Similar documents
SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Residential and Light Commercial Ductless Systems Catalog

Modular Multi-position Air Handler

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Variable Speed Convertible Air Handler 5 Ton

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Cooling/Heat Pump Convertible Air Handlers

High Heat COP. High/Low Stage

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Variable Speed Convertible Air Handler 2 1/2 Ton

Cooling/Heat Pump Convertible Air Handlers

Unit Features & Benefits RQPM/RQRM Series

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Variable Speed Convertible Air Handler 4 Ton

Modular Multi-position Air Handlers

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

FBQ. DC Duct Heat Pump or Cooling Only

TECHNICAL SPECIFICATIONS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

FTQ. Daikin Inverter Ducted Heat Pump

DUCTLESS FULL LINE CATALOG

Commercial High-Efficiency Condensing Units

Condensing Units & Air Handlers

Modular Multi-position Air Handlers

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

TECHNICAL SPECIFICATIONS

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

LV Series. SEER 15+ Concealed Built in Heat Pump

Model: Ceiling Cassette V 9k-24k

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Ductless Split Systems Ceiling Cassette Heat Pumps

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Cooling/Heat Pump Convertible Air Handlers

Up to SEER 26.1 Wall Mount Heat Pump

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Modular Multi-position Air Handlers

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Samsung 360 Cassette, Single Zone, Split System

Ductless Split Systems Concealed Duct Heat Pumps

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. Fig. 1 - Unit 50VR -A

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Single - Zone Systems

Product Data INDUSTRY LEADING FEATURES / BENEFITS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Lennox Mini-Split Systems Year-Round Comfort and Performance

Modular Multi-position Air Handlers

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

13 SEER CONDENSING UNITS & AIR HANDLERS

Mini-Split Single-Zone and Multi-Zone Air Conditioners and Heat Pumps. Residential Catalog 2018

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Bosch BVA Series Air Handler

2017 LINE UP MINI SPLITS CATALOG

Technical Product Guide

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Vertical Upflow Horizontal Left Air Handlers

Ductless Systems. Right product for the right application

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

Specifications, Performance & Submittal

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Transcription:

Product Data -188-05 Split System (R-10A) Air Handler for Multi Split Inverter System 9,000 to,000 BTU/Hr Ceiling Concealed Type Indoor Unit: MXD8509A10N0 MXD851A10N0 MXD8518A10N0 MXD851A10N0 MXD85A10N0 016 Trane Pub. No. -188-05

It's Hard to Stop a Trane. Split System (R-10A, ) 16 SEER, Inverter System - 9,000 to,000 BTU/Hr Whatever their specific heating and cooling needs, people trust Trane to provide reliable efficient solutions. Trane Ductless Systems allow you to create a comfortable indoor environment in spaces where adding ductwork might be impractical or too expensive, or not as efficient as a ductless option. Retrofit a house that doesn't have a ducted system or where the central system is already at capacity. Bring efficient, economical comfort to new room additions. Provide spot heating and cooling that operates independently of the central system. Utilize ductless efficiency for new construction projects where ductless systems make more sense than a traditional ducted system. Easy to install Trane Ductless Systems offer flexibility in design and provide efficiency and economy with two simple components - an outdoor unit and one or more stylish, low profile, indoor units. All built with Trane's legendary reliability and innovative thinking. Introducing the new TRANE Split System Family MXD High Efficiency Ceiling Concealed Type Indoor Unit Quiet Operation Specially designed air flow structure efficiently reduces operation noise to provide quiet comfort, as low as 9 db. Built-in Drain Pump Easily drain condensation from the unit with the built-in drain pump. Compact Design The compact construction and simple structure make the concealed model easy to install and maintain. Fresh Air Supply Designed to exchange fresh air from outside to indoors improving the air quality of the room.

Contents Model Nomenclature General Data -6 Unit Dimensions 7 Mechanical Specifications 8 INDOOR UNIT MODEL NOMENCLATURE 1 M X X 5-6 7-8 9 10 11 1 1 1 65 1 A 1 0 N 0 B Refrigerant Service Digit = R-10A A, B, C, etc. = Service Digit Sequence 15 A Unit Type M = Indoor Unit U = Pro Series Minor Design Sequence A, B, C, etc. = Minor Design Sequence Functional Type X = Heat Pump Inverter Y = Cooling Only Inverter Reserved for Future Use 0 = Not Currently Used Configuration Indoor Unit Regional Markets Served (1:1 Systems) W = High Wall Unit N = North America Market D = Ceiling Concealed Unit C = Cassette Unit Reserved for Future Use F = Floor Console Unit 0 = Not Currently Used X = Convertible (Floor/Ceiling) Mount L = Cassette Panel Cover Electric Power Supply Characteristics 1 = 08-0/60/1 Efficiency Tier L = 115/60/1 16 = 16 SEER 65 = 16 SEER Major Develompent Sequence 85 = 18 SEER A, B, C, etc. = Major Development Sequence 0 = up to 0 SEER Pro Series = up to SEER 7 = up to 7 SEER Nominal Capacity (Btu/h x 1,000) 09 = 9,000 Btu/h 0 = 0,000 Btu/h 1 = 1,000 Btu/h 6 = 6,000 Btu/h 18 = 18,000 Btu/h =,000 Btu/h 1 = 1,000 Btu/h 8 = 8,000 Btu/h =,000 Btu/h

MODEL - Duct Type General Data MXD8509A10N0 MXD851A10N0 RATED Volts/PH Frequency (Hz) Total Cooling Capacity (Btu/h) Total Heating Capacity (Btu/h) Air Flow Volume (CFM) (H/M/L) Max. Static Pressure (In.HO) Sound Power Level db(a) (H/M/L) Sound PRESSURE Level db(a) (H/M/L) 1 Dehumidifying Volume (pint/h) 08 / 0 / 1 8500 9500 65 / 177 / 17 0.0 7 / / 9 7 / / 19 1.69 08 / 0 / 1 11900 1100 / 6 / 177 0.0 9 / 5 / 0 9 / 5 / 0.96 PCB Fuse Current (A) Fan Quantity Fan Type Motor Full Load Amp (FLA) Fan Motor Drive Type Fan Motor Speed (RPM) (H/M/L).15 0.8 970 / 760 / 60.15 0.1 960 / 80 / 700 Evaporator Face Area (ft) Evaporator Number of Rows Evaporator Fin Type Evaporator Fin Coating Air Filter Size (L x W/No.) Gas Pipe (to indoor unit) (inch) Liquid Pipe (inch) Connection Method Drain Connection (inner diameter)(inch) 1.18.68 x 7.77 / 1 /8 1/ Φ1.0⅛ 1.18.68 x 7.77 / 1 /8 1/ 1.0⅛ Dimension (Uncrated) (W x D x H) Dimension (Crated) (L x W x H) Net Weight (lbs) Gross Weight (lbs) 7.56 x.1 x 7.87 5.0 x 9.1 x 11. 8.5 59.5 7.56 x.1 x 7.87 5.0 x 9.1 x 11. 50.7 6.9 1 Sound PRESSURE Level @. ft. db(a)

MODEL - Duct Type General Data MXD8518A10N0 MXD851A10N0 RATED Volts/PH Frequency (Hz) Total Cooling Capacity (Btu/h) Total Heating Capacity (Btu/h) Air Flow Volume (CFM) (H/M/L) Max. Static Pressure (In.HO) Sound Power Level db(a) (H/M/L) Sound PRESSURE Level db(a) (H/M/L) 1 Dehumidifying Volume (pint/h) 08 / 0 / 1 1500 18700 1 / 5 / 9 0.0 51 / 6 / 0 1 / 6 / 0.80 08 / 0 / 1 000 600 589 / / 0.06 5 / 7 / / 7 /. PCB Fuse Current (A) Fan Quantity Fan Type Motor Full Load Amp (FLA) Fan Motor Drive Type Fan Motor Speed (RPM) (H/M/L).15 0.1 90 / 780 / 70.15 0.50 985 / 800 / 680 Evaporator Face Area (ft) Evaporator Number of Rows Evaporator Fin Type Evaporator Fin Coating Air Filter Size (L x W/No.) Gas Pipe (to indoor unit) (inch) Liquid Pipe (inch) Connection Method Drain Connection (inner diameter)(inch) 1.61 1.57 x 7.60 / 1 1/ 1/ Φ1.0⅛.05 9.7 x 7.7 / 1 5/8 /8 1.0⅛ Dimension (Uncrated) (W x D x H) Dimension (Crated) (L x W x H) Net Weight (lbs) Gross Weight (lbs) 5. x.1 x 7.87.09 x 9.1 x 11. 59.5 79..1 x.1 x 7.87 51.97 x 9.1 x 11. 68. 90. 1 Sound PRESSURE Level @. ft. db(a) 5

MODEL - Duct Type RATED Volts/PH Frequency (Hz) Total Cooling Capacity (Btu/h) Total Heating Capacity (Btu/h) Air Flow Volume (CFM) (H/M/L) Max. Static Pressure (In.HO) Sound Power Level db(a) (H/M/L) Sound PRESSURE Level db(a) (H/M/L) 1 Dehumidifying Volume (pint/h) PCB Fuse Current (A) Fan Quantity Fan Type Motor Full Load Amp (FLA) Fan Motor Drive Type Fan Motor Speed (RPM) (H/M/L) Evaporator Face Area (ft) Evaporator Number of Rows Evaporator Fin Type Evaporator Fin Coating Air Filter Size (L x W/No.) Gas Pipe (to indoor unit) (inch) Liquid Pipe (inch) Connection Method Drain Connection (inner diameter)(inch) Dimension (Uncrated) (W x D x H) Dimension (Crated) (L x W x H) Net Weight (lbs) Gross Weight (lbs) General Data MXD85A10N0 08 / 0 / 1 800 700 589 / / 0.06 5 / 7 / / 7 / 5.8.15 0.50 985 / 800 / 680.05 9.7 x 7.7 / 1 5/8 /8 Φ1.0⅛.1 x.1 x 7.87 51.97 x 9.1 x 11. 68. 90. 1 Sound PRESSURE Level @. ft. db(a) 6

Unit Dimensions G I Backward Return Air Electric Box Liquid Pipe Gas Pipe H E A D Drain Pipe Downward Return Air F J B C Unit Dimensions - In. (mm) MODEL A B C D E F G H I J MXD8509A 9. MXD851A (7) MXD8518A 7.1 (9) 19. (91) 19. (91) 6.1 (66).9 (86). (60). (80) 7.6 (700) 5. (900). (615). (615) 0.8 (78) 8.7 (98) 6.1 (156) 6.1 (156) 7.9 (00) 7.9 (00) 5.0 (65) 5.0 (65) MXD851A 5.0 MXD85A (11) 19. (91) 1.8 (106) 0.1 (100). (1100). (615) 6.5 (118) 6.1 (156) 7.9 (00) 5.0 (65) NOTES: Be sure to place a inspection opening at the position indicated in the following diagram for maintenance of the equipment. Air inlet.6 (600mm) inspection opening 5.9 (150 mm).6 (600mm) Air outlet 7

Ceiling Concealed Type Indoor Unit Mechanical Specifications General The ceiling concealed type air handler shall be completely factory assembled including coil, condensate drain pan, built-in condensate drain pump, fan motor and electric controls to be used with a wired remote controller. Unit shall be matched with a Trane outdoor unit, rated and tested in accordance with AHRI standard. Unit shall be ETL listed. Unit Casing Casing shall be provided with drain hose to facilitate piping and electrical connection on the right and left of the unit. An electrical service cover shall be provided to permit easy access to the electrical terminal strip. Discharge Airflow and Distribution System The unit is shipped configured for connection to rectangular grilles or registers. Alternate styles may be used with a field supplied transition. Supply and return connections should be no longer than. feet total. This system is designed for customers that want a concealed system. It is not intended for air handler use to multiple rooms. The system may be configured for either backward return air (default set-up) or by changing the flange and return cover plate the unit can be configured for downward return air. Controls Units shall have the capability to be controlled with the supplied wired control unit. The optional wireless remote may be used to operate the wall mounted control. Remote Controller The unit may have an optional wireless infrared remote controller with easy reading digital display panel to start, stop and regulate the supplied wired control from a distance. The wireless controller is available for all units. (Sold separately) Trane 600 Troup Highway Tyler, TX 75707-9010 01/16 The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 8