INSTALLATION INSTALLING BATTERIES INSTALLATION INSTRUTIONS RT7 WIRED 7 DAY PROGRAMMABLE ROOM THERMOSTAT 1- Remove the batteries cover which is placed on the front of thermostat. 2- Insert the 2 batteries AA supplied. Note the correct polarity according to the engraving on the thermostat when inserting the batteries. 3- Replace the batteries cover. Pack contains...1 Installation...1 Installing batteries...1 Mounting of wall mounting plate...1 Wiring...2 Mounting of the thermostat...2 Installer settings...2 Advanced installer setting...2 Troubleshooting...4 Technical specifications...4 PAK ONTAINS MOUNTING OF WALL MOUTING PLATE The digital room thermostat is fixed on the wall with the wall plate which is supplied with the product. 1- Unscrew the 2 screws under the thermostat. 2- Remove the wall plate from the thermostat. x1 Thermostat AA Batteries (LR6) Screw Anchor Screws 3- Secure the wall plate with the two screws provided using the horizontal and vertical holes. RTE7REA NEO ENG FP V02 22 04 2015 1
WIRING All electrical installation work should be carried out by a suitably qualified Electrician or other competent person. If you are not sure how to install this thermostat consult either with a qualified electrician or heating Engineer. Do not remove or refit the appliance onto the backplate without the mains supply to the system being isolated. Recommended locations for your thermostat. To ensure that your thermostat provides accurate readings and controls effectively, it must be installed approximately 1.5 m above floor level on an inside wall, away from direct sunshine and any other sources of heat or cold such as radiators, cold draughts, etc. All wiring must be in accordance with IEE regulations. This product is for fixed wiring only. N OM NO Important: The thermostat measures the temperature of the place where it is installed. It does not take into account the temperature differences that may exist between different locations in the house if the temperature is not uniform. INSTALLER SETTINGS N OM NO OM = Live N = Normally closed switch out (Satisfied) NO = Normally open switch out (call for Heat) ADVANED INSTALLER SETTING Access Move the mode slider to position. Select the Programming slider position and press for 5 seconds to go into the dedicated installer setting. 5 sec. MOUNTING OF THE THERMOSTAT Slider position Icon Installer mode access 1- Replace the thermostat on the wall mounting plate. 1 Set / F temperature unit 2 Set 12 or 24 hours clock 3 Set calibration of the temperature displayed 4 Program lock 5 Select the type of control: 2 points or TPI Set / F temperature The pre-set temperature is elsius ( ). 2- Secure the thermostat by screwing the both locking screws under the thermostat. 1- Rotate the dial to change to degree Fahrenheit. 2
Set 12/24 hours clock The pre-set value is 12 hours clock. 1- Rotate the dial to ON and locked. 1- Rotate the dial to change to 24 hr. am Tu Select 2 points/tpi Set calibration Important: This operation is reserved for professional installers only; any wrong changes would result in control anomalies. hange should only be made if the temperature measured (measured by a reliable thermometer) is different by at least 1 compared to the setpoint temperature of the room thermostat. The calibration adjusts the temperature measured by the ambient temperature sensor to compensate for a deviation from + 3 to - 3 in increments of 0.1. IMPORTANT: Before carrying out the calibration it is recommended to wait for 4h after a setpoint temperature modification to insure that the ambient temperature is stabilized. The pre-set calibration value is 0. 1- Rotate the dial to adjust the calibration to the desired value. 2 points = ON/OFF regulation. TPI = Proportional control algorithm. The pre-set control algorithm is TPI. 1- Rotate the dial to change to 2 points control algorithm. Tu am am Note regarding the Advanced installer settings: If MODE slider is moved or no press/rotation for 15 seconds, it will discard changes and exit installer mode. Tu Program lock The product is unlocked by default, OFF is displayed. When program lock function is turned on then following functions will be disabled: - Regardless of physical location, Program Slider will always remain as per RUN mode (except to access Installer settings). - In Mode Slider AUTO position: Manual override will not work. - In omfort Slider position: mode will remain as per AUTO mode. - BOOST function is disabled. 3
TROUBLESHOOTING TEHNIAL SPEIFIATIONS Display disappears on thermostat. - heck batteries. - Replace the 2 batteries. Only use alkaline 1.5V AA (LR6) batteries. Do not use rechargeable batteries. The heating does not come on or does not go off. - Your room thermostat may have been set up close to a source of heat or on a cold wall put it in a recommended location (see the Installing section on page 2 for these locations). - heck that the communication works between the thermostat and the boiler. You want to change the operating mode but when you move the mode slider nothing happens. - If the lock symbol is being displayed, then the thermostat is locked. - Unlock the thermostat by following the instructions for doing so in the "program lock" section (see page 3). The thermostat is in Auto Mode but programs are not being executed by the boiler: - Ensure that the thermostat is in good working condition. - hange the batteries. The thermostat does not control properly. - Thermostat sensor may be influenced by a source of heat or cold. - heck that the communication works between the thermostat and boiler. If the problem persists, contact your installer. - Power supply: 2 alkaline 1.5 V AA (LR6) batteries. - Battery life: approx. 2 years. - Relay outputs: 5(2)A - Rated impulse voltage: 4000V. - Micro disconnection: Type 1B. - Pollution degree: 2. - Automatic action: 100,000 cycles. - lass II. Note: It is recommended to replace annually as part of the normal system service and before leaving the property empty for a prolonged period. Standards: LVD EM RoHS EN60730-1 EN60730-2-9 EN62311 EN60730-1 EN60730-2-9 EN50581 Environment: - Operation temperature: 0 to +40. - Manual temperature setting range: from +5 to +30. - Storage temperature: from -10 to +60. - Humidity: 80% at +25 (without condensation) - Protection rating: IP30. Manufactured by: IMHOTEP création The on the product indicates that you must dispose of it at the end of its useful life at a special recycling point, in accordance with European Directive WEEE 2012/19/EU. If you are replacing it, you can also return it to the retailer from which you buy the replacement equipment. Thus, it is not ordinary household waste. Recycling products enables us to protect the environment and to use less natural resources. ompliance declaration: we hereby declare under our sole responsibility that the products described in these instructions comply with all the main requirements of the LVD 2006/95/E, EM 2004/108/E, RoHS 2011/65/EU and are manufactured using processes which are certified ISO 9001 V2008. www.neomitis.com reating innovative solutions for ambient comfort NEOMITIS LIMITED - 4th Floor, Lincoln House, 300 High Holborn, London W1V 7JH Registered in England and Wales No: 9543404 NEOMITIS is a registered trademark of O INTEH - SIRET 42243514900048 RS ANGERS Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contact_uk@neomitis.com 4 Registered trademarks - All rights reserved
ONTROLS AND DISPLAY OPERATING INSTRUTIONS RT7 WIRED 7 DAY PROGRAMMABLE ROOM THERMOSTAT Thermostat Batteries compartment Programming Tu am Reset button Enter/boost button Programming sliders sequences: Time/day Day to be programed omfort period setting omfort temperature Eco temperature Run. Overview...1 ontrols and display...1 Settings...1 Initial power up...1 Programming...2 Set day and clock...2 Set the program day...2 Set the program omfort period...2 Temperatures setting...2 Operating...3 Mode selection and description...3 Manual: a temporary change...3 Boost...3 Factory settings...3 Troubleshooting...4...4 What is a room thermostat...4 OVERVIEW LD Display Pairing icon (RF version) Advanced settings Measured room temperature Lock function Mode indicator Hour SETTINGS INITIAL POWER UP 1- To start: insert the two AA batteries provided into the battery compartment. the LD screen as shown for two seconds. Programmed omfort period Low battery icon Frost protection icon icon Text informations Temperature setpoint Days omfort or Eco mode icon 2- show: - The ambient temperature ( ) Thank you for purchasing our RT7, 7 day have created and designed our products It is this ease of operation that is intended energy and money. Note: RTE7REa NEO ENG FP V02 22 04 2015 1
PROGRAMMING SET DAY AND LOK 1- to position. Underscoring of 2- the day. to decrement the day. SET THE PROGRAM OMFORT PERIOD 1- time, move the Programming. 2- Press Mo = Monday ; Tu = Tuesday ; We = Wednesday ; Th = Thursday ; Fr = Friday ; Sa = Saturday ; Su = Sunday 3- time, move the Programming. 4-3- 4- To set the current time, turn the ckwise, to decrement the time. SET THE PROGRAM DAY 1- to position. The current day is Monday. Press 5- Repeat for the second comfort period, and for the third comfort period. omfort period Default times omfort period 2 Start at 12:00 pm End at 02:00 pm omfort period 3 Start at 05:00 pm End at 10:00 pm Note: if you wish not to use a period then this can be done by oinciding the End time with Start time. TEMPERATURES SETTING Two temperatures can be set: omfort temperature and Economy temperature. 1- To set the omfort temperature, move the Programming 2- -. in increments of 0.5. 2- Option 1: ming. Monday, press. Under- Option 2: ng. programmed and press to 3- To set the Economy temperature, move the Programming. (50 F). 2
4- - in increments of 0.5. NOTE: This is the temperature of your comfort periods. 5- OPERATING BOOST BOOST: Boost mode is a temporary rate at the comfort temperature for 1 hour. At the end of 1 hour the BOOST is entered by pressing / button. MODE SELETION AND DESRIPTION Mode sliders sequences: Auto mode omfort mode Economy mode Standby. AUTO: Automatic mode. The and temperature program (refer to "programming" section page 2). OMFORT: Permanent comfort temperature setpoint. The 20 temperatures setting to page 2. position. FATORY SETTINGS Settings Factory settings omfort temperature 20 Eco temperature 10 omfort period 1 am am omfort period 2 Start at 12:00 pm End at 02:00 pm omfort period 3 Start at 05:00 pm End at 10:00 pm EO: Permanent eco mode. - rature setting is 10 (50 F). Refer to section temperatures page 2. STANDBY: Permanent standby mode with frost protection. The at the frost protection temperature factory set. i.e 8. MANUAL: A TEMPORARY HANGE MANUAL: Indicates when the temperature has been moved mode. 3
TROUBLESHOOTING WHAT IS A ROOM THERMOSTAT The boiler is not heating: off. If no increase set temperature. Nothing in the display : The room temperature is not high enough, the boiler is not providing enough heat: - heck the active operating mode - the room thermostat - heck the active desired temperature and increase it if needed (see page 2). The temperature in the room is lower than the setpoint temperature: period. You made a mistake while setting: settings section have made. The system is not heating but is on: - If If the problem persists, then contact your installer. If either Service due soon or Service due appear in the display then contact your installer or land lord. TEHNIAL SPEIFIATIONS the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature and switching it off once this set temperature has been reached. Turning a room thermostat to a hi- room heats up depends on the design of the heating system, for exa- - energy and cost you more money. - other rooms by adjusting the TRVs. - www.neomitis.com reating innovative solutions for ambient comfort NEOMITIS LIMITED - 4th Floor, Lincoln House, 300 High Holborn, London W1V 7JH Registered in England and Wales No: 9543404 NEOMITIS is a registered trademark of O INTEH - SIRET 42243514900048 RS ANGERS Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contact_uk@neomitis.com 4 Registered trademarks - All rights reserved