UK Product Guide. Fire Doors.

Similar documents
AUTOMATIC DOOR RANGE COMFORT FOR CONNECTED PEOPLE

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

All by design. ASSA ABLOY Door Controls

IDD 033C - Fire door sets

The global leader in door opening solutions

Notice. Approval number: Z Scope of validity By: 08 January 2013 to: 01 November 2017

Advanced Fire Rated Ductwork Solutions

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

WDC SERVICE SOLUTIONS LTD

High Security Locking. Product Catalogue

YOUR GUIDE TO UNDERSTANDING CPR

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

Schueco Fire and Smoke Protection Systems

Open to Possibilities.

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

Steel Door Series S4. Certified Protection against Forced Entry, Fire, Ballistic and Blast Attacks. Protecting Lives and Property. Worldwide.

SECURE & BEAUTIFUL

Product Guide. The highest possible standards. The best possible solutions. Manufactured in the UK. Cert No 5893 ISO 9001

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

A new standard of burglar resistance EN 1627:2011 took force in Europe more security for your premises

BLAST AND PRESSURE-RESISTANT PRODUCTS. A wide range of blast- and pressure-resistant door and fixed window systems. AN ISO 9001 CERTIFIED COMPANY

Regulatory Reform (Fire Safety) Order 2005

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

F O C U S D O O R C L O S E R S

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

For more information on Smart Architectural Aluminium visit The art of creative living. alitherm windows & doors

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

FGS 35 SLIMLINE SLIDING DOOR SYSTEM

The art of creative living. duotherm windows & doors

Protect human life against hazards at refineries and other sensitive. Complete cabin protected against blast, gas, fire and smoke

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

Envision Enhance Endure. Interior Aluminum Framing

DOOR SETS. Versatile with a range of options, they can be tailored to suit your needs.

Guide to interpreting Markings for Single Axis Fire Doors Hinges

TILT AND SLIDE WINDOW

Maintenance. Why Maintain Fire Doors? Regulations

Contents EN :2006+A2:2016 (E)

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

SCREEN VISION SV 3% KOOLBLACK TM

Your perfect PVC-U partner WINDOWS DOORS. spectus n. look, appearance, aspect

ES 200. Sliding door operator

DC200 Rack and pinion door closer with link arm

FULLY INSULATED COMPOSITE STEEL FIRE DOORS

Saving lives with coatings

Opening Doors to Healthcare. Specification Guide. The global leader in door opening solutions. ASSA ABLOY Security Solutions

FIRE DOORS AND FRAMES. Model: SF/SD Single Door. Model: SF/DD Double Door

CE Compliance. Silva Management. September 18th, 2014 David Norris. C Eng. FI Mech E.

Smoke Vents. Certified to CE EN Roof Access Systems

PANIC EXIT HARDWARE DX-500 Serie

Allstyle. Complete Aluminium Glazing System

can be implemented, e. g. as counter closures and are the only fire protection roller doors authorized for higher position of installation.

Your Key to achieving C.E Marking Compliance

SCREEN NATURE. SCREEN NATURE SCREEN NATURE INTELLIGENT FABRICS FOR SOLAR PROTECTION INTERNAL APPLICATION COLLECTION

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

EM Hold-open magnets

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ABLOY DOOR CLOSERS Excatly the right choice

BRISTOL: A History & Future.

Regulatory Reform (Fire Safety) Order 2005

Made-to-order timber windows and doors.

DAVITS INFORMATION & CERTIFICATION

TILT AND TURN WINDOW

Fire Protection. Intumescent fire and smoke seals for door assemblies

Transaction Windows and Security Entrances

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

WM S TIMBER SLIDING SASH WINDOWS HAVE BEEN DESIGNED TO INCLUDE A TRADITIONAL LOOK, MODERN-DAY TECHNOLOGY, AS WELL AS ENERGY EFFICIENCY.

For more information on Abloy UK visit EXIT HARDWARE

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

Type 5 Certifications:

Hold-open magnets DORMA


Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

Standards in Security Shutters & Fire Shutters (UK & USA)

Fire Protection. Fire-resistant Glass Range. Pilkington Pyrostop. Pilkington Pyrodur

TOPAZE CONTEMPORARY WINDOW. Architect: Opera Architecte Photography: J.C. Ballot

General test 74 Thermal properties 75 Fire windows 75 Sound reduction 76 Safety 76 CWCT accreditation 77 Resistance to forced entry (SBD) 78

FAÇADE FIRE TESTS Towards a new European standard method

EXTERNAL SCREEN CLASSIC

SCREEN THERMIC. SCREEN THERMIC S2 1 % -3 % -5 % INTELLIGENT FABRICS FOR SOLAR PROTECTION INTERNAL APPLICATION

CERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS

Easy-action Door Closer DORMA TS83

ABLOY FIRE DOOR CLOSING SYSTEMS

Improving electrical cable safety in Europe

Guidance Note No 19/1. CE Marking windows and doorsets

About Smart. Expand your horizons with our high-quality sliding and slide-folding doors

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

Mechanically operated locks and locking plates

Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

5.1.2 Doors used by Patients Doors to rooms that are likely to be used by patients without staff assistance should be single or double swing type.

Construction Products Directive

Timber Doorsets For Every Application. ASSA ABLOY, the global leader in door opening solutions

White Paper. Effective and Energy Efficient Access Control in Commercial Buildings. The global leader in door opening solutions

High-Speed Roll Doors An intelligent entrance solution for every location. ASSA ABLOY Entrance Systems

WINDOWS PATIO DOORS BIFOLDING DOORS ENTRANCE DOORS ROOFLIGHTS CONSERVATORIES SCREENS ALLSTYLE COMPLETE ALUMINIUM GLAZING SYSTEM

air handling units AT THE LEADING EDGE OF AIR FLOW

L411:P43 D11:X421. CI/SfB. (31 5) Xh4

Transcription:

UK Product Guide. Fire Doors. We are committed to compliance at all times with statutory and mandatory requirements of UK Building Standards and Harmonized Product Norms Insulated Fire Doors Teckentrup Fire Doors M ade in Germ any Perfect solutions for all structural conditions

2 : Company Teckentrup GmbH & Co. KG, Verl-Sürenheide The Company. A safe partner. The objective of Teckentrup UK Limited is straightforward; to lead the market with products that are compliant to all current standards, offer a best practice choice to the construction industry and, in doing so, become a safe partner. Scale Teckentrup UK Limited is part of the Teckentrup family of companies. Incorporated over 80 years ago, Teckentrup is a family business and one of the largest steel door producers in Europe, employing 950 people and operating from 1.1m sqft of manufacturing space on two sites in Germany. Investment Teckentrup maintains a dynamic approach to product improvement and new developments through continual annual investment. In addition, every ten years, Teckentrup invests 40% of annual revenues in fixed asset expansion. Performance Standards Systematic testing of products to current and new performance standards is a cornerstone of Teckentrup s commitment to compliance at all times with the statutory and mandatory requirements of relevant UK Building Standards and Harmonized European Product Standards and Norms. Products are CE marked in accordance with current CPR legislation. Responsibility Teckentrup takes very seriously its responsibility to ensure products are tested to the performance standards claimed and are suited to the performance and functional requirements specified. These responsibilities are of prime Teckentrup UK Limited, Warrington Factory Großzöberitz importance when dealing with life safety products, such as fire rated doors, doors to escape routes and emergency exits. Teckentrup considers upholding standards as a powerful tool to demonstrate the capability and strength of its business. Its processes and products are certified and tested to the following: Business Processes ISO 14025 & EN15804 Environmental Product Declaration DIN EN ISO 9001 Quality management DIN EN ISO 14001 Environmental management DIN EN ISO 50001 Energy management Product Performance (Sub-Norms) EN1634-1 DIN4102 DIN18095 EN1627-30 EN1062 Exova STS202 Factory Verl Fire resistance Fire resistance Smoke resistance Physical attack resistance, static and dynamic loading Bullet resistance Physical attack resistance DIN EN20140 & ISO140-3 Sound attenuation EN12207 Air permeability EN12208 Water resistance EN12210 Wind resistance ISO10077-1 & ISO12567-1 Thermal insulation

3 : Key Performance Criteria Life Safety Performance. Setting a new level. Teckentrup s core expertise is the design and manufacture of fire doors. It has left its mark in on the development of structural fire protection in Germany for decades. Teckentrup was the first company to introduce a fire rated sliding door with approval to DIN4102 fire test standard. It seeks at all times to provide best practice choices. Best practice choices? Teckentrup s approach is best exemplified by its insulated fire doors and the opportunity they provide for architects to specify a, commercially competitive, integrity and insulation performance level. The UK & Ireland are the only major European markets where it is NOT mandatory to specify steel personnel doors with both insulation and integrity fire ratings. In a fire situation an un-insulated, hollow metal door will contain a fire but offer little resistance to the passage of thermally radiated heat. Levels of up to 33.5 kw/m 2 after 30 minutes at 0.5M from the unexposed surface are typically recorded on test, risking harm to people queuing in high traffic, escape corridors. These levels also risk becoming an ignition source for close proximity inflammable materials. The Teckentrup T60-FSA Fire Resistant steel door is tested to EN1634-1. It provides up to 120 minutes integrity and up to 60 minutes insulation, increasing the safety of any people in proximity to the door in a fire situation. Thermal Radiation Effects from 0.5m Results from the unexposed side of a steel door in a BS EN1634-1 fire test Thermal Radiation kw/m 2

4 : Range Excellence. Insulated fire doors. Teckentrup 62mm insulated steel fire doors are heavy duty products suitable for Front of House, Back of House and high human traffic locations. They are constructed from galvanized steel, with insulated cores and supplied with captive seals in PPC finish, either in white primer or any RAL colour. Insulated Fire Door Thin Rebate Stainless Option Insulated Fire Door Thick Rebate Insulated Fire Doors T90 DF-1/2 FSA Stainless Option Insulated Fire Doors T60-1/2 FSA A thick rebate fire door available up to 3000x3500mm galvanized steel door also available with the option of a stainless steel finish. It has been tested to: EN1634-1 achieving 90 minutes integrity and 90 minutes insulation DIN4102 (assessed to BS476: Part 22) DIN18095 for resistance to passage of smoke Acoustic test standard DIN EN20140 and evaluated to ISO717-1 achieving Rw40dB A thin rebate insulated product priced competitively with UK standard un-insulated doors. Available in a stainless steel construction and with vision panel options. It has been tested to: EN1634-1 achieving 120 minutes fire integrity and 60 minutes fire insulation DIN18095 for resistance to the passage of smoke DIN EN20140 and evaluated to ISO717-1 achieving Rw33dB acoustic performance EN1627 achieving RC2, RC3 & RC4 security ratings EN1191 for repeated opening and closing achieving a C5 rating - 200,000 cycles

5 : Range Versatility. Performance fire doors. Fire D oor Flush Edg e Stainless Option Insulated Fire Door Flush Edg e Insulated Fire Door Flush Edg e Un-insulated Fire Doors HC-BS-1/2 Glass Fire Doors T30-FSA GL-1/2 Sliding Insulated Fire Doors 72 E-1/2 30/90 FSA Teckentrup hollow metal, HC-BS fire and GP general purpose, un-insulated doors are characterized by their slim, flush appearance and conventional butt hinges. The non-rebated door leaf sits flush with the face of the frame that is mitred at the head to jamb interface. These products are available in all conventional configurations, with a large range of ancillary items and options, including stainless steel constructions. HC-BS doors are fire rated in single and double swing, double egress and latch-less versions Fire resistant and smoke proof in accordance with BS EN 1634-1 Single and double leaf, latch-less, double swing and double egress configurations available Flush edge door Frame flush with the wall mitred frame corners Concealed screw fixing Flexible design concepts Easy and quick installation without welding The new door T30-FSA Teckentrup GL fire rated glass door has been tested to conform with EN 1634-1 (DIN 4102). The frameless construction enables a maximum level of transparency that meets the current requirements for modern and aesthetically pleasing fire protection. Design-oriented fittings round off the high-quality look. The door is available in single and double leaf designs. Frameless fire protection door Maximum transparency High-quality elegance Fire-resistant Smoke-proof A sliding fire door available in single and two leaf configurations with T30 (30 minutes integrity and insulation) and T90 fire resistance performance. Optional extras: Glazing Electric operation Wicket doors Stainless steel constructions

6 : Selector Selector Door Type Leaf Thickness DIMENSIONS (mm) Leaf Sheet Thickness Max Opening Size FIRE EN1634-1 DIN4102 & BS476: Pt 22 mm mm mm Insulation Integrity Insulation Integrity CERTIFIRE Insulated Fire Doors T60-1/2 FSA 62 1/1.5 2500x2500 I60 E120 Insulated Fire Doors T90 DF-1/2 FSA 62 1/1.5 3000x3500 T90 T90 Hollow Metal Honeycomb Fire Doors HC-BS-1/2 45 1.5 2900x3000 E240 Fire Resistant Glass GL-1/2 27 N/A 2500x2500 T30 T30 Insulated Sliding Fire Doors 72 E-1/2 30/90 FSA 72 1.0 8500x6000 T30/T90 T30/T90 Frames, Hinges & Security Pins 32 2 30 1 43/54/62 73/84/92 1 1 43/54/62 20 10 48 10 48 10 48 Corner Frame Counter Frame Wrap-Around Frame

7 : Selector SMOKE DIN18095 SECURITY LOADING ACOUSTIC CPR CONFIGURATION OPTIONS RC2 EN1627 RC3 RC4 EN1628/9 ISO717-1 db Thermal Insulation ISO12567-1 Wm 2 Kº Thermal Insulation ISO10077-1 Wm 2 Kº Cycles / Usage EN1191 Latchless Double Swing & Double Egress Stainless Steel Glazing Electric Opening * 33 1.8 1.3 C5 41 1.8 1.3 BIM 35 34 * Single Leaf Only 2 75 KO Hinge 3 10 48 1 43/54/62 120/160 Corner frames, counter frames and wrap-around frames achieve a wider clear opening than conventional block frame designs - the door leaf is wider as a consequence for any given opening size. Block Frame Steel Security Pins 3-D Adjustable Hinge

Safely & Responsibly Built. The responsible use of natural resources is important to us. We support you in your environmentallycompatible and sustainable construction projects. This is why all of our products are certified in accordance with the Environmental Product Declaration (EPD). A seal of quality which supplies all information on the life cycle and ecological assessment for the current building certification systems. DGNB BNB LEED BREEAM Deutsche Gesellschaft für Nachhaltiges Bauen e. V. German Sustainable Building Council Bewertungssystem Nachhaltiges Bauen Leadership in Energy and Environmental Design Building Research Establishment Environmental Assessment Methodology Also from Teckentrup Security Doors Acoustic Doors External Enveloping Doors Teckentrup (UK) Limited, Unit 8-9, Gemini Trade Park, Europa Boulevard, Warrington WA5 7YF Tel: 01925 924 050 Fax: 0870 131 4843 Email: sales@teckentrup.co.uk www.teckentrup.co.uk Subject to technical changes. 01/06/15 (GB) All illustrations in this brochure are solely intended to highlight individual product features and may therefore not necessarily be identical with the standard product version. W E O P E N T H E D O O R S F O R P R O G R E S S