Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Similar documents
Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

CCTV Portfolio. Phoenix Explosion-proof Range

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Approved by: Document no.: EGT

INSTRUCTION MANUAL (ATEX / IECEx)

[ TECHNOLOGY ] and does this definition affect a burner.

Beamex. Calibration White Paper. Calibration in hazardous areas

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Beamex Calibration White Paper. Calibration in hazardous areas

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Overview of Hazardous Locations as They Relate to Solenoid Valves

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

INSTRUCTION & SERVICE MANUAL

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Flameproof Manual Call Points Series MCP

Dual certification! Air handling units for potentially explosive atmospheres

High bay LED lighting fixture

Guide for hazardous areas

INSTRUCTION MANUAL (ATEX / IECEx)

4) Intrinsic Safety Certification

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

ATEX, NOMENCLATURE AND CODING

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

UL HAZARDOUS LOCATIONS SERVICES

ATEX, NOMENCLATURE AND CODING

Explosion-protected actuator Page 259 of 292

Electrical Installations Design, Selection, Erection and Inspection

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

OPTIBAR DP 7060 Supplementary Instructions

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

manual addendum DELPHI Ex

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Dräger Polytron 8310 IR Detection of flammable gases and vapour

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Hazardous Area Zirconia Oxygen Systems

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

standards: standards:

S T R I T T & P R I E B E I N C.

Explosion-protected network cameras Safety first

Guide to Intrinsically Safe Portable Radios

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Certification Supplement Manual

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

1. GENERAL TECHNICAL INFORMATION

Explosion-proof Immersion Heater Type D-8660

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Fact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Motorola Professional Series Enhanced ATEX Portable Radios. October 2007

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Explosion Proof Manual Call Points Series MCP

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Desiccant. Breather Range

XLFE-4/1. Borosilicate glass globe

Dräger Polytron 8700 IR Detection of flammable gases and vapors

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Hazardous Area Portable Fan Heater The Bulldog

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Intrinsically Safe Solutions

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog

OPTIWAVE X500 Supplementary Instructions

THE BELGIAN PIONEER IN GAS DETECTION

Fact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

VSD AND SS DRIVING ATEX MOTORS February 2014

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

DB4 Range - SPEAKERS - Up to 25 Watts

TRASCO ATEX Couplings

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Manual Power relay SR853

ANNEX GD-CERT-EX-EN SIT

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Transcription:

Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure.

Video monitoring under extreme conditions Security Products from Siemens is a world leader in the manufacture of flameproof housings and Pan & Tilt heads. These are typically used in petrochemical, industrial, aerospace, or offshore industries, on sites where there is a risk of explosion because volatile gases, vapours, mists or dusts are present. The Phoenix range is recognised and chosen internationally by customers who require the best engineered solution for security in hazardous areas.

Video products for potentially explosive environments 30 years of proven reliability Phoenix range of explosion-proof housings and Pan & Tilt heads have been used around the world for over 30 years. First launched in 1980, the range was chosen because of its engineering performance and reliability - the latest Phoenix range takes this performance even higher, and is now the replacement of choice for upgrades and system expansions. A wide range of applications Since its launch in 1980, the Phoenix range of Pan & Tilt heads and housings have been used in: Oil refineries Oil tankers Oil & gas rigs Pharmaceutical plants Petrochemical plants Rocket launching sites Chemical process Flameproof housings and Pan & Tilt heads are popular in CPI (Chemical Processing Industry) applications, like petrochemical or food and beverage processing plants, that are dealing with volatile vapours, flammable dusts (such as flour, sawdust), and solvent vapours. Safety and Security Personnel safety should always be the number one priority, whether it be lone workers on oil platforms, or processing staff in a chemical plant. The Phoenix Explosion-proof range ensures that process controls and security levels can be maintained in hazardous areas whilst protecting the workforce. Low running costs Phoenix products are available with a range of built-in telemetry receiver options which are compatible with all Siemens telemetry controllers. This eliminates the need and cost of additional ATEX - approved flameproof enclosures. Phoenix housings are available with sunshields and heaters, integral telemetry receivers and wipers. Phoenix housings are also available with a factory pre-build option of cameras/lenses (Baseefa requirement for IIC certification). International Standards Phoenix equipment is certified to meet the rigorous and exacting European ATEX Directive 94/9/EC, and is certified by the internationally-recognised body: Baseefa Ltd. All Phoenix products also meet the relevant European standards for electrical and mechanical safety, as well as electromagnetic compatibility. These standards generally meet or exceed the requirements of most international certification bodies.

CENELEC / IEC Marking Information - Certification Code: Ex II 2 G D Ex d IIB T6 Gb Ex tb IIIC T85 C Db Ex d IIC T6 Gb Ex tb IIIC T85 C Db Features and benefits ATEX Specific Marking Group II: non mining applications Equipment Category 2 giving a level of protection to equipment intended to be used in areas in which explosive atmospheres caused by gases, vapours, mists or air / dust mixtures are likely to be present. This protection is afforded under both normal and fault conditions. G D: for use in gas/vapour/ mist and dust environments EEx: for use in potentially explosive environments d: flameproof, pressure-resistant enclosure according to BS EN 60079-1:2007 IIB: suitable for gas groups IIB & IIA eg ethylene and propane IIC: suitable for gas groups IIC,IIB & IIA eg hydrogen, acetylene, ethylene & propane Suitable for use in Zones 1 and 2 (Intermittent hazards which are present for up to 1,000 hours per annum) T85 C Temperature class. Based on an ambient temperature of 40 C, maximum surface temperature will not exceed 85 C Options for Gas Group IIB and IIC explosive environments Suitable for use in hazardous conductive dust conditions Each unit is individually pressure-tested Housings include thermostaticallycontrolled demister and sunshield Cost effective wiper options Pre-build option available for camera and lens

Phoenix Explosion-proof selection guide MODEL FP50B FH07B-30 FH07B-40 FH07C-30 FH07C-40 FPHC-40 Pan & Tilt Housing Housing Housing Housing Camera Head FEATURES Approvals ATEX Ex II2GD Ex d IIB T6 Gb Ex tb IIIC T85 C Db Ex II2GD Ex d IIC T6 Gb Ex tb IIIC T85 C Db Load rating 40 kg 40 kg Mounting Side mount Side mount Presets Standard Standard Heater Standard Standard Standard Standard Sunshield Standard Standard Standard Standard Factory fitted wiper Option Option Option Option Option Factory fitted 10fn receiver Option Option Option Option Option Factory fitted 17fn receiver Option Option Option Option Option Tamper switch Option Option Option Option Option DIMENSIONS External - Length 448 mm 545 mm 675 mm 545 mm 675 mm 675 mm (Housing) 448 mm (Pan & Tilt) External - Width 167 mm 210 mm 210 mm 210 mm 210 mm 210 mm (Housing) 167 mm (Pan & Tilt) External - Height 286 mm 186 mm 186 mm 186 mm 186 mm 186 mm (Housing) 286 mm (Pan & Tilt) Internal - Length 290 mm 420 mm 290 mm 420 mm 420 mm Internal - Width 114 mm 114 mm 114 mm 114 mm 114 mm Internal - Height 94 mm 94 mm 94 mm 94 mm 94 mm Weight 19 kg 10 kg 11.8 kg 10 kg 11.8 kg 11.8 kg (Housing) 19 kg (Pan & Tilt) OTHER Environmental EN 60529 Power Options (230 VAC, 50 Hz) (24 VAC, 50/60 Hz) (110 VAC, 60 Hz) IP67 IP67 IP67 IP67 IP67 IP67 FP50B FP50B/L FP50B/U FH07B-30 FH07B-30/L FH07B-30/U Recommended brackets FH07B-40 FH07B-40/L FH07B-40/U FH07C-30 FH07C-30/L FH07C-30/U FH07C-40 FH07C-40/L FH07C-40/U FPHC-40 FPHC-40/L FPHC-40/U Warranty 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years Factory Fit Options FH07W Wiper kit for FH07 housings, 230 VAC, 50 Hz FH07W/L As above but 24 VAC 50/60 Hz FH07W/U As above but 110 VAC 60 Hz FH07-CERT Factory Fit customer-supplied camera and lens plus ATEX equipment certification for FH07 IIB housings (additional charge per housing) Telemetry receivers are available as an option. Please contact Customer Support for further details. Accessories FH07-CGLAND Atex II 2 GD compound filled barrier gland for unarmoured cable, suitable for use with Phoenix IIC camera housings. Size: M20 x1.5, for cable sheath diameters in the range 9.5 14 mm. CAHL401x-W Spare wiper arm and blade for FH07 housings 100 kg Swivel mount adaptor ( standard 4 pcd)

Siemens AB Infrastructure & Cities Sector Building Technologies Division Security Products Englundavägen 7 Box 1275 17124 Solna Sweden Tel: +46 8 629 0300 Fax: +46 8 627 0096 Siemens AG Infrastructure & Cities Sector Building Technologies Division Fire Safety and Security Security Products Siemensallee 84 76187 Karlsruhe Germany Tel. +49 (721) 595-4291 Fax: +49 (721) 595-2806 Siemens plc Infrastructure & Cities Sector Building Technologies Division Fire Safety and Security Security Products Suite 7 Castlegate Business Park Caldicot South Wales NP26 5AD UK Main: +44 (0) 1291 437920 Fax: +44 (0) 1291 437943 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Siemens AB - 08/2012 Answers for infrastructure. Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming, and resource shortages. Maximum efficiency has top priority and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. We are the preferred partner for energy-efficient, safe, and secure buildings and infrastructure. www.siemens.com/securityproducts