MODEL: 47NLVT. Digital Panel Meters 47NL Series. POWER INPUT DC Power R: 24 V DC

Similar documents
MODEL: 47NLDYT. [2] OPTIONS blank: none /Q: With options (specify the specification) Digital Panel Meters 47NL Series

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

Digital Panel Meters 47 Series. DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL

SHIMADEN DIGITAL INDICATORS

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Process Alarm Module RTA 421

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

TEMPERATURE CONTROL MODULE MODEL R3-TC2

Temperature Controllers

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

Digital Heater Element Burnout Detector K8AC-H

Model Number Structure

Universal controller for panel mounting Models CS6S, CS6H, CS6L

DIGITAL PANEL METER N20 type

Gas cylinder scale Model GCS-1

General Specifications

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

DIGITAL PANEL METER N20Z TYPE

MICROJET RECORDER (24-CHANNEL 180mm)

GCS-300 No.GCS31E

E5CN/E5CN-U (48 x 48 mm)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

MICRO CONTROLLER S Z SERIES

02/11/2015

DIGITAL METERS Large Display Temperature Meters Instruction Manual

02/11/2015

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

ISOLATOR SGI SGIW INSTRUCTION MANUAL

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

WIO 200B and WIOI200B Water in oil sensor

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

COMMANDER 150. User Guide Universal Process Indicator A1

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

PMD-MXT -XX -XXX. Ordering Example. Model Input Channels Input Type. THC Thermocouple channels channels channels RTD RTD

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

DIGITAL INDICATOR DI25

Speed and Frequency Seite 1 von 7

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Installation Manual Tracker 221

/8 DIN Level Indicator

3500/61E & 3500/67E Temperature Monitor

Instruction manual Micro-computer based digital indicating controller

FCCP 200: Fume-cupboard indicator and monitor

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

WIO200 Water In Oil measuring instrument

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

Premier Series Monitor

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

INSTRUCTION MANUAL Micro-computer based digital indicating controller

FAST RESPONSE TEMPERATURE SENSORS 42.11a

QFM21... Duct sensors. Symaro. for relative humidity and temperature

DIGITAL INDICATOR JIR-301-M

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

4TEMPERATURE CONTROLLER

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

TEMPERATURE CONTROLLER

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

KH SERIES (PEN-WRITING SYSTEM)

JW SERIES. Three Phase Thyristor Regulator PSE-351

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

for relative humidity and temperature

AutomationDirect. PC35 Configuration Sheet

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

Flameproof Type Light Curtain Type 4

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Transcription:

Digital Panel Meters 47N Series DC INPUT DIGITA PANE METER (4½ digit, ED display type, with terminal block) Functions & Features 4 ½ digit DC input digital panel meter Moving average function to suppress the display flickering Scaling, forced zero, low-end cutout Max. and Min. value display Photo MOSFET relay alarm output Dedicated terminal block for I/O 96.0 (3.78) POWER INPUT DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [3] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-9562) 48.0 (1.89) P Zro Spn D/P Tch Fnc Min Max Max/Min Alarm/ Scale/ Shift Up * Panel thickness not included. 48.5 (1.91)* mm (inch) MODE: 47NVT-[1][2]-R[3] ORDERING INFORMATION Code number: 47NVT-[1][2]-R[3] Specify a code from below for each [1] through [3]. (e.g. 47NVT-4WB-R/Q) Specify the specification for option code /Q (e.g. /SET) [1] INPUT Current A: 4 20 ma DC (Input resistance 10 Ω) D: 0 20 ma DC (Input resistance 10 Ω) Voltage 4: 0 10 V DC (Input resistance 1 MΩ min.) 5: 0 5 V DC (Input resistance 1 MΩ min.) 6: 1 5 V DC (Input resistance 1 MΩ min.) 4W: -10 +10 V DC (Input resistance 1 MΩ min.) 5W: -5 +5 V DC (Input resistance 1 MΩ min.) [2] DISPAY COOR R: Red YR: Orange G: Green B: Blue W: White GENERA SPECIFICATIONS Construction: Panel mount type Degree of protection: IP66; Applicable to the front of the panel meter mounted according to the specified panel cutout. Connection: M3 screw terminals (torque 0.6 N m) Solderless terminal: Refer to the drawing at the end of the section. Recommended manufacturer: Japan Solderless Terminal MFG.Co.td, Nichifu Co.,ltd Applicable wire size: 0.25 to 1.65 mm 2 (AWG 22 to 16) Screw terminal: Nickel-plated steel ousing material: Flame-resistant resin (gray) Isolation: Input to alarm output to power Setting: (Front button) Scaled range Alarm setpoint ysteresis (deadband) Moving average Others (Refer to the operating manual for details) Averaging: None or moving average ockout setting: Prohibiting certain operations; protecting settings Recommended solderless terminal 6 (.24) max 3.3 (.13) max mm (inch) DISPAY Display: 16 mm (.63) high, 4 ½ digits, 7-segment ED Display range: -19999 to 19999 Decimal point position: 10 1, 10 2, 10 3, 10 4 or none Zero indication: igher-digit zeros are suppressed. 47NVT SPECIFICATIONS ES-9562 Rev.4 Page 1/5

Over-range indication: -19999 or 19999 blinking for display values out of the display range. S.ERR and Min or Max blinking when the input signal is out of the usable range. Alarm status indication indicator: Green turns on when the alarm is tripped. indicator: Red turns on when the alarm is tripped. P indicator: Amber turns on when none of the other alarms is tripped. Only P turns on when no-alarm is selected with alarm setpoint. Function indicators: Zro, Spn, D/P, Tch, Fnc, Min, Max Display mode status and operation status, amber ON or blink Engineering unit indication: Sticker label attached DC, AC, mv, V, kv, μa, ma, A, ka, mw, W, kw, var, kvar, Mvar, VA, z, Ω, kω, MΩ, cm, mm, m, m/sec, mm/min, cm/min, m/min, m/h, m/s 2, inch, l, l/s, l/min, l/h, m 3, m 3 /sec, m 3 /min, m 3 /h, Nm 3 /h, N m, N/m 2, g, kg, kg/h, N, kn, Pa, kpa, MPa, t, t/h,, F, %R, J, kj, MJ, rpm, sec, min, p, %, ppm, etc. Weight: 120 g (0.26 lb) PERFORMANCE Accuracy Display: ±0.1 % ± 1 digit Temp. coefficient: ±0.015 %/ C (±0.008 %/ F) Response time: 0.5 sec. (alarm output: 0 100 % at 90 % setpoint) ine voltage effect: ±0.1 % over voltage range Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (input to alarm output to power to ground) STANDARDS & APPROVAS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoS Directive EN 50581 INPUT SPECIFICATIONS A: Conformance range 4.00-20.00 ma DC (Usable Range: 2.40-21.60 ma DC) D: Conformance range 0.00-20.00 ma DC (Usable Range: -2.00 - +22.00 ma DC) 4: Conformance range 0.000-10.000 V DC (Usable Range: -1.000 - +11.000 V DC) 5: Conformance range 0.000-5.000 V DC (Usable Range: -0.500 - +5.500 V DC) 6: Conformance range 1.000-5.000 V DC (Usable Range: 0.600-5.400 V DC) 4W: Conformance range -10.000 - +10.000 V DC (Usable Range: -12.000 - +12.000 V DC) 5W: Conformance range -5.000 - +5.000 V DC (Usable Range: -6.000 - +6.000 V DC) OUTPUT SPECIFICATIONS Alarm Output: Photo MOSFET Relay Rating: 26.4 V DC @ 100 ma (resistive load) ON resistance: 5 Ω INSTAATION Power consumption DC: 0.7 W max. Operating temperature: -10 to +55 C (14 to 131 F) Operating humidity: 10 to 90 %R (non-condensing) Mounting: Screw mounting 47NVT SPECIFICATIONS ES-9562 Rev.4 Page 2/5

EXTERNA VIEW (1) Main Display (2) Alarm Indicators P (3) Function Indicators Zro Spn D/P Tch Fnc Min Max Max/Min Alarm/ Scale/ Shift Up (4) Max/Min Button (5) Alarm/ Button (8) Up Button (7) Shift Button (6) Scale/ Button COMPONENT IDENTIFICATION No. COMPONENT FUNCTION (1) Main display Indicates present values, setting values and status of the unit. (2) Alarm indicators Indicates the comparison result between alarm setting values and present values. (3) Function indicators Indicates the status in each setting mode. (4) Max/Min button Used to switch the main display to show the present values, maximum values or minimum values. (5) Alarm/ button Used to check the alarm setpoints, to move on to the alarm and other setting modes; or to shift through setting items in each setting mode. (6) Scale/ button Used to move on to the scaling and other setting modes; or to shift through setting items in each setting mode. (7) Shift button Used to move on to the setting standby status of each setting mode or to shift through display digits in each setting item. (8) Up button Used to change setting values, to execute/cancel Forced Zero or to select setting values. Note: Refer to the operating manual for details on each function. EXTERNA DIMENSIONS & TERMINA ASSIGNMENTS unit: mm (inch) BODY FRONT VIEW SIDE VIEW 96.0(3.78) 20.0 (.79) Watertight packing arness 48.0 (1.89) approx. 30 (1.18) REAR VIEW 4-M4 SCREW 8.0 (.31) deep 1 2 3 4 5 6 7 8 47NVT SPECIFICATIONS ES-9562 Rev.4 Page 3/5

TERMINA BOCK FRONT VIEW 96.0 (3.78) 6.4 (.25) 2 4.5 (.18) dia. 34 (1.34) 1 2 3 4 5 6 7 8 9 10 REAR VIEW SIDE VIEW 8 (.31) Max. 20.5 (.81) 2 (.08) MOUNTING REQUIREMENTS unit: mm (inch) Single Mounting Clustered Mounting 17 (.67) 42.25 (1.66) 42.25 (1.66) 4-4.5 (.18) dia. min. 75 (2.95) 20.5 (.81) 30.5 (1.20) dia. min.120 (4.72) Panel thickness: 1.0 to 3.2 mm Panel thickness: 1.0 to 3.2 mm SCEMATIC CIRCUITRY & CONNECTION DIAGRAM INPUT + 1 2 3 4 5 A/D Converter Display / Setting Digital Computation Ry Ry 6 7 8 9 10 OUTPUT OUTPUT COM + POWER 47NVT SPECIFICATIONS ES-9562 Rev.4 Page 4/5

Specifications are subject to change without notice. 47NVT SPECIFICATIONS ES-9562 Rev.4 Page 5/5