K Series - Fire Suppression Systems for the Catering Industry

Similar documents
KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems

CORE Protection Fire System Specification

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

FIRE PROTECTION SYSTEM FOR INDUSTRIAL KITCHENS

Fire Suppression Systems

AUTOMATIC FIRE SUPPRESSION SYSTEMS

The Amerex Advantage - Quality Experienced Innovation Made in the USA

LPG ProteK. for commercial kitchens

With CV Technology products and care, you ll be better protected from dust explosions.

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

Aerosol Type Fire Extinguisher Aerosol Type Fire Extinguisher

ANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.

WATER MIST CONVENTION AND EXHIBITION

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

How can you minimize consequential damages in case of a fire?

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website: DASPOS USA, Inc NE 116th Street, PMB

Protective & Marine Coatings Europe, Middle East, Africa & India

What extinguishes fires without pressure peaks?

Solutions. Fire risk under control in welding fume extraction systems

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire protection for emergency power supply

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Cadet Entry Level Award(ELA) Part Four. Fire Safety

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

THE WORLD LEADER. in special hazard fire suppression solutions

GHS VSD+ SOLUTIONS FOR CENTRALIZED VACUUM

LOGIC CONTROLLED DEKO 25 EASE OF USE

Portable Ventilation Fans

Basic Vehicle Fire Protection Manual

Genesis Series 5,5 to 22 kw. Compressed air at your service

Design and Supply of Fire Equipments. External Fire Fighting Systems.

Dräger Pac 7000 Single-Gas Detection Device

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

Don t Compromise on Fire Safety Choose Certified Quality Products

Employers Responsibilities

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

Mist-Tech Fire Fighting Equipment

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

Steel, Civil, MEP & Telecommunication Infrastructure Service Providers MEP Profile

- CONSTRUCTION FIRE SAFETY STANDARDS

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Local area fire protection using automatic suppression

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

arm wire free solutions nurse call personal security fire alarms

Extinguishers. Commercial Industrial High rise buildings

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

PDF- VERSION ADJUSTED FROM THE BROCHURE. tissue. How to protect tissue mills from fire

Datalogging as standard

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Datasheet Automatic Protection System for Vehicle Engine Rooms Model: BPS

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

So what is a fire hazard?

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Fixed High Volume Water Spray System fireward.co.uk

Fire suppression systems for server rooms and data centres

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

HSHP HIGH PERFORMANCE DRUM HEATER

Prevention of Fires and Dust Explosions within the Biomass Handling Process. PFI July 20, 2015

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

SMOKE CONTROL - NEW DIRECTIONS

Condensing Units CUS 15-60

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Local area fire protection using automatic suppression

Ships and marine technology Fireextinguishing. of galley cooking equipment

intrinsically safe detector for hydrocarbon gases

THE IDEAL SOLUTION FOR KITCHENS

FIGHTING FIRE as easy as blowing out a match

The S tat-x F irs t R esponder. A new innovation in fire suppression

How can I protect invaluable assets and the environment from the effects of a fire?

Dräger Bump Test Station Calibration and Bump Testing

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

What provides highly reliable fire protection?

Powder Extinguisher ABC - composite Portable powder extinguishers

Model BR660VA Heat Engine

Twin-Agent Fire Fighting/Securing Systems Specifications

Kiddie After Discharge Clean-Up

that sense s of ecurity

Dräger Pac 8500 Single-Gas Detection Device

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

The new generation. Solus. for straight stairs. Better by design

BLABO. Non-man entry tank cleaning and oil recovery system. Automated tank cleaning and. Designed for large, containing crude oil or heavy fuel oil

FOREFRONT AT THE OF PROTECTION

SECURITY BLANKET Foam Fire Protection Products

Element C3.4 Fire Fighting Equipment

Transcription:

K Series - Fire Suppression Systems for the Catering Industry Technical Overview The System Concept The K-Series fire protection systems are fully engineered and as such are designed to meet the individual requirements of the kitchen facility being protected. The Nobel concept is simple and provides the customer with a tailored package to offer the greatest protection, integration and flexibility at a price that offers real value for money. Every system is designed following a comprehensive risk assessment not only considering the basic fire protection requirements but the clients business as a whole. Appliance Protection A full assessment is made of the extract canopy and the cooking appliances present that utilise or produce oils and fats as part of the cooking process. From that information the configuration, choice of nozzle type and system size is established. All cylinders, nozzles and pipe work are manufactured from stainless steel giving excellent durability and long service life. They also give an easy wipe down surface to aid cleaning. Clean simple design Extended Protection Consideration must always be given to the extract duct work system. Part of the risk analysis is to assess the level of risk presented by fire spread to adjoining areas. The Nobel K-Series is one of the only systems on the market to be able to offer extended duct protection and effectively cover the cooking installation to the outside of the building. Suppression and post fire security Extended duct work protection available Fire is a chemical reaction which occurs in the presence of heat, oxygen and fuel. Although the removal of only one of these elements will usually suppress a fire the Nobel K-Series is designed to achieve superior performance by addressing all three simultaneously. Heat The constituents of the Nobel K Wet Chemical react with the free radicals within the flames and rapid knockdown of the fire is achieved. Continued application of the liquid cools the cooking oil to below its auto ignition temperature. Oxygen Nobel stainless steel misting nozzles The Nobel K liquid reacts chemically with the burning oil or fats to produce a reaction known as saponification. This produces a foam like layer on top of the cooking oil, effectively cutting off the supply of oxygen. Fuel The foam like layer on the surface of the oil reduces the volume of flammable vapour that is produced. Although the oil itself can not be removed, the fire system control panel can automatically isolate gas and electricity supplies to shut off source fuels. It is vitally important that services are automatically isolated in every case to prevent constant heat build up. System manufactured in stainless steel K-series Maxell print.indd 1 28/11/2014 13:23

K-Series fire suppression systems For the Catering Industry Cylinders The K-Series fire protection systems are electrically controlled, with no moving mechanical parts. Three basic stainless steel cylinder sizes make up the family and consists of 5 ltr, 15 ltr. and 30 ltr. capacity. These can be used as single units or in combinations for complete flexibility. Each cylinder is designed to BS EN 5500 and are constructed with inbuilt safety devices as standard. All cylinders are individually pressure tested at manufacture and have unique identification for complete traceability. Control Every system has an NFS3, 4 or Solo electrical control panel manufactured to the latest CE standards. The panel receives a signal from the detection device and automatically actuates the discharge circuitry. It is equipped with a manual actuation facility to override automatic detection and discharge the system manually. The panel constantly monitors detection and actuation circuits for fire and faults and has 72hr battery backup in case of mains failure. Wet Chemical Liquid Suppression Medium All the systems are charged with a wet chemical liquid as the suppression agent. Nobel-K has been specifically formulated to react chemically with class F (K) burning oils and fats. A near neutral ph value of 7.8 ensures that the liquid does not cause any harm to the kitchen equipment and is safe and easy to clean up after discharge. 5, 15 and 30 ltr. cylinders K Liquid, near neutral ph Gas Generator Technology The gas used to propel the liquid through the pipe work and onto the fire is produced by a Gas Generator. This unique device provides the fire system with a controlled constant flow of gas resulting in a constant pressure / time profile within the cylinder. In turn the nozzle is also provided with liquid at the optimum performance pressure. This feature gives increased efficiency over other methods of expellant production as the system remains at Zero pressure until a fire condition occurs. ( The possibility of stored gasses leaking prior to actuation is eliminated ). Fire Detection The fire suppression system can utilise all types of detector. However the type used in our LPS 1223 approved system incorporates all new intelligent thermal sensing devices.these stainless steel ultra fast reaction sensors are chemical and abrasion resistant and are placed in the canopy/hood behind the filters over the cookline. This method gives a extremely fast and reliable, unobtrusive and easy clean method of detection. In addition when protection needs to be extended into the duct to protect the rest of the building, seamless additions can be made to supplement and enhance the protection levels throughout. NFS 3 panel Gas generators NFS 4 panel Installation Most installations can be carried out in approximately half the time of other kitchen fire suppression systems. The K-Series is installed using only high quality stainless steel fittings, pipe work and nozzles as standard. Each nozzle is protected using a metal or rubber blow off cap to ensure no blockages occur in the harsh kitchen environment. Maintenance Unlike other systems on the market the K-Series are monitored for both fire and fault conditions, giving audible and visual indications of both. Due to the communication, simplicity and robust design, maintenance requirements are kept to a minimum, reducing the customers ongoing ownership costs. The system is approved and certified to LPS1223 and to ISO 15371:2009 and is type approved by MCA, ABS, DNV GL, Lloyds, and Korean Register Nobel Fire Suppression System Control Panel Suppressant Fuel shut down Gas or Electric Ducting Filter Remote manual release Electrical Wiring Heat Detector Pipe Nozzle Manufacturer Nobel Fire Systems Ltd 7 Quest Park Moss Hall Road Heywood Lancashire BL9 7JZ United Kingdom T +44 (0)1706 625 777 F +44 (0)1706 625 325 E sales@nobel-fire-systems.com www.nobel-fire-systems.com Distributor Maxell International LLC PO Box 47620 Warehouse No.10 Plot No. 247-112 Al Qusais Industrial Area 4 Dubai UAE T +971 4 259 2821 F +971 4 259 2831 E info@maxellinternational.com www.maxellinternational.com