Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Similar documents
K*, R* Ventilation grilles

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Technical data lumina PM

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Passive chilled beams

Technical data lumina MS4

Air distribution for clean rooms. Clever and flexible.

TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Pre-programmed room controller with communication

Danfoss gas detection unit Type GD Heavy Duty

Type RM-O-3-D. Duct smoke detector used to prevent smoke from spreading through the ducts of ventilation and air conditioning systems

Duct Air Quality Sensors

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Units for suspended ceilings

02/11/2015

Decentralised ventilation units

Compact. Efficient. TROX.

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

ModBus DE-1 INSTALLATION AND USER MANUAL

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

1. Product description

02/11/2015

DMFPM-2R MULTIFUNCTIONAL

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Danfoss gas detection units

Installation Guide. Ceiling PIR Detector (311) Features and Connections

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

for relative humidity and temperature

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

QPM21 Series Duct CO 2 and Air Quality Sensors

Dew point set DS 400

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

NEW RANGE OF WARM AIR CURTAINS

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Passive infrared ceiling sensor

Dual certification! Air handling units for potentially explosive atmospheres

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Decentralised ventilation units

SIMRAD GD10PE IR GAS DETECTOR

Dräger Polytron 8720 IR Detection of carbon dioxide

XC10 Extinguishing control panels

Ceiling diffusers. Type DLQL

Units for suspended cei lings

Chilled Ceiling Elements

OEM Alpha Thermostat direct Analog

Seamlessly integrated. The new sensor range from Belimo.

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Dräger Polytron 5720 IR Toxic Gas Detection

DESCRIPTION MODEL 1205/1205HA NOTE

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Compact. Efficient. TROX.

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Decentralised ventilation unit

Decentralised ventilation unit

Recalibrate the way you look at gas detection

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dublin airport - Dublin, Ireland

Increased safety and reducing energy consumption with the motion control RPI 01

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Blower-YEFB-020-3R-1maxVel

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Decentralised ventilation

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

SEQUENCE OF OPERATIONS

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

ENERGY SAVING SEIBU GIKEN DST

Dräger Polytron 5700 IR Detection of flammable gases and vapours

DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS.

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Ionisation single-tube smoke detector for duct mounting

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Line Smoke Detector LRMX

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

APPLICATION DATA SHEET

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Danfoss gas detection units

Duct Temperature Sensors

Detector switch - Dual Tech

TER Active Room Temperature Sensor (Controller),

Universal fault annunciator for panel mounting

Transcription:

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS SENSORS FOR X-AIRCONTROL ZONE MODULES AND OTHER EQUIPMENT Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL Combined temperature and humidity sensor Dew point monitor Air quality sensor Motion detector Splitter

APPLICATION Application Type X-SENS sensors for use with X-AIRCONTROL and other control systems Can be connected to X-AIR-ZMO zone modules and X-AIR-ZMAS master modules Duct temperature sensor for supply and extract air Combined temperature and humidity sensor for extract air ducts Air quality sensor used as a duct sensor for measuring the concentration of volatile organic compounds (VOC) Air quality sensor for measuring the CO content in the room air and, when used as a room sensor, for measuring the humidity Dew point monitor for chilled ceilings etc. Motion detector (occupancy) Four-way splitter for the connection of four sensors or control panels (Modbus) 2 DESCRIPTION Variants TEMP-RH-EXH: Combined temperature and humidity sensor for extract air TEMP-PT1000: Duct temperature sensor (PT1000) VOC: Air quality sensor (VOC) CO2-RH: Combined CO and humidity sensor 2 DEWPT: Dew point monitor PIR-SM: 180 motion detector PIR-FM: 360 motion detector SPLITTER: Four-way splitter for the connection of four sensors or control panels (Modbus) Maintenance Maintenance-free as construction and materials are not subject to wear Checking and cleaning is recommended, in particular if the device is used in a room or in an extract air duct Regular cleaning from dust is recommended TECHNICAL INFORMATION

Function, Technical data, Specification text, Order code FUNCTION Combined temperature and humidity sensor Functional description X-SENS-TEMP-RH-EXH sensors are control components for integration with control systems such as X-AIRCONTROL. The sensor consists of two sensor heads for measuring temperature and relative humidity. The duct sensor variant is intended for use in circular or rectangular extract air ducts. Measuring ranges are 40 to 120 C and 0 to 100% relative humidity. A Modbus RTU data interface is used to transmit measured values to the control system. A plug-in connection cable with an RJ12 plug simplifies installation. The zone module automatically recognises the sensor (plug and play). Duct temperature sensor (PT1000) Functional description X-SENS-TEMP-PT1000 temperature sensors are control components for integration with control systems such as X- AIRCONTROL. The temperature sensor is a PT1000 sensor. The duct sensor variant is intended for use in circular or rectangular supply air ducts, or preferably in extract air ducts, as an alternative to a room temperature sensor. Measuring range: 40 to 85 C. The zone module automatically recognises the temperature sensor (plug and play). Air quality sensor (VOC) Functional description X-SENS-VOC air quality sensors are control components for integration with control systems such as X-AIRCONTROL. The air quality sensor measures the concentration of volatile organic compounds such as alcohols, aldehydes, ketones, esters, terpenes, aromatic compounds, and alkenes. The duct sensor variant is intended for use in circular or rectangular extract air ducts. Measuring range: 450 to 2000 ppm.

A Modbus RTU data interface is used to transmit measured values to the control system. A plug-in connection cable with an RJ12 plug simplifies installation. The zone module automatically recognises the sensor (plug and play). Combined CO and humidity sensor 2 Functional description X-SENS-CO2-RH sensors are control components for integration with control systems such as X-AIRCONTROL. The sensor consists of two sensor heads for measuring CO concentration and relative humidity. The room sensor variant is intended for use in a room. The precision of CO concentration measurements is maintained by cyclical self calibration. 2 2 Measuring ranges are 0 to 2000 ppm and 0 to 100% relative humidity. Measured values are transmitted to the control system via 0 10 V DC analogue signals. The zone module automatically recognises the sensor (plug and play). 180 motion detector Functional description X-SENS-PIR-SM motion detectors are control components for integration with control systems such as X-AIRCONTROL. The motion detector includes a PIR sensor (passive infrared) for detectiong people in a room, i.e. occupancy. The flush mounted variant for mounting on a wall has an operational range of 180. The condition (i.e. if the room is occupied or not) is transmitted to the control system via a volt-free digital output. 360 motion detector Functional description X-SENS-PIR-FM motion detectors are control components for integration with control systems such as X-AIRCONTROL. The motion detector includes a PIR sensor (passive infrared) for detectiong people in a room, i.e. occupancy. The surface mounted variant for mounting on a ceiling has an operational range of 360. The condition (i.e. if the room is occupied or not) is transmitted to the control system via a volt-free digital output. Dew point monitor Functional description X-SENS-DEWPT dew point monitors are control components for integration with control systems such as X-

AIRCONTROL. The dew point monitor contains a humidity sensor for measuring the relative humidity near the dew point (100% rh). The goal is to ensure that the dew point is not reached, i.e. that condensation is avoided. The condition is transmitted to the control system via a volt-free digital output. Four-way splitter Functional description X-SENS-SPLITTER four-way splitters are used to connect up to three sensors and actuators to an interface, e.g. to an interface of a zone module within X-AIRCONTROL. The four-way splitter can also serve as an adapter to connect air quality and temperature sensors to terminals in case the connection cables have bare wire ends. The actual connection to the zone modules is done with RJ12 plugs. X-AIRCONTROL zone 1 Zone module

2 Temperature sensor 3 Air quality sensor 4 Motion detector 5 Humidity sensor 6 Control panel 7 Cooling, e.g. with an active chilled beam 8 Heating, e.g. with a heating coil 9 Volume flow control TECHNICAL DATA X-SENS-TEMP-RH-EXH

Supply voltage 24 V DC ± 25%, from the zone module Power rating 0.22 W Temperature measurement Measuring range 40 to 120 C Measurement error 0.25 K (15 40 C) Humidity measurement Measuring range 0 100% rh Measurement error <5% rh, <2% rh (10 90% rh) Long term drift 0.5% rh per year Installed length 50 250 mm Operating temperature 20 to 50 C Max. humidity 5 95% rh, no condensation IEC protection class III (protective extra-low voltage) Protection level IP 54 (sensor head IP 32) Connecting cable 7 m, with RJ12 plug Installation location Circular and rectangular ducts Weight 250 g X-SENS-TEMP-PT1000

Sensor PT1000 Resistance 1000 Ω at 0 C Measurement error 0.5 K ( 40 to 15 C) 0.725 K (40 to 85 C) Installed length 116 mm Operating temperature 40 to 100 C Max. humidity 5 95% rh, no condensation IEC protection class III (protective extra-low voltage) Protection level IP 32 Connecting cable 4 m, bare wire ends Installation location Circular and rectangular ducts Weight 250 g X-SENS-VOC

Supply voltage 24 V DC ± 25%, from the zone module Power rating 0.46 W Measuring range 450 2000 ppm Measurement error <150 ppm Start-up time 15 min Response time 5 min Installed length 65 105 mm Operating temperature 0 50 C Max. humidity 5 95% rh, no condensation IEC protection class III (protective extra-low voltage) Protection level IP 54 (sensor head IP 20) Connecting cable 7 m, with RJ12 plug Installation location Circular and rectangular ducts Weight 175 g X-SENS-CO2-RH

Supply voltage 24 V AC/DC, from the zone module Power rating 1.2 W CO measurement 2 Measuring range 0 2000 ppm Measurement error ±30 ppm Start-up time 10 min Humidity measurement Measuring range 0 100% rh Measurement error 3% rh (20 80% rh) Long term drift <10% rh per year Operating temperature 0 50 C Max. humidity 5 95% rh, no condensation IEC protection class III (protective extra-low voltage) Protection level IP 30 Colour RAL 9010, pure white Installation location Wall installation Dimensions 80 105 23.5 mm Weight 69 g X-SENS-PIR-SM

Supply voltage 24 V AC/DC ± 10%, from the zone module Sensor PIR (passive infrared) Operational range 180 Detection range 8 m; 4 m with people sitting Installation, distance from floor 1.1 to 2.2 m (4 m max.) Operating temperature 25 to 55 C Max. humidity 5 95% rh, no condensation IEC protection class III (protective extra-low voltage) Protection level IP 30 Connection Screw terminals Colour RAL 9010, pure white Installation location Wall installation on a Ø60 mm junction box Dimensions 88 88 64 mm Weight 98 g X-SENS-PIR-FM

Supply voltage 24 V AC/DC ± 10%, from the zone module Sensor PIR (passive infrared) Operational range 360 Detection range 8 m; 4 m with people sitting Installation, distance from floor 2.5 to 3.0 m (10 m max.) Operating temperature 25 to 55 C Max. humidity 5 95% rh, no condensation IEC protection class III (protective extra-low voltage) Protection level IP 30 Connection Screw terminals Colour RAL 9010, pure white Installation location Wall installation Dimensions 98 mm, 48 mm protruding beyond the surface Weight 104 g X-SENS-DEWPT

Supply voltage 24 V AC/DC ± 20%, from the zone module Power rating 1.0 VA Switching point 92 ±4% rh at 25 C Hysteresis 5% rh Response time 3 minutes max. Exposure to condensation 30 minutes max. Switch output Volt-free contact, 230 V AC max., 1 A max. Operating temperature 0 50 C IEC protection class III (protective extra-low voltage) Protection level IP 30 Installation location Casing suitable for installation on a wall or ceiling, sensor casing suitable for chilled surfaces Weight 85 g X-SENS-SPLITTER

Operating temperature 0 to 50 C IEC protection class III (protective extra-low voltage) Protection level IP 20 Connection 4 RJ12 sockets and 8 spring-loaded terminals, 1.5 mm² Installation location Switch cabinet, wall or ceiling Fixing On a mounting rail Dimensions 46 78 45 Weight 60 g SPECIFICATION TEXT Combined temperature and humidity sensor Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL Combined temperature and humidity sensor for rectangular and circular extract air ducts. Ready-to-operate sensor which consists of a casing with flange, a protective tube with two sensor heads, and a connecting cable with RJ12 plug. Modbus RTU data interface for the transmission of measured values to the control system. The zone module automatically recognises the sensor (plug and play). Plastic casing Technical data Supply voltage: 24 V DC ± 25%, from the zone module Power rating: 0.22 VA Temperature measurement

Measuring range: 40 to 120 C Measurement error: 0.25 K (15 to 40 C) Humidity measurement Measuring range: 0 to 100% rh Measurement error: <5 % rh, <2 % rh (10 to 90% rh) Long term drift: 0.5% rh per year Installed length: 50 to 250 mm Operating temperature: 20 to 50 C Max. humidity: 5 to 95% rh, no condensation IEC protection class: III (protective extra-low voltage) Protection level: IP 54 (sensor head IP 32) Connecting cable: 7 m, with RJ12 plug Installation location: Circular and rectangular ducts Duct temperature sensor (PT1000) Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL Temperature sensor for rectangular and circular extract air ducts. Ready-to-operate sensor which consists of a protective tube with flange, a sensor head and a connecting cable. The zone module automatically recognises the temperature sensor (plug and play). Protective tube made of plastic Technical data Supply voltage from the zone module Sensor: PT1000 Resistance: 1000 Ω at 0 C Measurement error: 0.5 K ( 40 to 15 C), 0.725 K (40 to 85 C) Installed length: 116 mm Operating temperature: 40 to 100 C Max. humidity: 5 to 95% rh, no condensation

IEC protection class: III (protective extra-low voltage) Protection level: IP 32 Connecting cable: 4 m, bare wire ends Installation location: Circular and rectangular ducts Air quality sensor (VOC) Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL Sensor for measuring the concentration of volatile organic compounds in rectangular and circular supply or extract air ducts. Ready-to-operate sensor which consists of a protective tube with flange, a sensor head, and a connecting cable with RJ12 plug. Modbus RTU data interface for the transmission of measured values to the control system. The zone module automatically recognises the temperature sensor (plug and play). Plastic casing Technical data Supply voltage: 24 V DC ± 25%, from the zone module Power rating: 0.46 VA Measuring range: 450 to 2000 ppm Measurement error: <150 ppm Start-up time: 15 minutes Response time: 5 minutes Installed length: 65 to 105 mm Operating temperature: 0 to 50 C Max. humidity: 5 95% rh, no condensation IEC protection class: III (protective extra-low voltage) Protection level: IP 54 (sensor head IP 20) Connecting cable: 7 m, with RJ12 plug Installation location: Circular and rectangular ducts Combined CO and humidity sensor 2 Components for the measurement and recording of various quantities and conditions in systems for single room control and

centralised control such as X-AIRCONTROL Sensor for measuring the CO concentration and humidity in rooms. 2 Ready-to-operate sensor which consists of a casing with two sensor heads and connection terminals. The zone module automatically recognises the sensor (plug and play). Plastic casing Technical data Supply voltage: 24 V AC/DC, from the zone module Power rating: 1.2 VA CO measurement 2 Measuring range: 0 to 2000 ppm Measurement error: 30 ppm Start-up time: 10 minutes Humidity measurement Measuring range: 0 to 100% rh Measurement error: 3% rh (20 to 80% rh) Long term drift: <10% rh per year Operating temperature: 0 to 50 C Max. humidity: 5 to 95% rh, no condensation IEC protection class: III (protective extra-low voltage) Protection level: IP 30 Colour: RAL 9010, pure white Installation location: Wall Dimensions: 80 105 23.5 mm 180 motion detector Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL

Motion detector (occupancy). Ready-to-operate detector which consists of a casing and a PIR sensor (passive infrared). Switch output (volt-free contact) for the transmission of the detected condition (occupied or not occupied) to the control system. White plastic casing Technical data Supply voltage: 24 V AC/DC ± 10%, from the zone module Sensor: PIR (passive infrared) Operational range: 180 Detection range: 8 m; 4 m with people sitting Installation location: Preferably 1.1 to 2.2 m above the floor (4 m max.) Operating temperature: 25 to 55 C Max. humidity: 5 to 95% rh, no condensation IEC protection class: III (protective extra-low voltage) Protection level: IP 30 Connection: Screw terminals Colour: RAL 9010, pure white Installation location: Wall installation on a Ø60 mm junction box Dimensions: 88 88 64 mm 360 motion detector Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL Motion detector (occupancy). Ready-to-operate detector which consists of a casing and a PIR sensor (passive infrared). Switch output (volt-free contact) for the transmission of the detected condition (occupied or not occupied) to the control system. White plastic casing Technical data

Supply voltage: 24 V AC/DC ± 10%, from the zone module Sensor: PIR (passive infrared) Operational range: 360 Detection range: 8 m; 4 m with people sitting Installation location: Preferably 2.5 to 3.0 m above the floor (10 m max.) Operating temperature: 25 to 55 C Max. humidity: 5 to 95% rh, no condensation IEC protection class: III (protective extra-low voltage) Protection level: IP 30 Connection: Screw terminals Colour: RAL 9010, pure white Installation location: Wall Dimensions: 98 mm, 48 mm protruding beyond the surface Dew point monitor Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL Sensor for monitoring the dew point on chilled surfaces. Ready-to-operate sensor which consists of a casing and a sensor head in a separate casing. Switch output (volt-free contact) for the transmission of the detected condition (occupied or not occupied) to the control system. Plastic casing Technical data Supply voltage: 24 V AC/DC ± 20%, from the zone module Power rating: 1.0 VA Switching point: 92 ± 4% rh at 25 C Hysteresis: 5% rh Response time: 3 minutes max. Exposure to condensation: 30 minutes max. Switch output: Volt-free, 230 V AC max. 1 A max. Installation location: Casing suitable for installation on a wall or ceiling, sensor casing suitable for chilled surfaces Four-way splitter

Components for the measurement and recording of various quantities and conditions in systems for single room control and centralised control such as X-AIRCONTROL Four-way splitter for the connection of four sensors or control panels (Modbus). The four-way splitter can also serve as an adapter to connect air quality and temperature sensors to terminals in case the connection cables have bare wire ends. The actual connection to the zone modules is done with RJ12 plugs. Plastic casing Technical data Operating temperature: 0 to 50 C IEC protection class: III (protective extra-low voltage) Protection level: IP 20 Connection: 4 RJ12 sockets and 8 spring-loaded terminals, 1.5 mm² Installation location: Switch cabinet, wall or ceiling Fixing: On a mounting rail Dimensions: 46 78 45 mm

ORDER CODE Type Variant X-SENS Sensor TEMP-RH-EXH Combined temperature and humidity sensor for extract air TEMP-PT1000 Duct temperature sensor (PT1000) VOC CO2-RH DEWPT PIR-SM PIR-FM Air quality sensor (VOC) Combined CO 2 and humidity sensor Dew point monitor 180 motion detector 360 motion detector SPLITTER Four-way splitter for the connection of four sensors or control panels (Modbus) Temperature sensor, Air quality sensor, Motion detector, Other TEMPERATURE SENSOR X-SENS-TEMP-RH-EXH Application

X-SENS-TEMP-RH-EXH temperature and humidity sensor to be used for X-AIRCONTROL or other systems; can be connected to X-AIR-ZMO zone modules Temperature and relative humidity measurement Sensor for rectangular and circular extract air ducts Measuring ranges 40 to 120 C and 0 to 100 % rh Plug-in connection for supply voltage and for communication with the zone module The zone module automatically recognises the sensor (plug and play) Parts and characteristics Casing with flange to be screw-fixed to the installation surface Protective tube with sensor heads, for installation into a duct Plug-in cable Modbus RTU data interface Plastic casing X-SENS-TEMP-PT1000 Application X-SENS-TEMP-PT1000 temperature sensor to be used for X-AIRCONTROL or other systems; can be connected to X-AIR-ZMO zone modules Temperature measurement Sensor for rectangular and circular extract air ducts Measuring range 40 to 85 C The zone module automatically recognises the temperature sensor (plug and play) Parts and characteristics Protective tube with sensor head and flange to be screw-fixed to the installation surface Connecting cable Protective tube made of plastic

X-SENS-TEMP-EXH X-SENS-TEMP-PT1000 AIR QUALITY SENSOR X-SENS-VOC Application X-SENS-VOC air quality sensor to be used for X-AIRCONTROL or other systems; can be connected to X-AIR-ZMO zone modules Measurement of the concentration of volatile organic compounds Sensor for rectangular and circular extract air ducts Measuring range: 450 to 2000 ppm Plug-in connection for supply voltage and for communication with the zone module

The zone module automatically recognises the air quality sensor (plug and play) Parts and characteristics Casing with flange to be screw-fixed to the installation surface Protective tube with sensor head, for installation into a duct Plug-in cable Modbus RTU data interface Plastic casing X-SENS-CO2-RH Application X-SENS-CO2-RH combination sensor to be used for X-AIRCONTROL or other systems; can be connected to X-AIR- ZMO zone modules Measurement of the CO concentration and relative humidity 2 Room sensor for use inside a room Measuring ranges 0 to 2000 ppm and 0 to 100% rh The zone module automatically recognises the sensor (plug and play) Parts and characteristics Casing with sensors for surface mounting on walls 0 10 V DC analogue signals Plastic casing X-SENS-VOC

X-SENS-CO2-RH MOTION DETECTOR X-SENS-PIR-SM Application X-SENS-PIR-SM motion detectors to be used for X-AIRCONTROL or other systems; can be connected to X-AIR- ZMO zone modules

For detecting if there are people in a room (occupancy) 180 operational range Casing to be flush mounted into walls Parts and characteristics Casing with PIR sensor, to be flush mounted into walls Volt-free digital output White plastic casing X-SENS-PIR-FM Application X-SENS-PIR-SM motion detectors to be used for X-AIRCONTROL or other systems; can be connected to X-AIR- ZMO zone modules For detecting if there are people in a room (occupancy) 360 operational range Casing to be surface mounted on ceilings Parts and characteristics Casing with PIR sensor to be surface mounted on ceilings Volt-free digital output White plastic casing X-SENS-PIR-SM X-SENS-PIR-FM

OTHER

X-SENS-DEWPT Application X-SENS-DEWPT dew point monitor to be used for X-AIRCONTROL or other systems; can be connected to X-AIR- ZMO zone modules Dew point temperature monitoring Sensor head for chilled ceilings Switching point: 92% rh Parts and characteristics Casing to be surface mounted on walls Separate sensor casing for chilled surfaces Volt-free digital output Plastic casing X-SENS-SPLITTER Application X-SENS-SPLITTER four-way splitter to be used with X-AIRCONTROL or other systems; used to connect sensors and control panels via Modbus Adapter used to connect up to four components to terminals in case the connection cables have bare wire ends; also to connect RJ12 plugs. Plastic casing X-SENS-DEWPT X-SENS-SPLITTER Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-15 TROX GmbH

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS Installation details, Basic information and nomenclature INSTALLATION DETAILS Installation and commissioning X-SENS-TEMP-RH-EXH, X-SENS-TEMP-PT1000 Choose a suitable place for the sensor to mount it inside a duct Use the cable to connect the sensor to the zone module The zone module automatically recognises the sensor (plug and play) X-SENS-VOC Choose a suitable place for the air quality sensor to mount it inside a duct Use the cable to connect the sensor to the zone module The zone module automatically recognises the air quality sensor (plug and play) X-SENS-CO2-RH Mount the lower part of the casing to a junction box or to the wall Connect the wires Attach the upper part of the casing The zone module automatically recognises the air quality sensor (plug and play) X-SENS-PIR-SM Ensure that the installation location is suitable for the 180 operational range and for the detection range Wall installation: Preferably 1.1 to 2.2 m above the floor (4 m max.) Connect the wires Mount the lower part of the casing to a junction box or to the wall Put the cover on Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-15 TROX GmbH

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS Configure the 'motion detector' function on the zone module X-SENS-PIR-FM Ensure that the installation location is suitable for the 360 operational range and for the detection range Ceiling installation: Preferably 2.5 to 3.0 m above the floor (10 m max.) Connect the wires Fix the lower part of the casing to the ceiling Attach the upper part of the casing and the cover plate Configure the 'motion detector' function on the zone module X-SENS-DEWPT The sensor casing should be fixed in the coldest area of the chilled surface (measurement location) The installation area may be flat or curved (chilled ceiling or circular duct) Fix the casing to the wall Connect the wires Configure the 'dew point monitor' function on the zone module X-SENS-SPLITTER Mount the splitter onto a mounting rail Plug in the data cable to the zone module (RJ12 plug) Plug in the data cables to the sensors and actuators and to the control panel (RJ12) The maximum cable length is 30 m. Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-15 TROX GmbH

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Tel.: +49 (0)2845 202-0 Fax: +49 (0)2845 202-265 Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0)2845 202-0 Contact Technical service +49 (0)2845 202-400 Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-05-15 TROX GmbH