LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Similar documents
LCS 2 YOUR digital infrastructure

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

/Oct/2014 Rev B

Compact Module. Category 6A FTP Cabling System 1.1

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Live. it does the rest. room control system for hospitality buildings. global specialist in electrical and digital building infrastructures

Product Specification Qualification Test Report

Cat 6 Unshielded Patch cords

AMP NETCONNECT Category 5E SL Shielded Cabling System. 1. General Description

Cat 6 Shielded Patch cords

infrastructure for 10, 40 and 100Gbits/s readiness

Product Specification CAT 6 UNSHIELDED PATCH CORDS

/Oct/2014 Rev E

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

simply fits your needs

ENVIRONMENTAL PRODUCT DECLARATION PANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED

SHOPPING CENTERS AND SH INTEG RATED SO LUTIO N S THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

A. The requirements of this Section and the other Division 26, 27 & 28 Sections apply to all the video surveillance system work.

The Next Generation of Data Communicatons Solutions

CATEGORY 6A FTP RJ45 SOLUTION

Mar11 Rev B

Fibre optic media options and trends

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

Secure WANDERING INSTALLATION AND USAGE GUIDE

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

Universal Connectivity Platform

Enter the Céliane TM era

Set-Up Procedures. Before You Start

LexCom 19" patch panels. Put your hands on innovation

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

Fibre (TIA) Field Test Specification

Telephone and Data Structured Wiring

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

IFS SFP Tranceivers User Manual

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

PANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED

Multi-Core Fire Resistant Cable

This is a preview - click here to buy the full publication

Clipsal Mining Solutions. Increasing workplace safety. Adding value to mining operations.

This document is a preview generated by EVS

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

ETSI TS V1.2.1 ( )

Fibre Characterisation and FTTx New challenges

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Category 5e Products

INTERNATIONAL STANDARD

NAME OF WORK - IIM AHMEDABAD - LIBRARY BOQ OF ELV WORKS Item #

AMPTRAC Intelligent Infrastructure Management System (IIMS)

Mounting plates for data connection caps

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

commercial-type cabling and connectivity products into the industrial landscape.

Product Specification

Product Catalogue. External Management

INTERNATIONAL STANDARD

PROJECT No.1. Supply, installation and commissioning of HW of GPON. GNC-ALFA CJSC (Rostelecom Armenia)

Call stations and extensions

SMARTHER CONNECTED THERMOSTAT WITH INTEGRATED WI-FI THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES 65% MANUAL MOD HOME

Communication Solutions for Energy Generation, Transmission and Distribution

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

FIRE RESISTANT CABLES

Fibre Solutions for Harsh Environments

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

RACK MONITORING SYSTEM RAMOS Ultra

PQS Independent type-testing protocol

Brochure. Security Designed, Installed by Experts

WG Buried Fibre Cable Long Perimeter Detection System

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

C-Bus Four Channel General Input Unit Installation Instructions

This document is a preview generated by EVS

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

gas monitoring system

INSPIRATION INNOVATION INTEGRATION. Infrastructure Solutions

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

INTERNATIONAL STANDARD

Fiber Optic Products Catalog

INTERNATIONAL STANDARD

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

EESTI STANDARD EVS-EN :2011

BT Cables Technical Seminar. CIBSE CPD Programme

Z-PACK TinMan 85 ohm Connector Overview

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

4 Channel Contact Closure SFP DIN Fiber Link System

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

NOTE TO SPECIFIER: This section is based on the products manufactured by Soundmask Australia Pty Ltd:

IEC NORMAS PUBLICADAS. As normas ISO/IEC já estão relacionadas em normas ISO Publicadas

Proposed Development at Likoni Road, Nairobi for NTSA - Security Systems Installations works bills of Quantities

INTERNATIONAL STANDARD

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

Transcription:

LCS 2 THE CATEGORY 6A GUARANTEE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Legrand is one of the global leaders in data communication networks in the development and design of the most advanced and highest performing structured cabling systems and solutions. They support multimedia networks, applications and emerging technologies.

from technical room to workstation Complete systems with a 20-year guarantee. The new LCS 2 cat. 6A (up to 500 MHz), cat. 6 (up to 250 MHz) and cat. 5e (up to 100 MHz) systems have been designed as coherent entities to optimise their performance. The systems are suitable for fibre optic cables as well as copper cables. WWW.LEGRAND.COM 1

category 6A the high performance solution performances: > 5dB / TIA or 3dB / ISO crosstalk > 3dB / ISO-TIA return loss. Guaranteed category 6A LINK The category 6A solution was designed to significantly exceed all category 6A application requirements in order to offer optimum performance in future applications. With Category 6A, Legrand guarantees installed channel performances exceeding all category 6A crosstalk requirements by 5dB /TIA* or 3dB /ISO* and exceeding all category 6A return loss requirements by 3dB /ISO-TIA* for configurations and installations conforming to standards, as well as on-site testing conducted by verified testing agents. * Depending on the degree of accuracy offered by the tester atthetestpoint. GUARANTEED APPLICATIONS 10Base-T...155 Mbits/s ATM 100Base-TX...270 Mbits/s digital video 1000Base T... Broadband video 1000Base-TX...1.2 Gbits/s (CBIG) ATM 10GBase-T...10 Gigabit Ethernet COMPLIANCE WITH STANDARDS ANSI/TIE/EIA 568-C2 ISO/IEC 11801 (second edition) Class EA amendment 2 100-METER HORIZONTAL CHANNEL The category 6A channel is designed to offer flexibility. Legrand solutions have been designed to optimise application performance by using all standardised channel lengths and configurations. With Legrand category 6A solutions, it is no longer necessary to determine specific installation specifications or particular patch cable width limits. A+B=90m,C+D+E=10m CAT. 6A CHANNEL COMPONENTS -category6a F/UTP cables ref. 0 327 78 -category6a RJ 45 sockets -category6a patch panels -category6apatch cords C Cat. 6A patch cords Cat. 6A patch panels D Cat. 6A patch panels Cat. 6A patch cables A Cat. 6A F/UTP cable B Cat. 6A F/UTP cable Cat. 6A zone distribution box 2 E Cat. 6A patch cords Cat. 6A modular jacks/sockets

category 6A performances The results of independent trials shown below allow comparison of worst performance obtained from a 100-metre channel with 4 connectors conforming with ISO standard category 6A specifications. The significant margins shown for each measured parameter demonstrate the technical superiority of the category 6A solution. These performance margins are consistent across the ISO/TIA standard tested frequency range and even beyond. Fréq. (MHz) Fréq. (MHz) 1 10 100 1000 1 10 100 1000 0 0 20 10 40 20 Next 60 RL 30 80 40 100 50 120 60 NEXT RETURN LOSS Fréq. (MHz) Fréq. (MHz) 1 10 100 1000-40 0 10-20 20 0 1 10 100 1000 30 ACR-N 20 40 PSNext 40 50 60 60 70 80 80 90 100 ACR-N 100 PS NEXT Frequency (MHz) NEXT NEXT ACR-N ACR-N RL RL PS NEXT PS NEXT PS ACR-N PS ACR-N ACR-F ACR-F PS ACR-F PS ACR-F 1 65 68 61 64 19 22 62 65 58 61 63.3 66.3 60.3 63.3 4 63 66 58.9 61.9 19 22 60.5 63.5 56.4 59.4 51.2 54.2 48.2 51.2 10 56.6 59.6 50.1 53.1 19 22 54 57 47.5 50.5 43.3 46.3 40.3 43.3 20 51.6 54.6 42.5 45.5 17.5 20.5 49 52 39.8 42.8 37.2 40.2 34.2 37.2 31.25 48.4 51.4 36.9 39.9 16.5 19.5 45.7 48.7 34.2 37.2 33.4 36.4 30.4 33.4 62.5 43.4 46.4 27 30 14 17 40.6 43.6 24.2 27.2 27.3 30.3 24.3 27.3 100 39.9 42.9 19 22 12 15 37.1 40.1 16.2 19.2 23.3 26.3 20.3 23.3 200 34.8 37.8 4.7 7.7 9 12 31.9 34.9 1.8 4.8 17.2 20.2 14.2 17.2 250 33.1 36.1-0.8 2.2 8 11 30.2 33.2-3.7-0.7 15.3 18.3 12.3 15.3 300 31.7 34.7-5.6-2.6 7.2 10.2 28.8 31.8-8.6-5.6 13.7 16.7 10.7 13.7 400 29.6 32.6-14.1-11.1 6 9 26.6 29.6-17.1-14.1 11.2 14.2 8.2 11.2 500 27.9 30.9-21.4-18.4 6 9 24.8 27.8-24.5-21.5 9.3 12.3 6.3 9.3 WWW.LEGRAND.COM 3

a complete solution A complete system to suit all commercial projects from technical room to workstation. COPPER A complete system up to 10 Gbits/s FIBRE OPTIC A simple and reliable option Connectors Fibre optic drawers Patch cords and cables Connecting fibres Patch panels Optic cables 4

ENCLOSURES AND CABINETS Easy installation and efficient maintenance WORKSTATION The network at your hand Enclosures Zone distribution boxes Racks Installation supports Server enclosures RJ 45 sockets Wall mounted cabinets WI-FI WWW.LEGRAND.COM

FOLLOW US ALSO ON www.legrand.com www.youtube.com/legrand twitter.com/@legrand World Headquarters and International Department 87045 Limoges Cedex - France Tel.: + 33 (0) 5 55 06 87 87 Fax: + 33 (0) 5 55 06 74 55 EXB12057 - September 2012