IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Reflective Optical Beam Smoke Detector User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

FIRERAY 5000 range USER GUIDE

Apollo Intelligent Auto Aligning Beam Detector. User Guide

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Installation, Operating and Maintenance Manual

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Intelligent Security & Fire Ltd

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

The complete conventional fire warning system

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Conventional Fire Alarm System 2014 V1.2

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ID2000. operating manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Interface Modules for SENTRI

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

this is by far the best beam money can buy

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

FAAST LT SET-UP AND TROUBLESHOOTING GUIDE. CONTENTS Introduction...1 Wiring up a FAAST LT unit...1. Setting the Fan speed...7

Carbon Monoxide Transmitter

Memco Panachrome Universal Controller Installation Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Application, Installation, Operation & Maintenance Manual

DYGIZONE GJD910 Lighting Controller & Enunciator

Control Panel User Guide

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

OPERATOR S MANUAL MR-2100/2200. Fire Alarm Control Unit. Revision 0 Document #: LT-2002

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

Operation & Maintenance Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Refrigerated air dryers

INSTRUCTION MANUAL P Heating and 1 Cooling

Public Safety DAS Annunciator Panel

OVEN INDUSTRIES, INC.

Dryer Controller M720

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

Conventional Releasing Control Panel

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

FEC403EN Installation Manual

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

Control Panel User Guide

Remote NAC Power Supply D7038

Open-area Smoke Imaging Detector. Engineering Specification

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

USER MANUAL Digital CO Monitor Model CO30

System 800 Addressable Fire Detection & Alarm System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

GV2 Series Control Panels

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Easy Series ICP-EZM2. System Reference Guide

Section 8 System Operation

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Operating Instructions

User Manual. Dryer Controller M720

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

ZoneSense PLUS. Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Control/Communicator Installation Manual

MODEL B2 INSTALLATION MANUAL

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Summit 3208GLD USER MANUAL. Electronics Line

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

user manual Document No , Revision 03 November 2015

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

FEC400 Series. Installation Manual

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

Property of Monitronics Inc

Laptop / PC Programming Manual

SFC-200 SERIES LED FIRE ALARM PANEL

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

OPERATION AND INSTALLATION MANUAL

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

RPM1600 Series Room Pressure Monitors

Wiring Instructions (01-09)

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

ZNS MICROPROCESSOR BASED CONVENTIONAL FIRE ALARM CONTROL PANEL. Installation & Operation Manual

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Transcription:

End To End Optical Beam Smoke Detector Additional Information EN

1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important to choose the correct method of wiring. Incorrect wiring may result in a Controller isolating subsequent devices on that zone if it enters a Fault condition, and may prevent these subsequent devices signalling a Fire condition back to the FCP. If the FCP monitors for point detector removal, it is possible to use the following wiring diagrams which use diodes to provide zone continuity in the event of a Fault state on any Controller. Two Receivers connected to Controller: see note 1 ZONE - ZONE + Single Receiver connected to Controller on Receiver 1 : see note 1 ZONE - ZONE + Note 1 - This component is the Fire Resistor. Its value is specified by the FCP manufacturer, and is not supplied with the System Controller. For U.S. installations it is typically a short circuit. Note 2 - Recommended diode type: Schottky, 60Volt, 1Amp; must be UL listed for installations meeting NFPA72. 2

1. Multiple Zone Wiring (continued) If the FCP does not monitor for detector removal, it is recommended that the following wiring diagram be used. For installations conforming to UL268 and NFPA72, the following diagram MUST be used when wiring multiple Controllers onto one zone. ZONE + see note 1 see note 1 ZONE - EOL Systems Before Last on Zone Last System on Zone Note 1 - This component is the Fire Resistor. Its value is specified by the FCP manufacturer, and is not supplied with the System Controller. For U.S. installations it is typically a short circuit. EOL - End of Line component. This is supplied with the FCP, and not supplied with the System Controller. Do NOT wire to any unused relay pairs. 3

2. Display and Indicators 2.1 LCD Icon Layout Receiver Number Degrees & LED Setting Latched / Reset Seconds Minutes Signal Strength Compensation Level User Prompt Fire Controller Setting Warning External Reset Fault Busy System Locked / Unlocked Bar Graph % / V Address Setting Alignment Mode Laser Receiver Find Beam Alignment Delay To Fire Fire Test Controller Settings LASER Targeting Fire Threshold Delay To Fault Receiver Settings 2.2 Receiver Status Indicators The Green and Amber LEDs flash during alignment to indicate alignment status. Refer to alignment procedure for further information. The Red LED will flash every 10 seconds when a fire is detected during normal operation. 2.3 Controller Status Indicators Condition (LEFT HAND LED) STATUS LED (MIDDLE LED) STATUS LED RELAY STATE RELAY STATE Normal No Flash No Flash Open Closed Fault (Trouble) Flashes AMBER every 10 seconds Flashes AMBER every 10 seconds Open Open Fire (Alarm) Flashes RED every 10 seconds Flashes RED every 10 seconds Closed Closed System Controller Status LED (Right-hand LED) flashes green every 10 seconds. 4

3. User Menu 3.1 User Menu Overview The USER MENU allows system settings to be viewed only. The USER MENU will timeout 15 minutes after the last key press. CONTROLLER SOFTWARE VERSION CONTROLLER LED ON/OFF STATUS RECEIVED SIGNAL % RECEIVER SOFTWARE VERSION COMPENSATION LEVEL RECEIVER STATUS (Refer to Troubleshooting for error codes) THRESHOLD DELAY TO DELAY TO 5

4. Engineering Menu 4.1 Engineering Menu Overview The ENGINEERING MENU allows system settings to be changed. The ENGINEERING MENU will timeout 60 minutes after the last key press. RECEIVER FIND CONTROLLER SETTINGS LASER TARGETING RECEIVER SETTINGS BEAM ALIGNMENT TEST THRESHOLD DELAY TO DELAY TO 6

4.2 Receiver Settings 4.2.1 Receiver Settings Overview VIEW SIGNAL STRENGTH COMPENSATION SOFTWARE RX GAIN SET LATCHING MODE HARDWARE RX GAIN 7

4.3 Controller Settings 4.3.1 Controller Settings Overview PASSCODE CHANGE SCREEN CONTROLLER STATUS LED ON/ OFF SCREEN 8

4.3.2 Passcode Change Screen This screen allows the user to change the Pass Code used to access the ENGINEERING MENU. NOTE: The number being altered flashes. A partial passcode (ie. with dashes in it) will not be accepted. Default Pass Code: 1 2 3 4 Change digit Move between digits Save new Pass Code Abort change 9

4.3.3 Controller Status LED ON/OFF Screen This setting controls whether the System Controller Status LED will flash. OR Toggle ON or OFF Confirm setting Abort change Document Number: 0044-063-01-EN 10