SC-F3G User Manual 1.0

Similar documents
COMMUNICATOR ET08 / ET081

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Firmware Enhancements and Additions from Version to Version

600 Range Dialer Installation Manual. Version 1.0

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IP & SMS Alarm Communicator

PERMACONN PM1030 Includes DI300. Installation Manual

GLOBAL. InstallatIon & operation manual

The future of security, secured IP by security professionals, for the professional security industry

ET082 GSM/GPRS COMMUNICATOR

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

ET083 2G/3G COMMUNICATOR

System solutions for every lift. Everywhere. Lift emergency EasyGate PRO and Lift1

Monitoring Solutions

Ontech GSM 9040/50. Reference Manual English -1 -

Сontrol panel Contact GSM-9N

Faster and smarter ways to protect what matters most. Our Next Generation portfolio

Manual GPRS Data Logger PCE-GPRS 2

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

1. Introduction. 2. Product overview

1. Functions of GPS locator ETLOC-30S 3

Kwêbeam GSM/Interface/Repeater Module

HRX Technical Manual. Version 1.2

Added password for IP setup page : Password must be in IP format!

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

IRIS Touch Engineering Manual. Version 1.2

rvm4c Installation Guide Remote Video Module

2G & 3G GSM Portable PIR Alarm

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

2G & 3G GSM Door Contact Alarm

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

T4000 Security Communicator

GSM RFID VOICE Alarm System

SCAN200E USER S MANUAL

MOBILE CALL GSM Alarm System User s Manual

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

Security designed for your lifestyle

DigiPlus INSTRUCTION MANUAL

IRIS Touch Engineering Manual. Version 1.2

Memcom Emergency Telephone

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

SMS GSM Alarm Messenger

HRX3000. Technical Manual

SolarSET GSM SolarSET GSM with a Beacon

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

Sentient. Downloader Manual D4854

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

2000 Series. Program Entry Guide. Control Panels

7 USE THE COMMANDS INTERNET VOICE MESSAGES RECORD VOICE MESSAGE DURATION OF VOICE MESSAGES 64

Smart Wireless Sensor

AZWG10200 ABUS PSTN/IP converter

IC60 Sintony 60 Intrusion Control Panel

Combined CAN Sensor Unit Temperature, Humidity and Smoke

BAT LTE SKU: IPD-BAT-LTE

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

HELPY CONTROLLER QUICK GUIDE

GSM/SMS/3G/4G. Remote Alarm Controller Digital Input Monitoring Alarm Unit. S130/S140/S150 User Manual. Ver 3.0. Date Issued:

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

Cold chain monitoring technologies. Facility monitoring

EWR2 WIRELESS SIGNAL REPEATER

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

1. User features of the GSM dialer

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

CAN unit for Analog Sensors

MPIP-620 GPS Vehicle Technical Specifications

Mobeye CM2410 GSM fire alarm communicator

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

USER MANUAL Mobeye ThermoGuard CM2200

GSM-SD WITH CALL,SMS,MMS MANUAL

Fratech Multipath-IP STU

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

Installation & Operation Manual March 2017 Rev. 4.1

GPS Vehicle Tracker (GPS+GSM+SMS/GPRS) User Manual (V1.0)


Typical applications include the vibration detector. Detection of vibrations and shocks

Contents. Contents

LevelSET S GSM Functionalities Instructions for Commissioning and Use

HOME MANAGEMENT GATEWAY

Outdoor Temperature Sensor

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Control panel «Contact GSM-5-2»

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

2G & 3G GSM Wireless Beam Alarm

AirFlow Sensor for Dry Contact connection

BURGLAR ALARM PANEL BS-468

Fratech Multipath-IP

MiNi Server environment MoNitoriNg SySteM

English. Doro CareIP Mobile. User Guide

Transcription:

SC-F3G User Manual 1.0

Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start... 5 7.1 Monitoring Receiver... 5 7.2 GPRS/3G SIM Card and APN... 5 8. Setting SC-F3G... 6 8.1 Installing the 3G DATA Setup application... 6 9. Configuring SC-F3G... 6 9.1 Information and administration area... 6 9.2 Module Status... 7 9.3 Modem and GPRS Settings... 7 9.4 Latest Events... 7 9.5 Monitoring Station Settings... 8 9.6 Input Settings... 8 9.7 Communication Event Codes... 9 10. Signal Transmission... 9 10.1 Description of the signal transmission... 9 10.2 Signal transmission logic... 10 10.3 Backup PSTN Line operation... 10 11. Controlling Output... 10 12. Mounting... 11 13. Technical Details... 13

1. Introduction The SC-F3G device is a modern remote monitoring communicator which operates on the 3G/2G mobile network, converts the Contact ID signals of alarm control panels into SIA DC-09 digital format and forwards to the predefined remote monitoring station s receivers. The signals are embedded in TCP or UDP packages and sent over WCDMA and GPRS network. If the mobile network connection is defected or the monitoring receivers are unavailable, the communicator provides a secondary option for report sending. In that case, the communicator switches to PSTN network. For increasing the security of signal transmission landline or another backup communicator can be connected to the PSTN input, if it fits to the standard alarm control panels communication. The security level can be also increased by the internal Li-Ion battery (LI-Ion 18650 2600mAh) that provides at least 5 hours operation in case the main power supply is lost 2. Functions Alarm control panel signal transmission over 3G network Automatic or predefined signal transmission logic Signal transmission triggered with contact inputs Status events reporting (supply failure, setup changed, etc.) Relay control by SMS commands Support for PSTN backup line Providing TCP/IP or UDP connection 3. Features Emulated phone line for alarm panel s phone line connection 2 contact inputs 1 controllable relay output Settings for 2 independent IP monitoring receivers Powered by Telit 3G UMTS cellular engine Small (0.2 kb) data package of UDP Test report setting from 30 to 600 sec Configuration and diagnostic via USB connection 2600 mah internal battery (optional) 4. Package Contents 3G communicator in plastic housing UMTS / GSM antenna USB mini B cable Manual and configuration software are available on the device s flash drive

5. Device Configuration Part ANTENNA SIM CARD HOLDER Li-Ion BATTERY (optional) DC POWER (DC+/DC-) DIAL CAPTURE PORT (TIP/RING) INPUTS (IN1, IN2) RELAY OUTPUT (REL) TELEPHONE (TEL/TEL) LANDLINE (PSTN/PSTN) USB CONNECTOR Description UMTS / GSM network antenna Connector: SMA, Impedance: 50 ohm, Frequency: 900/1800/2100 MHz For mobile network connection Type: M2M data card, Dimension: 2FF mini SIM Backup power supply In case of power supply outage or sabotage. Type: SANYO UR18650F Main power supply Rated voltage: DC 9-30V, Rated current: max. 1A Simulated landline for the alarm control panel s TIP/RING input Line voltage: 48V, Loop current: 25mA, Impedance: 300ohm Contact inputs (to DC-) for transmission of the signal of external switches Remotely controlled relay contact Maximum voltage: 48 VAC, Maximum current: 2A Landline output for home desktop phone Polarity independent. Backup PSTN line input If the communication to both monitoring receivers fails, the communicator will switch to the backup landline. Polarity independent. For parameters setting, the communicator must be connected to the computer through USB port. Type: USB mini-b

6. Status LED signals Red flashing SIM card is missing or the given PIN code is incorrect Red constant Signal strength of the antenna is under 20% Yellow flashing Yellow constant Green flashing Green constant Blue flashing Blue constant Data link is OK, but APN is incorrect or missing IP address/port Data link is OK, but the receiver is still not responding Idle mode, any receiver is available Sending test report Alarm control panel is on hook or dialing Sending CID signals to the monitoring station 7. Before You Start 7.1 Monitoring Receiver Make sure that the monitoring receiver is equipped with the system that allows receiving SIA DC-09 IP protocol messages before you start using SC-F3G and the following information should be obtained. IP address Port Protocol Test period 7.2 GPRS/3G SIM Card and APN For using the SC-F3G device a GPRS/3G SIM card is needed. During the configuration you need to add the APN (Access Point Name) of the GPRS/3G SIM card and the following possible configuration parameters. SIM PIN code APN User name Password

8. Setting SC-F3G 8.1 Installing the 3G DATA Setup application The installation file of 3G DATA Setup application can be found on the flash drive of the device. Installation steps: 1. Connect the SC-F3G communicator to the computer with the USB cable which can be found in the package 2. After the computer recognized the device as a normal flash drive, select and copy the 3G_DATA_setup.exe to the PC 3. Run the 3G_DATA_setup.exe 4. If it is needed, install the proper version of.net Framework (Prompt up window will warn you) NOTE: The configuration software is running only on MS Windows 7 operating systems or above! 9. Configuring SC-F3G USB connection steps: 1. Run the 3G_DATA_setup application 2. Connect the SC-F3G communicator to the computer with the USB cable which can be found in the package 3. The application verifies the USB connection 4. If the connection is established successfully, the application loads the stored configuration and module status from the device 9.1 Information and Administration Area Manufacturer logo: SECURECOM Product type with network standard (Europe/ North America): SC-F3G EUR Firmware version: V1.00 Open previously saved configuration. Save the current configuration into a file. Load the configuration into the device memory. USB connection status

9.2 Module Status SIM status Wait for SIM / OK / PIN request Network, signal (%) 3G/2G signal strength 1 (0-100%) Data connection WCDMA / GPRS data connection Monitoring station 1 Connection status of MS1 Monitoring station 2 Connection status of MS2 Dial capture Status of the dial capture hook INPUT 1 Status of INPUT 1: Active Inactive INPUT 2 Status of INPUT 2: Active Inactive RELAY Status of Relay: Active Inactive TELEPHONE Status of outgoing Telephone line: Active Inactive PSTN Line Status of incoming PSTN landline 1 The transmission is stable in case of minimum 30% signal strength. If the signal strength is lower than 30%, move the device to another place where the signal strength is higher. 9.3 Modem and GPRS Settings PIN code The PIN code of the inserted SIM card can be set, if the card is protected by PIN code. GPRS APN The APN of the SIM card must be set, regardless if it is using a public or non-public APN (Private APN) User Add the user name for the APN if necessary Password Add the password for the APN if necessary 9.4 Latest Events In this window the communication events of the SC-F3G device can be tracked.

9.5 Monitoring Station Settings The communication settings of the monitoring stations can be configured. IP address Port Protocol SIA prefix Object identifier Replace obtained identifier Dialed number by alarm system Link test period Link test code IP address or domain name of the monitoring station Port number of the monitoring station s IP address Selectable communication IP protocol: TCP, UDP 2 characters long SIA prefix, it can be used if the identifier of the connected alarm control panel is just 4 characters long, but the necessary identifier of receiver is 6 characters long The self identifier of the SC-F3G device (4 characters long). If it is enabled than the SC-F3G exchange the alarm control panel s identifier, to given self object identifier. YES: exchange, NO: not change The communicator forwards the signal in case of the alarm system is dialing this number. If this field is empty than the communicator forwards the signals independently of the dialed number by the alarm system. Sending test report to the monitoring station NO: test report is not sent 30sec 24 hours: the device sends test reports to the monitoring station by the given interval Any code can be defined. If this field is empty than the communicator sends Null Message, as defined by standard. 9.6 Input Settings The triggered input event destination can be selected. Sensitivity The switching time of the INPUT 1 and INPUT 2 can be set from 0.1 sec up to 10 minutes Contact type Physical setting. NO Normally Open NC Normally Close Event code The Contact ID code of the triggered event can be set. If the field stays blank than the input will be inactive. Reporting The triggered input event destination can be selected. MS1, MS2, MS1 or MS2

9.7 Status Event Codes Setting the Contact IDs for the communicator s own events. The event codes are standard 3 characters long ( 1 and 3, for event and restore are added automatically). If the event code field is blank, the event is not sent to the monitoring station. Supply failure Power supply is damaged or failed. PSTN failure PSTN is failed or disconnected. Setup changed The settings have been changed. Relay controlled Relay has been controlled. Reporting Destination receiver can be selected. 10. Signal Transmission 10.1 Description of the Signal Transmission The signal transmission between the alarm control panel and the monitoring station through the SC- F3G communicator works with following steps: The alarm control panel is dialing (over TIP/RING line) a preset phone number (e.g. 1111) The communicator detects the dialing and sends back the Handshake signal to the alarm control panel The alarm control panel sends the Contact ID of the first event code The communicator receives and converts the signals to digital format and forwards it to the active IP address of the monitoring station then waiting for the acknowledge message. The alarm control panel repeat the first Contact ID signal due the missing response of the communicator (the transmission time of the network is around 1-3 seconds) If the communicator receives the sign of the successful message sent by the IP receiver, it sends Kissoff sign (over TIP/RING line) as a response for the alarm control panel s repeated signal and it is recorded as successful event. The process restarts by sending the upcoming event code or the process is finished and the alarm control panel hangs up the line.

10.2 Signal Transmission Logic If both monitoring stations are entered, the direction if signal sending can be: Automatic: MS1 receiver is the primary, MS2 is the secondary, and every signal is forwarded to the MS1 until it is available. If MS1 is unavailable, every signal is forwarded to MS2. As the MS1 receiver will be available, so the test report is sent by MS1, it becomes primary again. NOTE: This function is working if the field Dialed number by alarm system is empty! Custom: You can define a number for both monitoring stations which is dialed by the alarm system. Using this option the alarm system will choose the specific receiver based on its dialing order independently of the availability of the receivers. NOTE: This function is working if the Dialed number by alarm system filed is NOT empty! 10.3 Backup PSTN Line Operation If the monitoring stations are unavailable via GPRS/3G network the communicator switches to PSTN line. In that case the line voltage is ended on TELEPHONE output, and the landline is only available for the alarm system. If any of the set receivers (MS1 or MS2) is available again, the communicator switches back to mobile network. In case of failure or power supply loss the basic communication way is the PSTN. The condition of PSTN line usage is that the phone line must be connected! 11. Controlling Output The relay output can be controlled by SMS commands. REL=period# Activates the REL/REL relay output. Period values: 1-100 (seconds) The basic state of the relay is NO (Normally Open) NOTE: It is possible to control the relay outputs by smartphone application, which requires a service with a monthly fee. Please contact to your distributor for further information!

12. Mounting 1. step: Fixing the back plastic back plate 2. step: Panel fixing and wiring

3. step: Releasing the wall fixing screw, flipping for the front plastic case fixing and screwing 4. step: Wall fixing with plastic cover

13. Technical Details Transmission paths 3G UMTS DATA (GPRS / EDGE / WCDMA) (4G LTE optional) Freq. Bands 2G: 900/1800MHz Freq. Bands 3G: 900/2100MHz Antenna: 3G SMA male PSTN landline backup Alarm transmission Interface application to monitoring software Dial capture interface to alarm panel PIN Inputs interface to alarm panel (contact and voltage type in paralell mode) Alarm protocols Faults reported to monitoring centre Self events reported to monitoring centre SECURECOM S2S interface (SIA to Sur-Gard) Two wire interface via terminal block Line voltage: 48V Loop current: 25mA Load impedance: 100-470 Ohm Contact type: INPUT to DCexternal pull-down impedance < 100 Ohm Voltage type: INPUT to DCexternal voltage trigger treshold > 5V (max. 30V) Dial capture side: SIA DC-05-1999: Contact ID Protocol 3G IP connection side: SIA DC-09-2013: Internet Protocol External power supply failure, PSTN failure Setup changed, Relay controlled Relay outputs Maximum operating voltage Maximum current rating 60V DC 2A Power supply Supply voltage Maximum current Nominal current 9-24V DC 1A @ 12V DC 100mA @ 12V DC