Challenger V8 4-Way Relay Card TS0840 TECOM. Installation Guide. Revised! see Protective Earthing Addendum O O O O. Relays: Dimensions ( PCB Card )

Similar documents
P0WER SUPPLY & OUT AUX PWR INPUTS IN O O O O O O RELAYS 1-4 RELAYS 5-8

Challenger Version 8 Programming Relays.

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

IEI NETWORK INTERFACE MODEL TS2040

MEDI-MINDER USER MANUAL

Challenger10 Users Manual

MEDI-MINDER USER MANUAL

Networked Access Control Panel. Installation Guide

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

10yr O2NE & Safe-Ox. User Manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

The EN54 Part 2 & 4 Fire System

General Routing Interface

AS DIGITAL FIRE PUMP CONTROLLER

Power Wave Zone Alarm Panel V8.5. Installation Manual

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

TECOM SYSTEMS NETWORK MASTER

Interface Modules for SENTRI

Helios W.E.S & 2000 (Wireless Emergency Stop) User Guide. E6, Version 1.2. Helios Global Tech Ltd.

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

Planning Elevator Relay Groups Programming Millenium for Windows Software

Brivis Touch Controller. Installer Manual

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Medi-Minder Guardian USER MANUAL

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Challenger V8 & V9 User Manual

Challenger Series Users Manual

FEC400 Series. Installation Manual

Mobile App User Guide

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

MTRA-FSP Level Control Relay. Installation & Operation Manual

Beacon 800 Gas Monitor Operator s Manual

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

MD12-1 Vehicle Loop Detector

USER MANUAL ARHS60X ARHS60X-L 600 // SLIDEOUT HOOD

Model 17A00 Expansion Enclosure

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Installation, Operating and Maintenance Manual

Application, Installation, Operation & Maintenance Manual

USER MANUAL FOR OPERATING SYSTEM

EXTINGUISHING AGENT RELEASE MODULE

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

P2267 NETWORK INTERFACE

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

IDP-Zone-6 Six Zone Interface Module

MBCE-110/230FR Flame Sensor Module

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

(Updated Defaults) (Covers Ver: 8.64 and above)

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

Fratech Multipath-IP

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

SC-6 Six Supervised Control Module

CORPORATION PTY LTD MEDI-LINK

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

IGD.CO.UK

Manual for QX0201 Push Button

AL800ULADA. NAC Power Extender. Installation Guide

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

4100U City and Relay Cards Installation Instructions

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

WARNING FIRE DOOR CLOSING

AL600ULADA. NAC Power Extender. Installation Guide

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

LC-Series Controller 1-4 Channel Operation and Maintenance Manual

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Brivis Inverter Icebox

SMARTWALK DEMENTIA WANDERING SYSTEM

Remote Air Cooled Condensers C2 Series

Challenger10 Administrators Manual

600 Range Dialer Installation Manual. Version 1.0

MD12-2 Vehicle Loop Detector

Drying Cabinet With Timer

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

Sierra Series 900 Single & Dual Channel System. Instruction Manual

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

C-Bus Four Channel Analogue Output Unit Installation Instructions

MELBOURNE BBQ CENTRE PARKLAND BBQ SERIES

DEMAND CONTROL OPTION PCB

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

PTE0705 Electric Fence Monitor

STROBE / SOUNDER INTERFACE

Booster Power Supply Manual

System Manual W A R N I N G. PC6O1O Software Version 2.1

TRX MAINS CONNECTION DIAGRAM

Beacon 410A Gas Monitor Operator s Manual

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Transcription:

Revised! see Protective Earthing Addendum Installation Guide J2 O O J1 4 IN 3 RELAY OUTPUTS EXPANSION 2 J3 1 O O Relays: A 4 way Relay Module provides four 1 Amp single pole Relays with connection terminals to the Common (C), Normally Open (NO), and Normally Closed (NC) contacts. If fitted to an 8-32 input DGP two relay modules can be connected together in daisy-chain fashion to provide up to 7 relays on TS0020 to TS0024 DGPs or up to 8 relays on TS0820 to TS0824 DGPs. When fitted to a TS0015 (V6.0Y or later) Challenger Alarm Panel, the relay module provides 3 relays. Relays 1, 3 and 4 can be used. Relay 2 is not used, as the Strobe output on the Panel follows relay 2. When fitted to a TS0816 (Version 8 or later) Challenger Alarm Panel, the relay module provides 4 relays. Dimensions ( PCB Card ) Size B PCB: 80 x 52 mm Current Consumption: The 4 way Relay card draws no current on standby, and a total of 100mA with all 4 relays active. Version 8. 4 Way Relay Card - Model : Issue I, Revision I: August 1994 1

Wiring: Interconnection between the Relay module and the different Challenger equipment is detailed below. Version 8. Challenger Alarm Panel. TS0816 or Version 8. 8 Input Data Gathering Panel. TS0820, TS0822, TS0823, TS0824 Cable: LEV8-10-500P (Supplied with ) 4 Way Relay module J2 Version 8 Panel J14 OR 8 I/P DGP J8 (O/P) 1 +12 Volts 1 2 Relay 1 2 3 Relay 2 3 4 Relay 3 4 5 Relay 4 5 6 Relay 5 6 (Not used on TS0816 Alarm Panel) 7 Relay 6 7 (Not used on TS0816 Alarm Panel) 8 Relay 7 8 (Not used on TS0816 Alarm Panel) 9 Relay 8 9 (Not used on TS0816 Alarm Panel) 10 0V 10 Version 6 Challenger Alarm Panel. TS0015 Cable: LETS0043 ( Ordered separately) 4 Way Relay Module J2 V6 Chall Panel J8 2 Relay 1 7 4 Relay 3 6 5 Relay 4 5 1 +12 Volts 2 8 Input Data Gathering Panel. TS0020, TS0022, TS0023, TS0024 Cable: LETS0040 ( Ordered separately) 4 Way Relay module J2 8 I/P DGP J7 (O/P) 1 +12 Volts 1 2 Relay 1 2 3 Relay 2 3 4 Relay 3 4 5 Relay 4 5 6 Relay 5 6 7 Relay 6 7 8 Relay 7 8 Interconnection between two modules. Cable: LEV8-10-500P ( Supplied with ) 4 Way Relay module J2 4 Way Relay module J3 - Expansion 1 +12 Volts 1 2 Relay 5 2 3 Relay 6 3 4 Relay 7 4 5 Relay 8 5 6 Not Used 6 7 Not Used 7 8 Not Used 8 9 Not Used 9 10 0V 10 2 IN.P65: Issue I, Revision I: August 1994

Mounting: TS0816: TS0015: DGP 8-32: TS0304: The has to be mounted in a separate enclosure and is connected with the cable supplied. The has to be mounted in a separate enclosure and a special cable (LETS0043) must be used. The is mounted on existing standoffs in the DGP enclosures and connected to the TS082x DGP PCB with the cable supplied. If connecting to a TS002x DGP a special cable (LETS0040) must be used. (Where 'x' is TS0820, TS0822, TS0823 or TS0824.) Separate Enclosure. V6 DGP Box 360 x 260 x 75mm with mounting for 1 Size "A" PCB, and 4 Size "B" PCBs or 2 Size "Double B" PCBs. Note: The is a Size "B" PCB. ( See table below ) Maximum 4 Way Relay Cards per Challenger product. Maximum Cards. Maximum Usable Relays. TS0816 V8: 1 4 TS0820/TS0822 V8: 2 8 TS0015 V6 / V7: 1 3 TS0020/TS0022: 2 7 Installation Summary: CAN CONNECT TO CABLE INSTALLATION TS0816 V8 Alarm Panel. TS0820/TS0822 V8 DGPs. interconnection. Cable supplied Cable supplied Cable supplied Separate enclosure required. Up to 2 s can be fitted in TS082x enclosure depending on what other cards are fitted. TS0015 Alarm Panel (V6 / V7). TS0020/TS0022 8 I/P DGP. LETS0043-1M LETS0040-260P Separate enclosure required. Up to 2 s can be fitted in TS002x enclosure depending on what other cards fitted. Note: Clocked Relay/Open Collector Cards and 4 Way Relay Cards cannot be used together on the same product. Version 8. 4 Way Relay Card - Model : Issue I, Revision I: August 1994 3

Enabling and Programming: Program Relay Assignments. Refer to the Challenger Programming guide section on Numbering to determine system relay numbers. Map relay numbers to Event numbers and/or timezones as required. Relay function can also be inverted or programmed to be active or inactive during the timezone. If connected to the Challenger Panel, "Number of Relay Controllers" in Installer menu Option 7 must be set to 0. Connection Diagrams: Challenger Panel PANEL TS0015/TS0816 Cable. See table on previous page. J2 EXP. 8 Input DGP 8 I/P DGP Cable. See table on previous page. J2 J2 EXP. EXP. LEV8-10-500P (Supplied) 4 IN.P65: Issue I, Revision I: August 1994

N4131 Please note, this product conforms to the standards set by Standards Australia on behalf of the Australian Telecommunications Authority (AUSTEL) and the Spectrum Management Agency (SMA). WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. The Challenger is designed and manufactured by: Interlogix Australia Pty Ltd 646 Whitehorse Rd MITCHAM VIC 3132 A.B.N. 84 086 771 404 PH: 03 9259 4700 FX: 03 9259 4799 C Interlogix Australia 2001 Version 8. 4 Way Relay Card - Model : Issue I, Revision I: August 1994 5