW Acceptance DHW 134 2.0K --; 1.0K - 20K 4.7.20 Set holiday duration Press function key Holiday. Menu Holiday is displayed. Press function key Duration. Parameter Duration is displayed. Move the Cursor using function key <==. Set the duration using the dial knob. Save with function key. Holiday Duration Temp. level Frost Duration 141 from 24. Nov 06 <== to 29. Nov 06 83277702 1/22-04 La 35-43

4.7.21 Set temperature level Press function key Holiday. Menu Holiday is displayed. Press function key Temp level. Parameter Temp level is displayed. Set temperature level using dial knob. Frost changes to Setback Save with function key. Setting range temperature level Frost Setback The heating system is switched on if the selected frost protection temperature is not achieved and heats up to setback temperature. Heating system operates at setback temperature. Holiday Duration Temp level Frost Temp level 142 Frost 4.7.22 ing holiday function ahead of schedule The activated holiday function is displayed in the standard display. Press function key. Holiday function is ended ahead of schedule. 1 Mo 21.May 07 19:20 HC 12 24 i Room temp. Holiday 20.0 C 83277702 1/22-04 La 36-43

4.7.23 Set date, time and summer time change-over The parameter is only displayed in the remote control station, which is addressed with Control centre #L, WTC-HC#1, EM-HC#2 or WTC-HC#1 +EM-HC#2. This transfers time and date automatically to other control components. Time, Summer time start and Summer time end are set in the same way. Summer time is always changed the following Saturday to Sunday. Press function key Time-Date. Menu Time-Date is displayed. Press function key Date. Parameter Date is displayed. Move the Cursor using function key <==. Set date using the dial knob and save with function key. Time-Date Date 16.May 07 Time 19:20 Summertime start 25.Mar Date 151 16. May 07 <== 83277702 1/22-04 La 37-43

4.7.24 Call up time program Press function key Time program. Menu Time program is displayed. Press function key Heat program1. Menu Heat program 1 is displayed. Turn the dial knob. Weekdays as well as periods from Monday to Friday, Saturday to Sunday and Monday to Sunday are displayed. This procedure can also be used to call up Heat program2, Heat program3, DHW program and circulation program. Time program Heating program 1 Heating program 2 Heating program 3 Heating program 1 Monday 0 12 24 Tuesday Wednesday Sunday Mon - Fri Sat - Sun Mon - Sat 83277702 1/22-04 La 38-43

Example 4.7.25 Changing a time program Change heat program 1 Wednesday: Heat phase 1: 5:30 7:00 hrs Heat phase 2: 16:00 20:15 hrs Activate level Heat program1 (see Ch. 4.7.24). Turn dial knob until Wednesday appears. Press function key. Turn dial knob until 05:30 appears. Move the Cursor using function key <==. Turn the dial knob until 07:00 appears. Move the Cursor using function key <==. Turn the dial knob until 16:00 appears. Move the Cursor using function key <==. Turn the dial knob until 20:15 appears. Save with function key. The display now shows the saved program as a bar diagram. This procedure can also be used to change Heat program2, Heat program3, DHW program and circulation program. Heating program 1 Wednesday 0 12 24 Wednesday 06:00-22:00 --:-- - --:-- --:-- - --:-- ==> Wednesday 05:30-07:00 16:00-20:15 --:-- - --:-- ==> Heating program 1 Wednesday 0 12 24 83277702 1/22-04 La 39-43

Factory presetting time program Heating program 1 Mon - Fri 06:00-22:00 Sat - Sun 07:00-23:00 Heating program 2 06:00-08:00 Mon - Fri 16:00-22:00 Sat - Sun 07:00-23:00 Heating program 3 06:00-08:00 Mon - Fri 12:00-22:00 Sat - Sun 07:00-23:00 DHW program Mon - Fri 05:00-21:00 Sat - Sun 06:00-22:00 Circ. program 06:00-07:00 Mon - Fri 11:00-13:00 17:00-19:00 Sat - Sun 07:00-08:00 11:00-13:00 17:00-19:00 4.7.26 Set pre-setting HC#2 With address setting WTC-HC#1+EM-HC#2 an on and off switch time for the extension module EM#2 can be pre-set via parameter Pre-set #2 independent of HC#1. Setting range Off 05 min 270 min Activate level time program (see Ch. 4.7.24). Turn dial knob until Advance #2 is displayed. Press function key Pre-set #2. Set value using the dial knob. Save with function key. Display shows new value. Press function key repeatedly or briefly press menu key. Time program 02 Advance #2 DHW program Circulation program Off Advance #2 161 Off --; 05min - 270min 83277702 1/22-04 La 40-43

4.7.27 Set WCM-EM without WCM-FS assigned It is possible to operate several extension modules via one remote control station. In menu point Access HC w.o. FS all extension modules without WCM-FS assigned are listed, and can be set via this menu point. Press function key Access HC w/o. FS. Level Access HC w.o. FS is displayed. Access HC without FS new config EM-HC#2 EM-DHW#3 1 New configuration 2 Display extension module heating circuit without remote control station assigned 3 Display extension module DHW without remote control station assigned By pressing function key new config all the WCM-EM connected without WCM- FS assigned are determined/identified and displayed. Set extension module without WCM-FS assigned Press function key EM-HC#2. user#2 is displayed highlighted black. Carry out setting. Parameters, which are not activated are displayed with ---- and cannot be set. Access HC without FS new config EM-HC#2 EM-DHW#3 user#2 Settings Holiday Time program Settings#2 Type of operation Normal room temp ---- Setback room temp ---- Type of operation#2 111 Heating program 1 83277702 1/22-04 La 41-43

Find extension modules without WCM-FS assigned If no or not all extension modules are displayed a new configuration must be carried out. Press function key new config. Message search config is displayed briefly, then the list of extension modules without remote control station assigned reappears. Access HC without FS new config EM-HC#2 EM-DHW#3 Menu structure extension module heating circuit (Access HC w.o. FS) Menu point Parameters Description Factory presetting Settings# 111 Type of operation Heating program 1 112 Normal room temp 21.5 C 113 Setback room temp 16.0 C 115 Normal supply setpoint 75.0 C 116 Setback supply setpoint 45.0 C 117 Gradient 118 Room frost temp 10.0 C 119 Su/Wi change 20.0 C Holiday 141 Duration 142 Temp level Frost Time program Heating program 1 Heating program 2 Heating program 3 Set Menu structure extension module DHW (Access HC w. o. FS) Menu point Parameters Description Factory presetting DHW 131 Type of operation DHW program 132 Normal DHW setpoint 50.0 C 133 Setback DHW setpoint 40.0 C 134 Acceptance DHW Holiday 141 Duration 142 Temp level Frost Time program DHW program Circ. program Set 83277702 1/22-04 La 42-43

5 Key word index C Contrast...27 D Date...37 DHW... 34, 35 DHW boost function...10 DHW setpoint...10 Display...8, 9, 27, 28 Disposal... 5 E holiday...36 user level...19 Extension module...41 External temperature...23 F Factory presetting...8, 21, 42 Factory presetting time program...40 Frost protection...33 Frost protection temperature...36 Function key... 7 G Gradient... 31, 32 Gradient factory presetting...31 Guarantee... 4 H Heat reference line...31 Holiday... 35, 36 I Illumination...7, 28 Information...11 L Liability... 4 Lockout... 9 M Menu key... 7 Menu structure... 21, 42 Moon... 8 Presence and absence key... 7 Pre-setting HC#2...40 R Room frost temperature...33 Room sensor correction...27 Room temperature...14, 28, 29, 32 S Safety measures... 5 Service... 9 Set factory presetting...20 Setback room temperature...29 Solar statistic...26 Solar yield...25 Solar yield counter...24 display... 8, 9, 10 Standby... 8 Summer time...37 Summer/Winter change-over...33 Sun... 8 Supply setpoint temperature... 29, 30 Symbol...14 Symbol type of operation... 8 T Temperature level...36 Time...37 Time program... 38, 39 Time program bar... 8 Type key... 6 Type of heating circuit...31 Type of operation...8, 14, 15 U Umbrella... 8 V Value range... 9 W Water tap... 8 N Night setback operation... 8 Normal operation... 8 O Operating panel... 7 P Presence and absence function...16 83277702 1/22-04 La 43-43

www.weishaupt.de Max Weishaupt GmbH, D-88475 Schwendi Weishaupt (UK) Limited Neachells Lane, Willenhall, WV13 3RG www.weishaupt.co.uk Printed in Germany. All rights reserved. Product Description Performance W-Burners Monarch and industrial burners The compact series, proven millions of times over: Economical, reliable, fully automatic. Gas, oil and dual fuel burners for domestic and commercial applications. The purflam burner gives almost soot-free combustion of oil with greatly reduced NO x emissions. The legendary industrial burner: Tried and tested, long lived, clear construction. Gas, oil and dual fuel burners for district heat provision. Up to 570 kw Up to 11,700 kw multiflam burners Innovative Weishaupt technology for large burners: Minimal emission values particularly at ratings over one megawatt. Oil, gas and dual fuel burners with patented fuel distribution system. Up to 17,000 kw WK industrial burners Modular powerhouses: Adaptable, robust, powerful. Oil, gas and dual fuel burners for industrial plant. Up to 22,000 kw Thermo Unit The Thermo Unit heating systems from cast iron or steel: Modern, economic, reliable. For environmentally friendly heating. Fuel: Gas or oil as desired. Up to 55 kw Thermo Condens Heat pumps Solar systems The innovative condensing boilers with the SCOT system: Efficient, low in emissions, versatile. Ideal for domestic heating. Floor standing gas condensing boiler with ratings of up to 1200 kw (cascade), for higher heat demands. The heat pump programme offers solutions for utilisation of heat from air, soil and ground water. The systems are suitable for refurbishment or new builds. It is possible to use several heat pumps in cascade operation. Free energy from the sun: Perfectly coordinated components, innovative, proven. Pleasantly shaped flat roof collectors to support heating and of domestic water Up to 1,200 kw Up to 130 kw Water heater / energy reservoir The attractive domestic water heating range includes classic water heaters which are supplied through a heating system and energy reservoirs which can be fed through solar systems. Control technology / building management From control panels to complete building management systems at Weishaupt you can find the entire spectrum of modern control technology. Future oriented, economical and flexible. 83277702 1/22-04 La