Cavitator Ultrasonic Cleaners

Similar documents
Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaner Instruction Manual

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Air Pump Up to 800 gallons

Tower Fan MODEL# EE-5607

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

6 Sheet Strip-Cut Shredder for Home/Office

Twin Bell Digital Clock

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Installation & Operation Manual Ice Cream Freezers

Manual Feed Slot Opening. Wastebin. Credit Card Casters

With Remote Control. English

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

75 Sheet Micro-Cut Shredder With CD/DVD Slot

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Universal Fan and Light Remote Control

Owner s Guide. Thank you for purchasing your new Eureka vacuum! Important instructions.

Owner s Manual. PIR-1 IR Learner

With Remote Control. English. Model

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

DEHUMIDIFIER. User Manual 50BT, 70BT

Projection Alarm Clock USER GUIDE

A2Z Ozone, Inc. PRODUCT MANUAL

Outdoor Refrigerator USER S MANUAL

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

&Fan. Instruction Manual. ULTRASlimline Heater. Model: (with remote control) Voltage: 120V AC Frequency: 60 Hz Power: 1500 W

Digital Heat Block User Manual

Installation Guide. Manufactured for Aero-Spa, LLC Web:

Self-Setting Clock Radio


USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

60In. Ceiling Fan. Owner s Manual

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

User s Manual and Operating Instructions

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Panel Mounted Heat Exchangers by Dantherm, Inc.

Ui REFRIGERATOR SPEC SHEET

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Cat 5 Pro Vacuum OPERATOR S MANUAL

OWNER S MANUAL COOL MOISTURE HUMIDIFIER 1.25 GALLON (4.7 LITERS) OUTPUT PER DAY* RCM-832N. *Output dependent on room temperature and humidity.

Revolutionary Science RS-IF-202

U.S. PATENTS D526,714; D527,094; D530,415; D532,896; D536,777

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

ENDURANCE Conductivity Sensors

IMPORTANT SAFETY INSTRUCTIONS

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

Owner s Manual TDS8515. Model Numbers:

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Xaact Spot. Xaact Hot Spot

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

PIR Sensor. User s Guide

Copyright Rollibot, LLC. All Rights Reserved USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

IMPORTANT SAFETY INFORMATION:

Model Number: RF40D. Before the refrigerator is used, it must be PROPERLY POSITIONED, LEVEL -- and installed as described in this manual.

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

ULTRASONIC CLEANERS INSTRUCTION MANUAL MODELS

Instruction Manual for the Revolutionary Science RS-PB-100 Poly Pro Bath TABLE OF CONTENTS

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

Please consider the option to recycle the packaging material and donate any appliance you are no longer using.

TEA CUP SHAPED CLOCK RADIO WITH NIGHT LIGHT

Safety Information. Continued on page 4

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

Outdoor/Commercial Refrigerator USER S MANUAL

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

INSTALLATION & OPERATING INSTRUCTIONS


Operator s Manual. IP-100 Immersion Probe Cooler

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

VersaBrew SINGLE SERVE COFFEE MAKER USER GUIDE

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

IMPORTANT SAFETY INFORMATION:

- Oscillating Table Model Fan

TRADITIONAL CONCEPT INSTRUCTION MANUAL WARRANTY CERTIFICATE

IMpORTANT SAFETy INSTRUcTIONS

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

Pressurized Filter Up to 1250 gallons

ELECTRIC FIREPLACE OWNER S MANUAL

2h 4h 6h. Ultrasonic Humidifier CAUTION: READ MANUAL CAREFULLY FOR PROPER PROCEDURES AND OPERATION.

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

Please Keep This Manual For Future Reference REV.01

INSTRUCTIONS FOR OPERATION AND CARE OF

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

POWERSHRED. 99Ci. Quality Office Products Since Please read these instructions before use. Do not discard: keep for future reference.

#1 BRAND IN MASS AGE* HMC-100MASSAGECHAIR INSTRUCTION MANUAL AND WARRANTY INFORMATION ONE YEAR LIMITED WARRANTY HMC-100

Transcription:

Cavitator Ultrasonic Cleaners Instruction Manual 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com email: mail@ mettlerelectronics.com IR6 19 June, 2007 Copyright 1994 by Mettler Electronics Corp. Anaheim, CA

Mettler Electronics Corp. FCC Frequency Interference Statement Warning: This equipment generates and uses radio frequency energy, and if not installed and operated in strict accordance with the manufacturer s instructions, may cause radio frequency interference. Notice 1: This equipment has been verified to comply with the specifications in Part 18 of FCC Rules, which are designed to provide reasonable protection against radio frequency interference. However, there is no guarantee that interference will not occur in a particular installation. Notice 2: If this equipment is found to be the source of radio frequency interference, which can be determined by turning the equipment off and on, the user should try to correct the interference by one or more of the following measures: Reorient the receiving antenna (as applicable). Relocate the Cavitator with respect to the receiver. Move the Cavitator away from the receiver. Plug the Cavitator into a different outlet than the receiver. If necessary, the user should consult with the dealer or manufacturer for additional suggestions. (The user may find FCC s Interference Handbook helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock No. 004 000 00450 7.) Notice 3: The manufacturer is not responsible for any interference caused by unauthorized modification to this equipment. Mettler Electronics Corp., 1333 S. Claudina St., Anaheim, CA 92805 Toll Free: (800) 854 9305, Or (714) 533 2221 2

Cavitator Ultrasonic Cleaners Instruction Manual Table of Contents Section Title Page 1 Introduction 5 1.1 Introduction to Cavitator Ultrasonic Cleaners 5 1.2 Introduction to this Manual 6 1.3 Safety Precautions and Service Information 6 1.4 Shipping Damage 7 1.5 Package Contents 7 1.6 Limited Warranty Statement 8 2 Operating Instructions 9 2.1 Precautions 9 2.2 Operating Procedures 10 2.3 Choosing a Cleaning Solution 11 2.4 Cleaning in Beakers 12 3 Specifications 13 4 Accessories 15 4.1 Ordering Information 15 4.2 Cavitator Ultrasonic Cleaner Accessories 15 4.3 Cavi Clean Liquid Detergent and Additive 15 3

Mettler Electronics Corp. List of Figures Section Title Page 1.1 The Cavitator Family of Ultrasonic Cleaners 5 2.1 Cavi-Clean ultrasonic cleaning detergent 11 4.1 Cleaning Baskets, (1011, 1055, 1058 and 1059) 14 4.2 Stainless Steel Covers, (1012, 1025 and 1038) 14 4.3 Spray Rinse Attachment, (510) 14 4

Cavitator Ultrasonic Cleaners Instruction Manual Section 1: Introduction 1.1 Introduction to Cavitator Ultrasonic Cleaners Instead of a few hundred brush bristles scratching the surface here and there, ultrasound creates millions of microscopic bubbles that dislodge contamination and foreign matter, even from blind holes, tight joints, pores and places that cannot be reached by laborious soaking and/or scrubbing. Ultrasound produces these tiny cleaning bubbles by a process called cavitation. Now, using your new Cavitator ultrasonic cleaner, you can take full advantage of that remarkable ultrasonic action called cavitation which gets items cleaner with less effort and time than the next best method: the scrub brush. You now have the energy to reach and clean even the tightest hidden corners between close fitting parts that are otherwise impossible to clean. You can now loosen even strongly adherent foreign particles and rinse them away in seconds. Figure 1.1 The Cavitator Family of Ultrasonic Cleaners 5

Mettler Electronics Corp. 1.2 Introduction to This Manual Read the contents of this manual prior to using your new Cavitator ultrasonic cleaner. This manual has been written to assist you with the safe operation of the Cavitator ultrasonic cleaner. It is intended for use by the owners and operators of the Cavitator ultrasonic cleaner. The goal of this manual is to direct the correct operation and maintenance of this unit. The specifications and instructions presented in this manual are in effect at the time of its publication. These instructions may be updated at any time at the discretion of the manufacturer. Please return the self addressed, postage paid Warranty Registration Card, so that you can be notified about improvements to this manual. 1.3 Safety Precautions and Service Information This Cavitator ultrasonic cleaner operates with high voltages. Servicing of this cleaner should be performed by qualified service technicians or it should be returned directly to the factory. To maximize safety during use, the unit should be plugged into a grounded wall outlet of proper voltage only. Service may be obtained from the manufacturer by sending the Cavitator ultrasonic cleaner in its original shipping container to: Mettler Electronics Corp., 1333 South Claudina Street, Anaheim, CA 92805, ATTN: Service Department. Telephone toll free: (800) 854 9305. For prompt and efficient service, provide date of purchase, model and serial number of the cleaner and a brief description of the problem. NOTE: All warranty repairs must be performed by Mettler Electronics Corp. or by a service facility authorized by Mettler Electronics to perform warranty repair work. In cases where units have exceeded the warranty period, estimates of repairs to be made will be provided at the customer s request. Shipping charges to and from the factory must be paid by the owner, and return method of shipping should be indicated. A parts list and set of schematics for your Cavitator ultrasonic cleaner is available from Mettler Electronics Corp. at no charge. 6

1.4 Shipping Damage Cavitator Ultrasonic Cleaners Instruction Manual Your new Cavitator ultrasonic cleaner is shipped complete in one carton. Upon receipt, please inspect the carton and the unit for visible and hidden damage. If any damage is discovered, hold all shipping materials, including the carton, and call the shipping agent who delivered the unit. The shipping agent is responsible for all damage in transit; therefore, all claims should be filed directly with the agent. The factory will not be responsible for any damage in shipment, nor allow any adjustments unless proper formal claim has been filed by the receiver against the carrier. The carton in which your new Cavitator ultrasonic cleaner was received is specially designed to protect the unit during shipping. Please retain all shipping materials in the event that you will need to return your unit for servicing. 1.5 Package Contents Your new Cavitator ultrasonic cleaner comes complete with all the necessary components to perform ultrasonic cleaning. Please note, all Cavitator ultrasonic cleaners are shipped with an instruction manual, warranty card and one sample each of Cavi Clean detergent and Cavi Clean additive. Listed below are additional items that are included in the shipping carton with selected Cavitator models. ME 11 ME 5.5S ME 18 Drain hose Fill hose, #1159 Drain valve and hose bib, (1", 2.54 cm) Cleaning basket, #1055 Cleaning basket # 1059 Fill hose, # 1159 7

Mettler Electronics Corp. 1.6 Limited Warranty This Cavitator Ultrasonic Cleaner is warranted against defects in materials and workmanship for a period of one year from date of purchase. During the applicable warranty period Mettler Electronics Corp. will, at its discretion, either repair or replace the Product without charge for these types of defects. For service under this warranty, the Product must be returned by the buyer within the applicable warranty period to Mettler Electronics Corp. Shipping charges to Mettler Electronics Corp. under this warranty must be paid by the buyer. The buyer must also include a copy of the sales receipt or other proof of the date of purchase. If the Product is returned without proof of the date of purchase, it will be serviced as an out of warranty product at Mettler Electronics Corp. s prevailing service rates. Alteration, misuse, or neglect of the Product voids this warranty. Except as specifically set forth above, Mettler Electronics Corp. makes no warranties, express or implied, including without limitation any implied warranty of merchantability or fitness for a particular purpose, with respect to the Product. If any implied warranties apply as a matter of law, they are limited in duration to one year. Mettler Electronics Corp. shall not be liable for any indirect, special, consequential or incidental damages resulting from any defect in or use of the Product. Any legal action brought by the buyer relating to this warranty must be commenced within one year from the date any claim arises and must be brought only in the state or federal courts located in Orange County, California. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to the buyer. This warranty gives the buyer specific legal rights, and the buyer may also have other rights which vary from state to state. 8

Cavitator Ultrasonic Cleaners Instruction Manual Section 2 Operation Instructions 2.1 Precautions Before you operate you Cavitator ultrasonic cleaner, please review the following precautions. 1. Ground The Unit Grounding the unit is very important. If not grounded, a strong alternating current tingling sensation may be encountered by the operator. For added safety, all electrical equipment must be grounded. 2. Three Prong Plug Each cleaner is equipped with an 8 foot (2.4 m) UL approved line cord with a three prong plug to provide grounding for the cleaner. Do not use an adapter to defeat the safety features of this plug. 3. Submersion Of Hands In Tank Although no physiological harm from ultrasonic energy at these frequencies has been reported, submersion of hands in the tank during operation is not recommended. 4. Do Not Use Acids Do not use acids in the cleaning tank, or place the tank so that ventilation is inhibited. This will prevent undesirable effects during the cleaning operation. 5. Do Not Use Flammable Liquids Ultrasonics may enhance the outgassing of flammable liquids, increasing the chance of ignition. 6. Electric Shock Hazard Dangerous voltages are present behind the protective covering. Refer servicing to qualified personnel. 7. Cleaning Versus Disinfection Ultrasound does not sterilize or disinfect objects contaminated with biological materials. 8. Chlorine Solutions Chlorine solutions such as chlorine bleach cause corrosive damage to stainless steel tanks. Do not use chlorine based cleaners. 9

Mettler Electronics Corp. 2.2 Operating Procedures 1. Fill the tank with enough water or suitable solvent to cover the parts. (The unit operates efficiently at any liquid level from one inch to full.) 2. Plug the unit into a grounded AC outlet. 3. Each time the water is changed, add detergent and run the cleaner for five minutes to drive out the air that is dissolved in the water which could interfere with the ultrasonic action. 4. Rinse away excessive loose foreign material before placing parts in the tank. (The spray rinse attachment, # 510, is designed specifically for this purpose.) This allows the liquid in the tank to stay cleaner for longer usage. 5. Turn the timer/switch to the desired time (1 to 15 minutes) and cleaning will start immediately as evidenced by the hissing sound coming from the tank. (NOTE: the presence of this hissing sound is important. It is a sign that your unit is properly cavitating to produce efficient cleaning bubbles.) 6. After the time set on the timer has elapsed, the cleaner will automatically turn off. 7. Since the cleaners are completely self tuned and are pre set and tested at the factory, no adjustments are necessary. 10

Cavitator Ultrasonic Cleaners Instruction Manual 2.3 Choosing A Cleaning Solution 1. Selection of a proper detergent is important because some detergents inhibit ultrasonic action and attack the stainless steel tank. To enhance cleaning, use Cavi Clean for most cleaning needs. Cavi Clean is an all purpose concentrated detergent formulated especially to increase the cleaning efficiency of your ultrasonic cleaner. It is gentle to the hands and has a neutral ph. It will not harm metals or their alloys. Blood cutting agents, a rust inhibitor, and an excellent wetting and penetrating Cavi Clean agent are among its features. 2. Use approximately 1 part Cavi Clean in 100 parts of water, 1 or 2 ounces (30 60 ml) per gallon (3.8 liters). 3. The choice of cleaning solutions depends upon the nature of the soil and the material to be cleaned. Most solvents and all aqueous solutions will support cavitation at the desirable, powerful low frequencies generated by Cavitator ultrasonic cleaners. 4. Use Cavi Clean additive to increase cleaning action to remove metal oxides, stains and to loosen plaster. Important: use only as an additive to Cavi Clean detergent because its use with certain other detergents might cause damage to the cleaning tank or the parts being cleaned. Add 1 to 3 teaspoons (0.4 to 1.1 cc per liter) Cavi Clean additive per gallon (3.8 liters) of water with Cavi Clean detergent. Caution: Repeated usage might remove plating from plated parts and damage stainless steel instruments. Ultrasonic tank damage can be avoided by cleaning in a supplementary glass container (See Cleaning in Beakers below). Extra precautions should be utilized with dissimilar metals. Use only when necessary because Cavi Clean detergent will meet most cleaning requirements. 5. While certain solvents will not support direct cavitation at these preferred frequencies, more than ample power for effective cleaning is transmitted through the metal parts, provided they rest on the bottom of the cleaning tank. 6. Remember: Do not use acid or chlorine solutions such as chlorine bleach in the cleaning tank. 11

Mettler Electronics Corp. 2.4 Cleaning In Beakers Many acid solutions and strong solvents may be successfully used by cleaning in auxiliary beakers. The beakers containing the special cleaning solutions can rest at the bottom of the main cleaning tank. Enough water containing detergent should be maintained so that the beakers are in at least one inch of water. These glass beakers may be purchased at any laboratory supply company. Do not use plastic containers for cleaning in your ultrasonic cleaner. 12

Cavitator Ultrasonic Cleaners Instruction Manual Section 3 Specifications Model 2.1 105/120 (50/60) 4.6 105/120 (50/60) 11 105/120 (50/60) 5.5S 105/120 (50/60) 18 105/120 (50/60) Line Current volts, (Hz) Tank Dimensions Inches (cm) 9 3 / 8 x 5 3 / 8 x 2 5 / 16 (23.8 x 13.7 x 5.9) 9 3 / 8 x 5 3 / 8 x 6 (23.8 x 13.7 x 15.2) 11 3 / 4 x 9 1 / 2 x 6 (29.8 x 24.1 x 15.2) 19 1 / 2 x 11 1 / 2 x 6 (49.5 x 29.2 x 15.2) 21 3 / 4 x 15 3 / 4 x 12 (55.2 x 40 x 30.5) Overall Dimensions Inches (cm) 10 3 / 8 x 6 3 / 8 x 5 11 / 16 (26.4 x 16 x 14.4) 10 3 / 8 x 6 3 / 8 x 9 1 / 8 (26.4 x 16.2 x 23.2) 12 3 / 4 x 10 1 / 2 x 9 (32.4 x 26.7 x 22.9) 21 1 / 2 x 13 1 / 2 x 11 1 / 4 (54.6 x 34.3 x 28.6) 23 3 / 4 x 17 3 / 4 x 31 (60.3 x 45.1 x 78.7) Height Adjustable Model Tank Capacity (Liters) 2.1 2.1 quarts (2) 4.6 4.6 quarts (4.3) 11 11 quarts (10.4) 5.5S 5.5 gallons (20.8) 18 18 gallons (68) Shipping Weight Pounds (kg) 8 (3.6) 9 (4.1) 14 (6.4) 35 (15.9) 130 (59.1) Power Watts Nominal Main Frequency khz 85 67 2 85 67 2 Fuse amperes 200 67 2 Slo Blo 200 67 2 Slo Blo 800 24 10 13

Mettler Electronics Corp. Stainless Steel Cleaning Baskets (#1011, 1055, 1058 and 1059) Stainless Steel Covers (#1012, 1025 and 1038) Spray Rinse Attachment (#510) 14

Cavitator Ultrasonic Cleaners Instruction Manual Section 4 Accessories 4.1 Ordering Information: Cavitator ultrasound cleaning products and accessories are available from Mettler Electronics authorized distributors. For information regarding either Mettler products or a distributor near you, please call toll free, (800) 854 9305 or phone (714) 533 2221 in areas outside the continental United States. Ask for Customer Service. Mettler Electronics is open from 7 AM until 5 PM Pacific Time for your convenience.: 4.2 Cavitator Ultrasonic Cleaner Accessories Catalogue # Item Description 1011 Stainless steel cleaning basket 3" (7.6 cm) deep for model ME 11 1012 Stainless steel cleaning cover for model ME 11 1025 Stainless steel cover for models ME 2.1 and ME 4.6 1038 Stainless steel cover for model ME 5.5S 1055 Extra stainless steel cleaning basket 4" (10.2 cm) deep for model ME 5.5S 1058 Stainless steel cleaning basket 1" (2.54 cm) deep for models ME 2.1 and ME 4.6 1059 Stainless steel cleaning basket 4" (10.2 cm) deep for model ME 18 1159 Extra 5' (1.5 m) long fill hose 510 Spray Rinse Attachment 4.3 Cavi Clean Liquid Detergent and Additive Catalogue # Item Description 1812 Cavi Clean ultrasonic cleaning detergent, case of four, one gallon containers 1816 Cavi Clean ultrasonic cleaning additive, case of six, one pound bags 15

Mettler Electronics Corp. 16