Concepts for the secure networking of large building complexes

Similar documents
tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology

Voice Alarm Systems. Inform Selectively, Evacuate Safely Complete systems for voice alarm and fire detection technology

New dimensions in fire detection technology FlexES control: the dawning of a flexible, trendsetting system

clino System 99 protect Safety in Enforcement and Forensic Facilities Communication solutions for high-security areas

IQ8Control C Fire Alarm Panel

A Soft (R)evolution. For a flexible future: modular fire alarm technology by ESSER

Clino System 99. Intelligent Life Care Integrated Communication Systems for Care Provision

FlexES Control Flexible solutions with the modular fire detection system

Clino Guard. Safety without Compromise

IQ8Wireless. Radio technology: flexible functionality IQ8Wireless intelligent, wireless fire protection. Fire detection technology

MobiCall. Unified Event Communication

TOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

All the security you need in one housing

Basic Fire Alarm SystemTraining. Arman Alnasar

Features. Windows management system for hazard detection systems

Clino Systevo. Intelligent Life Care. Modern Patient Communication intelligently integrated

MobiCall. Unified Event Communication

MobiCall. Unified Event Communication

Pro-Watch Facility Manager

MobiCall-Client PC Safety at work

IQ8Quad. The right sensor for every environment. The detection principles of the IQ8Quad detector. Fire detection technology

Organize your security with PSIM + software

Organize your security with PSIM + software

MobiCall. Unified Event Communication

Success Story Henkel. A WinGuard Reference Project

IRIS Touch Firmware Enhancements and Additions from Version to Version

MobiCall Silent Alarm

On the job around the clock 24/7: Fire detection systems

MobiCall. Unified Event Communication

Fire Alarm Network Reference

Inveron Hazard management system

Technologies Hazard management system. Inveron Hazard management system

Line Smoke Detector LRMX

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc.

For Complete Fire and Gas Solutions

Heating with wood pellets kw

Quickstart Guide. Fire Alarm System Design

Product Catalogue 2008 / Fire Alarm Systems

Remote alarm unit Art. Nr.:

Product Datasheet MM8000 MP3.10 Management Station

Process Alarm Solutions

Forward-looking and energy effi cient Biomass heating

Healthy. Atmosphere. for Pigs and Poultry. for a

Integrated Security Solutions

Modular Fire Panel 5000 Series Just as flexible as your plans

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

C Command. Engine monitoring that puts you in control

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

Product Catalog Fire Alarm Systems

HAWK 8000 CONNECTED BUILDING MANAGEMENT

Panel Mounted Fault Annunciator Series

THE NEXT SMART HOME GENERATION

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

FIRE PROTECTION ENCLOSURES

Different types of Fire Alarm System

Condition monitoring using FAG products. Technical Product Information

Fire and Gas Monitoring Panel ST7-HV

SIMPLICITY BY DESIGN M52 CONTROLLER

Heating with log wood

Session VI Smart safety systems

AIS750 Series Alarm Annunciator

- HSDK. to Integration. Honeywell Integrated Security Consultants Event, July Rev 10/07/11

TELECOMMUNICATION. Telecommunication. Wireless Phone

English. Efficiency. HERZ pellet boiler with condensing technology. ɳ over 106% COndEnSATiOn

Fire Alarm Control Panel IQ8Control C/M. Operation Instruction GB / AA

IntesisBox BACnet/IP Server - Notifier ID3000 series

designed for rail 5000 Series

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

CCU Family of Modules

Dear Customer! FIRE FIGHTERS CALL STATION - INTRODUCTION

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

Mine Automation Technologies. know-how performance reliability

Am I safe working in this building?

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Success Story Claas. Ein WinGuard Reference Project

SeCom. Combining communication and security in retirement- and nursing homes

Intelligent Fire Detection & Alarm and Mass Notification System.

One system, many options

DCS DSS OSS EIB OBPS OPTS FDS AFSS

Operation and Installation Instructions

MobiCall. Unified Event Communication Platform

Spark Extinguishing Systems. Extinguish BEFORE Ignition. Fire Protection. Measuring Technology. Service. Fagus-GreCon Greten GmbH & Co.

idware Idware Remote Site Monitoring Solution

Made possible by an innovative licensing scheme, which allows individual hardware configuration, up to the maximum configuration:

Case Study. Case Study. Pull Forward: Monitoring Drive-Thru Service Efficiency in McDonald s Restaurants. United Atlantic Systems (UAS) McDonald s

Screw Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig

Universal Monitoring System. TrapServer Description

PA/VA solutions for transport industry

Operation and Installation Instruction

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Building system automation. How to use

ID3000 intelligent. fire alarm panel

FST DFS Notifier Onyx 640

INTRON-D plus. Alarm and Warning Function. Automatic and/or manual triggering of alarms and warnings to protect human lives and to evacuate people.

Conveying Equipment. Conveying Systems for Plastics Processing Plants. world of innovation

SAFETY AT SCHOOLS. We supply sound, not equipment. the integration of intercom and voice alarm systems makes schools safe.

Transcription:

Concepts for the secure networking of large building complexes

Secure conditions: competence & responsibility Due to our extensive product portfolio, you can realize projects with us which, because of their complexity, meet the highest requirements of the fi re alarm system. Our system concept is driven accordingly an thus guarantees smooth coordination of all technology used. With very large objects, it is important for planners, installers, and operators to make use of the known fl exibility of our systems as well as the proverbial Esser reliability, in order to allow the installation of the fi re detection technology during expansion and reconstruction of already existing properties in a simple and easy way. Of course our product range is provided with acknowledged certifi cations so as to be able to realize some of the largest objects worldwide. All control panels and detectors are tested and authorized in compliance with EN-54. The larger an object is, the more important it is to select a suitable fi re alarm system which is resistant to malfunction and other disturbance variables. Here again you are making the right decision by selecting our products. Technically demanding and extensive large projects are successfully realized worldwide with our innovative products and system solutions. Here we always offer our partners the best possible technical support and together develop the optimal system solution for any type of application. The following examples of internationally realized objects present only a selection of the possibilities our products have to offer. Fibre optic converter esserbus-plus Repeater 2

The flexible and efficient The, a loop which can tolerate short circuits and interruptions, combines several control panels and network components into a hierarchy-free network for economical and convenient monitoring of extensive building complexes. Indicating and control operations are easily possible and trouble-free via the, even across multiple control panels. Due to the modular construction, all changes in the object can be programmed quickly and easily from a single point. Even the confi guration of master panel (MP) and slave panel (SP) is possible at any time via the programming software. At a bit rate of 62.5 kbaud, up to 16 devices can communicate with each other via the net; at a bit rate of 500 kbaud, the number increases to 31 devices. ranges Depending on object s particular circumstances, the can be operated using even the most diverse types of cable. If a bit rate of 62.5 kbaud is selected, traditional telephone cable - IY (ST) Y nx2x0.8 mm is suffi cient. For the high bit rate of 500 kbaud, IBM Type 1 and/or Belden 1634A cable must be used, which are widely used in data processing. The maximum distance between 2 loop devices is 1000m. If that is not far enough, the distance can be tripled by using two repeaters. If fi bre optic and corresponding converters are used, even distances of up to 20km between two devices can be realized. Maximum 1,000 m Repeater Maximum 3,000 m Fibre optic converter Maximum 20,000 m 3

Client Client Server Server to Property Fire Department Control Center FACP 8007 Serial Interface Main Panel in MP SP MP SP MP SP Modem LGH 9600 MP SP Gateway with 20 Control Panels Control Center MP SP MP SP Property 2 Property 3 Telephone Line Serial Connection Ethernet 4

Interconnection of large systems with existing infrastructure Within a range of approx. 400 km 2, information (status of zone, detector and control groups) of six widely distributed properties with a total of approx. 120 fi re alarm control panels and 7,500 detectors is transmitted to a control center. At the same time, all information is switched onto a redundant management system. Modem LGH 9600 Serial Interface (SEI), Part No. 784856 MP-SP protocol converter Gateway, Part No. 788730 The individual networks work completely autonomously; that is, announcements are transmitted to the control center and/or to the management system, but not to the other networks. All operations of the fi re alarm system are possible from both the control center and the management system. The additional texts of the individual networks are available centrally in the gateways and can be displayed both in the fi re department control center as well as in the management system. The existing internal telecommunication network is used as a medium for the transfer of the respective data. 5

Server 1 Redundant Server 2 Client 1 Client 2 Transmission unit 1 Transmission unit 2 Main Panel 2 Main Panel 1 SEI 2 SEI 4 Main Panel 2.1 Main Panel 1.1 SEI 3 SEI 1 Connection via Transponder Serial Connection Ethernet Property 1 Property 2 6

Maximum redundancy in monitoring and alarms In a large university clinic, the fi re alarm systems networked in the individual clinic buildings are to be switched over to a WINMAGplus central management system. Both the connection of the individual systems as well as the management system itself are redundant (red and yellow lines) for security reasons. The clinic s own pre-existing Ethernet network is used for this. Transmission Unit to Fire Department IQ8Control Fire Alarm Control Panel RS232, Part No. 013405.10 The networks of both properties work autonomously. Via WINMAGplus, however, the user has the option to access all control panels. For security reasons, the fi re announcements of the individual networked fi re alarm systems are additionally transferred to the main panels of the other networks via esserbus transponders (blue line). In this way, an emergency call can still be made over the redundant path even if there is a breakdown of one transmission device. Currently, the entire fi re alarm system consists of 50 fi re alarm control panels with a total of 9,000 detectors. The further expansion of a third and fourth is currently in progress. The fi nal confi guration will contain approx. 80 fi re alarm control panels and 12,000 detectors. 7

Central Control Center Intranet Property 1 Property 2 Serial Interface for WINMAGplus esserbus-plus Property 3 Property 4 Serial Connection Ethernet 8

Real-time monitoring of 10,000 detectors via intranet The fi re alarm systems in the headquarters of a large telephone company are centrally switched over to the WINMAGplus management system. These fi re alarm systems are distributed in business locations throughout the entire country. The fl exibility of WINMAGplus allows the creation of a company s own individual internal user interface with different security levels and user-specifi c access rights. At the same time, WINMAGplus allows the display and access to all fi re alarm systems of the respective properties. RS232, Part No. 013405.10 Serial Interface for WINMAGplus, Part No. 784847 Serial Interface (SEI), Part No. 784856 Individual fi re alarm control panels or complex networked systems can be present in these 40 offi ces. Individual systems are not connected via the serial module but rather via the clearly more cost-effective WINMAGplus interface. Transmission of the announcements occurs exclusively via the company s own Ethernet. 9

FO Ethernet IQ8Control Gateway Property 1* SEI Property 1 IQ8Control Gateway Engineering Room Transmission Unit Fire Department Key Box Fire Department Route Maps - Depot WINMAGplus Server opt. ESPA 4.4.4 Redundant Server IQ8Control Gateway Property 2* Property 2 Connection via Transponder Serial Connection Ethernet Fibre optic (FO) Direct Connection *The IQ8Control Gateway is a project-specific solution and requires a release from Neuss. 10

Fail-safe coupling via FO loop The fi re alarm systems of two properties are connected to each other with the corresponding converters via an FO loop which can tolerate wire breakage and short-circuits. Additionally, all information is made available in a control panel in the engineering room. This is made possible by IQ8Control Gateways which have an Ethernet interface and which can gather, display and forward the information of all fi re alarm systems. System-wide operations are also possible with the aid of these gateways. IQ8Control Gateway with Ethernet Interface FO Switch In addition, the information of the two properties are switched over to a redundant WINMAGplus management system which is equipped with a notifi cation option in order to pass on defi ned messages via DECT telephones. 11

FO Loop FO Ethernet WINMAGplus Server 1 WINMAGplus Redundant Server 2 Central Monitoring WINMAGplus Client Tower 1 WINMAGplus Client Tower 2 IQ8Control Gateway Tower 1* IQ8Control Gateway Tower 2* 12 Serial Connection Ethernet Fibre optic (FO) Tower 1 Tower 2 *The IQ8Control Gateway is a project-specific solution and requires a release from Neuss.

Secure networking of large building complexes The fi re alarm systems of several high-rise building complexes are switched over to a control center via an FO loop network which can tolerate to wire breakage and short-circuits. In addition to the redundant WINMAGplus management system, an IQ8Control Gateway is located in the control center as a combined indicator and control panel. In each case there is also an IQ8Control Gateway located in the high-rise buildings engineering rooms. These enable the status display and operation of both fi re alarm systems. IQ8Control Gateway with Ethernet interface FO Switch RS232, Part No. 013405.10 The WINMAGplus clients in the engineering rooms allow an additional visualization with the possibility of storing synchronized emergency action plans for the buildings. The fi nal installation will encompass about 70 fi re alarm control panels with almost 45,000 detectors. 13

Gateway Building Management System WINMAGplus Touch Panel SEI Network Controller Honeywell Security Network Communication Transponder esserbus Extinguishing Control Panel Serial Connection Ethernet 14

Connection to the building services management system Information from the IQ8 fi re alarm system and the intrusion alarm system is switched over to a common WINMAGplus touch operating unit which was equipped with an individually designed user interface. With the fi re alarm system, the connection occurs via the Serial Interface and via a special network controller for the intrusion detection technology. In addition, the data of both networks is transmitted serially to a BACnet Gateway which respectively encodes the data and forwards it to a superior building management system. Multiprotocol Gateway, Part No. 7850xx Network Controller Serial Interface (SEI), Part No. 784856 The operation of both systems is thus possible both locally via the WINMAGplus Touch Panel as well as via the control center. In addition to the gateway shown here, other interfaces for OPC, LONTalk, Modbus IP or EIB / Instabus are available. Operation via the building management system is dependent on the interface used. 15

Your specialist Novar GmbH a Honeywell Company Dieselstraße 2 41469 Neuss, Germany Phone: +49 2137 17-0 (Administration) Phone: +49 2137 17-600 (Customer Service Center) Fax: +49 2137 17-286 Internet: www.esser-systems.com E-mail: info@esser-systems.com Honeywell Life Safety Austria GmbH Lemböckgasse 49 1230 Vienna, Austria Phone: +43 1 600 6030 Fax: +43 1 600 6030-900 Internet: www.hls-austria.at E-mail: hls-austria@honeywell.com Part No. 795883.G0 February 2009 Subject to change without notice 2009 Honeywell International Inc.