0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient Operation Hydrophilic Aluminum Fins Independent Dehumidification Optional Drain Pump Refrigerant Leak Detection R-40A HFC Refrigerant R40A Inverter Compressor Super Quiet ECO Function Anti Freezing Anti-Freezing Protection Easy Flexible Installation IAQ Efficient Anti-dust Filters 40~00 Pa Medium Static Pressures Wired Control Timer Functions High Temp. Protect High Temp. Protection Easy Fast Service & Maintenance Fresh Air Efficient Fans Wireless Control Restart Function Cold Draft Protection Washable Air Filter Slim Design Efficient Coils Fan Speed Min. Minutes Time Delay Defrost Protection Display Panel Inner Groove Copper Tubing Mode Durability Self diagnostic function
Quiet with Minimum Sound Level Patented centrifugal blower, elephant ear propeller, new heat exchangers, improved Air Management System (AMS), and quiet compressor. Statically and dynamically balanced fans for quiet operation. Minimum vibrations with strengthened sheet metal parts by finite element analysis. Comfort with Complete Control Functions Standard Smart Wired Controller with complete control functions built in the control system. Wired Controller can be fixed on the wall and avoid mislaying. It s mainly used for commercial zone and makes the control more convenient. Standard Smart LCD infrared wireless remote control with complete control functions built in the control system to ensure efficiency at all operating conditions. Optional Smart Link central Control to monitor from a center point, the operation of number of ducted indoor units in the same project site. This feature is particularly helpful in large office applications and hotels. fan speed which changes automatically the fan speed to high or medium or low fan speed by sensing the temperature difference between the room temperature and setting temperature. mode which changes automatically the operation mode and capacity output according to temperature difference between room temperature and setting temperature. Independent Dehumidification mode which dehumidifies the room efficiently, but not lower the temperature so obviously as cooling operation. ECO function for energy saving and comfortable healthy sleep which automatically changes fan speed to low speed and controls both setting and room temperatures. Programmable timer for easy on and off selection with energy savings including off timer, on timer, off/on timer and on/off timer functions. Follow Me function for smart wired control of comfortable temperature. With this technology, an efficient temperature sensor is built in the wired control just like the air conditioner is following wired control. Durability Anti-rust, weather proof and long life indoor unit sheet metal parts made of chemically treated and zinc coated ( galvanized ) sheet metal. Drain pan is designed to protect against rust, to minimize wet surface and residual water during off cycles and to inhibit bacteria growth that may cause smells. Anti-rust, weather proof and long life outdoor unit sheet metal parts made of chemically treated and zinc coated ( galvanized ) sheet metal. Powder painted casing of outdoor unit with prefect adhesion of highly resistant ployester paint 0-80 microns thick, which is electro-statically applied and baked at a temperature of 0 C. Optional coated aluminum fins of outdoor coil for coastal applications to protect against corrosion. Key Features Smart Link Complete Safety & Reliability Functions restart function with backup memory. When the power failure happenes during the operation of air conditioner, the microprocessor of the Printed Circuit Board will memorize the operation setting. After the power is recovered, the air conditioner operates automatically ( without remote control but after elapse of compressor safety time delay ), according to the previous operation settings. (three) minutes safety time delay between compressor turning off and turning on for compressor protection against cycling. Anti-freezing protection of indoor coil when the air conditioner is operating in cool mode with excessive dirt on the indoor coil and / or clogged air filters and / or low ambient temperature operation of cool mode. High temperature protection of outdoor coil when the air conditioner is operating in cool mode. This protection is only available for heat pump system. Cold draft protection when the air conditioner is operating in heat mode to prevent cold air blowing out at the beginning of heat mode which avoids the discomfort to the user. High temperature protection of indoor coil when the air conditioner is operating in heat mode. Defrost protection of outdoor coil when the air conditioner is operating in heat mode at very low ambient temperature. Smart self-diagnostic function for malfunctions detection for easy fast service and maintenance. Smart Refrigerant leak detection by sensitive sensors mounted on both indoor and outdoor coils for easy fast service and maintenance. reset internal thermal protector of indoor and outdoor fan motors to protect motor windings against excessive current. The components of both indoor and outdoor units comply with international standards of performance and safety. Min. Anti Freezing Hi Temp. Protect Cool Hi Temp. Protect Heat Motors Rev. (0) - 0
Ducted Split Systems Green Medium Static Pressure Heat Pump medium static pressure, slim line, ceiling concealed ducted split is the optimum air conditioning solution for places which require ceiling installation above false ceiling and minimum sound levels. Its slim profile and flexible installation make this system the best choice for residential and light commercial applications where the units are practically hidden from view. KEY FEATURES Healthy & Clean Indoor Air Quality (IAQ) Efficient anti dust washable aluminim air filters for clean and healthy air. IAQ SMART CONTROLS Wired room controller EFFICIENT, TROPICAL & QUIET OUTDOOR UNIT $ ( option ) Wireless Remote control The indoor unit is fitted with a fresh air knock out panel that can be utilized to introduce fresh air into the room. This helps prevent the build of stale air and enhances air quality in working environments and enclosed applications without natural fresh air supply. Modern Slim Design Compact invisible indoor unit with ultra slim profile and low height is just cm for sizes K-8K, 4.9 cm for sizes 0K-K and 0 cm for sizes 4K-48K-0K suitable for low false ceiling applications. Smart display panel shows control functions and also shows error code in case of a malfunction. Efficient Tropical Operation with Minimum Electrical Consumption works with the new R-40A refrigerant which increases its energy efficiency and does not degrade the ozone layer. Patented heat transfer and aerodynamics technologies to ensure prefect operation up to C outdoor ambient temperature for energy saving and low operating cost. Superior air distribution performance : Three fan speeds with external static pressure up to 40 ~ 00 Pa as per the model to satisfy air flow and static pressure requirements to suit various applications. Efficient Air Management System (AMS) leading to maximum air flow with minimum turbulence for minimum air resistance, smooth airflow and efficient operation. Carrier innovative outdoor axial fan technology for efficient operation with minimum air resistance and maximum air flow. R-40A HFC $ 40~00 Pa AMS Sizes : -8-4 Sizes : 0 - Sizes : 48-0 Carrier innovative double inlet, double width forward curved centrifugal blower technology driven by speeds high efficiency motor of low power consumption. www.carrierafrica.com Efficient indoor and outdoor coils with large heat transfer surfaces for minimum electrical consumption. Efficient trapeziform Inner groove copper tubing compared with traditional copper tubing, it allows more refrigerant flow, improvs heat exchange efficiency and lowers power consumption while keeping the same capacity output level. Precoated Hydrophilic Aluminum Fins of indoor coil to protect the coil against corrosion and to allow easy and quick removal of unrestricted condensate water between the coil fins to increase airflow, improve heat exchange efficiency and accelerate cooling process.
Key Features Easy Installation, Service and Maintenance (Cont.) The display panel can be installed on the false ceiling to show unit operation and error code. Easy removal of washable air filters for cleaning. Remote ON / OFF function provides more easy central control of ducted split system. Remote ON / OFF Easy accessibility to motors and fans of indoor unit for easy fast service and maintenance. motor Blower housing Remote system alarm function which required for some applications such as computer rooms for fast and easy service and maintenance. Bottom Panel Remote Alarm Smart self-diagnostic function for malfunctions detection through the leds of display panel for easy fast service and maintenance. Optional drain pump which can lift the condensate water up to cm upmost. Optional drain pump is factory installed. Smart Refrigerant leak detection by sensitive sensors mounted on both indoor and outdoor coils for easy fast service and maintenance. cm Rev. (0) - 0 ceiling
Ducted Split Systems Green Medium Static Pressure Key Features Easy Installation, Service and Maintenance Due to compact dimensions, low height and low weight, the installation of ducted indoor unit on the ceiling is faster and extremely easy. Slim Low Height Compact Dimensions & Light Weight Size Dimensions (cm) W H D Net Weight K 0 8..4 8K 88 4K 0K K 48K 0K Kg 0. 4.9.4 40. 0 0 8.4 4 cm or 4.9 cm or 0 cm Min. mm Drop - Ceiling Flexible two directions of air return : Back air return ( factory standard ) Bottom air return ( can be done at field ). Pre-Punched Fresh air intake built in the indoor unit from both sides to make air quality more healthy and more comfortable. Back Return Air Bottom Return Air Fresh air intake Indoor unit equipped with flange connections for both supply and return air ducts. www.carrierafrica.com
Wireless Remote Control ( option ) Display Of Remote Control 4 8 9 0 4 AUTO COOL DRY HEAT AUTO COOL DRY HEAT SET TEMP. TIMER ON OFF 4 8 FAN HIGH MED LOW Signal transmission indicator MODE indicator matic Cooling Dehumidification only Heating FAN Ventilation (fan only) ON / OFF indicator 4 SET TEMP. indicator Control Buttons MODE selection button AUTO - COOL - DRY - HEAT - FAN LOW MED FAN SPEED indicator FAN SPEED indicator LOW FAN SPEED indicator MED 4 Decrease temperature button The set temperature is decreased down to C. Increase temperature button The set temperature is increased up to 0 C. FAN selection button Low - Medium - High - fan speed HIGH AUTO 8 FAN SPEED indicator HIGH FAN SPEED indicator AUTO TIMER ON function indicator TIMER OFF function indicator FOLLOW ME function indicator ON/OFF button Air Direction function button * Vertical Air Flow Swing * 8 Sleep function button 9 TIMER ON function button 0 TIMER OFF function button My Mode function button to memorize the preferred settings 4 Note : Follow Me function button * Display function button TURBO function button * * This function does not work with this product but works with other products Rev. (0) - 0
Ducted Split Systems Green Medium Static Pressure Wired Room Controller POWER Button MODE Selection Button Display of Wired Room Controller POWER Temperature Selection Button Cool Dry 4 FAN SPEED Selection Button Heat Fan FOLLOW ME Button TIMER Button DELAY / DAY OFF Button 8 CONFIRM Button 9 BACK Button 0 COPY Button SU MO TU WE TH FR SA Week 4 Day On Off MODE TIMER SWING SWING DELAY/DAY OFF CONFIRM BACK FAN SPEED FOLLOW ME COPY 8 9 4 0 Operation Mode Indicator AUTO Mode Indicator Display of Wired Room Controller 4 Cool Dry COOL Mode Indicator DRY Mode Indicator Heating Mode Indicator Cool Heat Fan Dry 8 Fan FAN Mode Indicator Fan speed Indicator SU MO TU WE TH FR SA Week 4 Day On Off 9 Low Fan Speed Indicator 0 Medium Fan Speed Indicator www.carrierafrica.com 4 High Fan Speed Indicator Fan Speed Indicator Faceplate function indicator Follow me function indicator C / F indicator Temperature display 8 9 0 Lock indicator Room temperature indicator Clock display On/Off timer Timer display
Smart Self Diagnostic Function For Malfunction Detection Display of the indoor unit sizes 8-4-0--48-0 4 Touche d urgence Lorsqu on a perdu la télécommande, que celle-ci est endommagée ou que la batterie est à plat, la touche d urgence permet de faire fonctionner l unité. Led OPERATION ( fonctionnement ) * allumeé lorsque l unité fonctionne. Led TIMER ( temporisateur ) * allumeé en fonction temporisateur. 4 Led DEFROST / FAN ( dégivrage / ventilation ) Led DEFROST ( dégivrage ) : pour l unit à pompe à chaleur. Led FAN ( ventilation ) pour l unité à refroidissement seul. Led ALARM clignote lorsque le code défaut de l unit extérieure est identifiable. Récepteur des signaux envoyés par la télécommande Affichage Le code de défaut est identifiable par l affichage Self diagnostics sizes 8-4-0--48-0 The fault code is identifiable by the s and the fault code Malfunction Reason Model channel is abnormal The indoor / outdoor unit communication unit Temperature sensor air from the indoor unit Indoor coil temperature sensor of the indoor unit Outdoor unit coil temperature sensor EEPROM malfunction OPERATION TIMER DEF.FAN ALARM Malfunction Code E0 E E E E4 E Water-level alarm malfunction Outdoor unit low pressure malfunction The unit is switched off by remote control Defrost heater is active EE Ed Rev. (0) - 0 = Flash Hz = Flash Hz * = DEFROST (defrost) for the heat pump unit Led FAN ( FAN ) for cooling only unit.
Ducted Split Systems Green Medium Static Pressure Smart Self Diagnostic Function For Malfunction Detection Display of the indoor unit size 4 Touche d urgence Lorsqu on a perdu la télécommande, que celle-ci est endommagée ou que la batterie est à plat, la touche d urgence permet de faire fonctionner l unité. Led OPERATION ( fonctionnement ) * allumeé lorsque l unité fonctionne. Led TIMER ( temporisateur ) * allumeé en fonction temporisateur. 4 Led DEFROST / FAN ( dégivrage / ventilation ) Led DEFROST ( dégivrage ) : pour l unit à pompe à chaleur. Led FAN ( ventilation ) pour l unité à refroidissement seul. Led ALARM clignote lorsque le code défaut de l unit extérieure est identifiable. Récepteur des signaux envoyés par la télécommande Affichage Le code de défaut est identifiable par l affichage Self-diagnosis function of the indoor unit size The fault code is identifiable by the s and the fault code Malfunction Reason Temperature sensor air from the indoor unit Indoor coil temperature sensor of the indoor unit Outdoor unit coil temperature sensor Outdoor malfunction EEPROM malfunction OPERATION TIMER DEF.FAN ALARM Malfunction Code E0 E E E E www.carrierafrica.com Water-level alarm malfunction Protection against over current outdoor unit Protection against high temperature compressor Protection against over current outdoor unit The unit is switched off by remote control Defrost heater is active E P0 P = Flash Hz = Flash Hz * = DEFROST (defrost) for the heat pump unit Led FAN ( FAN ) for cooling only unit.
Technical Specifications System type Heat Pump System size K 8K 4K 0K K K 48K 0K Indoor unit model 4QSS0NS 4QSS08NS 4QSS04NS 4QSS00NS 4QSS0NS 4QSS0NT 4QSS048NT 4QSS00NT Outdoor unit model 8QUS0NS 8QUS08NS 8QUS04NS 8QUS00NS 8QUS0NS 8QUS0NT 8QUS048NT 8QUS00NT Cooling capacity kw... 8.9 0. 0. 4.0. Btu/hr 00 8000 000 0000 000 000 48000 000 Input power - Cooling W 0 900 800 00 800 800 00 00 Input current - Cooling A. 9... 8.. 9. 0.9 E.E.R. - Cooling Heating capacity W/W.....8.8..0 Btu/wh 9. 9.4 9.8 9.09 9.4 9.4 9. 8.8 kw.8..9 9..4.4..8 Btu/hr 000 9000 000 000 8000 8000 000 0000 Input power - Heating W 0 80 00 900 00 400 4400 00 Input current - Heating A.8.9..0... 9. C.O.P - Heating W/W.9.0.44..8...8 Indoor unit model 4QSS0NS 4QSS08NS 4QSS04NS 4QSS00NS 4QSS0NS 4QSS0NT 4QSS048NT 4QSS00NT Nominal air flow (high/med/low) ( @ rated external static pressure ) Indoor maximum external static pressure m /hr /48/400 90/0/0 0/0/9 00/00/000 800/400/00 800/400/00 00/80/400 00/80/400 cfm 9/8/ /4/9 //4 88//90 0/8/0 0/8/0 /09/8 /09/8 Pa 0 0 Range external static pressure Pa 0-0 0-0 0-80 0-00 0-00 0-00 0-0 0-0 Sound Pressure (high/med/low) db(a) 40// 40// 4/9/ 44/40/ 48/4/9 48/4/9 /48/4 /48/4 Net Dimensions (W H D) mm 00x0x 880x0x4 00x49x4 00x49x4 00x49x4 00x49x4 00x00x8 00x00x8 Weight Net Kg 9.. 0.8... 44. 4 Outdoor unit model 8QUS0NS 8QUS08NS 8QUS04NS 8QUS00NS 8QUS0NS 8QUS0NT 8QUS048NT 8QUS00NT Compressor type Rotary Rotary Rotary Rotary Scroll Scroll Scroll Scroll Rev. (0) - 0 Refrigerant type / Coupler R40A / Flare Sound pressure db(a) 9 4 Net Dimensions (W H D) mm 0xx00 0xx00 84x0x 94x80x40 94x80x40 94x80x40 900x0x0 900x0x0 Weight Net kg 4.. 9. 4. 9. 9 Installation Data Pipe connection sizes ( inch ) Liquid Φ. ( /4 ) Φ. ( /4" ) Φ9. ( /8" ) Φ9. ( /8" ) Φ9. ( /8" ) Φ9. ( /8" ) Φ9. ( /8" ) Φ9. ( /8" ) Gas Φ. ( / ) Φ. ( /" ) Φ.9 ( /8" ) Φ9.0 ( /4" ) Φ9.0 ( /4" ) Φ9.0 ( /4" ) Φ9.0 ( /4" ) Φ9.0 ( /4" ) Maximum pipe length m 0 0 0 0 0 Maximum height difference m 8 0 0 0 0 0 Power supply V/ph/Hz 0-40//0 0-40//0 0-40//0 0-40//0 0-40//0 80-4//0 80-4//0 80-4//0 * Cooling Capacity and Energy Efficiency Ratio (EER) based on ISO Standard at conditions : /4ºC db/wb ambient Temperature. /9ºC db/wb Indoor Temperature. High Air Flow 0 volts power supply (for sizes -8-4-0-) Single Phase. 80 volts power supply (for sizes -48-0) Three Phase. * Heating Capacity and Coefficient Of Performance (COP) are based on ISO Standard at operating conditions : 0/ºC db/wb Indoor Temperature /ºC db/wb Outdoor Temperature. High Air Flow 0 volts power supply (for sizes -8-4-0-) Single Phase. 80 volts power supply (for sizes -48-0) Three Phase. * Sound pressure is measured in anechoic chamber based on GB/T Standard * Carrier is committed to continuously improving its products according to national and international standards to ensure the highest quality and reliability standards, and to meet market regulations and requirements. All specifications subject to change without prior notice according to Carrier policy of continuous development.