REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

Similar documents
LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

CHAPTER 7 DEVELOPMENT STANDARDS

Lighting Depth Part 1: Exterior Space

2005 Title 24 Outdoor Lighting Regulations Overview. 77 slides

2. Measurements are to be made at ground level, with the light-sensor portion of the meter lying flat on the ground, pointing upward.

Lighting Design Criteria: Codes and Standards

SECTION LIGHTING REGULATIONS

BIRMINGHAM TOWNSHIP CHESTER COUNTY, PENNSYLVANIA Subdivision and Land Development Ordinance No Dated 02/18/03

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Article 14. LIGHTING REGULATIONS

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Exterior Façade Lighting Design

Landscape and Streetscape Design 2.5

SECTION INTERIOR LIGHTING

Uniformity Avg. : Min. Maintained Use/Task

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Lobby Lighting Design

Related Sections: TBD. Effective Date: January 1, 2016

UPPER DUBLIN TOWNSHIP MONTGOMERY COUNTY, PA STAND-ALONE LIGHTING ORDINANCE

9. LIGHTING. 9.1 General Scope. This section shall apply to the following: Exceptions:

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

Lighting Existing Conditions and Design Criteria Report

ARTICLE XVI LIGHTING, NOISE AND ODOR/ODOROUS MATTER Shelby County Zoning Regulations 2013

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

Cosmetology Lab Redesign

Technical Report One

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

CHAPTER 32 EXTERIOR LIGHTING

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

SUBDIVISION & LAND DEVELOPMENT ORDINANCE

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

ARTICLE 10 EXTERIOR LIGHTING

Monterey Downtown Lighting Strategy

Duke Tower Main Entrance Lobby Overview

Design Guidelines for Exterior Lighting

1.1.0 Exterior Facade

Lobby Lighting Redesign

Induction Lamp Systems for Pedestrian, Low Level Pole and Lantern Lighting

SECTION EXTERIOR LIGHTING

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr.

Technical Report #1 Existing Lighting Conditions and Design Criteria

1.0 Introduction to Lighting Depth. 1.1 Hotel Tower Facace and Porte Cochere

Sidewalks Street Lights

Lighting Existing Conditions and Design Criteria Report

ARTICLE 31 EXTERIOR LIGHTING

NORTH COVENTRY TOWNSHIP SUBDIVISION & LAND DEVELOPMENT ORDINANCE LIGHTING

Draft Dark Sky Ordinance. This chapter shall be known as the Malibu Dark Sky Ordinance.

InvestSmart Business Energy Upgrades Lighting Equipment Catalog 01/01/2018

University of California Santa Barbara. Student Resource Building

from Warwick Township, Chester County, Zoning Ordinance, Amended April 7, 2008

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Lighting. Basis of Design

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

Eligible Prescriptive Measures List:

Public Hearing, July 12, 2018

8.6 EXTERIOR LIGHTING

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

Business Customer Information. Account Number (9 digits) Account Holder Name Phone (As shown on your utility bill) Service Street Address

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

and Pedestrian Lighting Master Plan San Jose Downtown Street The Redevelopment Agency of the City of San Jose Auerbach Glasow

Tomorrow, at the speed of light. Long-lasting, energy-saving LED retrofit lamps

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

Jennifer Mers. Rio Hondo Library and Learning Resource Center. Executive Summary. General Building. Lighting/Electrical Option

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA

Arlington. Full Cutoff. Utility Series

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

Fast. Precise. Versatile. UL Lighting Sciences

Oregon Non-Residential Building Energy Code

Outdoor Lighting for Julian Dark Sky Network, 2/10/18. Paul Ericson, PE San Diego IDA Board Member / Design Principal, Stantec

Union Township Berks County Outdoor Lighting 08/18/03 ORDINANCE NO

High Mast Series HMAO HMSC

Full Cutoff. Utility Series

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

S A N TA M O N I C C I T Y S E R V I C E S B U I L D I N G E X T E R I O R L I G H T I N G

in the IESNA Lighting Handbook and applicable Recommended Practices, except as otherwise required by the Board of Supervisors. 2.

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

LED Retrofit Lighting Rebate 2017 Rebate Application

SECTION LIGHTING

Bdl60u Fluorescent Emergency Ballast

Eric Anderson. Technical Report 1. Existing Lighting Conditions

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number.

Section 7.02 Lighting Standards

Applications. Standard Materials

Lighting Proposal Memo. Lighting Proposal. Angela Nudy Lighting/Electrical Dr. Mistrick Lighting Proposal Memo 1

C HAPTER 7: S TREETS, P ARKING & L IGHTING

SECTION INTERIOR LIGHTING

New LED Product Offerings

Lighting Guidelines. Planning Services Department Corporation of the Municipality of Clarington

ARTICLE 22, DIVISION 10 LIGHTING

Lindsey Beane. Executive Summary

Café DUSON- Overview

2.0 Lighting Depth Introduction

CHAPTER 11 HC HIGHWAY COMMERCIAL DISTRICT

Transcription:

Revision Date Section REVISIONS Summary of Change 6/1/12 All Replaced entire document with new revision REV 6/12 1 of 5

UNIVERSITY CONTACT: EXTERIOR LIGHTING Electrical Services, Maintenance & Operations (302) 831-2621 Electrical Engineer, Maintenance & Operations (302) 831-4907 Facilities Planning & Construction (302) 831-1744 DESIGN REQUIREMENTS ILLUMINATION LEVELS: Design illumination levels for different activities and spaces shall correspond to those listed below, LIGHTING LEVEL REQUIREMENTS. These levels are based on the Illuminance Standards found in the 9 th Edition of the IESNA Lighting Handbook and IESNA G-1-03 Guideline for Security Lighting for People, Property, and Public Spaces. The designer shall confirm the levels given in the edition of the IESNA Lighting Handbook relevant to the project; any subsequent criteria shall supersede the levels indicated below. For activities not covered by the University standards below, refer to IES recommendations. SECURITY LIGHTING LEVEL REQUIREMENTS From IESNA G-1-03 Guideline for Security Lighting for People, Property, and Public Spaces LOCATION AVG. MAINTAINED AVG. MAINTAINED VERTICAL 5 FT ABOVE GRADE AVG-TO-MIN UNIFORMITY RATIO Building Façade - 0.5-2 6:1 University Sidewalk 1 0.25 4:1 Facial ID - 0.5-0.8 4:1 Open Parking Lot 3 0.75 4:1 Parking Garage 6 0.5-0.8 4:1 Gathering Point in Parking Garage (Stairs, Elevators, etc.) 10* -- 4:1 *Measured within a 30 ft radius from the center of the gathering point. LOCATION LIGHTING LEVEL REQUIREMENTS From IESNA Lighting Handbook Ninth Edition AVG. MAINTAINED AVG. MAINTAINED VERTICAL 5 FT ABOVE GRADE AVG-TO-MIN UNIFORMITY RATIO Building Entrance 5 3 6:1 (Active) Building Entrance 3 3 4:1 (Inactive) Loading Dock 10 3 4:1 Exterior Egress Path 1 1 4:1 Note: While The IESNA Lighting Handbook addresses a variety of issues in determining recommended illuminance values, in G-1-03 it addresses security as the only issue, and deals with areas primarily away from buildings. Therefore values taken from G-1-03 shall be treated as minimum values. Values taken from the Lighting Handbook shall be treated as recommended values and closely targeted. REV 6/12 2 of 5

LIGHT POLLUTION REQUIREMENTS: Design illumination levels to not exceed the maximum initial illuminances for the different locations that correspond to those listed below, SITE LIGHTING TRESPASS LEVEL REQUIREMENTS. The designer shall confirm the levels given in the edition of the IESNA Lighting Handbook relevant to the project; any subsequent criteria shall supersede the levels indicated below. For activities not covered by the University standards below, refer to IES recommendations. SITE LIGHTING TRESPASS LEVEL REQUIREMENTS TO ADJACENT NON-UNIVERSITY PROPER LOCATION MAX INITIAL MAX INITIAL VERTICAL FROM GRADE TO HEIGHT OF HIGHEST FIXTURE POLE Site Boundary 0.20 0.20 15 ft beyond site boundary 0.01 - Note 1: For site boundaries that abut public right-of-way, light trespass requirements may be met relative to the curb line instead of the site boundary. Note 2: Illuminance generated from a single luminaire placed at the intersection of a private vehicular driveway and public roadway accessing the site is allowed to use the centerline of the public roadway as the site boundary for a length of 2 times the driveway width centered at the centerline of the driveway. The design must show that no more than five percent (5%) of the total initial designed fixture lumens (sum total of all fixtures on site) are emitted upward, at an angle of 90 degrees or higher from nadir. The design must also show that for interior lighting, the input power of all nonemergency interior luminaires with a direct line of sight to any openings in the envelope (translucent or transparent) be reduced (by automatic device) by at least fifty percent (50%) between 11 P.M. and 5 A.M. After-hours overrides may be provided by a manual or occupant-sensing device provided the override lasts no more than 30 minutes. SECURITY LIGHTING LEVEL REQUIREMENTS take precedence over all other lighting requirements presented in this section. LIGHTING POWER DENSITIES: Adjusted power densities for lighting as calculated in ASHRAE 90.1 compliance procedures shall not exceed the ranges outlined below for the different building spaces, in the space-by-space method. These levels indicated below are based on the 2007 edition of ASHRAE 90.1. The designer shall confirm the levels given in the edition of ASHRAE 90.1 that are relevant to the project; any subsequent criteria shall supersede the levels below. For spaces not indicated below refer to the edition of ASHRAE 90.1 that is relevant to the project. Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) LIGHTING POWER DENSITY From ASHRAE 90.1 2007 Applications Lighting Power Density Uncovered Parking Areas -Parking Lots and drives 0.15 W/ft 2 Building Grounds -Walkways less than 10 ft wide 1.0 W/linear foot -Walkways 10 ft wide or greater -Plaza areas -Special feature areas 0.2 W/ft 2 -Stairways 1.0 W/ft 2 REV 6/12 3 of 5

Non- Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the Tradable Surfaces section of this table.) Building Entrances and Exits -Main entries 30 W/linear foot -Other doors 20 W/linear foot Canopies and Overhangs -Canopies (Free standing and attached and overhangs) 1.25 W/ft 2 -Building façades 0.2 W/ft 2 for each illuminated wall or surface or 5.0W/linear foot for each illuminated wall or surface -Automated teller machines 270 W per location plus 90 W per additional ATM per location LIGHTING FIXTURES: Site lighting fixtures shall be full-cutoff (recommended) or semi-cutoff luminaires, as defined by IESNA. Overall site lighting design shall produce less than 5% uplight, as defined in LIGHT POLLUTION REQUIREMENTS above. Fixtures shall be easy to clean, relamp, replace ballast(s) and shall have a low dirt accumulation rate. Site lighting shall use metal halide light sources with multi-tap fused ballast and vandal resistant hardware. Decorative building façade lighting shall also be metal halide sources. Where building mounted fixtures are intended to be used for emergency egress lighting, fluorescent fixtures are acceptable. Ground accessible exterior lighting shall be completely vandal-proof in construction. Use vandal resistant hardware at less than 10 above finished grade. There shall be no in-ground, subterranean, or recessed in wall or step lighting installed. Bollard type lights are not to be used. Any deviations from these exclusions shall be brought to the attention of the University for their review and approval early on during the design phase of a project. Use University Proprietary, Pemco, post fixtures only for projects located on the Green, unless otherwise approved. DO NOT leave existing lighting circuits inoperable over night. DO NOT Install exterior lighting where it will impede snow removal efforts. SECURITY BLUE LIGHT FIXTURES: Blue Lights for emergency phones (No Deviations), reference CSI Section 16700 for additional information on the blue lights and emergency phones. -Killark VFC-100 fixture body -Killark VBG-100 globe blue -Killark VAG-100 fixture guard -Killark V series boxes and adaptor plates as needed for mounting Phillips SLS 15 Earth Light REV 6/12 4 of 5

CONTROLS: All exterior lighting fixtures shall be controlled automatically by photocell and astronomical time clock or connected to local building wide lighting control system. LAMPS: -Exterior time-clocked controlled lighting shall be controlled by Tork Series DZS (maintained Circuits) or Series DZM (latching circuits). FLUORESCENT LAMPS A. Low-Mercury Lamps: Comply with EPA's toxicity characteristic leaching procedure test; shall yield less than 0.2 mg of mercury per liter when tested according to NEMA LL 1. B. Compact Fluorescent Lamps: 4-Pin, low mercury, CRI 80 (minimum), color temperature 3500 K, average rated life of 10,000 hours at 3 hours operation per start, and amalgam type lamps suitable for cold weather, unless otherwise indicated. HID LAMPS 1. 13 W: T4, double or triple tube, rated 900 initial lumens (minimum). 2. 18 W: T4, double or triple tube, rated 1200 initial lumens (minimum). 3. 26 W: T4, double or triple tube, rated 1800 initial lumens (minimum). 4. 32 W: T4, triple tube, rated 2400 initial lumens (minimum). 5. 42 W: T4, triple tube, rated 3200 initial lumens (minimum). 6. 55 W: T4, triple tube, rated 4300 initial lumens (minimum). A. Metal-Halide Lamps: ANSI C78.1372, with a minimum CRI 65, and color temperature 4000 K. B. Pulse-Start, Metal-Halide Lamps: Minimum CRI 65, and color temperature 4000 K. C. Ceramic, Pulse-Start, Metal-Halide Lamps: Minimum CRI 80, and color temperature 4000 K. UNIVERSITY APPROVED LAMP MANUFACTURERS: -Philips -Osram-Sylvania -GE REV 6/12 5 of 5