TWXC F3 Series 50Hz. Water Cooled Horizontal Screw Chiller Flooded Evaporator Cooling Capacity: 97 to 506 TR (340 to 1780 kw)

Similar documents
Commercial Air Conditioners 2017/2018

Water Cooled Screw Chiller Flooded type kW (R134a) Direct expansion type kW (R22)

MODELS LIST. Nominal Capacity RT

High COP. Water-Cooled Screw Chiller

3 0 H X C A - H P 2

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

DAIKIN Huizhou Factory Profile

COMMERCIAL AIR CONDITIONERS M Type Air Cooled Screw Chiller 2012

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30HXC Nominal cooling capacity kw

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Modular Water Cooled Water Chiller

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

.2 Section Waste Management and Disposal.

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

ERACS.C-N Higher efficiency air-cooled screw pump

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

Hitachi Centrifugal Chillers

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

OIL FREE CENTRIFUGAL CHILLER

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Leadership, Innovation, Advanced Technology Synergise Here!

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Water-cooled Centrifugal Chiller

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

ARV.

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

MAC-A R410A Series Air cooled Modular Chiller

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

DAIKIN Modular Inverter Air Cooled Chiller

Air Cooled Scroll Chiller

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Midea R134a 50Hz l Flooded type water cooled screw chiller (PCB Control)

WATE R -C OOLE D WATE R C H ILLE R S

Call us today! (800)

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

30KAV Variable Speed Air-cooled Screw Chiller

Call us today! (800)

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Call us today! (800)

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Water-Cooled Dual Compressor Screw Chiller

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

The High-efficiency Air-cooled Chiller "H series"

Outstanding Performance; Application Flexibility

Hi-Pres Cooling Products Catalogue. Product Catalogue

AQUASNAP JUNIOR 30RHV

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Conditioning your ambient, maximising your comfort.

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Modular Air Cooled Scroll Chillers

CASE STUDY AIR-CONDITIONERS

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Air-Cooled Condensing Units with Compact Screw Compressors

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

H4T R410A. refrigerant

Water-cooled chillers with High Speed Centrifugal Compressors

The High-efficiency Water-cooled Chiller "H series"

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

GENERAL TABLE OF CONTENTS NOMENCLATURE DCLC D V

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Innovation for a Better & Greener Future

MODULAR CHILLER. R410a R22

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Chilled Water Precision Air Conditioner for Critical Application

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Nirvana. Cycling Refrigerated Dryers

MEDICAL CHILLER SYSTEMS

1

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

SYSTEM DESIGN REQUIREMENTS

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

30RB /30RQ

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Transcription:

TWXC F3 Series 50Hz Water Cooled Horizontal Screw Chiller Flooded Evaporator Cooling Capacity: 97 to 506 TR (340 to 780 kw)

Contents Contents 02 Nomenclature 03 Features and benefits 07 Specifications 0 Dimensions 8 Selection software

R34a Flooded (97 to 506 tons) TOPIRE water cooled screw chiller is the mature products which use flooded type evaporator and high efficiency compressor. Optimized system design and enhanced heat exchange efficiency make the unit working best under both full load and partial load. Every chiller is fully factory tested and gas charged in the factory before dispatch. It s good choice for hotel, shopping mall, hospital, factory, cinema and other civil architecture air conditioning system. Besides, it is widely used in plastic industry, electroplating industry, food processing, chemical industry and other technological process which needs plenty of chilled water. TWXC - F3 TOPIRE Water-Cooled Horizontal Screw Chiller Model Code Refrigerant type F3: R34a Structure Electrical control panel Touchscreen panel High efficiency screw compressor Flooded type evaporator Emergency button Safety release valve Shell and tube condenser Electronic expansion valve Fast connection victaulic fitting 2

Features and benefits Green chiller R34a Flooded (97 to 506 tons) R34a environmentally-friendly refrigerant: Refrigerant is chlorine-free HFC with zero ODP (Ozone Depletion Potential). Very low GWP (Global Warming Potential). Stable and Reliable dvanced twin-rotor screw compressor djustable capacity valve Four stage adjustable capacity or stepless adjustment. Built-in oil separator High precision filter, oil separation efficiency up to 99.5%. Direct motor drive High mechanical efficiency, low compressor speed, low noise levels. Refrigerant discharge Exhaust cavity with check valve, it helps avoid extended stoppages caused by compressor reversal. Twin screw rotor Patented type line design, high volumetric efficiency, smooth operation. Hermetic motor Refrigerant cooled motor, no expelled heat. Semi- hermetic structure Semi-hermetic compressor, moveable bolts, easy maintenance. High efficiency heat exchange technology Evaporator Condenser Gas refrigerant Chilled water outlet Filter Gas refrigerant inlet Filter Cooling water outlet EXV Liquid refrigerant Tube Chilled water inlet Liquid refrigerant outlet Cooling water inlet Orifice High efficiency shell and tube heat exchanger, 2 pass, straight water pipe, easy to clean. Both two side cover can be exchanged to meet customer s requirement for condenser. 3

R34a Flooded (97 to 506 tons) dvanced oil system doption of the special oil separation and return system, built-in oil separator, ensure the systems' stability.the lubrication system can heat oil to match the chillers exact requirements, guaranteeing the system is always protected against unnecessary wear. User-friendly operating interface Complete and safe control system: The unit is designed with multiple security measures to ensure safety and reliability. ll sensors and safety features are assembled, equipped and undergo strict testing in factory. Touchscreen display: Color coded, easy for operation. Three status indicators on the screen clearly indicate power, system status and counication Intelligent control By monitoring all parameters, the intelligent control logic decides the best load adjustment method, it optimizes the EXV and the capacity slider to guarantee safe operation under various load conditions. Conventional BMS systems only focus on the interlock control, operation status and parameter monitoring, which achieves automation and energy management,but fails to realize the benefits of equipment synchronization. Topaire centralized energy management system attaches importance to building load prediction and control, and coordinates the operation of air-conditioner, fan and water pumps to realize optimum energy management. System control functions: Pragmatic control modes Equalized operation time Touchable Screen Central Controller Electricity panel Optimum operation schedule System data report Strategies to address problems Remote counication function Pressure difference sensor Temperature sensor Water flow meter Electrical operated valve Chilling water pump Chilled water pump Cooling tower Centrifugal Chiller Centrifugal Chiller Screw Water Chiller 4

Electrical control R34a Flooded (97 to 506 tons) Topaire intelligent controller Topaire water cooled screw chiller adopts a Microprocessor controller which enables the user to monitor and control the chiller with precise accuracy. The Microprocessor control system guarantees high precision and stability. The moduledesigned control system is easy for installation and maintenance. The chiller comes with a reserved RS485 port which can be interfaced with BS (Building utomation system). Remote monitoring and control of the chiller is possible. True color touchscreen Control regulations,operating parameters, diagnostics reports, and error messages are all displayed on a 7 inch, 65636 colors TFT screen with 800 480 resolution. The screen also displays error codes, various settings, specified temperature and pressure values, the status of operating parameters and options. Weekly operation scheduling The user can set the chiller operation schedule on the weekly timetable to run and stop the chiller automatically. If an unscheduled shutdown occurs, the chiller will not restart unless manually reset. Power-down memory function When powered-down, the chiller will maintain previous running mode and parameter set point. 5

R34a Flooded (97 to 506 tons) Data acquisition & storing Records a max. of 256 of the lastest alarms and 500 seconds of chilled/cooling water temperature trend display. Password protection user, installation and coissioning technician as well as a factory password are pre-generated for each unit. Unauthorized access to the control is protected by randomly-generated passwords. Self-Diagnosis Self-diagnosis is always performed prior to start-up to enable safe operation. Only after all the requirements are met, the chiller will start. If any malfunction occurs, it will be displayed on the screen. Multiple protection features guarantee the safety and stability of the unit Items High/low pressure protection Power open phase protection nti-freeze protection under cooling mode Frequent startup protection Overcurrent protection of Comp. Overheat protection of compressor Water flow protection Reversal protection control(prs) Function Guarantees the Comp. runs in the right range thus ensuring its lifespan Protects Comp. from damage in case of open phase or anti-phase Protects the evaporators' copper pipes from damage caused by water freeze Protects Comp. motor winding from burnout caused by frequent startup Protects Comp. from burnout caused by heavy current Protects Comp. from damage caused by a lack of refrigerant or lubricant Protects Comp. from burnout caused by heat-exchanger failure Guarantees the comp. motor runs in the right direction 6

Specifications TWXC_F3 00 25 55 20 230 255 Cooling capacity RT 96.7 25. 53.5 204.7 228.9 253. Cooling capacity kw 340 440 540 720 805 890 R34a Flooded (97 to 506 tons) Power input COP Semi-hermetic screw compressor kw kw/kw 60.0 77.0 94.0 27.5 44.3 55.0 5.66 5.7 5.74 5.64 5.57 5.74 Circuit Circuit B Quantity Quantity Oil recharge Circuit L 8 20 23 28 40 40 Circuit B L Refrigerant Type R34a Circuit kg 30 45 60 230 230 250 Circuit B kg Control Type EXV+Orifice Evaporator Type Shell and Tube Flooded Water flow m 3 /h 58.46 75.67 92.88 23.8 38.5 53. Pressure drop kpa 30.0 32.3 32.2 27. 33.2 33. Max. pressure kpa 000 000 000 000 000 000 Connection Type Victaulic coupling Water inlet/outlet pipe dim. DN50 DN50 DN50 DN200 DN200 DN200 Condenser Type Shell and Tube Water flow Pressure drop m 3 /h kpa 73.2 94.6 6. 54.8 73. 9.4 38.0 39.7 40.2 37.0 40.0 42.8 Max. pressure kpa 000 000 000 000 000 000 Connection Type Victaulic coupling Water inlet/outlet pipe dim. DN50 DN50 DN50 DN200 DN200 DN200 Unit length Unit width Unit height Packing length Packing width Packing height Net weight Shipping weight Running weight kg kg kg 3496 3496 3496 352 352 352 200 200 200 400 400 400 76 768 848 928 2026 2026 3950 3950 3950 3950 3950 3950 340 340 340 560 560 560 950 2020 220 2220 2240 2240 2380 2460 2830 3400 3900 4000 2525 2540 2875 3550 3950 4030 255 2560 2935 3770 480 4270 Note: Nominal cooling capacities are based on following conditions: Chilled water inlet/outlet temperature 2/7 C(53.6 F /44.6 F); Cooling water inlet/outlet temperature 30/35 C(86 F /95 F). The design fouling factor for evaporator is 0.076m 2 C/kW(0.000ft 2 F.hr/Btu) and for condenser is 0.044m 2 C/kW(0.00025ft 2 F.hr/Btu). 7

R34a Flooded (97 to 506 tons) TWXC_F3 300 340 370 400 460 50 Cooling capacity RT 300 34.2 369.6 400.9 460.6 506. Cooling capacity kw 055 200 300 40 620 780 Power input COP Semi-hermetic screw compressor kw kw/kw 86.6 206.0 23.7 242.7 278.0 306.0 5.65 5.82 5.6 5.8 5.82 5.8 Circuit Quantity Circuit B Quantity Oil recharge Circuit L 40 28 28 28 40 40 Circuit B L 28 28 28 40 40 Refrigerant Type R34a Circuit kg 360 65 65 70 200 200 Circuit B kg 65 65 70 200 200 Control Type Evaporator Type EXV+Orifice Shell and Tube Flooded Water flow m 3 /h 8.5 206.4 223.6 242.6 278.6 306.2 Pressure drop kpa 32.7 63.0 7.0 64.9 7.0 77.0 Max. pressure kpa 000 000 000 000 000 000 Connection Type Water inlet/outlet pipe dim. Condenser Type Victaulic coupling DN200 Shell and Tube Water flow m 3 /h 226.9 257.9 279.5 303.2 348.2 382.7 Pressure drop kpa 37.7 72.2 8.7 8.9 83.9 86. Max. pressure kpa 000 000 000 000 000 000 Connection Type Water inlet/outlet pipe dim. Victaulic coupling DN200 Unit length 3588 4593 4593 4593 4820 4820 Unit width 500 500 500 500 600 600 Unit height 268 2002 2002 2002 2230 2230 Packing length 3950 5050 5050 5050 5050 5050 Packing width 660 2080 2080 2080 280 280 Packing height 2370 2255 2255 2255 2470 2470 Net weight kg 4520 660 6690 6940 8090 890 Shipping weight kg 570 622 6292 6340 7590 770 Running weight kg 5430 6432 652 660 80 8260 Note: Nominal cooling capacities are based on following conditions: Chilled water inlet/outlet temperature 2/7 C(53.6 F /44.6 F); Cooling water inlet/outlet temperature 30/35 C(86 F /95 F). The design fouling factor for evaporator is 0.076m 2 C/kW(0.000ft 2 F.hr/Btu) and for condenser is 0.044m 2 C/kW(0.00025ft 2 F.hr/Btu). 8

R34a Flooded (97 to 506 tons) Dimensions Single Compressor (TWXC 00 ~ 300 F3) Cooling water outlet Cooling water inlet C Chilled water inlet Chilled water outlet G K F L H J E B Model B C D E F G H J K L D Unit: TWXC 00 F3 3496 200 76 2850 00 4 260 300 600 260 54 DN50 TWXC 25 F3 3496 200 768 2850 00 4 260 300 600 260 54 DN50 TWXC 55 F3 3496 200 848 2850 00 4 260 300 600 260 54 DN50 TWXC 20 F3 352 400 928 2850 300 44 300 350 700 300 59 DN200 TWXC 230 F3 352 400 2026 2850 300 44 300 350 700 300 59 DN200 TWXC 255 F3 352 400 2026 2850 300 44 300 350 700 300 59 DN200 TWXC 300 F3 3588 500 268 2850 400 443 350 375 750 375 68 DN200 Water inlet/ou tlet Dual Compressor (TWXC 340 ~ 50 F3) Cooling water outlet Cooling water inlet C Chilled water inlet Chilled water outlet G K L F H J E B D Model B C D E F G H J K L Unit: TWXC 340 F3 4593 500 2002 3850 400 443 350 375 750 350 68 DN200 TWXC 370 F3 4593 500 2002 3850 400 443 350 375 750 350 68 DN200 TWXC 400 F3 4593 500 2002 3850 400 443 350 375 750 350 68 DN200 TWXC 460 F3 4820 600 2230 3850 500 468 350 400 800 350 643 DN200 Water inlet/ou tlet TWXC 50 F3 4820 600 2230 3850 500 468 350 400 800 350 643 DN200 9

Electrical data TWXC_F3 00 25 55 20 230 255 300 340 370 400 460 50 Standard voltage V 400V 3Ph 50Hz R34a Flooded (97 to 506 tons) Voltage range V 380~45 Max. running current 4.4 69.4 206. 28.2 33.7 366.8 405.9 454.8 562.3 562.3 663.5 733.6 Max. power consumption kw 83.70 00.5 23.2 68.3 92.8 24.4 242.2 272.0 336.6 336.6 380.6 428.8 Rated current 03.2 30.4 62.7 29. 254.8 269.6 330.5 356. 396.3 429 54.9 532.3 Compressor Locked rotor mps. 80 875 340 990 2260 2260 3090 430 990 990 2260 2260 Max. allowed current 4.4 69.4 206. 28.2 33.7 366.8 405.9 227.4 28. 28. 33.7 366.8 Rated current 03.2 30.4 62.7 29. 254.8 269.6 328.9 78.0 98. 24.5 257.4 266. Rated power kw 60.00 77.00 94.00 27.5 44.3 55.0 86.6 03.0 5.8 24.8 45.7 53.0 Compressor B Locked rotor mps. 430 990 990 2260 2260 Max. allowed current 227.4 28. 28. 33.7 366.8 Rated current 78.0 98. 24.5 257.4 266. Rated power kw 03.0 5.8 24.8 45.7 53.0 Crankcase heater Voltage V 220 220 220 220 220 220 220 220 220 220 220 220 Total input kw 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.6 0.6 0.6 0.6 0.6 Total mps..36.36.36.36.36.36.36 2.72 2.72 2.72 2.72 2.72 Note:. Customer to specify the exact nominal power supply available on site so that correct electrical components are selected. 2. Main power must be supplied from a single field supplied and mounted fused circuit breaker. 3. The compressor crankcase heaters must be energized for hours before the unit is initially started or after a prolonged power disconnection. 4. ll field wiring must be in accordance with local standards. 5. Neutral line required on 380V-3Ph-50Hz(5 wires) power supply. 6. Rated load amperage values are nominal conditions. 7. ±0% voltage variation from the nominal conditions is allowed temporarily only,not permanently. 0

R34a Flooded (97 to 506 tons) Pressure drop Flooded type (Evaporator) Water pressure drop(kpa) 60 50 40 30 20 0 Water pressure drop curve (evaporator) 0 0.0 50.0 00.0 50.0 200.0 250.0 Water flow (m 3 /h) TWXC 00F3 TWXC 25F3 TWXC 55F3 TWXC 20F3 TWXC 230F3 TWXC 255F3 TWXC 300 F3 Water pressure drop(kpa) 20 00 80 60 40 20 0 Water pressure drop curve (evaporator) 0.0 50.0 00.0 50.0 200.0 250.0 300.0 350.0 400.0 Water flow (m 3 /h) TWXC 340F3 TWXC 370F3 TWXC 400F3 TWXC 460F3 TWXC 50F3 Flooded type (Condenser) 70 Water pressure drop curve (condenser) 40 Water pressure drop curve (condenser) Water pressure drop(kpa) 60 50 40 30 20 0 Water pressure drop(kpa) 20 00 80 60 40 20 0 0.0 50.0 00.0 50.0 200.0 250.0 300.0 Water flow (m 3 /h) 0 0.0 00.0 200.0 300.0 400.0 500.0 Water flow (m 3 /h) TWXC 00F3 TWXC 25F3 TWXC 55F3 TWXC 20F3 TWXC 230F3 TWXC 255F3 TWXC 300 F3 TWXC 340F3 TWXC 370F3 TWXC 400F3 TWXC 460F3 TWXC 50F3 pplication Range Items pplication range Condenser water entering temperature Evaporator water leaving temperature Water flow volume 25 C~35 C 5 C~5 C Flow volume rating ±20% Temperature difference 4~8 C Fouling factor (m 2. C/kW) Evaporator: 0.076, condenser: 0.044 Voltage tolerance Voltage rating ±0% Phase tolerance Power supply frequency Evaporator max. working pressure on water side Compressor max. start count Environment quality Drainage system Storage and transport temperature RH(relative humidity) pplicable altitude range ±2% Frequency rating ±2%.0MPa 4 times/h 8times/day Highly corrosive environments and high humidity should be avoided. The height of water drainage should not be higher than the base of the unit. -25 C~55 C In + 40 C does not exceed 50%, + 25 C no more than 90% No more than 000m

R34a Flooded (97 to 506 tons) Installation requirements: Be sure to take the base preparation and structure into consideration seriously during installation,particularly on rooftop installations in order to avoid noise and vibration.consulting the building designer before conducting installation is recoended. drainage ditch should surround the base to ensure dewatering occurs. nti-vibration pad is to be placed between the base frame and foundation in order to avoid vibrations and unnecessary noise, and make sure the unit is aclinic during installation. 2 3 4 5 Typical Isolation structure 2 3 4 5 nchor Bolt Chiller Frame Base Rubber Pad Steel Base Plate Concrete Base Notes: The maximum altitude difference (levelness) should be within 3 for the chiller base. The base should be raised 00. The installation base of the unit must be concrete or steel structure, which can bear the running weight of the machine. The top should be horizontal. It is ideal to prepare a drainage ditch around installation base. Put the steel plate and anti-vibration pad in the correct position. Finish the installation of the unit and the foundation bolt before secondary concreting. The foundation bolt should protrude 00. Spring isolators are specified on the sales order as an option. Unit bottom Unit bottom Spring shock absorber Foundation Rubber pad Foundation Steel plate (thickness 5) Spring isolator Rubber pad 2

R34a Flooded (97 to 505 tons) Isolator Position the absorbers under the unit saddles before final positioning of the unit. The quantity of absorption used for each unit is always decided by the elasticity or durometer value of the absorber. Below please refer to the typical isolation pad and vibration isolator for selection. Typical isolation rubber pad Typical spring isolator 80MM 22MM 70MM 200MM tk 0MM top face 20MM Load value for reference Isolation pad Vibration Isolator Model Minimum load bearing (kg/e) Minimum Quantity Minimum load bearing (kg/e) Quantity TWXC 00 F3 900 4 900 4 TWXC 25 F3 000 4 000 4 TWXC 55 F3 200 4 200 4 TWXC 20 F3 400 4 400 4 TWXC 230 F3 800 4 800 4 TWXC 255 F3 800 4 800 4 TWXC 300 F3 2000 4 2000 4 TWXC 340 F3 2200 4 2200 4 TWXC 370 F3 2200 4 2200 4 TWXC 400 F3 2200 4 2200 4 TWXC 460 F3 2200 4 2200 4 TWXC 50 F3 2200 4 2200 4 Note: () Pads have to extend the full length of the saddle when isolation pads are used. (2) Level the unit to within 5 over its length and width after absorbers are installed. 3

Foundation dimensions Drainage ditch R34a Flooded (97 to 506 tons) B E+500 E Evap Centre Line Cond Centre Line L B F R Front side of chiller D D+500 nchor Bolt M20X400 (Provided by user) Nut M20 (Provided by user) Gasket 200 (Provided by user) 00 45 - Chiller Leg Rubber Pad (δ 5) 200X200 Steel Base Plate ( δ 0) 200X50 (Provided by user) 300 400 50X50 Grout concrete after chiller is placed Model TWXC_F3 Dimensions 00 25 55 20 230 255 300 340 370 400 460 50 D() 2850 2850 2850 2850 2850 2850 2850 3850 3850 3850 3850 3850 E() 00 00 00 300 300 300 400 400 400 400 500 500 4

R34a Flooded (97 to 506 tons) Typical piping system ll piping should be installed independently in order to convey any stress and vibration to the chiller and have sufficient space for maintenance. Water flow switch is required and should be installed on the straight line (5 times the pipe diameter) of the Chilled/Cooling water outlet. It is recoended to install a thermometer and pressure gauge to measure the units operational condition. Notes: The diagram is the recoended water system schematic, some changes may be required to accoodate local conditions. utomatic Watering To Drain ExpansionTank Collector Distributer Flexible connection Check Valve Y-Shape Strainer Pressure Gauge uto vent valve Drain Valve Stop Valve Water Pump Temperature gauge Water Flow Switch 3-Way Valve Suggestion for energy conservation:. Choose the right pressure head for chilled water pump and cooling water pump. Choose proper pipe diameter and water velocity. Minimize pipe joint, reducing joints, pipe reducers, manifolds, and valves unnecessary to reduce local resistance loss. Choose proper water strainer (structure/meshes) and periodically clean. 2. Using a variable frequency water pump is recoended as it can reduce energy consumption by 30%-45%. 3. Using a water distributor and valves between floors or terminal SV to prevent chilled water from circulating in non-working terminals is recoended. 4. Do periodic cleaning of cooling tower and pipe system. 5. Select a location that provides sufficient air-flow for both air-inlet and outlet. 6. Make appropriate adjustments to chilled water inlet/outlet temperature and temperature difference according to the local climate. 5

Optional accessories NO. Name Model Instructions Picture Quantity R34a Flooded (97 to 506 tons) Vibration damper reduces vibration and noise by Vibration damper SH series isolating the supports from the 4 floor. Can be installed in the control room through the cable connected to the unit touch screen. It can display all status 2 Remote control cabinet YCKZ-P information and complete all the unit operations(startup/shutdown, error confirm, etc.) Flange connection can be chosen for water pipe 3 Flange JB8/94 Standard flange connection. Customer can choose water side pressure.6mpa according to requirements. 8 Optional items Name Content Power supply 400V 3Ph 50Hz is standard. Water inlet/outlet connection Victaulic type connection is standard for the condenser and evaporator. Flange type connection is optional. High pressure water box Standard water box can sustain.0mpa pressure..6mpa or 2.0Mpa pressure is optional. Chiller vibration isolator Spring isolator and rubber pad are the optional accessories from the factory. Four steps compressor control Stepless compressor control is standard and capacity adjust in four steps is optional. High entering condenser water temperature High entering condenser water entering temperature up to 35 C. Multi unit centralized control Multiple units centralized control is optional (Chiller plant manager). PLC (Prograable Logic Control) The standard electrical controller is Microprocessor and PLC is optional for various applications. Remote control & monitor panel Remote control & monitor panel for easy operation on site. BMS (Building management system) Open protocol RS 485 which is BMS compatible (BCnet or LonWorks). Witness performance testing Factory can arrange testing observation for customers. 6

Selection software Selection software Professional selection software makes the product selection process much easier and more efficient than conventional manual selection. Simple operating interface and smart arithmetic greatly improves selection efficiency. The user simply needs to provide several basic parameters, such as cooling capacity, fouling factor, power supply, etc. The program will then display all suitable models for easy selection.this software can be conveniently updated online. If you have any questions please feel free to contact us. We reserve the right to make change in design and construction at any time without notice. 7

Head Office TOPIRE SLES & SERVICES SDN BHD (274725-W) No.7-2-2, Block, Megan Salak Park, Jalan 2/25E, Taman Desa Petaling, 5700 Kuala Lumpur. Tel : 603-90563228 (Hunting line) 603-9056288 / 603-90562868. Fax : 603-90562800. Email : tass@topaire.com.my Manufacturer Manufacturer Manufacturer www.topaire.com.my Branches Penang No 4, Lengkok Kikik 2, Taman Inderawasih, 3600, Prai, Pulau Pinang. Tel: 04-399 2050/ Fax: 04-398 2050 Johor Bahru No. 62, Jalan Permas Jaya 9/3, Bandar Baru Permas Jaya, 8750 Johor Bahru, Johor Darul Takzim. Tel: 07-388 4600/ Fax: 07-388 4602 Kota Bahru Lot 848, Jalan Hospital, Kg. Cherang, Taman Kenangan, 5200 Kota Bahru, Kelantan. Tel: 09-748 9295 Fax: 09-748 9297 Melaka DT 3662, Jalan ngkasa Nuri 2, Taman ngkasa Nuri, 7600 Durian Tunggal, Melaka. Tel: 06-332 027 Fax: 06-337 2360 Sabah Lot 2, (DBKK No.69) Lorong Inanam 5 3/4 Miles, Tuaran Road, 88450 Kota Kinabalu, Sabah. P.O. Box 526, 88857, Inanam, Kota Kinabalu, Sabah Tel: 088-388 339 Fax: 088-389 339