Design of an Electrical Fire Monitoring and Warning System Based on Transducers

Similar documents
"Three Preventions" System Design Based On Single-Chip Microcomputer (SCM) Control Jiaxiong Wen

Design of Microwave Anti-theft Alarm Based on Microcontroller

Design of Mine Safety Detection Alarm Based on Single-chip Mingtao Ma

Construction of Wireless Fire Alarm System Based on ZigBee Technology

The Design of Temperature Control System for Vegetable Greenhouse

Design of Intelligent Humidity Sensing Watering System Based on MCU

for Precision Planter System Based on MSP430-CT171 Lianming Xia, Xiangyou Wang*, Duanyang Geng, Qingfeng Zhang

Design of Classroom Intelligent Lighting System Based on SCM. Jiale Zheng1, a

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Design of Humidity Monitoring System Based on Virtual Instrument

The design of the human body infrared thermometer

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

Study in Step by Step Electric Energy Meter Connection Detection Method

Design of an Infusion Rate Control System Based on Single Chip Microcomputer

A design of automatic boiler intelligent alert system based on the wireless AD hoc network

Design of Intelligent Home Alarm System Based on ARM

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Design of Intelligent Alarm System Based on GSM Network Shun Qing XU

Detection system for optic characteristics of automobile glasses

Gas Detection Instrument Based on Wireless Sensor Networks

Using the HT46R48 in a Gas Water Heater Application

Design of Cold Light Source System for Medical LED Endoscope

Design and Implementation of Wireless Gas Sensing Network for Preventing Industrial Calamity

The design of automatic remote monitoring system for the temperature and humidity based on GPRS Hui ZHANG 1, a, Honghua WANG 2,a

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

SAFETY PRE-ALARM MONITOR SYSTEM BASED ON GSM AND ARM

Design of Multi-Functional Alcohol Concentration Detecting System Zhang Chong, Zhang Yue

A Cost Effective Embedded Design for Security and Automation in Industries

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

LPG GAS LEAKAGE DETECTION, MONITORING AND CONTROL USING LabVIEW

IMR EX610. Portable Gas Detector. Operation Manual

Design of CO Concentration Detector Based on Infrared Absorption Method

A Forest Fire Warning Method Based on Fire Dangerous Rating Dan Wang 1, a, Lei Xu 1, b*, Yuanyuan Zhou 1, c, Zhifu Gao 1, d

E1000 Portable gas detector

Hazardous Gas Detection using ARDUINO

Design of Unmanned Monitoring and Automatic Monitoring System

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Temperature and Humidity Monitoring System for Embedded Computer

State Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, , China

Temperature and humidity controller system based on single chip microcomputer

Multi-sensor System For Indoor Environment Monitoring Zheng-yu Wanga, and Xiao-ru Zhangb

Design of Multi-Sensors Cooperation Control System for Intelligent Building

Electrical Energy department

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

Design of Electronic Control System for Robot Cleaning Machine Based on Profibus-DP. Wei GUAN

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Design and Development of Gas Leakage Monitoring System

Fire is No Accident Fire is No Accident It can be prevented.

Analysis of the Design of an HVAC System in a Public Building

International Journal of Scientific & Engineering Research Volume 9, Issue 2, February-2018 ISSN

A Research in the Tele-Working of the Intelligent Device for Anti-Disaster Security

Microcontroller based design for Tele-sensing and extinguishing fire

Android Controlled Fire Fighting Robot

EKL3 short circuit and earth fault indicator

CLOUD CONNECTED SMART GAS LEAKAGE DETECTION AND SAFETY PRECAUTION SYSTEM

DEVELOPMENT OF WIRELESS GAS SENSING SYSTEM FOR HOME SAFETY

2-wire Passive Intelligent Loop (LED) Display Meter

Industrial and home safety Management using GSM

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

Design of Gear Defect Detection System Based on Machine Vision

Web Site: Forums: forums.parallax.com Sales: Technical:

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Experimental Study of Dual Heater Slider Touchdown Detectability

GSM POWER ALARM SYSTEM

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Design and Implementation of Wireless Fire Fighting System

Engine Room Monitoring Alarm System Design and Implementation Xu Yuan, Ji Peng, Dai Yang, Ruan Shi-hao Abstract Key words:

A Design of IADSS with the Earthquake Detecting Function

A Design Method Based on Inherent Testability of Remote Control and Monitoring System for Marine Main Engine

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

DOCUMENTATION IPS640

DOCUMENTATION IPS640

2-wire Passive Intelligent Loop (LED) Display Meter

Implementation of Artificial Neural Fuzzy Inference System in a Real Time Fire Detection Mechanism

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

International Journal of Advancements in Research & Technology, Volume 2, Issue4, April ISSN

SCR100 User Manual. Version:1.1 Date:Dec 2009

Structure Design and Simulation of Intelligent Anti-blocking Sink

6367(Print), ISSN (Online) Volume (IJCET) 3, Issue 2, July- September (2012), IAEME

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

"Three Preventions" System Design Based On Single-Chip Microcomputer SCM Control Jiaxiong Wen

Design of Automatic Fire Alarm System in Workshop of Chemical Plant

Temperature Data Logging

Column swing gate turnstile CPW-321ASP

Laser Alarm System based on GSM Module Family

Research on Evaluation of Fire Detection Algorithms

Software-Aided Operation of Modern Industrial Leak Detectors

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

USER MANUAL FOR OPERATING SYSTEM

Wearable Carbon Monoxide Warning System Using Wireless Sensors

Installation Guide for inbiox60 Series Access Control Panel

Full-Scale Measurement and Numerical Analysis of Liquefied Petroleum Gas Water Heaters with Ventilation Factors in Balcony

Web Site: Forums: forums.parallax.com Sales: Technical:

号 PRODUCTORS CATALOGUE. ChengDu SAND Electronic Co. Ltd

An improved Algorithm of Generating Network Intrusion Detector Li Ma 1, a, Yan Chen 1, b

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

Transcription:

Design of an Electrical Fire Monitoring and Warning System Based on Transducers HE GuiXiong *1, PAN Deng 2, JIANG Li Min 1,MENG Jun Xia 1, CHEN Xiao Shuang 2 1 China Electric Power Research Institute, Haidian District, Beijing 100192, China 2 Beijing Jiaotong University, Haidian District, Beijing 100044, China *1 heguixiong@epri.sgcc.com.cn Abstract An electrical fire monitoring and warning system based on transducers is designed. The system consists of SCM, drain current detecting circuit, smog detecting circuit and temperature detecting circuit. Electric isolation and protection of the important components in general electrical environment are also designed. Experiments show that, when abnormal temperature, drain current, or smoke happens, the system can carry out data collection, aggregation, comparison, analysis and alarm, achieving the function of automatic monitoring and warning of electrical fire. Keywords Transducer; Electrical Fire; Drain Current; Monitoring; Automatic Warning Page Style The Introduction Electrical fire generally refers to those fire which are caused by electrical wiring, electrical equipment, appliances and power supply equipment failure to release heat (such as high temperature, electric arc and spark), and the energy release not under the failure condition (such as the hot surface of the electrothermal apparatus) spontaneous combustion in capable ignition or the fire caused by other fuel, it also including the fire caused by lightning and static electricity. From the point of origin, electrical fires mainly includes the following four aspects: first, the fire caused by the leakage; Second, the fire caused by short circuit; Third, the fire caused by overload; fourthly, the fire caused by the contact resistance is too large fires [1].In these aspects, the leakage fire appears the most. The fire caused by the leakage was due to a point on the transmission lines which was caused by man made or natural causes and led to a decline in insulating ability, it causes electric current flows between the conductor and the wire or between the conductor and the ground, local part will get hot and high temperature will happens when encounter greater resistance, it will also light the tinder nearby and causes a fire. Moreover, sparks in the leakage place will also become a major hidden danger of electrical fires [2]. Many fires are caused by short circuit which was caused by circuit aging, if could test the leakage current earlier,it could provide the staff enough time to escape from hazards and reduce casualties and even can completely avoid the happening of the fire. The traditional fire alarm only contains smoke sensor, its main function is to test the smoke or gas come from the burning of fuel[3,4,5]. The basic principle of work is using the smoke sensor to detect the concentration of the smoke or gas,connect the smog sensor to the amplifier circuit, the system will generate alarm signal when the signal is greater than the threshold. In order to prevent false alarm triggered by dust, usually,the system won t send out alarm signal until smoke concentration in air becomes very large, that is to say, the signal alarm is sent out when the ignition has been produced and the fire has spread already.so when it is told that there is a fire occurs, the easiest way to put out fire has been delayed. The fire spread around quickly, it is hard for the people to escape from the fire, besides, some of the fuel would produces a lot of poisonous gases at the same time,as long as people inhaled few of that will appear poisoning phenomenon, it increases the difficulty in escaping from the fire. Due to the deficiency of traditional fire alarm on the alarm time, it will lost the best time to escape, made heaviey loss of the personal safety and very bad social impact. This paper designed a electrical fire monitoring and early warning system,the system has a characteristics of monitoring leakage current,and it belongs to the early forecasting warning system. Through to monitor the leakage current in the line, can effectively confirm 205

International Journal of Automation and Power Engineering (IJAPE) Volume 2 Issue 4, May 2013 whether the line of leakage current is too large, and could early find the hidden trouble that could lead to a fire, the system can discover and eliminate hidden dangers before ignition occurs. Unlike traditional automatic fire alarm system, the traditional fire alarm system is to reduce the loss, however, the electric fire monitoring system of early warning could avoid the loss. The Overall Structure of the Monitoring and Early Warning System As single chip microcomputer monitoring and early warning system has completely controled the smoke detection circuit, leakage current detection circuit and temperature detection circuit already; implementation of smoke concentration, the value of the leakage current and temperature for testing, and introduced into SCM; single chip integrated the incoming data,and send out alarm signal. The overall structure of the system is shown in figure 1. detection, put these data into the comparison and analysis, to determine whether to send out alarm signal. The design selects the PIC16F877A single chip as the core, including the reset circuit, crystals circuit, voltage conversion circuit and the interface circuit which is connected with the emulator. Choose MC7805 as the voltage conversion circuit chip and matched with corresponding capacitance, so that we can convert the dc voltage from 12 v to 5 v for the use of SCM work. The internal ROM and RAM of the singlechip are chosen PIC16F877A The interface circuit which is connected to the emulator is to link the reset of the MCU,the power supply, and the pin of RB6 and RB7,put the pins into a column in other parts of the circuit board, the data line can be inserted on the row needle, the emulator could be connected to a circuit board through the data line.the design of the singlechip system is shown in figure 2. FIG.2 DESIGN OF SCM SYSTEM The Design of The Hardware of the Test System FIG.1 OVERALL STRUCTURE DIAGRAM OF SYSTEM The Design of The Hardware of a Monitoring and Early Warning System The Design of Hardware in SCM System Singlechip computer system is the core of the hardware part of the control module in the electrical fire monitoring system, its main function is to control the smoke detection circuits, the leakage current detection circuit and the working of the temperature detection circuit, collect the data that detected by the 1) The design of the Smoke Detection Circuit Smoke detection circuit selects the MQ 2 in the gas sensor. MQ 2 for the liquefied petroleum gas, propane, hydrogen and the carbon monoxide has a high sensitivity[6], the detection of natural gas and other combustible vapor has very good effect, in a wide range of concentrations,it also has a good sensitivity to combustible gases. MQ 2 has 6 pins, two of the pins connected to the heating circuit, the heating circuit adopts 5 v power supply, 31 Ω heat resistance, it will begin to work after heating for 30 seconds. The other four pins are responsible for 206 JOURNAL TITLE MONTH YEAR

taking out the signal, provisions of the working voltage of is 12 v. According to the resistance of the MQ 2 would fall as the concentration of carbon monoxide increases,so we can design a simple voltage comparison circuit. The op amp of the voltage comparison circuit selects the true differential input of the operational amplifier LM324 with four levels, it could work as low as 3.0 v or higher to 32 v power supply under the mode of single power supply, this design uses the working voltage of 12 v. 2) The Design of the Circuit Which is Using for Detecting Leakage Current The circuit which is using for detecting leakage current selects zero sequence current transformer. Zero sequence current transformer is a kind of current transformer in which there is single turn to wear heart type,and it commonly used in electric power protection equipment. The basic principle of its operation is based on the kirchhoffʹs current law: all the current flows into any node in the circuit add up to equal to zero. Under the normal working condition of the wiring and electrical equipment, the vector of each phase current and should be equal to zero, so the secondary side winding of the zero sequence current transformer with no signal output. When the ground fault occurs, the phase current vector and is not equals to zero, fault current makes the zero sequence current transformer toroidal core of the magnetic flux, secondary side of the zero sequence current transformer induced voltage signal, and it can drive other components for the next action [7]. Zero sequence current transformer is made of the permalloy, generally divided into two kinds, one kind is the permalloy chips which is thickness of 0.2 0.3 mm, inner diameter is 13 mm, folded after processing by 8 10 pieces would as thickness as3 mm thick rings.another kind forms by using permalloy strip winding, after forming ring with the first basic same, permeability can be 5T 6T. Select VG54123 chips as the zero sequence current transformer voltage generated in the testing and when the voltage is higher than threshold alarm signal will be produced. Owing to the voltage of VG54123 is 12 v while the voltage of MCU is 5 v, in order to put the signal of level change into the single chip and protect the microcomputer from being burned owing to the high voltage, to prevent the input signal from disturbing by other signals, put optocoupler into light leakage current detection circuit and single chip for electrical isolation. When the leakage protector working in the field of strong electric and magnetic environment, often suffer from all kinds of interference,and the interference will affect the working of leakage protector in various ways. If leakage current reaches or exceeds the threshold without the police, can cause a serious fire hazard, followed by the cause of ignition and the fire spread quickly, finally cause a fire. The fire could be avoided, but happened for the cause of the strong interference of the leakage current protector did not achieve its proper role. If leakage current does not meet the threshold for the interference lead to wrong alarm signal, line power supply is disconnected,cause the on duty staff mistake leakage current is greater than the threshold and repeated check on leakage current, after closing line again, it takes a lot of manpower and material resources. If multiple cause of alarm signal, the alarm will be artificially outage, it increased the hidden danger of fire, when leakage current really is greater than the threshold,the fire alarm will stop and it would cause a significant security hidden danger, therefore, leakage alarm circuit with strong anti interference performance is of great necessity. The scale of the integral capacitor which is linked with foot 4, will directly influence the anti interference performance of leakage current alarm circuit, at a time VG54123 link with integral capacitor constantly for about 5 ms, it is of highly advantageous to suppress the sharp narrow interference pulse. Although the inhibition ability as the capacitance increase of increased, but in the choice of capacitance, the action time and triggering sensitivity should also be taken into consideration, usually,select the capacitor from 0.033 uf to 0.069 uf, here we choose capacitance of 0.047 uf, and select the capacitance of small loss under normal working state. A 0.047 uf capacitor should be installed between ground 1 and the foot to enhance anti jamming ability and the foot 6 feet 7 foot 1 also Due to the VG54123 have the function of the lock,once the lock circuit enter in locked state,it would be unable for device to liberate, unless the leakage switch received the leakage signal and the power will be immediately cut off, the locking circuit will automatically release as well. 207

International Journal of Automation and Power Engineering (IJAPE) Volume 2 Issue 4, May 2013 FIG.3 PCB DESIGN OF DETECTING SYSTEM 3) The Design of Temperature Detection Circuit Choose chip DS1820 as the components of the temperature detection circuit. The oscillation of frequency crystal vibration in the DS1820 which is of low temperature coefficient receives little influence by temperature [8,9], and used to generate pulse signal with fixed frequency sent to the down counter A, but the oscillation frequency of the high temperature coefficient of crystals changes with the temperature change is obvious,put the signal gotten above as the input of the down counter B. In addition, DS1820 contains a counter, when the counter opens, DS1820 count the pulse which is produced by low temperature coefficient of oscillator,after the above the process of temperature measurement is finished. Open time of the counter is determined by the high temperature coefficient of oscillator counter. Every time before the measurement, put the count which is corresponds to 55 into the down counter register A and temperature register, the down counter register A and temperature register will be preset at the base value which is corresponds to 55. Down counter A for the pulse signal which is produced by the low temperature coefficient of crystal subtraction counting, when the preset value of down counter A reduced to 0, the values of temperature register will plus 1, the preset number of down counter 1 will be loaded again, down counter A start again to count the pulse signal that produced by the low temperature coefficient of crystals, perform this loop until down counter B counts to zero,then stop accumulating the values in temperature register, at this time the temperature in the register values is the measured temperature value The slope accumulator in DS1820 can be used for compensation and correction of temperature measurement in the process of nonlinear [10], and its output is used to fix the preset value of the down counter, as long as the counter is not closed, just repeat the above process until the temperature values in temperature registers is as high as the measured temperature value. Detection systems which named PCB was designed as shown in figure 3. FIG.4 FLOW CHART OF MAIN ROUTINE 208 JOURNAL TITLE MONTH YEAR

The Software Design of Monitoring and Early Warning System Loop testing through RB3 and RA0, to confirm whether the smoke concentration exceed the rated value, leakage current exceed the rated value, by comparing temperature measured from the DS1820 temperature and temperature thresholds can be used to confirmed whether the environment temperature is higher than the temperature threshold. When there is a smoke concentration exceed the rated value, the leakage current exceeds the rated value,besides the environment temperature also exceeds rated value,the system will generate alarm respectively.the working process of the main program is shown in figure 4. Length place is restricted, so the subroutine design process not described here. Conclusions On the basis of the traditional fire alarm system,in view of the current frequent electrical fire situation, so designed the electrical fire automatic monitoring and early warning system that the system refers to electric fire characteristic,which was used the combination of sensor and MCU.The system also applies to the fire which isn t caused by the electrical. The design of the hardware and software in the system has be carried on thorough discussion, the electrical fire can be early warned by detecting leakage current, assisted with smoke and temperature detection circuit, can also be able to monitor the electrical fire. The experimental results show that the collected data and actual data are consistent, stable operation, low power consumption, low cost,so the experiment have certain practical and promotional value. REFERENCES Chen Libing,Fan Yujin,Dai Jie. Design of Temperature Acquisition System Based on AT89S52 Single chip. Machinery & Electronic, 2011(2). Fu Qiang. The causes and prevention of electrical fire. Journal of theory, 2012 (4) : 33 34. Liu Qingping.,Research of Fire Alarm System. Science Mosaic, 2011(7). Wang Jin, Chen Xia, Rui Guohon. Asynchronous motor fault protection application and research in coal winning machine. Industrial automation, 2010 (7) : 79 82. Wei Jungan,Zhan Chao,Tian Jianxue. Application in the Temperature Measure System. Instrumentation Technology, 2008(8). Wu Hongtai. Seamless rail temperature automatic monitoring system based on single chip microcomputer research Beijing: Beijing jiaotong university, 2008. Ye Lina. My opinion about the management electrical device in coal mine. Strait science, 2010(9). Yu Hongbo,, LI Hui., Design and Implementation of Portable GSM Wireless Gas Warning System..Control and Instruments in Chemical Industry, 2011,38(11). Zhang He. Multichannel Wireless Fire Alarm System. Modern Electronics Technique, 2007,30(5). Zhao Hailan Zhao Xiangwei. The principle and application of the intelligent temperature sensor DS18B20. Modern electronic technology, 2003 (14) : 32 34. He Gui xiong, M, 1984.12, mid level engineer, Master of the power system automation, worked for the China Electric Power Research Institute, is principally engaged in energy efficiency evaluation of energy efficiency and demand side management. Pan Deng,M,1989.4,assistant engineer,master of the power system automation, studied in Institute of electrical engineering of Beijing Jiaotong University,and is principally engaged in energy efficiency evaluation of energy efficiency and demand side management. Jiang Li min, M, 1978.8, mid level engineer Master of the power system automation, worked for the China Electric Power Research Institute, is principally engaged in energy efficiency evaluation of energy efficiency. 209