Certificate of Compliance

Similar documents
Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

Certificate of Compliance

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certification Supplement Manual

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Certificate of Compliance

Certificate of Compliance

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

Field Certification Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

An Urgent Bulletin from CSA Group

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

standards: standards:

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

CONTROL BE MADE CHANGES MAY NOT. Page 1

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Installation Instructions

Annubar Flowmeter Series

Hazardous Area Telephone Model EP600

Numerical Standards Listing

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

2007 XYCOM AUTOMATION, LLC.

File E Project 97SC January 21, 1998 REPORT

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Tank Gauging System Special Safety Instruction

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Numerical Standards Listing

Model 144H. Product Data Sheet , Rev DB February Content

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Numerical Standards Listing

1495D. Installation and Operation Manual, 230 Voltage 2/16/2017

Certificate of Compliance

Compact I/O End Caps/Terminators

Technical Information

Model 144H. Product Data Sheet , Rev DB February Content

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

INSTRUCTION & SERVICE MANUAL

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Certificate of Compliance

Overview of Hazardous Locations as They Relate to Solenoid Valves

UL HAZARDOUS LOCATIONS SERVICES

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

IECEx Certificate of Conformity

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

SEL-3422 Motor Relay HMI Quick-Start Guide

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safety instructions VEGABAR 81, 82, 83, 86, 87

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

General Specifications

Technical Specification VFD

FLASHLIGHT ANSI STANDARDS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

User s Manual YTA610 and YTA710 NEPSI Certification

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

CERTIFICATE OF COMPLIANCE

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Class I, Division 2 Class I, Zone 2 Hazardous Location Air Conditioners

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

UL TEST REPORT AND PROCEDURE

MICROpeL 75 Combustible Gas Sensor Part Number: PM

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

AS/NZS :2008

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Transcription:

Certificate of Compliance Certificate: 1238566 Issued to: Rosemount Analytical Inc. Solon Research & Development Ctr 6565-P Davis Industrial Pkwy Solon, OH 44139 USA Attention: Dana Crowley The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Marius Manastireanu Marius Manastireanu PRODUCTS 2252-06 PROCESS CONTROL EQUIPMENT 2252-86 PROCESS CONTROL EQUIPMENT - Certified to U.S. Standards Oxymitter series 4000 and DR: 1) OXT4A, rated 90-250 V~, 50/60 Hz; 2) OXT4C, rated 90-250 V~, 50/60 Hz; 3) OXT4ADR, rated 115 V~, 50/60 Hz; 4) OXT4CDR, rated 44V~ or 115V~, 50/60 Hz; 5) SBX 1000, rated 90-250 V~, 50/60 Hz; 6) OXT4CNF, rated 90-250 V~, 50/60 Hz; 7) OXT4CDRNF, rated 115 V~, 50/60 Hz Models 6A00095G05, 6A00095G06, 6A00094G07 & 6A00094G08 Oxymitter 4000 series Standalone Remote Electronics with Standard Filtered Terminal Block, LOI Display and Window Cover, rated 90-250 V~, 50/60 Hz Max. 500 VA, pollution Degree 2, Over Voltage Category II, operating temperature range -40 to 70 C, relative humidity 5 to 95 % (non-condensing) Notes: The equipment is intended to be connected to supply mains according to the applicable local and national (e.g. CEC & NEC) regulations. DQD 507 Rev. 2012-05-22 Page 1

CLASS 2258 02 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations CLASS 2258 82 - PROCESS CONTROL EQUIPMENT - For Hazardous Locations - CERTIFIED TO U.S. STANDARDS Class I, Division 1, Groups B, C and D: Class I, Zone1, Ex d IIB+H2 T2* Class I, Zone1, AEx d IIB+H2 T2* Oxymitter Oxygen Transmitters: (Integral & DR) 4000 Series - Models OXT4C-abcdefghij and OXT4CNF-abcdefghi - Input rated 90-250 V~, 50/60 Hz, Max. 500 VA, pollution Degree 2, Over Voltage Category II, operating temperature range -40 to 70 C, Temperature Code T2, relative humidity 5 to 95% (non-condensing); Model OXT4C-abcdefghij, Oxymitter 4000 Oxygen Transmitters a = Sensing Probe Type: 1, 2, 3, 4, 5, 6, 7 or 8 b = Probe Assembly: 0, 1, 2, 3, 4, 5 or 6 d = Mounting Adapter - Probe Side: 0, 1, 2, 4, 5, 7 or 8 e = Electronics Housing: 21 or 22 f = Communications: 1, 2 or 3 g = Language: 1, 2, 3, 4 or 5 h = Termination Filtering: 00 i = Calibration Accessories: 00 or 01 j = Hazardous Area Approval 00 Model OXT4CNF-abcdefghi, Oxymitter 4000 Oxygen Transmitters a = Sensing Probe Type: 1, 2, 3, 4, 7 or 8 b = Probe Assembly: 0, 3, or 5 d = Mounting Adapter - Probe Side: 0, 1, or 4 e = Electronics Housing: 22 f = Communications: 1, 2 or 3 g = Language: 1, 2, 3, 4 or 5 h = Calibration Accessories: 00 or 01 i = Cable 00 DR Series - Models OXT4CDR-abcdef20 and OXT4CDRNF-abcdef20 - rated 44V~ (only for model OXT4CDR) or 115V~, 50/60 Hz, Max. 500 VA, pollution Degree 2, Over Voltage Category II, operating temperature range -40 to 70 C, *Temperature Code T1 for 44V~ model (OXT4CDR only) and T2 for the 115V~ model (both OXT4CDR and OXT4CDRNF), relative humidity 5 to 95% (non-condensing); Model OXT4CDR-abcdef20, Oxymitter DR Oxygen Probe a = Sensing Probe Type: 1, 2, 3, 4, 5, 6, 7, 8, A, B, C, D, E or F b = Probe Assembly: 0, 1, 2, 3, 4, 5 or 6 DQD 507 Rev. 2012-05-22 Page 2

d = Mounting Adapter - Probe Side: 0, 1, 2, 4, 5, 7 or 8 e = Electronics Housing: 11 or 12 f = Arrangement: 03, 04, 05, 07, 08 or 09 Model OXT4CDRNF-abcdef20, Oxymitter DR Oxygen Probe a = Sensing Probe Type: 1, 2, 3, 4, 7 or 8 b = Probe Assembly: 0, 3 or 5 d = Mounting Adapter - Probe Side: 0, 1, or 4 e = Electronics Housing: 12 f = Arrangement: 03, 04, 05, 07, 08 or 09 Class I, Zone 1, Ex de IIB+H2 T6 (Remote Electronics) / T2 (probe) Class I, Zone 1, AEx de IIB+H2 T6 (Remote Electronics) / T2 (probe) Class 1, Division 1, Groups B, C and D T2 (Probe) Class 1, Division 2, Groups B, C and D T6 (Remote Electronics) Oxymitter Oxygen Transmitters: (Split Architecture, Probe with Remote Electronics) 4000 Series - Models OXT4C-abcdefghij and OXT4CNF-abcdefghi - Input rated 90-250 V~, 50/60 Hz, Max. 500 VA, pollution Degree 2, Over Voltage Category II, operating temperature range -40 to 70 C, relative humidity 5 to 95% (non condensing); Model OXT4C-abcdefghij, Oxymitter 4000 Oxygen Transmitters a = Sensing Probe Type: 1, 2, 3, 4, 5, 6, 7 or 8 b = Probe Assembly: 0, 1, 2, 3, 4, 5 or 6 d = Mounting Adapter - Probe Side: 0, 1, 2, 4, 5, 7 or 8 e = Electronics Housing: 23 or 24 f = Communications: 1, 2 or 3 g = Language: 1, 2, 3, 4 or 5 h = Termination Filtering: 00 i = Calibration Accessories: 00 or 01 j = Hazardous Area Approval 00 Model OXT4CNF-abcdefghi, Oxymitter 4000 Oxygen Transmitters a = Sensing Probe Type: 1, 2, 3, 4, 7 or 8 b = Probe Assembly: 0, 3, or 5 d = Mounting Adapter - Probe Side: 0, 1, or 4 e = Electronics Housing: 24 f = Communications: 1, 2 or 3 g = Language: 1, 2, 3, 4 or 5 h = Calibration Accessories: 00 or 01 i = Cable 00 DQD 507 Rev. 2012-05-22 Page 3

Permanently connected, Oxymitter 4000 Standalone Remote Electronics Model 6A00094G with Standard Filtered Terminal Block, LOI Display and Window Cover, rated 90-250 V~, 50/60 Hz, 500 VA, pollution Degree 2, Over Voltage Category II, operating temperature range -40 to 55 C, relative humidity 5 to 95% (non condensing); Note: Catalogue number 6A00094G may be followed by two numerical suffixes identifying constructional variations of the Split Architecture covered in the Descriptive Report (ex. one flat cover with one window cover versus two flat covers) Special Condition for Safe Use 1. Non-flame arrestor probe -NF versions must have the probe tube installed in a Non-Classified Area. 2. When the probe tube is mounted in a Hazardous (Classified) Area (with flame arrestor end to complete the assembly) calibration lines that travel in and out of the equipment bringing reference gas must not contain a pressure higher than 1.1 times the atmospheric pressure; these calibrating lines shall not contain pure oxygen, acetylene, or combustible gases other than the gases for which this Zones 1 Classified application has been investigated for: Group IIB+H 2 gases. 3. There are no interchangeable components 4. Contact the original manufacturer for information of the flame-proof joint dimensions 5. Fasteners property class must be A2-70 for units intended for use in Zone 1 classified areas. 6. Any other electronics not covered by this report and used in conjunction with the Oxymitter Probes or with the Remote Electronics must be installed in a Non-Classified Area (ex. Xi Advanced Electronics) APPLICABLE REQUIREMENTS CSA C22.2 No. 30-M1986 (R1999) - Explosion-Proof Enclosures for Use in Class I Hazardous Locations CSA C22.2 No. 213-M1987 (Reaffirmed 2008) - Non-incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations CAN/CSA-E60079-0:02 - Electrical Apparatus for Explosive Gas Atmospheres; General Requirements CAN/CSA-E60079-1:02 - Electrical apparatus for use in Class I, Zone 1, Hazardous (Classified) Locations; Type of protection Flameproof d CAN/CSA-E79-7:03 - Electrical apparatus for use in Class I, Zone 1, Hazardous (Classified) Locations; Type of protection Increased Safety e CAN/CSA-C22.2 No 61010-1-12 - Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements UL Std No. 1203 Ed. 3 - Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations ANSI/ISA 12.12.01-2013 - Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations UL 61010-1 (3 rd Edition) - Safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements ANSI/ISA 12.16.01-1998 - Electrical Apparatus for use in Class I, Zone 1 Hazardous (Classified) Locations; Type of protection Flameproof e ANSI/ISA 12.00.01-2002 - Electrical Apparatus for use in Class I, Zone 0, 1 &2 Hazardous (Classified) Locations; General Requirements ANSI/ISA 12.22.01-2002 - Electrical Apparatus for use in Class I, Zone 1 Hazardous (Classified) Locations; Type of protection Flameproof d DQD 507 Rev. 2012-05-22 Page 4

MARKINGS The manufacturer is required to apply the following markings. Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. It is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. Markings appear on min 0.02 in thick metal nameplates, secured to the enclosure with drive pins or screws, into bottomed holes. Serial numbers and the bilingual cautionary statements appear on separate nameplates secured as above. As per Drawings 3D39743 (page 8 of 9), 3D39814 (page 8 of 9), 3D39875 (page 5 of 6), 6R00124 (page 8 of 9), 6R00125 (page 8 of 9) and 6R00126 (page 5 of 6). Nameplate: 1. CSA Monogram with the Certification reference (2004.1238566) or if not near the Monogram CSA.2004.1238566; 2. Submittor's name and/or Master Contract Number 212516; 3. Specific catalogue or model designation; 4. Serial Number, Date code or equivalent; 5. Electrical ratings (V, Hz, A or VA); 6. Hazardous Location designation; 7. Max ambient; 8. An indication of the manufacturing location, if the equipment is manufactured at multiple locations; 9. Temperature Code Rating; 10. The Entity Parameters; 11. \Safety related symbols (ISO 3864, No. B.3.6 and No. B.3.1, IEC 417, No. 5041 ) 12. Caution re. Keeping cover tight while circuits are live and Attention: Garder le couvercle bien ferme tant que les circuits sont sous tension or the equivalent. 13. Seal not required and Étanchéité ne est pas nécessaire or equivalent. On device: 1. Replacement fuse markings: Fuse type(s) and rating(s) (in volts and amperes), adjacent to the fuse holder(s) 2. Protective Earth Terminal symbol adjacent to ground terminal The following statements marked on the terminal compartment of the Remote Electronics Enclosure: 1. WARNING EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2 and AVERTISSMENT RISQUE D EXPLOSION LA SUBSTITUTIOIN DE COMPOSANTS PEUT RENDRE CE MATERIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I, DIVISION 2 or equivalent DQD 507 Rev. 2012-05-22 Page 5

2. WARNING EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS and AVERTISSMENT- RISQUE D EXPLOSION AVANT DE DECONNECTER L EQUIPMENT, COUPER LE COURTANT OU S ASSURER QUE L EMPLACEMENT EST DESIGNE NON DANGEREUX or equivalent. DOCUMENTATION Each product shall be accompanied by the following documentation: General: Technical specifications, instructions for use and details of where technical assistance may be obtained if required. Explanation for all warning or caution symbols used in the equipment. Equipment Ratings: Including equipment supply, description of I/O connections, duty cycle and operating environmental conditions. 1. Pollution degree rating; 2. Installation category (optional); 3. Electrical supply ratings (V, Hz, A) 4. Indoor use statement; 5. Temperature/Humidity rating; 6. Replacement Fuse Ratings (certified equivalent to fuse noted in critical component) 7. Instructions and ratings for proper wiring (voltage, temperature, type, size) and connection Equipment Installation: Including instructions for assembly and mounting, location requirements, details for special services (cooling supply, etc.) as applicable. Instructions provide list of product-specific RISKS that may affect service personnel. Instructions shall include statement for connection to MAINS through an external switch or circuit-breaker/external overcurrent protection devices and a recommendation that such protection be located near equipment. 1. Instructions for wiring including wire type, gage, voltage, etc. (minimum 300V, 90C) 2. Wiring to or from the Remote Electronics Enclosure, which enters or leaves the system enclosure, must utilize wiring methods suitable for Class I, Division 2 Hazardous Locations, as appropriate for the installation. Equipment Operation: Including explanations of operating controls and warning symbols used, and instructions for interconnection, replacement of consumables (e.g. paper) and cleaning and decontamination as required. Instructions provide list of product-specific RISKS that may affect service personnel. 1. List of accessories which meet the manufacturer s specifications to be used; 2. List of hazardous substances that can be liberated from the equipment and possible quantities; Equipment Maintenance: Including instructions for preventative maintenance, inspection and cleaning, replacement of parts, etc. Instructions provide list of product-specific RISKS that may affect service personnel. The following statements apply for the terminal compartment of the Remote Electronics Enclosure: 1. This equipment is suitable for installation in Class I, Division 2, Group B, C, D hazardous locations or nonhazardous locations only. or equivalent 2. WARNING EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR DQD 507 Rev. 2012-05-22 Page 6

SUITABILITY FOR CLASS I, DIVISION 2 and AVERTISSMENT RISQUE D EXPLOSION LA SUBSTITUTIOIN DE COMPOSANTS PEUT RENDRE CE MATERIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I, DIVISION 2 or equivalent 3. WARNING EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS and AVERTISSMENT- RISQUE D EXPLOSION AVANT DE DECONNECTER L EQUIPMENT, COUPER LE COURTANT OU S ASSURER QUE L EMPLACEMENT EST DESIGNE NON DANGEREUX or equivalent. The following statements apply to the probe assembly: 1. Caution re. Keeping cover tight while circuits are live and Attention: Garder le couvercle bien ferme tant que les circuits sont sous tension or the equivalent. 2. Seal not required and Étanchéité ne est pas nécessaire or equivalent. DQD 507 Rev. 2012-05-22 Page 7

Supplement to Certificate of Compliance Certificate: 1238566 Master Contract: 161061 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History 70006916 April 3, 2015 Update to report 1238566 with Class I, Division 2 Group BCD classification for the Oxymitter 4000 Remote Electronics (Split Architecture) and Class I, Division 1, Groups BCD classification for the Oxymitter 4000 Probe. 2752380 Feb 20, 2015 Update of models in report 1238566 to 61010-1 (3rd Edition) for ordinary location 2294470 Jun 4, 2010 Update to Report to 1238566 to include updated drawings and add models OXT4CNF, OXT5CNF and OXT4CDRNF for ordinary locations and hazardous locations. 2021896 Jun 19, 2008 Update to Certificate 1238566 for minor revision to Oxymitter 5000 Oxygen transmitter (Model OXT5C) to add alternate Fieldbus card. 1790776 May 4, 2006 Update to Certificate 1238566 for minor revisions to OXT 4000, 5000, DR & SBX 1771484 Apr 3, 2006 Update to report for minor changes to Oxymitter Series 1635826 Feb 4, 2005 Addition of the Oxymitter series to include SBX 1000 model for Ordinary Locations. 1525122 Jun 24, 2004 Addition of the OXT4CDR 44V Probe model and adding new Split Architecture models for zone certification only DQD 507 Rev. 2012-05-22 Page 1