MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Similar documents
MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

CWA4 Chilled & Hot Water Fan Coil

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Product Specifications. Vertical Floor Consoles By First Co.

FCC Fan-Coil Units High-Performance, Vertical

Commercial High-Efficiency Condensing Units

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Commercial High-Efficiency Condensing Units

catalog CDV Fan-Coil Units High-Performance, Vertical

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Q-TEC QC-Series Chilled Water Air Conditioner

SKYPAK II, 3 Ton Series, gives you a

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Q-Tec TM QC-Series Chilled Water Air Conditioner

PAJ3. Product Specifications

VERTICAL FAN COIL UNITS

SKYPAK II, 3 Ton Series, gives you a

Concealed Ducted Split Series R-407C MBH

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

MERIT Series R-410A - Upflow / Horizontal

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

SpaceKeeper Console (SKC)

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

Call us today! (800)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

GUIDE SPECIFICATIONS AQUARIUS ii

SKYPAK II Heating & Cooling Self Contained Packages

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

SeasonMaker ThinLine Fan-coil Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MERIT Series R-410A - Upflow / Horizontal

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Call us today! (800)

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

13 GEP A L P - 1 A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

General Description. Operation

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

C13-Series Engineering Guide

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

MERIT SERIES Up Flow / Horizontal

Call us today! (800)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

SeasonMaker ThinLine Fan-coil Units

RAV Engineering Guide

Incremental Comfort Conditioners

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Specifications and Performance S2H

TECHNICAL SPECIFICATIONS

Bosch BVA Series Air Handler

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Samsung 360 Cassette, Single Zone, Split System

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

RGE 13 A T - 1 A

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

AIR HANDLERS AIR HANDLERS

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

2 shp 13 lc 1 36 t - 1 a

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

WJH4 Product Specifications

Transcription:

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11

HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000 BTUH Multiaqua Model Number: MH1WC4W-06-1-B Part 1 - General 1.01 System Description: Multiaqua Chilled Water Fan Coils are manufactured with galvanized steel and high impact molded polymers. 1.02 Quality Assurance: A. ETL certified in accordance with U.L. Standard 95, latest version (U.S.A.). B. Manufactured in a facility registered to ISO 9002, Manufacturing Quality Standard. C. Fully load tested at the factory. D. Damage resistant packaging. 1.03 Delivery, Storage and Handling: A. Packaged and readied for shipment from the factory. B. Controls shall be capable of withstanding 150 F storage temperatures in the control compartment. Part 2 - Product 2.01 Equipment: A. General: 1. Unit shall be a factory assembled and tested water fan coil. 2. Unit shall be assembled with high quality. 3. Contained within the unit shall be all factory wiring, piping, and associated controls. B. Unit Cabinet and Cover: 1. Cabinet is constructed of galvanized sheet metal. 2. Cover composed of high impact polymers. 3. Internally and externally insulated to ensure quiet operation. C. Fan Motor and Blower Wheel: 1. Available in 208/230-1-50/60 VAC. 2. Fan motor shall be three speed, direct drive, and PSC type. 3. Fan motor shall be totally enclosed. 4. Fan motor shall be internal overload protected. 5. Radial blower wheel is dynamically balanced. D. Air Distribution: 1. Unit contains one automatic discharge air louver. E. Water Coils: 1. Manufactured with water coils containing copper tubing mechanically bonded to aluminum fins. 2. Coils are factory tested to 300 psig. 3. Maximum design operating pressure shall not exceed 200 psig. 4. Coils are designed to accept an entering water temperature not to exceed 180 F. 5. Both coils are equipped with manual air bleed ports which drain into the units internal drain pan. 6. Secondary coil is in the re-heat position. Rev. 1.11

F. Drain Pan: 1. Constructed of galvanized steel with baked on polyester powder coating and closed cell insulation. 2. Unit contains internal lift pump and drain pan float switch designed for evacuating condensate to the fan coil unit drain port level only. G. Filters: 1. Unit shall contain two woven panel washable filter. H. Fresh Air: 1. Unit shall be able to receive up to 10% filtered fresh air. 2. Fresh air introduced shall be externally fan forced and externally controlled. Part 3 - Controls and Safeties 3.01 Controls: A. Fan coils are factory wired and tested. B. Fan coil includes a terminal block that is capable of incorporating a 24 VAC, field supplied thermostat. 3.02 Safeties: A. Fan coil contains a replaceable fuse on the low voltage side of the transformer. B. Coils shall be designed to accept an entering water temperature not to exceed 180 F Part 4 - Operating Characteristics 4.01 Electrical Requirements A. Electrical line voltage connections shall be made at the factory supplied terminal block. B. Factory wiring shall be rated according to UL listing at the time of manufacturing. 4.02 Installation in high ambient/high humidity environments A. Cabinets are internally insulated from the factory. However, if these units are installed in high ambient/high humidity environments, additional filed installed external cabinet insulation may be requir e d. Part 5- Definitions 5.01 Abbreviations: = Cubic Feet per Minute DB = Dry Bulb Temperature EWT = Entering Water Temperature GPM = US Gallons Per Minute MBH = BTU X 1000 SC = Sensible Cooling TC = Total Cooling = Sensible + Latent WB = Wet Bulb Temperature WPD = Water Pressure Drop in Feet of Head db = Decibel Level m = Meter In = Inches FP I= Fins per Inch OD = Outside Diameter ID = Inside Diameter MCA = Minimum Circuit Amps MOP = Maximum Over current Protection lbs. = Pounds U.S. 5.02 Measurements A. All measurements with regard to length, width, and height shall be in inches. Rev. 1.11

MH1WC4W-06-1-B Product Specifications Physical Data Model Number Weight (lbs.) Cabinet Dimensions (in) Cover Dimensions (in) Cooling Rows FPI Heati ng Rows FPI Water Inlet/Outlet (in) Drain (in) MH1WC4W-06-1-B 88.18 33.75 x 19.50 x 10.50 * 41.50 x 22.83 x 1.00 * 3/14 1/14 3/4 FPT ¾ Hose Conn. * See IOM for dimensional drawings. Model Number Electrical Data* Volts/ Phase/ Hertz Motor Watts Full Load Amps Fuse or HACR Circuit Breaker or Glass Fuse Per Circuit MCA MOP MH1WC4W-06-1-B 471 208/230-1 50/60 *All Electric Data Shown is at 60 Hz 115.50.63 1 Rev. 1.11

MH1WC4W-06-1-B Chilled Water Performance Data (PRIMARY COIL COOLING) MH1WC4W-06-1-B COOLING CAPACITIES (Primary Coil) EWT ENTERING AIR TEMPERATURE (F) GPM ( F) 80 D.B. / 67 W.B. 1.50 TC 12474 SC 10272 WPD 2.1 TC 15962 2.50 SC 11796 *471 42 WPD 5.7 TC 17211 3.00 SC 12317 WPD 8.0 TC 19066 4.00 SC 13092 WPD 13.7 MH1WC4W-06-1-B COOLING CAPACITIES (Primary Coil) EWT ENTERING AIR TEMPERATURE (F) GPM ( F) 80 D.B. / 67 W.B. 1.50 TC 11287 SC 9751 WPD 2.1 TC 14290 2.50 SC 11121 *471 45 WPD 5.7 TC 15401 3.00 SC 11576 WPD 8.0 TC 17036 4.00 SC 12253 WPD 13.6 Check www.multiaqua.com for the latest information. 5

MH1WC4W-06-1-B Hot Water Performance Data (PRIMARY COIL HEATING) (Primary Coil) 50 *471.75.5 9205 11546 13916 16313 18732 21169 23623 26089 28532 30908 1.00 1.0 10724 13472 16256 19072 21916 24735 27509 30284 33059 35830 1.25 1.7 11865 14914 18004 21088 24136 27190 30248 33308 36368 39427 1.50 2.3 12740 16018 19270 22519 25778 29043 32313 35585 38859 42132 (Primary Coil).75.5 6993 9323 11684 14071 16481 18910 21356 23815 26209 28585 60 *471 1.00 1.0 8123 10856 13626 16429 19260 22038 24809 27582 30354 33125 1.25 1.7 8970 12002 15074 18123 21166 24215 27269 30325 33382 36439 1.50 2.3 9619 12873 16103 19345 22597 25857 29122 32390 35660 38930 (Primary Coil).75.5 4756 7078 9430 11808 14210 16632 19070 21498 23878 26255 70 *471 1.00 1.0 5499 8219 10976 13766 16568 19333 22102 24872 27643 30412 1.25 1.7 6055 9070 12122 15150 18188 21233 24283 27336 30391 33445 1.50 2.3 6480 9704 12927 16163 19410 22664 25925 29190 32456 35724 (Primary Coil) 80 *471.75.5 2497 4811 7155 9525 11920 14334 16767 19159 21539 23916 1.00 1.0 2854 5561 8306 11084 13856 16619 19386 22154 24924 27692 1.25 1.7 3120 6119 9144 12168 15201 18242 21289 24340 27392 30445 1.50 2.3 3322 6527 9743 12973 16215 19465 22721 25982 29246 32511 Check www.multiaqua.com for the latest information. 6

MH1WC4W-06-1-B Chilled Water Performance Data (SECONDARY COIL COOLING) MH1WC4W-06-1-B COOLING CAPACITIES (Secondary Coil) EWT ENTERING AIR TEMPERATURE (F) GPM ( F) 80 D.B. / 67 W.B. TC 6015 1.00 SC 5452 WPD 6.5 TC 6632 1.25 SC 5791 *471 42 WPD 9.8 TC 7162 1.50 SC 6040 WPD 13.8 TC 7614 1.75 SC 6230 WPD 18.3 MH1WC4W-06-1-B COOLING CAPACITIES (Secondary Coil) EWT ENTERING AIR TEMPERATURE (F) GPM ( F) 80 D.B. / 67 W.B. TC 5445 1.00 SC 5125 WPD 6.5 TC 5967 1.25 SC 5462 *471 45 WPD 9.8 TC 6380 1.50 SC 5699 WPD 13.7 TC 6736 1.75 SC 5870 WPD 18.2 Check www.multiaqua.com for the latest information. 7

MH1WC4W-06-1-B Hot Water Performance Data (SECONDARY COIL HEATING Reheat Position) (Secondary Coil) 50 *471.75 3.6 6293 7842 9404 10977 12558 15180 16882 18587 20294 22002 1.00 6.2 6883 8583 10296 12019 13751 16646 18514 20385 22258 24132 1.25 9.3 7289 9091 10906 12731 14565 17638 19616 21596 23580 25564 1.50 12.5 7589 9466 11355 13253 15160 18360 20417 22476 23538 26601 (Secondary Coil).75 3.6 4799 6342 7897 9464 11040 13541 15239 16941 18645 20350 60 *471 1.00 6.2 5236 6929 8635 10352 12079 14839 16702 18569 20439 22310 1.25 9.3 5538 7333 9140 10959 12787 15716 17690 19667 21647 23628 1.50 12.5 5760 7629 9511 11404 13305 16355 18408 20464 22522 24583 (Secondary Coil).75 3.6 3927 4834 6384 7946 9517 11897 13592 15290 16992 18695 70 *471 1.00 6.2 4312 5270 6970 8681 10402 13027 14887 16751 18617 20486 1.25 9.3 4356 5569 7371 9183 11006 13792 15761 17735 19712 21691 1.50 12.5 4457 5790 7665 9551 11447 14348 16397 18450 20505 22563 (Secondary Coil) 80 *471.75 3.6 2091 3320 4865 6421 7988 10247 11939 13635 15334 17035 1.00 6.2 2275 3606 5300 7006 8721 11212 13068 14929 16793 18659 1.25 9.3 2296 3802 5597 7404 9221 11864 13830 15800 17774 19751 1.50 12.5 2344 3946 5815 7696 9586 12339 14384 16433 18486 20541 3320 Check www.multiaqua.com for the latest information. 8

MH1WC4W-06-1-B Chilled Water Performance Data (BOTH COILS COOLING) MH1WC4W-06-1-B COOLING CAPACITIES (Both Coils) EWT ENTERING AIR TEMPERATURE (F) GPM ( F) 80 D.B. / 67 W.B. TC 13098 1.50 SC 10793 WPD 1.1 TC 16925 2.50 SC 12475 *471 42 WPD 3.5 TC 18306 3.00 SC 13058 WPD 4.8 TC 20397 4.00 SC 13944 WPD 8.2 MH1WC4W-06-1-B COOLING CAPACITIES (Both Coils) EWT ENTERING AIR TEMPERATURE (F) GPM ( F) 80 D.B. / 67 W.B. TC 11891 1.50 SC 10244 WPD 1.1 TC 15207 2.50 SC 11762 *471 45 WPD 3.4 TC 16413 3.00 SC 12272 WPD 4.8 TC 18256 4.00 SC 13041 WPD 8.1 Check www.multiaqua.com for the latest information. 9

MH1WC4W-06-1-B Hot Water Performance Data (BOTH COILS HEATING) (Both Coils).75.4 9392 11741 14215 16658 19122 21603 24099 26607 29124 31647 50 *471 1.00.6 11063 13897 16767 19669 22597 25549 28520 31502 34401 37278 1.25 1.0 12329 15500 18711 21958 25235 28510 31713 34917 38121 41322 1.50 1.4 13313 16742 20213 23719 27167 30607 34051 37498 40944 44389 (Both Coils) 60 *471.75.4 7123 9471 11935 14369 16824 19298 21787 24288 26799 29317 1.00.6 8378 11199 14055 16944 19860 22801 25761 28707 31586 34462 1.25 1.0 9320 12473 15667 18898 22160 25390 28589 31790 34991 38190 1.50 1.4 10049 13458 16910 20386 23814 27249 30688 34131 37574 41016 (Both Coils).75.4 4837 7230 9631 12058 14506 16973 19455 21951 24456 26969 70 *471 1.00.6 5669 8477 11321 14198 17103 20033 22983 25886 28764 31640 1.25 1.0 6287 9424 12602 15818 19064 22262 25458 28656 31855 35053 1.50 1.4 6765 10155 13589 17031 20453 23883 27319 30758 34198 37638 (Both Coils).75.4 2534 4911 7306 9726 12167 14628 17105 19595 22096 24603 80 *471 1.00.6 2936 5731 8565 11431 14326 17246 20177 23056 25933 28809 1.25 1.0 3232 6353 9517 12719 15936 19125 22318 25514 28711 31907 1.50 1.4 3460 6832 10250 13666 17084 20510 23941 27377 30815 34253

MH1WC4W-06-1-B Data MODEL # Fan Speed MH1WC4W-06-1-B L 370 M 425 H 471 Wattage @ High Speed 115

MH1WC4W-06-1-B Sound Data MODEL # Fan Speed MH1WC4W-06-1-B db @ 1 m L 39 M 43 H 46

MH1WC4W-06-1-B Wiring Diagram

See Installation and Operation Manual for Dimensional Drawings 306 Hagood Street Easley, SC 29640 Ph.: 864-850-8990 Fax: 864-850-8995 www.multiaqua.com For Technical Assistance: 1-855-THNK-WTR (1-855-846-5987)