SUBMITTAL DATA: SLZ-KA9NA......... 9, BTU/H CEILING-CASSETTE INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule No.: GENERAL FEATURES Four-way 2'x2' ceiling-cassette indoor unit for residential applications Built-in drain mechanism for condensate removal; lifts to 19-11/16" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Automatic fan speed control; auto restart following a power outage ed warranty: five years on parts/defects, seven years on compressors OPTIONAL ACCESSORIES Indoor Unit Grille (SLP-15AAUW; required - shipped with unit) Controller Options Wall-mounted Wired Remote Controller (PAR-21MAA) M-NET Control Adapter (MAC-399IF) Remote Temperature Sensor (M21-JKO-37) Handheld Wireless Remote Controller (PAR-FL32MA; req. PAR-SA9FA) Receiver Kit for PAR-FL32MA Handheld Wireless Remote Controller (PAR-SA9FA) Lockdown Bracket for Handheld Controller (RCMKP1CB) Cooling Capacity*....8,4 Btu/h Heating Capacity at 47 F*...1,9 Btu/h * Rating Conditions (Cooling) - Indoor: 8ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB. (Heating at 47ºF) - Indoor: 7ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB. (For data on specific indoor units combinations [all ducted, all non-ducted, and both ducted and non-ducted], see the MXZ-B Technical and Service Manual.) Electrical Requirements Power Supply...8 / 23V, 1-Phase, 6 Hz MCA... 1 A Voltage Indoor - Outdoor S1-S2...AC 8 / 23V Indoor - Outdoor S2-S3... DC 12-24V MSZ-GE SEZ-KD and PEAD-A24 Fan Motor....23 F.L.A. Airflow (Lo - Med - Hi)... 28-3 - 35 Dry CFM 25-29 - 3 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)...29-32 - 38 db(a) DIMENSIONS UNIT INCHES / MM GRILLE INCHES / MM W 22-7/16 / 57 25-5/8 / 65 D 22-7/16 / 57 25-5/8 / 65 H 8-3/16 / 8 13/16 / 19 Weight (Unit/Grille) Lbs...... 36 / 7 kg.... 16 / 3 External Finish (Unit/Grille)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 /.4 Field Drainpipe Size O.D..... 1-1/4 / 32 mm Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side... 3/8" / 9.52 mm Liquid Side.... 1/4" / 6.35 mm Connection Method...Flared MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS Outdoor Unit: MXZ-3B3NA SLZ-KA9NA MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE: Ducted Indoor Units: SEZ-KD9,12,15,18NA, PEAD-A24AA Nonducted Indoor Units: MSZ-GE6,9,12,15,18,24NA, MSZ-FE9,12,18NA, MFZ-KA9,12,18NA, PCA-A24KA, SLZ-KA9,12,15NA, and PLA-A12,18,24BA A combination of both Ducted and Nonducted Indoor Units Refer to the separate submittal forms for the MSZ-GE, MSZ-FE, MFZ-KA, SEZ-KD, SLZ-KA, PEAD, PCA, PLA Indoor Units, and MXZ Outdoor Units. MSZ-FE MFZ-KA PCA-KA SLZ-KA and PLA-ABA
DIMENSIONS: SLZ-KA9NA Unit inch (mm) Refrigerant pipe Models 1/4 inch 3/8 inch SLZ-KA9NA 6.35 mm 9.52 mm 1/4 inch 3/8 inch SLZ-KA12NA 6.35 mm 9.52 mm 1/4 inch 1/2 inch SLZ-KA15NA 6.35 mm 12.7 mm C SD - SLZ-KA9NA for MXZ Multiple Indoor Unit Styles - 112 MITSUBISHI ELECTRIC / HVAC 1 34 Lawrenceville Suwanee Rd Suwanee, GA 324 Tele: 678-376-29 Fax: 8-889-994 Toll Free: 8-433-4822 (#3) www.mehvac.com
Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: SUBMITTAL DATA: SLZ-KA12NA & SUZ-KA12NA 12, BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Schedule No.: M-SERIES Indoor Unit: SLZ-KA12NA Outdoor Unit: SUZ-KA12NA GENERAL FEATURES Four-way 2'x2' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 19-11/16" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed:, Medium, Automatic restart following a power outage ed warranty: five years parts and seven years compressors ACCESSORIES Indoor Unit Grille (SLP-15AAUW; required - shipped with unit) Controller Options Wireless Wall-mounted Remote Controller Kit (MHK1)* Portable Central Controller (MCCH1)* Outdoor Air Sensor (MOS1)* Wired Wall-mounted Controller (PAR-31MAA)* Simple MA Remote Controller (PAC-YT53CRAU)* *See Submittal for information on each option. Remote Temperature Sensor (M21-JKO-37) Hand-held Wireless Remote Controller (PAR-FL32MA;req.PAR-FA32MA-E) Wireless Signal Receiver PAR-FA32MA (for PAR-FL32MA) Lockdown Bracket for Hand-held Controller (RCMKP1CB) 13 Mitsubishi Electric US, Inc.
SPECIFICATIONS: SLZ-KA12NA & SUZ-KA12NA Cooling* Rated Capacity.... 11,1 Btu/h Minimum to Maximum Capacity Range... 3,4-13,3 Btu/h SEER...15.4 Btu/h/W EER...12. Btu/h/W Total Input....9 W Heating at 47 F* Rated Capacity....13,6 Btu/h Minimum to Maximum Capacity Range... 3,1-17,1 Btu/h HSPF...9.6 Btu/h/W COP...3.38 Total Input....1,18 W Heating at 17 F* Rated Capacity....8,3 Btu/h Rated Total Input...93 W COP...2.62 Maximum Capacity**...8,3 Btu/h Maximum Total Input...1,31 W * Rating Conditions per AHRI Standard Cooling Indoor: 8º F (27º C) DB / 67º F (19º C) WB Cooling Outdoor: 95º F (35º C) DB / 75º F (24º C) WB Heating at 47ºF Indoor: 7º F (21º C) DB / 6º F (16º C) WB Heating at 47ºF Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F Indoor: 7º F (21º C) DB / 6º F (16º C) WB Heating at 17º F Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB ** Maximum Capacity is at full speed and performance for INVERTER-driven System. Electrical Requirements Power Supply... 8 / 23V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size....15 A Voltage Indoor - Outdoor S1-S2...AC 8 / 23V Indoor - Outdoor S2-S3...DC ±24V OPERATING CONDITIONS Cooling Heating Maximum Minimum Maximum Minimum Indoor Intake Air Temp. 95 F (35 C) DB 71 F (22 C) WB 67 F (19 C) DB 57 F (14 C) WB 8 F (27 C) DB 67 F (19 C) WB 7 F (21 C) DB 6 F (16 C) WB Outdoor Intake Air Temp. 115 F (46 C) DB 14 F (-1 C) DB 75 F (24 C) DB 65 F (18 C) WB -4 F (- C) DB -5 F (-21 C) WB Indoor Unit MCA...1 A Fan Motor Output... W Fan Motor (ECM)...28 F.L.A. Airflow (Lo - Med - Hi).... 28-3 - 39 Dry CFM 25-29 - 35 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)...3-34 - 39 db(a) DIMENSIONS UNIT INCHES / MM GRILLE INCHES / MM W 22-7/16 / 57 25-5/8 / 65 D 22-7/16 / 57 25-5/8 / 65 H 9-1/4 / 235 13/16 / Weight (Unit/Grille) Lbs...... 36 / 7 kg....16.5 / 3 External Finish (Unit/Grille)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 /.4 Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven MCA...12 A MOCP....15 A Fan Motor (ECM)...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIMENSIONS INCHES / MM W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...77 lbs. / 35 kg External Finish... Munsell No. 3Y 7.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...3/8" / 9.52 mm Liquid Side....1/4" / 6.35 mm Max. Refrigerant Pipe Length.... 65' / 19 m Max. Refrigerant Pipe Height Difference... 4' / 12 m Connection Method...Flared Notes: 13 Mitsubishi Electric US, Inc.
DIMENSIONS: SLZ-KA12NA Unit : inch (mm) 19/32~1-15/32(15~37) 19/32~1-15/32(15~37) Ceiling hole 22-11/16~24-13/32(576~6) Fresh air intake 16-17/32(4) Suspension bolt pitch -7/8(53) Suspension bolt pitch 22-7/16(57) 13-3/16(335) 1-7/32(31) 22-7/16(57) Detail drawing of fresh air intake 3-15/16( 1) 3-1/8( 2.8) Burring hole 1 4-21/32(118) Ceiling surface 1(25) 2-7/8( 73.4) Cut out hole 1 2-1/14(57) 2-7/32(56) 7-27/32(199) 13-27/32(352) 13-3/16(335) 19/32~1-15/32(15~37) 22-11/16~24-13/32(576~6) Ceiling hole 19/32~1-15/32(15~37) 3-7/16(87) 2-19/32(66) 4-3/4(121) 3-21/32(93) Refrigerant pipe (gas) Refrigerant pipe (liquid) 1-1/2~2-9/32(38~58) Suspension bolt lower edge 21/32(17) 7-15/16(2) Terminal block 9-1/16(23) Grille Ceiling surface Drain pipe VP-25 connection (O.D. 1-1/4( 32)) Suspension bolt M1 or W3/8 7-19/32(193) 8-3/16(8) 9-1/4(235) +3/16 +5 (27 ) 25/32() 1-1/16 Wiring entry 7-5/32(182) 1-7/8(48) 25-19/32(65) 11-27/32(31) Air outlet hole 2-5/32(55) 1-3/8(35) V/M 25-19/32(65) 11-27/32(31) Air outlet hole Brand label V/M Grille Drain hole Auto vane 14-27/32(377) Air intake hole Models SLZ-KA9NA SLZ-KA12NA SLZ-KA15NA Refrigerent pipe (liquid) 1/4 inch ( 6.35mm) 1/4 inch ( 6.35mm) 1/4 inch ( 6.35mm) Refrigerent pipe (gas) 3/8 inch ( 9.52mm) 3/8 inch ( 9.52mm) 1/2 inch ( 12.7mm) V/M 14-27/32(377) Air intake hole 1-3/8(35) 2-5/32(55) V/M Air intake grille Vane motor 13 Mitsubishi Electric US, Inc.
DIMENSIONS: SUZ-KA12NA FORM# SLZ-KA12NA - SUZ-KA12NA - 1311 13 Mitsubishi Electric US, Inc. 134 Satellite Boulevard Suwanee, GA 324 Tele: 678-376-29 Fax: 8-889-994 Toll Free: 8-433-4822 www.mehvac.com
M-SERIES SUBMITTAL DATA: SLZ-KA15NA & SUZ-KA15NA 15, BTU/H CEILING-CASSETTE HEAT-PUMP SYSTEMS Job Name: System Reference: Date: Electrical Requirements Power Supply... 8 / 23V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size....15 A Voltage Indoor - Outdoor S1-S2...AC 8 / 23V Indoor - Outdoor S2-S3...DC ±24V Indoor Unit: SLZ-KA15NA Outdoor Unit: SUZ-KA15NA GENERAL FEATURES Four-way 2'x2' ceiling-cassette indoor unit for ceiling recessed applications Built-in drain mechanism for condensate removal; lifts to 19-11/16" Wide air-flow pattern for better air distribution Design features ventilation air intake knockout Long-life air filter included with indoor unit Indoor unit powered from outdoor unit using A-Control Choice of fan speed:, Medium, Automatic restart following a power outage ed warranty: five years parts and seven years compressors ACCESSORIES Indoor Unit Condensate Pump (BlueDiamond X87-711/721; 115/23V) Condensate Pump (Sauermann SI3-115/23; 115/23V) Grille (SLP-15AAUW; required - shipped with unit) Outdoor Unit Three-pole Disconnect Switch (TAZ-MS33) Air Outlet Guide (MAC-889SG) Mounting Base (DSD-4P) Mounting Pad (ULTRILITE1) Wall Mounting Bracket (QSWBM-1) Controller Options Wireless Controller (MHK1) Wired Remote Controller (PAR-32MAA-J) Wireless Interface for kumo cloud (PAC-WHS1WF-E) Thermostat Interface (PAC-US444CN-1) Hand-held Wireless Remote Controller (PAR-FL32MA; req.par-fa32ma-e) Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA-E) SPECIFICATIONS Cooling 1 Rated Capacity....15, Btu/h Minimum to Maximum Capacity Range... 3,8-17,7 Btu/h SEER...16. Btu/h/W EER...1.2 Btu/h/W Total Input....1,46 W Heating at 47 F 2 Rated Capacity....18, Btu/h Minimum to Maximum Capacity Range... 3,1-22, Btu/h HSPF...9.6 Btu/h/W COP...2.71 Total Input....1,95 W Heating at 17 F 3 Rated Capacity....1, Btu/h Rated Total Input...1,31 W COP...1.99 Maximum Capacity **...12, Btu/h Maximum Total Input...1,97 W 1 Cooling Indoor: 8º F (27º C) DB / 67º F (19º C) WB * 1 Cooling Outdoor: 95º F (35º C) DB / 75º F (24º C) WB * 2 Heating at 47º F Indoor: 7º F (21º C) DB / 6º F (16º C) WB * 2 Heating at 47º F Outdoor: 47º F (8º C) DB / 43º F (6º C) WB * 3 Heating at 17º F Indoor: 7º F (21º C) DB / 6º F (16º C) WB * 3 Heating at 17º F Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB * * Rating Conditions per AHRI Standard ** Maximum Capacity is at full speed and performance for INVERTER-driven System. OPERATING CONDITIONS Cooling 4 Heating Maximum Minimum Maximum Minimum Indoor Intake Air Temp. 9 F (32 C) DB 73 F (23 C) WB 67 F (19 C) DB 57 F (14 C) WB 8 F (27 C) DB 67 F (19 C) WB 7 F (21 C) DB 6 F (16 C) WB Outdoor Intake Air Temp. 115 F (46 C) DB 14 F (-1 C) DB 75 F (24 C) DB 65 F (18 C) WB -4 F (- C) DB -5 F (-21 C) WB 5 4 Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 5 System cuts out at -9º F (-27º C) to avoid thermistor error and automatically restarts at -4º F (-º C). Indoor Unit MCA...1 A Fan Motor Output... W Fan Motor (ECM)...28 F.L.A. Airflow (Lo - Med - Hi).... 28-3 - 39 Dry CFM 25-29 - 35 Wet CFM Air Filter...Polypropylene Honeycomb Sound Pressure Level (Lo - Med - Hi)...31-35 - 4 db(a) DIMENSIONS UNIT INCHES / MM GRILLE INCHES / MM W 22-7/16 / 57 25-5/8 / 65 D 22-7/16 / 57 25-5/8 / 65 H 9-1/4 / 235 13/16 / Weight (Unit/Grille) Lbs...... 36 / 7 kg....16.5 / 3 External Finish (Unit/Grille)... Galvanized-steel Sheets / Munsell 6.4Y 8.9 /.4 Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven Twin Rotary MCA...12 A MOCP....15 A Fan Motor (ECM)...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIMENSIONS INCHES / MM W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...8 lbs. / 36 kg External Finish... Munsell No. 3Y 7.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12.7 mm Liquid Side....1/4" / 6.35 mm Max. Refrigerant Pipe Length.... 65' / 19.8 m Max. Refrigerant Pipe Height Difference... 4' / 12.2 m Connection Method...Flared 16 Mitsubishi Electric US, Inc.
DIMENSIONS: SLZ-KA15NA Unit : inch (mm) 19/32~1-15/32(15~37) 19/32~1-15/32(15~37) Ceiling hole 22-11/16~24-13/32(576~6) Fresh air intake 16-17/32(4) Suspension bolt pitch -7/8(53) Suspension bolt pitch 22-7/16(57) 13-3/16(335) 1-7/32(31) 22-7/16(57) Detail drawing of fresh air intake 3-15/16( 1) 3-1/8( 2.8) Burring hole 1 4-21/32(118) Ceiling surface 1(25) 2-7/8( 73.4) Cut out hole 1 2-1/14(57) 2-7/32(56) 7-27/32(199) 13-27/32(352) 13-3/16(335) 19/32~1-15/32(15~37) 22-11/16~24-13/32(576~6) Ceiling hole 19/32~1-15/32(15~37) 3-7/16(87) 2-19/32(66) 4-3/4(121) 3-21/32(93) Refrigerant pipe (gas) Refrigerant pipe (liquid) 1-1/2~2-9/32(38~58) Suspension bolt lower edge 21/32(17) 7-15/16(2) Terminal block 9-1/16(23) Grille Ceiling surface Drain pipe VP-25 connection (O.D. 1-1/4( 32)) Suspension bolt M1 or W3/8 7-19/32(193) 8-3/16(8) 9-1/4(235) +3/16 +5 (27 ) 25/32() 1-1/16 Wiring entry 7-5/32(182) 1-7/8(48) 25-19/32(65) 11-27/32(31) Air outlet hole 2-5/32(55) 1-3/8(35) V/M 25-19/32(65) 11-27/32(31) Air outlet hole Brand label V/M Grille Drain hole Auto vane 14-27/32(377) Air intake hole Models SLZ-KA9NA SLZ-KA12NA SLZ-KA15NA Refrigerent pipe (liquid) 1/4 inch ( 6.35mm) 1/4 inch ( 6.35mm) 1/4 inch ( 6.35mm) Refrigerent pipe (gas) 3/8 inch ( 9.52mm) 3/8 inch ( 9.52mm) 1/2 inch ( 12.7mm) V/M 14-27/32(377) Air intake hole 1-3/8(35) 2-5/32(55) V/M Air intake grille Vane motor 16 Mitsubishi Electric US, Inc.
DIMENSIONS: SUZ-KA15NA 134 Satellite Boulevard. Suwanee, GA 324 Toll Free: 8-433-4822 www.mehvac.com FORM# SLZ-KA15NA - SUZ-KA15NA - 164 16 Mitsubishi Electric US, Inc.
SUBMITTAL DATA: SEZ-KD9NA & SUZ-KA9NA............... 9, BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule No.: GENERAL FEATURES Horizontal-ducted indoor unit for concealed Ultra thin body: 7-7/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" Air filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: SEZ-KD9NA Outdoor Unit: SUZ-KA9NA OPTIONAL ACCESSORIES Indoor Unit Filter Box with MERV 8 Filters (FBL1-1) Bottom Return Plate (BRP-1) Outdoor Unit Drain Socket (MAC-86DS) Drain Pan Heater (MAC-64BH-U) Three-pole Disconnect Switch (TAZ-MS33) Air Outlet Guide (MAC-856SG) Mounting Base (DSD-4N) Mounting Pad (ULTRILITE1) Wall-mounting Brackets (CWMB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21MAA) M-NET Control Adapter (MAC-399IF) Remote Temperature Sensor (M21-JKO-37) Hand-held Wireless Remote Controller (PAR-FL32MA; req.par-fa32ma-e) Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA-E) Lockdown Bracket for Hand-held Controller (RCMKP1CB) Cooling* Rated Capacity....8,1 Btu/h Capacity Range...3,8-1,9 Btu/h SEER... 15. Total Input....67 W Heating at 47 F* Rated Capacity....1,9 Btu/h Capacity Range...4,8-14,1 Btu/h HSPF... 1. Total Input....1, W Heating at 17 F* Rated Capacity....6,7 Btu/h Rated Total Input...81 W Maximum Capacity....6,7 Btu/h Maximum Total Input...1, W *Rating Conditions (Cooling)-Indoor: 8ºF(27ºC)DB, 67ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 75ºF(24ºC)WB. (Heating at 47ºF) - Indoor: 7ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 17ºF) - Indoor: 7ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 17ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 23V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size.... 15 A OPERATING CONDITIONS Indoor Intake Air Temp. Outdoor Intake Air Temp. Maximum 9 F (32 C) DB, 73 F (23 C) WB 115 F (46 C) DB Cooling Minimum 67 F (19 C) DB, 57 F (14 C) WB 14 F (-1 C) DB Maximum 8 F (27 C) DB, 67 F (19 C) WB 75 F (24 C) DB, 65 F (18 C) WB Heating Minimum 7 F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC. Voltage Indoor - Outdoor S1-S2...AC 8 / 23V Indoor - Outdoor S2-S3...DC 12-24V Indoor Unit MCA...1 A Fan Type x Quantity...Sirocco Fan x 2 Fan Motor Type... Direct-driven DC Brushless Motor Fan Motor Output...96 W Fan Motor...51 F.L.A. Airflow (Lo - Med - Hi).... 194-247 - 317 Dry CFM 174-222 - 285 Wet CFM Air Filter...Polypropylene Honeycomb External Static Pressure....2 -.6 -.14 -."WG Sound Pressure Level (Lo - Med - Hi)...23-26 - 3 db(a) DIMENSIONS UNIT INCHES / MM W 31-1/8 / 79 D 27-9/16 / 7 H 7-7/8 / Weight....42 lbs. / 19 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven MCA...12 A MOCP....15 A Fan Motor...5 F.L.A. Sound Pressure Level Cooling...46 db(a) Heating...5 db(a) DIMENSIONS INCHES / MM W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...66 lbs. / 3 kg External Finish... Munsell No. 3Y 7.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...3/8" / 9.52 mm Liquid Side....1/4" / 6.35 mm Max. Refrigerant Pipe Length.... 65' / 19 m Max. Refrigerant Pipe Height Difference... 4' / 12 m Connection Method...Flared
SEZ-KD9NA INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW CHARTS INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW SEZ-KD9NA (External static pressure.2[in.wg](5pa)) 8/23V 6Hz 4 [.16] SEZ-KD9NA (External static pressure.6[in.wg](15pa)) 8/23V 6Hz 5 [.] 3 [.12] [.8] 1 [.4] 4 [.16] 3 [.12] [.8] 1 [.4] 4 5 6 7 8 9 1 [141] [176] [212] [247] [282] [318] [353] 4 5 6 7 8 9 1 [141] [176] [212] [247] [282] [318] [353] SEZ-KD9NA (External static pressure.14[in.wg](35pa)) 8/23V 6Hz 8 [.32] 7 [.28] 6 [.24] 5 [.] 4 [.16] 3 [.12] [.8] 1 [.4] 4 5 6 7 8 9 1 [141] [176] [212] [247] [282] [318] [353] SEZ-KD9NA (External static pressure.[in.wg](5pa)) 8/23V 6Hz 8 [.32] 7 [.28] 6 [.24] 5 [.] 4 [.16] 3 [.12] [.8] 1 [.4] 4 5 6 7 8 9 1 [141] [176] [212] [247] [282] [318] [353] 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC.
DIMENSIONS: SEZ-KD9NA 345(13-19/32) Drain pipe(o.d.ø32(1-1/4)) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X3(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 12(1/2) 37(1-15/32) 1(3-15/16) 157.5(6-7/32) 37(1-15/32) 25(1) 57(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) Air outlet Air inlet A N B (Suspension bolt pitch) C M 88(3-15/32) 88(3-15/32) H 1(3-15/16)XJ=K 1(3-15/16) 57(2-1/4) Drain pipe(o.d.ø32(1-1/4)) 15(Duct) (5-29/32) (13/16) 3(1-3/16) 23(29/32) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 23(29/32) 1(13/32) 7 (2-25/32) 27(1-21/32) 2 Refrigerant piping flare connection (liquid) 7(27-9/16) 677(26-21/32) Control box 12(4-1/32) 17(6-23/32) 9 (3-9/16) (7-7/8) 23(29/32) Knockout hole ø27(1-3/32) (Indoor/outdoor connecting line) Knockout hole ø27(1-3/32) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) Drain pipe(o.d.ø32(1-1/4)) (Spontaneous draining) (13/16) 12(1/2) Air filter Note2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) (17-23/32) 45 777 (17-23/32) (3-19/32) 175±5(6-29/32±7/32) (Actual length) Access door (11-13/16) More than 3 Required space for service and maintenance Less than 3 (11-13/16) Less than 55 (21-21/32) More than 1 (13/32) More than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface Access door Make the access door at the appointed position properly for service maintenance. Model A B C D SEZ-KD9NA 7 752 798 66 (27-9/16) (29-5/8) (31-7/16) (26) SEZ-KD12NA 9 952 998 86 (35-7/16) (37-1/2) (39-5/16) (33-7/8) SEZ-KD15NA F G 6 8 (23-5/8) (31-1/2) H 66 (26) 8 1 86 (31-1/2) (39-3/8) (33-7/8) SEZ-KD18NA 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (47-3/16) (41-3/4) 11 (39-3/8) (47-1/4) (41-3/4) 9 Note1.Use M1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for SEZ-KD15NA model,which has 3 fans. SEZ-KD9,12NA models have 2 fans. SEZ-KD18NA models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 7 9 J 5 7 K 5 (19-11/16) 7 (27-9/16) 9 (35-7/16) L 16 24 M 839 (33-1/16) 139 (4-29/32) 1239 (48-25/32) N 79 (31-1/8) 99 (39) 119 (46-7/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.7(1/2) 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC.
DIMENSIONS: SUZ-KA9NA FORM# SEZ-KD9NA & SUZ-KA9NA - 118 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC. 34 Lawrenceville Suwanee Rd Suwanee, GA 324 Tele: 678-376-29 Fax: 8-889-994 Toll Free: 8-433-4822 (#3) www.mehvac.com
SUBMITTAL DATA: SEZ-KD15NA & SUZ-KA15NA.............. 15, BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEMS Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: Schedule No.: GENERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: 7-7/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" Air filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control Automatic fan speed control Auto restart following a power outage ed warranty: five years on parts/defects; seven years on compressors Indoor Unit: SEZ-KD15NA Outdoor Unit: SUZ-KA15NA OPTIONAL ACCESSORIES Indoor Unit Filter Box with MERV 8 Filters (FBL1-2) Bottom Return Plate (BRP-2) Outdoor Unit Drain Socket (MAC-86DS) Drain Pan Heater (MAC-64BH-U) Three-pole Disconnect Switch (TAZ-MS33) Air Outlet Guide (MAC-856SG) Mounting Base (DSD-4N) Mounting Pad (ULTRILITE1) Wall-mounting Brackets (CWMB1) Controller Options Wall-mounted Wired Remote Controller (PAR-21MAA) M-NET Control Adapter (MAC-399IF) Remote Temperature Sensor (M21-JKO-37) Hand-held Wireless Remote Controller (PAR-FL32MA;req.PAR-F 32MA-E) Wireless Signal Receiver PAR-FA32MA (for PAR-FL32MA-E) Lockdown Bracket for Hand-held Controller (RCMKP1CB) Cooling* Rated Capacity....14,1 Btu/h Capacity Range...3,8-17, Btu/h SEER... 15.5 Total Input....1,17 W Heating at 47 F* Rated Capacity....18, Btu/h Capacity Range...4,8-21,1 Btu/h HSPF... 1. Total Input....1,5 W Heating at 17 F* Rated Capacity....11,9 Btu/h Rated Total Input...1, W Maximum Capacity....11,9 Btu/h Maximum Total Input...1,65 W *Rating Conditions (Cooling)-Indoor: 8ºF(27ºC)DB, 67ºF(19ºC)WB; Outdoor: 95ºF(35ºC)DB, 75ºF(24ºC)WB. (Heating at 47ºF) - Indoor: 7ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB. (Heating at 17ºF) - Indoor: 7ºF (21ºC) DB, 6ºF (16ºC) WB; Outdoor: 17ºF (-8ºC) DB, 15ºF (-9ºC) WB. Electrical Requirements Power Supply...8 / 23V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size.... 15 A OPERATING CONDITIONS Indoor Intake Air Temp. Outdoor Intake Air Temp. Maximum 9 F (32 C) DB, 73 F (23 C) WB 115 F (46 C) DB Cooling Minimum 67 F (19 C) DB, 57 F (14 C) WB 14 F (-1 C) DB Maximum 8 F (27 C) DB, 67 F (19 C) WB 75 F (24 C) DB, 65 F (18 C) WB Heating Minimum 7 F (21 C) DB, 6 F (16 C) WB -4 F (- C) DB, -5 F (-21 C) WB Voltage Indoor - Outdoor S1-S2...AC 8 / 23V Indoor - Outdoor S2-S3... DC 12-24V Indoor Unit MCA...1 A Fan Type x Quantity...Sirocco Fan x 3 Fan Motor Type... Direct-driven DC Brushless Motor Fan Motor Output...96 W Fan Motor...74 F.L.A. Airflow (Lo - Med - Hi).... 353-441 - 529 Dry CFM 317-396 - 476 Wet CFM Air Filter...Polypropylene Honeycomb External Static Pressure....2 -.6 -.14 -."WG Sound Pressure Level (Lo - Med - Hi)...3-34 - 37 db(a) DIMENSIONS UNIT INCHES / MM W 39 / 99 D 27-9/16 / 7 H 7-7/8 / Weight....54 lbs. / 24 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven Twin Rotary MCA...12 A MOCP....15 A Fan Motor...5 F.L.A. Sound Pressure Level Cooling...49 db(a) Heating...51 db(a) DIMENSIONS INCHES / MM W 31-1/2 / 8 D 11-1/4 / 285 H 21-5/8 / 55 Weight...8 lbs. / 36 kg External Finish... Munsell No. 3Y 7.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12.7 mm Liquid Side....1/4" / 6.35 mm Max. Refrigerant Pipe Length.... 65' / 19 m Max. Refrigerant Pipe Height Difference... 4' / 12 m Connection Method...Flared 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC.
SEZ-KD15NA INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW CHARTS SEZ-KD15NA (External static pressure.2[in.wg](5pa)) 8/23V 6Hz 4 [.16] SEZ-KD15NA (External static pressure.6[in.wg](15pa)) 8/23V 6Hz 5 [.] 3 [.12] [.8] 1 [.4] 4 [.16] 3 [.12] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [53] [565] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [53] [565] SEZ-KD15NA (External static pressure.14[in.wg](35pa)) 8/23V 6Hz 8 [.32] 7 [.28] 6 [.24] 5 [.] 4 [.16] 3 [.12] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [53] [565] SEZ-KD15NA (External static pressure.[in.wg](5pa)) 8/23V 6Hz 8 [.32] 7 [.28] 6 [.24] 5 [.] 4 [.16] 3 [.12] [.8] 1 [.4] 8 9 1 11 12 13 14 15 16 [282] [318] [353] [388] [424] [459] [494] [53] [565] 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC.
DIMENSIONS: SEZ-KD15NA 345(13-19/32) Drain pipe(o.d.ø32(1-1/4)) (Emergency draining) Unit : mm(in.) 159(6-9/32) 15(19/32) 2XE-ø2.9(1/8) Suspension bolt hole 4-14X3(9/16X1-3/16) Slot L-ø2.9(1/8) (13/16) 12(1/2) 37(1-15/32) 1(3-15/16) 157.5(6-7/32) 37(1-15/32) 25(1) 57(2-1/4) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) Air outlet Air inlet A N B (Suspension bolt pitch) C M 88(3-15/32) 88(3-15/32) H 1(3-15/16)XJ=K 1(3-15/16) 57(2-1/4) Drain pipe(o.d.ø32(1-1/4)) 15(Duct) (5-29/32) (13/16) 3(1-3/16) 23(29/32) 1 25(1) (3-15/16) 116 (4-19/32) 2X2-ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 23(29/32) 1(13/32) 7 (2-25/32) 27(1-21/32) 2 Refrigerant piping flare connection (liquid) 7(27-9/16) 677(26-21/32) Control box 12(4-1/32) 17(6-23/32) 9 (3-9/16) (7-7/8) 23(29/32) Knockout hole ø27(1-3/32) (Indoor/outdoor connecting line) Knockout hole ø27(1-3/32) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) Drain pipe(o.d.ø32(1-1/4)) (Spontaneous draining) (13/16) 12(1/2) Air filter Note2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) (17-23/32) 45 777 (17-23/32) (3-19/32) 175±5(6-29/32±7/32) (Actual length) Access door (11-13/16) More than 3 Required space for service and maintenance Less than 3 (11-13/16) Less than 55 (21-21/32) More than 1 (13/32) More than (13/16) Drain hose (I.D.ø32(1-1/4)) <accessory> Ceiling surface Access door Make the access door at the appointed position properly for service maintenance. Model A B C D SEZ-KD9NA 7 752 798 66 (27-9/16) (29-5/8) (31-7/16) (26) SEZ-KD12NA 9 952 998 86 (35-7/16) (37-1/2) (39-5/16) (33-7/8) SEZ-KD15NA F G 6 8 (23-5/8) (31-1/2) H 66 (26) 8 1 86 (31-1/2) (39-3/8) (33-7/8) SEZ-KD18NA 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (47-3/16) (41-3/4) 11 (39-3/8) (47-1/4) (41-3/4) 9 Note1.Use M1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for SEZ-KD15NA model,which has 3 fans. SEZ-KD9,12NA models have 2 fans. SEZ-KD18NA models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 7 9 J 5 7 K 5 (19-11/16) 7 (27-9/16) 9 (35-7/16) L 16 24 M 839 (33-1/16) 139 (4-29/32) 1239 (48-25/32) N 79 (31-1/8) 99 (39) 119 (46-7/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.7(1/2) 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC.
DIMENSIONS: SUZ-KA15NA FORM# SEZ-KD15NA & SUZ-KA15NA - 118 11 MITSUBISHI ELECTRIC & ELECTRONICS, INC. 34 Lawrenceville Suwanee Rd Suwanee, GA 324 Tele: 678-376-29 Fax: 8-889-994 Toll Free: 8-433-4822 (#3) www.mehvac.com
Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction System Designation: **APPLIES TO INDOOR UNIT: SEZ-KD18NA4 SEZ-KD18NA4.TH SEZ-KD18NAR1.TH SEZ-KD18NA4R1.TH SUBMITTAL DATA: SEZ-KD18NA4** & SUZ-KA18NA 18, BTU/H HORIZONTAL-DUCTED HEAT-PUMP SYSTEMS Schedule No.: M-SERIES Indoor Unit: SEZ-KD18NA4** Outdoor Unit: SUZ-KA18NA GENERAL FEATURES Horizontal-ducted indoor unit for concealed applications Ultra thin body: 7-7/8" high Built-in drain mechanism for condensate removal; lifts to 21-11/16" Air filter is included with indoor unit Quiet operation as low as 23 dba Indoor unit powered from outdoor unit using A-Control AUTO fan speed control Automatic restart following a power outage ed warranty: five years parts and seven years compressors ACCESSORIES Indoor Unit Filter Box with MERV 8 Filters (FBL1-3) Bottom Return Plate (BRP-3) Outdoor Unit Drain Socket (MAC-811DS) Drain Pan Heater (MAC-641BH-U) Three-pole Disconnect Switch (TAZ-MS33) Air Outlet Guide (MAC-856SG) Mounting Base (DSD-4N) Mounting Pad (ULTRILITE1) Wall-mounting Brackets (CWMB1) Controller Options Wireless Wall-mounted Remote Controller Kit (MHK1)* Portable Controller (MCCH1)* Outdoor Air Sensor (MOS1)* *See Submittal for information on each option. Wired Wall-mounted Controller (PAR-21MAAU) System Control Interface (MAC-333IF) Remote Temperature Sensor (M21-JKO-37) Hand-held Wireless Remote Controller (PAR-FL32MA; eq.par-fa32ma-e) Wireless Signal Receiver Module PAR-FA32MA (for PAR-FL32MA) Lockdown Bracket for Hand-held Controller (RCMKP1CB) 13 Mitsubishi Electric US, Inc.
SPECIFICATIONS: SEZ-KD18NA4** & SUZ-KA18NA Cooling* Rated Capacity....17, Btu/h Capacity Range...3,8-19, Btu/h SEER... 17.5 Total Input....1,38 W Heating at 47 F* Rated Capacity....21,6 Btu/h Capacity Range...4,8-24,9 Btu/h HSPF... 1. Total Input....1,7 W Heating at 17 F* Rated Capacity....13,1 Btu/h Rated Total Input...1,35 W Maximum Capacity**...13,1 Btu/h Maximum Total Input...1,83 W * Rating Conditions per AHRI Standard Cooling Indoor: 8º F (27º C) DB / 67º F (19º C) WB Cooling Outdoor: 95º F (35º C) DB / 75º F (24º C) WB Heating at 47ºF Indoor: 7º F (21º C) DB / 6º F (16º C) WB Heating at 47ºF Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F Indoor: 7º F (21º C) DB / 6º F (16º C) WB Heating at 17º F Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB ** Maximum Capacity is at full speed and performance for INVERTER-driven System. Electrical Requirements Power Supply...8 / 23V, 1-Phase, 6 Hz Recommended Fuse/Breaker Size.... 15 A OPERATING CONDITIONS Maximum Minimum Maximum Minimum Heating Cooling Indoor Intake Air Temp. 9 F (32 C) DB 73 F (23 C) WB 67 F (19 C) DB 57 F (14 C) WB 8 F (27 C) DB 67 F (19 C) WB 7 F (21 C) DB 6 F (16 C) WB Outdoor Intake Air Temp. 115 F (46 C) DB 14 F (-1 C) DB 75 F (24 C) DB 65 F (18 C) WB -4 F (- C) DB -5 F (-21 C) WB Voltage Indoor - Outdoor S1-S2...AC 8 / 23V Indoor - Outdoor S2-S3...DC ±24V Indoor Unit MCA...1 A Blower Type x Quantity....Sirocco Fan x 4 Blower Motor Type... Direct-driven DC Brushless Motor Blower Motor Output....96 W Blower Motor (ECM)....74 F.L.A. Airflow (Lo - Med - Hi).... 423-529 - 635 Dry CFM 381-476 - 572 Wet CFM Air Filter...Polypropylene Honeycomb External Static Pressure....2 -.6 -.14 -."WG Sound Pressure Level (Lo - Med - Hi)...3-34 - 38 db(a) DIMENSIONS UNIT INCHES / MM W 46-7/8 / 1,19 D 27-9/16 / 7 H 7-7/8 / Weight....62 lbs. / 28 kg External Finish...Galvanized-steel Sheets Field Drainpipe Size O.D.....1-1/4" / 32 mm Outdoor Unit Compressor...DC Inverter-driven Twin Rotary MCA...14 A MOCP....15 A Fan Motor (ECM)...93 F.L.A. Sound Pressure Level Cooling...54 db(a) Heating...56 db(a) DIMENSIONS INCHES / MM W 33-1/16 / 84 D 13 / 33 H 33-7/16 / 85 Weight...119 lbs. / 54 kg External Finish... Munsell No. 3Y 7.8 / 1.1 Refrigerant Type...R41A Refrigerant Pipe Size O.D. Gas Side...1/2" / 12.7 mm Liquid Side....1/4" / 6.35 mm Max. Refrigerant Pipe Length.... 1' / 3 m Max. Refrigerant Pipe Height Difference... 5' / 15 m Connection Method...Flared Notes: 13 Mitsubishi Electric US, Inc.
SEZ-KD18NA4** INDOOR FAN PERFORMANCE AND CORRECTED AIR FLOW CHARTS SEZ-KD18NA4** (Exter nal static pressure.2[in.wg](5p 4 [.16] a)) 8/23V 6Hz SEZ-KD18NA4** (Exter nal static pressure.6[in.wg](15p 5 [.] a)) 8/23V 6Hz 3 [.12] [.8] 1 [.4] 4 [.16] 3 [.12] [.8] 1 [.4] 9 1 11 12 13 14 15 16 17 18 19 [318] [353] [388] [424] [459] [494] [53] [565] [6] [636] [671] 9 1 11 12 13 14 15 16 17 18 19 [318] [353] [388] [424] [459] [494] [53] [565] [6] [636] [671] SEZ-KD18NA4** (Exter nal static pressure.14[in.wg](35p 8 [.32] 7 [.28] 6 [.24] 5 [.] 4 [.16] 3 [.12] [.8] 1 [.4] a)) 8/23V 6Hz SEZ-KD18NA4** (Exter nal static pressure.[in.wg](5p 8 [.32] 7 [.28] 6 [.24] 5 [.] 4 [.16] 3 [.12] [.8] 1 [.4] a)) 8/23V 6Hz 9 1 11 12 13 14 15 16 17 18 19 [318] [353] [388] [424] [459] [494] [53] [565] [6] [636] [671] 9 1 11 12 13 14 15 16 17 18 19 [318] [353] [388] [424] [459] [494] [53] [565] [6] [636] [671] 13 Mitsubishi Electric US, Inc.
DIMENSIONS: SEZ-KD18NA4** 159(6-9/32) 15(19/32) 2XE- ø2.9(1/8) 345(13-19/32) Drain pipe(o.d. ø32(1-1/4)) (Emergency draining) Suspension bolt hole 4-14X3(9/16X1-3/16) Slot L- ø2.9(1/8) (13/16) 12(1/2) 37(1-15/32) 1(3-15/16) 157.5 (6-7/32) 37(1-15/32) Unit : mm(in.) D (Duct) 1(3-15/16)X(E-1)=F 1(3-15/16) Air outlet Air inlet 25(1) A N B (Suspension bolt pitch) C M 88(3-15/32) 88(3-15/32) H 57(2-1/4) 1(3-15/16)XJ=K 1(3-15/16) Drain pipe(o.d. ø32(1-1/4)) 15(Duct) (5-29/32) (13/16) 3(1-3/16) 23(29/32) 1 25(1) (3-15/16) 57(2-1/4) 116 (4-19/32) 2X2- ø2.9(1/8) 1 Refrigerant piping flare connection (gas) 1(13/32) 49 625(Suspension bolt pitch) (1-15/16) (24-5/8) 23(29/32) 1(13/32) 7 (2-25/32) 27(1-21/32) 2 Refrigerant piping flare connection (liquid) 7(27-9/16) 677(26-21/32) Control box 12(4-1/32) 17(6-23/32) 9 (3-9/16) (7-7/8) 23(29/32) Knockout hole ø 27(1-3/32) (Indoor/outdoor connecting line) Knockout hole ø 27(1-3/32) (Remote controller transmission line) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) Drain pipe(o.d. ø32(1-1/4)) (Spontaneous draining) (13/16) 12(1/2) Air filter Note2 5(1-31/32) 5(1-31/32) G 45 5 ~ 15 (1-31/32 ~ 5-29/32) (17-23/32) 45 777 (17-23/32) (3-19/32) 175±5(6-29/32 ±7/32) (Actual length) Access door (11-13/16) More than 3 Required space for service and maintenance Less than 3 (11-13/16) Less than 55 (21-21/32) More than 1 (13/32) Drain hose (I.D. ø32(1-1/4)) <accessory> More than (13/16) Ceiling surface Access door Make the access door at the appointed position properly for service maintenance. Model A B C D SEZ-KD9NA4** 7 752 798 66 (27-9/16) (29-5/8) (31-7/16) (26) SEZ-KD12NA4** 9 952 998 86 (35-7/16) (37-1/2) (39-5/16) (33-7/8) SEZ-KD15NA4** F G 6 8 (23-5/8) (31-1/2) H 66 (26) 8 1 86 (31-1/2) (39-3/8) (33-7/8) SEZ-KD18NA4** 11 1152 1198 16 1 1 16 (43-5/16) (45-3/8) (47-3/16) (41-3/4) 11 (39-3/8) (47-1/4) (41-3/4) 9 Note1.Use M1 screw for the suspension bolt (field supply). 2.Keep the service space for the maintenance at the bottom. 3.This chart indicates for SEZ-KD15NA4** model,which has 3 fans. SEZ-KD9,12NA4** models have 2 fans. SEZ-KD18NA4** models have 4 fans. 4.In case an inlet duct is used,remove the air filter(supply with the unit), then install the filter(field supply) at suction side. E 7 9 J 5 7 K 5 (19-11/16) 7 (27-9/16) 9 (35-7/16) L 16 24 M 839 (33-1/16) 139 (4-29/32) 1239 (48-25/32) N 79 (31-1/8) 99 (39) 119 (46-7/8) mm(in.) 1 Gas pipe 2 Liquid pipe ø9.52(3/8) ø6.35(1/4) ø12.7(1/2) 13 Mitsubishi Electric US, Inc.
DIMENSIONS: SUZ-KA18NA FORM# SEZ-KD18NA4** & SUZ-KA18NA - 134 13 Mitsubishi Electric US, Inc. 134 Satellite Boulevard Suwanee, GA 324 Tele: 678-376-29 Fax: 8-889-994 Toll Free: 8-433-4822 www.mehvac.com