IQ8Control C Fire Alarm Panel

Similar documents
All the security you need in one housing

tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology

TOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS

New dimensions in fire detection technology FlexES control: the dawning of a flexible, trendsetting system

A Soft (R)evolution. For a flexible future: modular fire alarm technology by ESSER

Basic Fire Alarm SystemTraining. Arman Alnasar

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

IQ8Wireless. Radio technology: flexible functionality IQ8Wireless intelligent, wireless fire protection. Fire detection technology

Voice Alarm Systems. Inform Selectively, Evacuate Safely Complete systems for voice alarm and fire detection technology

FlexES Control Flexible solutions with the modular fire detection system

Concepts for the secure networking of large building complexes

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

Clino Guard. Safety without Compromise

561-MB256 plus. Intruder alarm control panel. Performance features

Product Catalog Fire Alarm Systems

esserbus -PLus maximum security, minimum costs

561-MB48. Intruder Alarm Control Panel

Product Catalogue 2008 / Fire Alarm Systems

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc.

Fire control panel detect 3004 plus and accessories

clino System 99 protect Safety in Enforcement and Forensic Facilities Communication solutions for high-security areas

Clino System 99. Intelligent Life Care Integrated Communication Systems for Care Provision

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

Solution F2. Fire Alarm Control Panels one step ahead.

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Installation Instruction. Fire Alarm Control Panel Compact GB0

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

SUPREMATouch. Modular Fire & Gas Detection System

Operation and Installation Instructions

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

SUPREMATouch. Modular Fire & Gas Detection System

Installation Instruction. Fire Alarm Control Panel IQ8Control C/M GB0 G G Technical changes reserved!

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

Made possible by an innovative licensing scheme, which allows individual hardware configuration, up to the maximum configuration:

SUPREMATouch Modular Fire & Gas Detection System

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

XP95 Sounder VAD Base

Consultant Specification AGILE Wireless Fire Detection System

IQ8Quad. The right sensor for every environment. The detection principles of the IQ8Quad detector. Fire detection technology

Operation and Installation Instruction

Quickstart Guide. Fire Alarm System Design

Line Smoke Detector LRMX

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC700A Fire detection control unit

Fire control panels FC726 FC726-XA

The EN54 Part 2 & 4 Fire System

ANNEX A.1 TECHNICAL SPECIFICATIONS Negotiated Procedure FRA Provision of Security Supplies and Installations

Intellia Sounder Bases and Sounder Beacon Bases

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Availability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems. FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Intelligent addressable fire alarm control panel

Solution F1. Fire Control Panels the new generation

ACP10 & ACP50 Security Systems

ZXSe Range Data Sheet

System 800 Addressable Fire Detection & Alarm System

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Advanced FireAlarm Panel 1-4Loop

FC724 Fire control panel

SI120 Guarto Easy I. Alarm system. Fire & Security Products

Integrated security systems. The security spectrum Systems for comprehensive building security

IC60 Sintony 60 Intrusion Control Panel

MINERVA MZX125 Digital Addressable Fire Detection System

FC722 Fire control panel

Fire & Security Products. Cerberus D100 Multifunctional process control for company security

FC724 Fire control panel

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

On the job around the clock 24/7: Fire detection systems

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

Healthy. Atmosphere. for Pigs and Poultry. for a

Modular Fire Panel 5000 Series Just as flexible as your plans

FC723 Fire control panel

The EN54 Part 2, 4 and 13 Fire System

Sita200plus. 200detectors. Single loop analogue addressable System

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Installation, Operating and Maintenance Manual

ID50series. intelligent fire alarm panels

DCS-100. intelligent damper control & monitoring system

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

CODESEC FIRE ALARM SYSTEMS. security technologies

Radio fire warning panel SRC 3000

Intelligent Single Loop Fire Alarm Control Panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

FC722 Fire control panel

intelligent solutions

Remote alarm indicator and test combination MK2430

Quick Selection Guide Fire Systems LSN Periphery

Intelligent Addressable Fire Alarm System

Xenex Conventional Fire Detection & Alarm System

Fire Detection Systems Product Catalogue (Version )

E3 Series Broadband System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Parameterisable compact fault annunciator with permanent display

Security that fits your needs perfectly DS7220 V2/DS7240 V2 intrusion control panel

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Engineering Guideline. pac- Carriers Type Universal

Features. Windows management system for hazard detection systems

NETWORK FIRE ALARM CONTROL PANEL. Features

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Transcription:

IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means of new IQ8Quad detector generation Supports IQ8Wireless Radio Technology and IQ8Quad detectors with alarm devices A maximum of 31 control panels can be networked via essernet (500 kb) Up to two esserbus loops, which can be extended by spurs Micro modules compatible both for System 8000 and IQ8Control Modular space saving design compact, flexible and future-proof The IQ8Control C fire alarm panel complies with the highest security requirements for complex detection purposes and reliable technology standards. As an all-rounder within the market segment for automatic fire protection in small and mediumsize premises, the control panel is provided with multiple features such as compact dimensions, a broad functional range and multiple expansion options as well as an excellent cost/performance ratio. Both features ensure individual planning and guarantee a future-proof solution in the domain of fire alarm technology. If required, the control panel software can be replaced by an upgrade version via PC. Professional loop technology ensures economic efficiency even for small applications The IQ8Control C fire alarm panel is designed in compliance with high performance loop technology. The esserbus is a short and open circuit resilient loop, offering highest operational reliability as well as cost saving installation options on account of reduced wiring through combined loop and spur topologies. All single-criterion and multi-criteria detectors can be connected via the esserbus - this includes everything from Series 9000 standard fire detectors to Series 9200 intelligent fire detectors and IQ8Quad detectors. The IQ8Control C is completely compatible to the fire alarm system 8000 control panels. The modular design allows flexible and user friendly integration of various modules, which together from one unit. Each system extension and the emergency power supply can be adjusted to suit advanced requirements by adding one or more modules. esserbus

IQ8Control C Fire Alarm Panel Flexibility and reliability within the loop structure The esserbus allows a combined loop and spur structure with a maximum length of 3.5 km. Up to 127 bus devices can be divided in up to 127 detector zones, which guarantees a high degree of planning and application flexibility. Each IQ8Quad detector is supplied with isolators, while other bus devices can be optionally provided with isolators. Thus, each bus device remains operative in case of wire break or short circuit. Only the corresponding part of the loop located between the affected bus devices with isolators is replaced. The s are bus devices with freely programmable inputs and outputs for controlling and monitoring external devices or for connecting special detectors. Sensors integrated in single detectors within the esserbus system are subject to manual or time-related activation /deactivation. The esserbus is suitable for transmitting alarm, fault and maintenance signals. In addition, each detector's position within the bus system can be allocated when viewing the corresponding text display. Logged security Each event is logged by the IQ8Control C fire alarm panel in second intervals. A maximum of 10,000 events can be verified at any time and subsequently read out via an optional printer connection within the control panel or via the tools 8000 programming software. The information can then be stored on a data carrier if required. essernet Within the essernet system up to 31 devices such as control panels, indicating and operating panels, gateways as well as user file depositories can be networked irrespective of hierarchical levels. Events and reports are available for all devices when connected to the essernet. Easy installation and operation The tools 8000 service and programming software package guarantees fast and simple commissioning. The settings are programmed directly at the control panel via a PC / laptop. Only essential information is displayed, which considerably facilitates system operations. When connected to the essernet, decentralised operation is also possible. Optionally, alarm and status information can be displayed via single zone indicators at the control panel, via decentralised graphic layout panels or plain text displays. It might as well be printed out using remote printers or the printer integrated in the control panel. external devices FAP 8008 OEC-converter essernet Loop length max. 1 km each (with repeater max. 3 km) IQ8Control C Loop length max. 2 km Repeater Management system WINMAG

Innovative alarm signalling and evacuation Innovative integration for optical and acoustic signalling devices, which are consistently installed via the powered loop network, is ensured by bus supplied alarm signalling devices and the IQ8Control C fire alarm panel. Thus, the IQ8Control C fire alarm panel and the IQ8Quad fire detectors provide an economic solution by means of minimised installation expenses. All addressable alarm signalling devices comply with EN 54-3. They support alarm tones in compliance with DIN 33404-3 and another 18 international alarm tones with a standard sound pressures of up to 96 db (A). IQ8Control C Flash Speech loop 1 loop 2 Flash Sound Speech The IQ8Quad detector with integrated alarm signalling devices and its key features: an external power supply unit for the signalling devices is not required flasher, sounder and speech alarm device can be individually controlled each device with the whole functional range alarm signalling devices are automatically synchronised Trouble-free radio technology integration When connecting radio communication devices to the IQ8Control C fire alarm control panel, all devices remain individually addressable as usual and the whole functional range is maintained while each radio communication device is allocated only one address. For planning purposes and commissioning, the tools 8000 programming software package is implemented. When using the software solution, the respective field strength can be measured. Automatically generated frequency modifications secure trouble-free communication between the radio communication devices. In terms of system expansion, the radio communication devices serve as an ideal solution for maintaining unrestricted functionality of all previous installations and further features can be added to the functional range. Wireless transponder 12V DC loop length max. 2 km IQ8Control C A variety of operating panel fronts: optimum solution for providers and fire services The wide range of operating panel fronts offers the an optimum solution for all requirements set up by the providers and fire services. Therefore, it perfectly bridges the gap between man and technology. The operating panel fronts are available in various languages. Each text is displayed in the respective language on the standard display or the 1/4-VGA graphics display.

Arrangement of the devices: Dimensions (mm) Battery Battery Peripheralmodule Basis card, power supply card and analog ring loop module 320 450 185 Technical data Mains voltage 230 V AC Mains frequency 50 to 60 Hz Rated voltage 12 V DC Quiescent current 300 ma without operating panel Rated current 0.7 A Emergency power supply 2 x 12 Ah (max. 2 x 24 Ah, in 789300 extension housing) Current drain for external users max. 2.0 A Ambient temperature -5 C to +45 C Storage temperature -5 C to +50 C Room climate class 3K5 as per IEC 721-3-3: 1994 Class of protection I in compliance with DIN EN 60950 Type of protection IP 30 Housing ABS, 10 % glass fibre reinforced., V-0 Colour grey, similar to Pantone 538 Weight (without battery) 6.5 kg Dimensions (W x H x D) 450 x 320 x 185 mm VdS approval G 299044 Order information Part No. Fire alarm panel IQ8Control C basic design, without operating front 808003 Package 1 of FACP IQ8Control C 808133 Package 3 of FACP IQ8Control C 808135 tools 8000 - initial equipment package / starters kit 789860 Analog loop module system 8000 784382 Analog loop module powered loop 804382 For further order data please refer to our "Fire Alarm Technology" product line catalogue. Part No. 797965.G0 11/2007 Technical information is subject to change without notice! 2007 Honeywell International Inc. Novar GmbH a Honeywell Company Honeywell Life Safety Austria GmbH Dieselstraße 2, Phone: +49 (0) 21 37 / 17-0 Administration Internet: E-mail: D-41469 Neuss Phone: +49 (0) 21 37 / 17-600 Customer Service Center www.esser-systems.com info@esser-systems.com Fax: +49 (0) 21 37 / 17-286 Fernkorngasse 10, Phone: +43 (0)1 / 6 00 60 30 Internet: E-mail: A-1100 Wien Fax: +43 (0)1 / 6 00 60 30-900 www.hls-austria.com hls-austria@honeywell.com

Fire Alarm Panel Latest processor technology Permissible wire length for esserbus up to 3,500 m Graphically supported powerful programming tool Innovative alarm signalling through the new alarm generation IQ8Quad Supports IQ8Wireless RF technology Modular device structure Networking of up to 31 panels via essernet (500 kb) Up to 7 esserbus loops Up to 4 loops EN-54 approval for up to 512 detectors The fire alarm computer for medium-sized to large premises: flexible, multifunctional and future-proof The modular fire alarm computer uses proven technology and fulfils the highest security requirements for the comprehensive protection of premises. Thus, it is just as suitable for use in medium-sized premises with complex security requirements as it is for premises, which are spread over a wide area and are networked. very easily. This not only simplifies individual planning today, but also, as a result of the FAP's extendibility options, ensures future-proof solutions. If necessary, the control panel software can simply be replaced by an upgrade version via a service PC. Professional loop technology: multi-functional, extendible and economic The esserbus is a short and open circuit resilient loop, offering highest operational reliability as well as cost saving installation options on account of reduced wiring through combined loop and spur topologies. All single-criterion and multi-criteria detectors can be connected via the esserbus - this includes everything from Series 9000 standard fire detectors to Series 9200 and IQ8Quad intelligent fire detectors. The is ideally suited to medium-sized premises with complex security requirements and for premises that cover a wide area and/or are networked. The is completely compatible with the fire alarm system 8000 control panels. The modular design allows flexible and user-friendly integration of several individual modules, which together form one unit. The system extension with one or more additional modules can be adapted to advanced requirements esserbus Detectors series 9000

Fire Alarm Panel Flexibility and reliability within the loop structure The esserbus allows a combined loop and spur structure with a maximum length of 3.5 km. Up to 127 bus devices can be divided in up to 127 detector zones, which guarantees a high degree of planning and application flexibility. Each IQ8Quad detector is supplied with isolators, while other bus devices can be provided with them optionally. Thus, each bus device remains operational in the case of a wire break or short-circuits. Only the corresponding part of the loop located between the affected bus devices is automatically isolated. allows implementation of a maximum of 7 esserbus loops or 4 powered loops. The s are bus devices with freely programmable inputs and outputs for controlling and monitoring external devices or for connecting special detectors. Sensors integrated in single detectors within the esserbus system are subject to manual or time-related activation /deactivation. The esserbus is suitable for transmitting alarm, fault and maintenance signals. In addition, the location of each detector within the bus system can be allocated with an appropriate text display. Logged security Each event is logged to the second by the fire alarm computer. A maximum of 10,000 events can be verified at any time and can be read out via an optional printer connection within the control panel or via the tools 8000 programming software. essernet Within the essernet system up to 31 devices such as control panels, indicating and operating panels, gateways as well as electronic emergency plans can be networked irrespective of hierarchical levels. Events and reports are available for all devices when connected to the essernet. Easy installation and operation The tools 8000 service and programming software package guarantees fast commissioning. The settings are programmed directly at the control panel via a service PC. Only essential information is displayed, which considerably facilitates system operations. When connected to the essernet, decentralised operation is also possible. Optionally, alarm and status information can be displayed via single zone indicators at the control panel, via decentralised graphic layout panels or plain text displays. It can also be printed out using remote printers or the printer integrated in the control panel. Example of a tools 8000 screen FAP 8008 OEC-converter external devices essernet loop length max. 1 km each (with repeater max. 3 km) powered loop loop length max. 2 km repeater management system WINMAG esserbus-transponder System configuration example

Innovative alarm signalling and evacuation The bus supplied alarm signalling devices together with the IQ8Control fire alarm computer ensure innovative integration of optical and acoustic signalling devices, which are installed via the powered loop network. Thus, the fire alarm computer and the IQ8Quad fire detectors provide an economic solution by means of minimised installation expenses. Flash Speech loop 1 loop 2 Flash Sound Speech Bus supplied alarm signalling devices All addressable alarm signalling devices comply with EN 54-3. They support alarm tones in compliance with DIN 33404-3 and another 18 international alarm tones with a standard sound level of up to 96 db (A). Trouble-free radio technology integration When connecting radio communication devices to the fire alarm computer, all devices remain individually addressable as usual and the whole functional range is maintained while each radio communication device is allocated only one address. For planning purposes and commissioning, the tools 8000 programming software package is implemented. This software can also be used to measure the respective field strength. Automatically generated frequency modifications secure trouble-free operation and communication between the radio communication devices. In terms of system expansion, the radio communication devices serve as an ideal solution for maintaining unrestricted functionality of all previous installations whilst extending the functional range. 12V DC loop length max. 2 km Wireless transponder The key features of the IQ8Quad detector with integrated alarm signalling: an external power supply unit for the signalling devices is not required flasher, sounder and speech alarm device can be individually controlled each device - even with the whole functional range - only has one of the 127 addresses on the esserbus allocated to it alarm signalling devices are automatically synchronised A variety of operating panel fronts: optimum solution for providers and fire services The wide range of operating panel fronts means that the right solution is always available whatever the requirements of the providers and fire services, thus perfectly bridging the gap between man and technology. The operating panel fronts of the fire alarm panel are available in various languages. The text is displayed in the respective language on the standard display and on the 1/4-VGA graphics display. Examples of operating panel fronts IQ8 wireless devices

450 185 Peripheralmodule Basis card, power supply card and analogue ring loop module Extension module with 3 micromodule slots 640 Battery Battery Technical data Rated voltage 230 VAC Nominal frequency 50 to 60 Hz Rated current 0.7 A Rated voltage 12 V DC Quiescent current 300 ma w/o operating unit Operating current for external load 2 A Battery capacity 2 x 12 V / 24 Ah Ambient temperature -5 C to +45 C Storage temperature -10 C to +50 C Class of protection I as per DIN EN 60950-1 Type of protection IP 30 Housing ABS, 10 % glass fibre reinforced, V-0 Colour grey, similar to Pantone 538 Weight (w/o battery) 11.5 kg Dimensions (W x H x D) 450 x 640 x 185 mm Approval VdS approval G 299044 Order Information Part No. basic version 808004 Package 1, with 4 mikromodule slots 808214 Package 2, with 4 micromodule slots and 64 single zone indicators 808215 Package 3, with 4 micromodule slots and built-in printer 808216 Peripheral module with 1 additional micromodule slot 772477 Extension module with 1 additional micromodule slot 772478 Peripheral module 772479 tools 8000 programming software 789860.10 For further order data please refer to our "Fire Alarm Technology" product line catalogue. Arrangement of the devices and Dimensions Part No. 797966.G0 04/2009 Technical information is subject to change without notice! 2009 Honeywell International Inc. Novar GmbH a Honeywell Company Honeywell Life Safety Austria GmbH Dieselstr. 2, Phone: +49 2137 17-0 (Administration) Internet: E-mail: 41469 Neuss, Germany +49 2137 17-600 (Customer Service Center) www.esser-systems.com info@esser-systems.com Fax: +49 2137 17-286 Lemböckgasse 49, Phone: +43 1 600 6030 Internet: E-mail: 1230 Wien, Austria Fax: +43 1 600 6030-900 www.hls-austria.com hls-austria@honeywell.com