CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

Similar documents
CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

CWA4 Chilled & Hot Water Fan Coil

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

FCC Fan-Coil Units High-Performance, Vertical

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Product Specifications. Vertical Floor Consoles By First Co.

catalog CDV Fan-Coil Units High-Performance, Vertical

Commercial High-Efficiency Condensing Units

SKYPAK II, 3 Ton Series, gives you a

Q-TEC QC-Series Chilled Water Air Conditioner

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

C13-Series Engineering Guide

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

SpaceKeeper Console (SKC)

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Q-Tec TM QC-Series Chilled Water Air Conditioner

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

SKYPAK II Heating & Cooling Self Contained Packages

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

PAJ3. Product Specifications

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Concealed Ducted Split Series R-407C MBH

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

GUIDE SPECIFICATIONS AQUARIUS ii

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

VERTICAL FAN COIL UNITS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TECHNICAL SPECIFICATIONS

VertiCool Aurora Engineering Guide

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

MERIT SERIES Up Flow / Horizontal

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

General Description. Operation

Ruud Standard Efficiency Air Handler

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

MERIT Series R-410A - Upflow / Horizontal

Incremental Comfort Conditioners

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Rheem Standard Efficiency Air Handler

AIR HANDLERS AIR HANDLERS

SeasonMaker ThinLine Fan-coil Units

Portable Vertical Air-Conditioning and Heating Systems

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Call us today! (800)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Ruud Standard Efficiency Air Handler

Call us today! (800)

Call us today! (800)

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

HIGH EFFICIENCY AIR HANDLER

technical guide Water-Cooled Self-Contained Units

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Indoor Air Handlers with Compressors MVS and MVW

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Submittal Data Performance Data Electrical Data

4YCC3048A3096A /3/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

2 shp 13 lc 1 36 t - 1 a

Rheem High Efficiency Air Handler

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Transcription:

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3

HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua Model Number: CFFWA4P-16-1-U Part 1-General 1.01 System Description Multiaqua Chilled Water Fan Coils are manufactured with galvanized steel and high impact molded polymers. 1.02 Quality Assurance A. Certified in accordance with U.L. Standard 95, latest version (U.S.A.) B. Manufactured in a facility registered to ISO 9002, Manufacturing Quality Standard. C. Fully electrically tested at the factory. D. Damage resistant packaging. 1.03 Delivery, Storage and Handling A. Packaged and readied for shipment from the factory. B. Controls shall be capable of withstanding 150 F storage temperatures in the control compartment. C. Stored and handled per manufacturer s recommendations. Part 2-Product 2.01 Equipment A. General: 1. Unit shall be a factory assembled and tested chilled and hot water fan coil. 2. Shall be assembled with high quality. 3. Contained with the unit shall be all factory wiring, piping, associated controls. B. Unit Cabinet: 1. Composed of galvanized steel with baked polyester powder and high impact polymers. 2. Coil Compartment shall be internally insulated to ensure quiet operation. C. Fan Motors: 1. Shall be available in 208/230-1-50/60 VAC. 2. Fan motors shall be three speed, direct drive, and PSC type. 3. Totally enclosed. 4. Internal overload protected. 5. Unit shall contain a swing motor to distribute the discharge air. D. Blower Wheels: 1. Blower wheels are double entry and dynamically balanced. E. Water Coils: 1. Manufactured with water coils containing 3/8 copper tubing mechanically bonded to aluminum fins. 2. Coils shall be factory tested to 350 psig. 3. Maximum inlet water temperature 180 F 4. Primary coil and Secondary coil connections are opposite ends and are non reversible. 5. Pressure independent flow control required on both coils to not exceed max flow for each coil. i. Consult primary coil and secondary coil data for proper sizing F. Drain Pan: 1. All drain pans shall be coated on both the interior and exterior with baked polyester powder to resist corrosion. 2. The exterior of all drain pans shall be insulated with closed cell insulation to prevent condensation. 3. Pans shall contain drain tubing that is accessible from the back, bottom and side of the unit. G. Filters: 1. Unit shall contain washable filters. 2

Part 3-Controls and Safeties 3.01 Controls A. Fan coils shall be completely factory wired and tested. B. Unit shall include a terminal block that is capable of incorporating a field supplied 24 VAC thermostat. C. Controls shall be capable of incorporating a field supplied three speed fan speed switch and or thermostat. 3.02 Safeties A. Fan coil shall contain a field renewable fuse on the secondary voltage side of the transformer. B. Fan coil shall contain a non renewable thermal protector on the primary voltage side of the transformer. Part 4-Operating Characteristics 4.01 Electrical Requirements A. Electrical shall include a terminal block for both high voltage and low voltage. B. Electrical power supply shall be rated to withstand 120 F operating ambient temperatures. Part 5- Definitions 5.01 Abbreviations A. = Cubic Feet per Minute B. DB = Dry Bulb Temperature C. EWT = Entering Water Temperature D. GPM = US Gallons Per Minute E. MBH = BTU X 1000 F. SC = Sensible Cooling G. TC = Total Cooling = Sensible + Latent H. WB = Wet Bulb Temperature I. WPD = Water Pressure Drop in feet of head J. db = Decibel Level K. m = Meter L. In = Inches M. FP I= Fins per Inch N. OD = Outside Diameter O. ID = Inside Diameter P. MCA = Minimum Circuit Amps Q. MOP = Maximum Over current Protection R. LBS = Pounds U.S. 5.02 Measurements A. All measurements with regard to length, width, and height shall be in inches. 3

208/230-1-50/60 CFFWA4P-16-1-U Product Specifications Physical Data Model Number Height (in) Length (in) Depth (in) Weight (lbs.) Primary Coil Rows FPI Water Inlet / Outlet OD (in) Secondary Coil Rows FPI Water Inlet/ Outlet OD (in) Drain Connection ID (in) CFFWA4P-16-1-U 11.3 88.5 28.3 156.5 3-14.875 1/14.875 1 tube *All dimensions rounded up to nearest tenth of an inch. All dimensions are as the unit is horizontal/ceiling mounted. Electrical Data Model Number High Speed Volts/ Phase/ Hertz Fan Motor (Qty) Watts Fan Motor Full Load Ampacity Fuse or HACR Circuit Breaker Per Circuit MCA MOP CFFWA4P-16-1-U 1157 (2)182 2.7 3.4 6.0 4

CFFWA4P-16-1-U Chilled Water Performance Data CFFWA4P-16-01-U COOLING CAPACITIES (Primary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 36046 5.0 SC 26491 WPD 8.7 TC 39395 6.0 SC 28129 1157* 42 WPD 12.2 TC 42270 7.0 SC 29402 WPD 16.3 TC 44584 8.0 SC 30449 WPD 20.8 *High Speed CFFWA4P-16-01-U COOLING CAPACITIES (Primary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 32139 5.0 SC 25004 WPD 8.7 TC 35146 6.0 SC 26454 1157* 45 WPD 12.1 TC 37620 7.0 SC 27548 WPD 16.2 TC 39486 8.0 SC 28372 WPD 20.7 *High Speed Recommended minimum flow rate for the primary coil at > 2 fps is 3.5 gpm Recommended maximum flow rate for the primary coil at < 6 fps is 9.75 gpm 5

CFFWA4P-16-1-U Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered (Primary Coil) 50 1157 5.0 8.1 35535 44397 53296 62223 71173 80140 89119 98107 107100 116096 6.0 11.3 36854 46054 55287 64548 73830 83129 92440 101759 111084 120412 7.0 15.0 37820 47264 56740 66241 75762 85299 94848 104405 113967 123533 8.0 19.2 38549 48176 57833 67513 77213 86927 96652 106386 116125 125868 (Primary Coil) 60 1157 5.0 8.1 26826 35667 44546 53456 62389 71342 80309 89286 98269 107257 6.0 11.3 27798 36976 46190 55433 64700 73985 83283 92592 101908 111228 7.0 15.0 28509 37932 47389 56874 66380 75904 85440 94987 104541 114099 8.0 19.2 29046 38653 48292 57956 67641 77343 87057 96781 106512 116247 (Primary Coil) 70 1157 5.0 8.0 18101 26921 35782 44674 53593 62532 71487 80454 89429 98408 6.0 11.2 18728 27885 37081 46308 55560 64831 74118 83416 92723 102035 7.0 15.0 19187 28590 38029 47497 56989 66500 76025 85562 95107 104657 8.0 19.1 19533 29121 38742 48391 58063 67752 77455 87169 96891 106619 (Primary Coil) 80 1157 5.0 8.0 9360 18161 27004 35881 44786 53712 62656 71613 80579 89552 6.0 11.2 9645 18783 27962 37173 46410 55669 64945 74234 83532 92836 7.0 14.9 9854 19238 28660 38113 47591 57090 66605 76132 85668 95211 8.0 19.1 10012 19581 29186 38820 48478 58156 67849 77553 87267 96988 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: CFFWA4P-16-01-U HOT WATER CAPACITY (Primary Coil) ENTERING AIR TEMPERATURE GPM ENTERING WATER TEMPERATURE 140F 70F DB / 60F WB 5.0 62955 6.0 65302 7.0 67009 8.0 68294 6

CFFWA4P-16-1-U Chilled Water Performance Data CFFWA4P-16-01-U COOLING CAPACITIES (Secondary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 16353 5.0 SC 13574 WPD 4.5 TC 18136 6.0 SC 14406 1157* 42 WPD 6.3 TC 19580 7.0 SC 15072 WPD 8.5 TC 20769 8.0 SC 15617 WPD 10.9 *High Speed CFFWA4P-16-01-U COOLING CAPACITIES (Secondary Coil) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 14419 5.0 SC 12860 WPD 4.5 TC 15953 6.0 SC 13589 1157* 45 WPD 6.3 TC 17234 7.0 SC 14183 WPD 8.4 TC 18256 8.0 SC 14655 WPD 10.9 *High Speed Recommended minimum flow rate for the secondary coil at > 2 fps is 3.5 gpm Recommended maximum flow rate for the secondary coil at < 6 fps is 9.75 gpm 7

CFFWA4P-16-1-U Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered (Secondary Coil) 50 1157 5.0 4.2 19811 24595 29419 34278 39164 44074 49002 53946 58901 63866 6.0 6.0 20437 25375 30350 35357 40390 45443 50514 55599 60694 65799 7.0 8.0 20917 25971 31061 36179 41321 46483 51660 56851 62051 67259 8.0 10.3 21297 26443 31622 36827 42055 47300 52561 57833 63115 68404 (Secondary Coil) 60 1157 5.0 4.2 15185 19943 24743 29580 34447 39338 44250 49179 54121 59074 6.0 6.0 15646 20558 25511 30497 35511 40548 45603 50674 55757 60851 7.0 8.0 15999 21029 26097 31196 36321 41466 46630 51807 56996 62194 8.0 10.3 16279 21402 26560 31747 36958 42189 47436 52696 57967 63246 (Secondary Coil) 70 1157 5.0 4.2 10549 15281 20059 24874 29722 34596 39492 44407 49336 54277 6.0 5.9 10846 15734 20665 25631 30627 35647 40688 45745 50816 55899 7.0 8.0 11074 16081 21127 26207 31315 36445 41595 46759 51937 57125 8.0 10.3 11254 16355 21493 26662 31857 37073 42307 47556 52816 58086 (Secondary Coil) 80 1157 5.0 4.2 5903 10610 15365 20161 24990 29847 34728 39629 44545 49475 6.0 5.9 6038 10902 15812 20758 25737 30741 35767 40812 45871 50943 7.0 8.0 6142 11126 16152 21214 26305 31420 36556 41708 46875 52053 8.0 10.3 6224 11303 16421 21573 26752 31955 37176 42413 47662 52923 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: CFFWA4P-16-01-U HOT WATER CAPACITY (Secondary Coil) ENTERING AIR TEMPERATURE GPM ENTERING WATER TEMPERATURE 140F 70F DB / 60F WB 5.0 34708 6.0 35767 7.0 36572 8.0 37205 8

CFFWA4P-16-1-U Chilled Water Performance Data CFFWA4P-16-01-U COOLING CAPACITIES (Both Coils) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 49427 10.0 SC 33542 WPD 7.9 TC 53053 12.0 SC 35180 1157* 42 WPD 11.1 TC 55980 14.0 SC 36540 WPD 14.9 TC 57861 16.0 SC 37400 WPD 19.2 *High Speed CFFWA4P-16-01-U COOLING CAPACITIES (Both Coils) EWT GPM ENTERING AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 44362 10.0 SC 31423 WPD 7.9 TC 47149 12.0 SC 32663 1157* 45 WPD 11.1 TC 49737 14.0 SC 33771 WPD 14.9 TC 51690 16.0 SC 34678 WPD 19.1 *High Speed Pressure independent flow control required on both coils to not exceed max flow for each coil Consult primary coil and secondary coil data for proper sizing Recommended minimum flow rate for both coils piped in parallel at > 2fps is 6.75 gpm Recommended minimum flow rate for both coils piped in parallel at < 6fps is 19.5 gpm 9

CFFWA4P-16-1-U Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered (Both Coils) 50 1157 10.0 7.4 43041 53878 64757 75670 86610 97573 108554 119549 130555 141569 12.0 10.4 43766 54773 65817 76890 87987 99103 110235 121379 132533 143695 14.0 14.0 44271 55394 66550 77731 88934 100153 111386 122630 133882 145141 16.0 18.0 44641 55848 67084 78343 89621 100914 112220 123534 134857 146185 (Both Coils) 60 1157 10.0 7.4 32372 43181 54035 64925 75845 86790 97754 108735 119727 130730 12.0 10.4 32905 43887 54908 65961 77040 88140 99258 110389 121532 132683 14.0 13.9 33275 44377 55512 66676 77862 89067 100288 111520 122762 134012 16.0 18.0 33547 44734 55953 67196 78459 89740 101034 112338 123652 134972 (Both Coils) 70 1157 10.0 7.4 21691 32473 43302 54171 65071 75998 86947 97912 108892 119883 12.0 10.4 22034 32992 43991 55025 66086 77171 88274 99393 110524 121665 14.0 13.9 22273 33352 44468 55614 66785 77976 89183 100405 111637 122878 16.0 17.9 22448 33615 44815 56043 67292 78560 89842 101137 112441 123754 (Both Coils) 80 1157 10.0 7.4 11000 21756 32562 43409 54290 65200 76133 87085 98052 109032 12.0 10.4 11156 22090 33068 44083 55127 66196 77286 88393 99513 110644 14.0 13.9 11264 22322 33419 44548 55703 66881 78076 89287 100509 111741 16.0 17.9 11344 22492 33675 44887 56122 67378 78649 89934 101229 112534 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: CFFWA4P-16-01-U HOT WATER CAPACITY (Both Coils) ENTERING AIR TEMPERATURE GPM ENTERING WATER TEMPERATURE 140F 10.0 76720 70F DB / 60F WB 12.0 77939 14.0 78776 16.0 79385 10

CFFWA4P-16-01-U Data MODEL # Fan Speed CFFWA4P-16-01-U L 875 M 975 H 1157 Wattage @ High Speed 580 11

CFFWA4P-16-01-U Dimensional Drawing 12