TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

Similar documents
Air-Cooled Condensers

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Advance Release September 2009

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

AIR HANDLER SPECIFICATION

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Product Chillers A P P L I C AT I O N S

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SeasonMaker ThinLine Fan-coil Units

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

SeasonMaker ThinLine Fan-coil Units

SSL & SBS Engineering Guide

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SECTION FAN COIL UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

Air-Cooled Condensers

SECTION AIR HANDLING UNIT

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Ultra-Safe EXP Unit Heater

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

FE1 Explosion-Proof Electric Air Heaters

1.1 This section applies to air handling units for HVAC Systems.

Product Specifications. Vertical Floor Consoles By First Co.

Liebert Air-Cooled Fin/Tube Condensers

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

FX5 Series Explosion-Proof Electric Air Heaters

AIR COOLED PACKAGED CHILLER

.2 Section Waste Management and Disposal.

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

Construction Standards Page

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

Cabinet Unit Heaters Steam / Hot Water

Brasch Hazardous Location Unit Heaters

AIR COOLED CONDENSING UNITS IMPORTANT DESIGN FEATURES

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

PRODUCT CATALOG BLOWER COILS.

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

MAC N-407 Air-Cooled Chiller

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

Chilled Water DOAS Fan Powered Terminal Units

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

FCC Fan-Coil Units High-Performance, Vertical

MACH N-407 Heat Pump Air-Cooled Chiller

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

ULTRA-SAFE Explosion-proof Duct Heaters

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

MAC-120HE-03 Air-Cooled Chiller

Custom Duct Heaters. Special Applications

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

SMALL AIR COOLED CONDENSERS

T P A 120 S 4 S N 1 Y

Direct Fired Heater Model AD Specification

Modular Heating & Ventilating Unit Model IGX-HV

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Modular Supply Make-Up Air Unit

KIC Air Curtains. Technical Guide

A. Codes and Standards that are Standard at the University:

catalog CDV Fan-Coil Units High-Performance, Vertical

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

30GT FLOTRONIC AIR-COOLED CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SECTION AIR COOLED WATER CHILLERS

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

LOW PROFILE UNIT COOLER

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PACKAGE AIR CONDITIONER

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

TECHNICAL SPECIFICATIONS

CENTRAL SPLIT UNIT UNIC

ULTRA-SAFE Explosion-proof Duct Heaters

GUIDE SPECIFICATIONS - 48HC*D17-28

Transcription:

TABLE OF CONTENTS Page FCV Nomenclature 3 FCV Features & Construction 4 FCV Engineering Specifications 5 FCV Fan/Coil Data 6 FCV Unit Weights and Volumes 7 FCV Fan and Motor Data 8-9 Dimensions 10-14 Standard and Optional Leg Dimensions and Connection Sizes 15

FCV Nomenclature MODEL NUMBER IDENTIFICATION FCV-03-S-30-4-214-017-C-2 FC Horiz/Vert No. of Fans Single/Double Voltage B = 208-1-60 C = 208-230-3-60 D = 460-3-60 Fan Diameter Circuits 4 = 1/2, 5 = 5/8 Tubes Rows/FPI CONNECTION SIZES * * All connections are MPT unless specified otherwise. 3

FCV Features and Construction STANDARD FEATURES COILS 1/2 OD copper tubes,.017 wall thickness or 5/8 O.D. copper tubes,.020 wall thickness. Aluminum fins -.006 thick - 6 fins/inch to 14 fins/inch. Galvanized steel casing with aluminum tube sheets. FAN SECTION Aluminum fan blades with painted steel hubs. Motors - open type 6 pole energy efficient - 1140 RPM. Each module fully baffled. Motors mounted on 12 ga. motor rails. CONTROL PANEL Weatherproof enclosure with all motor leads terminated at panel. GENERAL CONSTRUCTION Galvanized steel frame and cabinet - 16 ga. cabinet, 12 ga. rails and legs, 12 ga. motor rails. Telescoping legs mounted on FCV-02S-26 and larger units. OPTIONAL FEATURES COILS Upgrade fin thickness to.010 thick aluminum Substitute.006 thick copper fins in lieu of aluminum Epoxy coat or phenolic coat coils CONTROL PANEL Supply fan cycling controls to include aquastat & control transformer. Control circuit toggle switches or terminal blocks. Mounted disconnect switch Motor fusing UNIT CONFIGURATION Single fan-width units: up to three fans can be constructed for horizontal air flow. 4

FCV Features and Construction TYPICAL ENGINEERING SPECIFICATIONS GENERAL USA Coil & Air model FCV units shall be furnished as per the following specifications in vertical airflow (FCV). Units shall be ETL and ETLc listed. UNIT CABINETS Housing shall be constructed of heavy-gauge galvanized steel for maximum rigidity and corrosion protection. All multiple fan units shall have individual fan sections, separated by full width baffles to prevent air bypass and provide additional casing rigidity. Unit sizes FCV-02S-26 and larger shall be provided with lifting eyes for rigging. Unit sizes FCV-02S-26 through FCV12D-30 shall be provided with 12 gauge galvanized steel telescoping legs factorymounted for convenient unit installation. FLUID COIL Coils shall be constructed of seamless 1/2-inch or 5/8-inch O.D. copper tubing on a staggered pattern. All tubes shall be mechanically expanded into full-collared plate-type aluminum (or optional copper) fins for permanent contact and maximum heat transfer efficiency. All coils shall be leak tested at 550 psig with dry nitrogen. FANS Fans shall be propeller type with aluminum blades and painted steel hubs. Fans shall be dynamically balanced and factory run tested before shipping. Fans shall have dual set screws spaced 90 degrees apart which seat onto one flat and one keyway on the shafts. FAN GUARDS Fan guards shall be heavy gauge steel wire with vinyl coating for maximum protection and attractive appearance. FAN MOTORS Fan motors shall be heavy duty PSC or three phase open drip-proof with built-in overload protection and permanently lubricated ball bearings. All motors shall have a rigid base mounted to 12 gauge galvanized steel rails. Motors shall be factory wired with leads terminating in a weather-tight enclosure. 5

FCV - Fan/Coil Data FCV SINGLE AND DOUBLE FAN-WIDTH UNITS 6

FCV/FCH Unit Weights and Volumes UNIT WEIGHTS AND VOLUMES 7

Fan and Motor Data FAN AND MOTOR DATA - SINGLE FAN-WIDTH UNITS * 8 *All Readings 10 ft. from center of unit.

Fan and Motor Data FAN AND MOTOR DATA - DOUBLE FAN-WIDTH UNITS * *All Readings 10 ft. from center of unit. 9

Dimensions SINGLE FAN UNITS FCV-01S-18-4-108 & FCV-01S-18-4-208 END VIEW SIDE VIEW SINGLE FAN UNITS FCV-01S-22-4-210 & FCV-01S-22-4-310 END VIEW SIDE VIEW SINGLE FAN UNITS FCV-02S-22-4-208 THRU FCV-02S-22-4-410 END VIEW SIDE VIEW 10

Dimensions SINGLE FAN UNITS FCV-02S-26-4-208 THRU FCV-02S-30-4-414 SINGLE UNITS FCV-03S-30-4-310 THRU FCV-03S-30-4-412 SINGLE UNITS FCV-04S-30-4-310 THRU FCV-04S-30-4-414 11

Dimensions SINGLE UNITS FCV-05S-30-4-314 THRU FCV-05S-30-4-414 SINGLE UNITS FCV-06S-30-4-410 THRU FCV-06S-30-4-414 12

Dimensions DOUBLE FAN UNITS FCV-04D-30-4-214 THRU FCV-04D-30-4-414 DOUBLE UNITS FCV-06D-30-4-214 THRU FCV-06D-30-4-414 DOUBLE UNITS FCV-08D-30-4-310 THRU FCV-08D-30-4-414 13

Dimensions DOUBLE UNITS FCV-10D-30-4-314 THRU FCV-10D-30-4-414 DOUBLE UNITS FCV-12D-30-4-410 THRU FCV-12D-30-4-414 14

Leg Dimensions and Connection Sizes STANDARD 18 LEG AND OPTIONAL 30 LEG DIMENSIONS CONNECTION SIZES* + MOTOR AMPS + All connections are MPT *Contact factory for exact location of connections on header. Some units may have split headers. 15