NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

Similar documents
October Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance

Energy Conservation and Equipment Reliability With Ultrasound

SONOCHEK The ultrasonic testing device

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

Product Catalog. Ultrasound Leak Detection and Condition Based Monitoring

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

INFRARED WINDOW SERIES

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

Steam Trap Inspection Methods And Steam Cost Analysis

User Manual for ULTRASCAN High Pressure Leak and Corona Discharge Detector

Tru Pointe Ultra Ultrasonic Leak Detector

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

ULD-40. Ultrasonic Leakage Detection, Accoustic emission & Corona detection

CONTINUOUS MONITORING IS ON THE RISE:

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

infrared inspections efficient solutions. focused results.

Monitoring of Electrical Equipment Failure Indicators and Alarming

Compliance without compromise Safety without sacrifice

Find Condenser Tube Leaks with Ultrasound

100 Year Anniversary Of Anne Of Green Gables Features MXRW Website! Maximum Awards Inc. (MXRW) $2.30

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

Regional Training. Seminar. » EasyPower Hands-On» Protective Device Coordination» Arc Flash Hazard Analysis. March 12-16, 2018 Austin, TX

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

IEEE Transformer Committee PC Distribution Transformer Monitoring - User

i-alert Monitoring Solution Sensor App Ai Platform

ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION STEAM TRAP INSPECTION VALVE INSPECTION TIGHTNESS TESTING DETECTION OF PARTIAL DISCHARGES

How to reduce exposure to arc flash hazards

DISTRIBUTION OPERATIONS AND MAINTENANCE

Risk Mitigation of Aging Electrical Infrastructure

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

Application Note. Technique description CPB measurements give early fault detection with minimal risk of false alarms

Electrical Preventive Maintenance (EPM) Program

CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843)

Property risk solutions

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

ULTRASCHALLPRÜFGERÄT ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION

Assignment 5: Fourier Analysis Assignment due 9 April 2012, 11:59 pm

Declaration of Conformity

NEW HV/LV TRANSFORMER SUBSTATION WITHIN A BUILDING INTENDED FOR OTHER NON ELECTRICAL USES WITH ADVANCED FUNCTIONALITIES

A Powerful Case for Infrared Windows

Development and Application of the Rail-type Inspection Robot used in Substation Rooms

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

PD alarm system brings peace of mind in Malta

Optical Techniques for Industrial Inspection

Cabinet Cooler Systems

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

Certification of Thermographers

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

The New Device Class for Preventive Maintenance

EEM 451 Industrial Control Systems Sensors and Actuators-II. Dept. of Electrical-Electronics Eng. Anadolu University, Turkey

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

IRT2 Dual Laser IR Thermometer - User Guide

E-16 Main Engine Remote Control System

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

Arc Flash Protection Training - NFPA 70e Electrical Safety

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

US Navy Leading the Way in Switchboard Protection

SEL Arc-Flash Solutions

Whisper. Ultrasonic Leak Detector

Part Number Structure ZA 016 L D CT

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

Effective Use of Statistical Models to Establish and Update Vibration Alarm

NFPA 70B and the Importance of Electrical Predictive Maintenance

Part Number Structure ZT 028 L D CT R 15

1 Introduction - The rating level. 3 Subjective or objective analysis? 2 Determination of the adjustment for annoying tones

LEARNING SPECIAL HAZARD DETECTION TYPES

What is Room EQ Wizard (aka REW)?

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

Electric Fire Pump Controller Inspection, Test & Maintenance Arc Flash Hazard White Paper

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

Multi-Technology Fault Identification

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

Flame Simulator User Manual. Publication Rev. A

SEL Arc-Flash Solutions

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

Product Tests Report

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Engineering Design & Testing Corp./EDT Engineers, P.C.

TECHNOLOGY GETS THE JUMP ON MOTHER NATURE.

INSTALLATION MANUAL. '»'"',' ','"* Self-contained Ceiling Mount Electronic Air Cleaner.

How to spot and address potential process problems using thermal imaging

F-Series Tower Drying

MAINE FUEL BOARD MASTER OR JOURNEYMAN OIL TECHNICIAN APPLICATION TO ADD AN AUTHORITY

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

EQUIVALENT INITIAL ELECTRICAL SAFETY ASSESSMENT

REVIEW ON CONDENSER AIR LEAK TEST

Transcription:

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In? Adrian Messer, Manager of US Operations UE Systems, Inc. Ph: 864-224-4517 Cell: 914-282-3504 Web: www.uesystems.com Email: adrianm@uesystems.com Abstract When it comes to establishing an electrical maintenance program for your facility, there are many resources at your disposal to which you could look. As for the tools that can be used to then inspect energized electrical equipment, an infrared camera is probably the first tool that comes to mind. Some of you may have even said an airborne ultrasound instrument. If you said ultrasound, you are among a growing number of maintenance and reliability professionals who have come to realize that airborne ultrasound is a viable tool that can effectively be used to inspect and diagnose conditions such as corona, tracking, arcing, and partial discharge in energized electrical equipment. The standards that maintenance and reliability professionals have access to for guidance when establishing procedures and best practices for inspecting and maintaining electrical equipment in facilities are the National Fire Protection Association (NFPA) 70B, and the Canadian version the Canadian Standards Association (CSA) Z463. Both of these documents have been established in order to create recommended practices for inspecting and maintaining electrical assets in order to prevent accidents and reduce downtime. NFPA 70B & CSA Z463 Discussion According to NFPA 70B standard for electrical maintenance, an Electrical Preventive Maintenance program is a managed program of inspecting, testing, analyzing, and servicing electrical systems and equipment with the purpose of maintaining safe operations and production by reducing or eliminating system interruptions, and equipment breakdowns. 1

When it comes to the inspection tools that NFPA 70B recommends for inspecting energized electrical equipment, the document only mentions ultrasound in two sections. The first mention is in section 11.21.3.3.2.2 when discussing partial discharge. The other mention is in section 15.1.2.2 which discusses corona in substations and switchgear. The Canadian equivalent to NFPA 70B, the CSA Z463, goes into more detail when discussing ultrasound technology. CSA 463 says in section 7.10.2 that ultrasound inspections use collectors that detect the high frequency produced by the emissions caused by electrical arcing, tracking, and corona. This section also goes on to mention the fact that the sound heard by the inspector can be recorded and then further analyzed in a spectrum analysis software for an accurate diagnosis of what was detected by the ultrasound instrument. As for airborne ultrasound, a technology that was once considered just a leak detector, users of the technology quickly began to realize that the instruments could be used for other applications, such as condition monitoring of rotating equipment and electrical inspection. To many, airborne ultrasound has become a necessity when inspecting energized electrical equipment. The primary driver of this application is safety. In most cases, airborne ultrasound inspection can be done without opening energized electrical cabinets. Performing an inspection without opening energized electrical equipment helps to reduce the risk the inspector faces from potential exposure to arc flash hazards. What is Ultrasound? Ultrasonic equipment detects airborne and structure-borne ultrasounds normally inaudible to the human ear and electronically transposes them into audible signals that a technician can hear through headphones and view on a display panel as a db level. On some instruments, incoming sound can also be viewed on a spectral analysis screen which shows either the FFT or Time Wave Form. With this information, a trained technician can interpret the bearing condition in order to determine what, if any, corrective action is needed, and the current data can be compared on the spot to the baseline data. Ultrasound technology has many advantages: It can be used in virtually any environment. Learning to use ultrasound technology is relatively easy. The technology is relatively inexpensive. Modern ultrasonic equipment makes it easy to track trends and store historical data 2

Ultrasonic technology has proven itself to be extremely reliable in predictive maintenance, saving thousands upon thousands of dollars and hours of lost productivity There are remote monitoring options for both mechanical and electrical applications Airborne and structure-borne ultrasound instruments are an extension of the user s sense of hearing. Similar in that vibration feels what you can t feel and infrared cameras see what you can t see, ultrasound hears what you can t hear. There are sounds taking place in a typical plant and manufacturing environment (machines running, production equipment running, etc.) that prevent us from hearing other sounds such as compressed air leaks, or electrical discharges like corona, tracking, or arcing. Ultrasound instruments listen for sounds that are not present in our normal audible range. Typically, the sounds outside normal human hearing are high frequency sounds. The high frequency sounds are detected by the instrument and translated through a process called heterodyning into an audible sound that is heard in the headset by the inspector. The unit of measurement for sound is a db level which is indicated on the display of the ultrasound instrument. The ultrasound inspection can be done by scanning any openings on the cabinet itself, such as vent opening, seals around doors, louvers, etc. Therefore, before any energized electrical cabinet is opened for maintenance or further inspection, a preinspection can be done with ultrasound to see if any anomaly is heard. If there is a condition like corona, tracking, or arcing inside of the electrical equipment, the ultrasound produced by those anomalies will be heard by the inspector via those openings. The source of the ultrasound produced is ionization. Electrical Inspection with Ultrasound Ultrasound can be used to inspect almost any energized electrical equipment. This equipment may include metal-clad switchgear, transformers, substations, relays, and motor control centers, along with many others. Ultrasound can be used to measure equipment voltages from the low end (110 volts) to well over 12000 volts (12kV). Traditionally, inspection of energized electrical equipment has been performed using noncontact infrared cameras. However, in recent years, ultrasound has been added to these inspections for various reasons. One of the main reasons has been for safety: An ultrasound inspection of electrical equipment can be done without the need to open the energized cabinet or enclosure. The hand-held ultrasound instrument is used to scan any openings on the cabinet. The high frequency sound produced by corona, tracking, and arcing from inside of the enclosure will exit through any of the openings. The inspector will hear the sound via the headset, and know that an anomaly is present. 3

The sound can then be recorded to determine if the condition is corona, tracking, arcing, or some type of mechanical looseness. Traditional ultrasound inspection of enclosed energized electrical equipment Corona refers to the ionization of air surrounding an electrical connection above 1000 volts. Corona, by nature, does not produce significant heat that would be detected by an infrared camera. However, it does produce high frequency sound that can be detected by the ultrasound instrument. If corona discharge continues to occur, it can lead to a more severe problem such as tracking or arcing. Byproducts of the ionization process are ozone, electromagnetic emissions, ultraviolet light, and nitric acid. The nitric acid is a corrosive and can deteriorate the insulators and connectors and lead to tracking and arcing. Corona activity advancing to the tracking stage on insulation board resting on 13kV bus. Notice the carbon deposits and light brown discoloration of the insulation board on the right. 4

When the sound file of corona is recorded, there are signature characteristics visible in the FFT and Time Wave Form (TWF) that will help to diagnose the condition. For corona, the discharge points only occur at the highest voltage point on the sine wave. This means that the amplitude peaks in the TWF are somewhat equally spaced as the discharges are only at the positive peak of the sine wave. The result will be well defined 60Hz or 50Hz harmonics. Example discharge points for corona FFT view of a recorded sound file of corona showing 60Hz harmonics For tracking (low current pathway to ground across an insulator) and arcing (electrical discharge to ground across an insulator) there are also certain characteristics to look for. With tracking, the discharge does not have to take place at the peak of the waveform. Instead, it can happen anywhere on the positive portion of the cycle. The spacing of the peaks in the TWF would be similar, but not uniform. As tracking becomes more severe, there are more discharge events and therefore more nonuniformly spaced narrow peaks. 5

Arcing has the most non-uniform look in the FFT and TWF. Only the bursts of the discharge can be heard and these will be seen as wide peaks in the TWF view. Arcing as seen in the Time Wave Form view Conclusion As for NFPA 70B, in all fairness, we are currently in the middle of a revision period for the standard. The next revision is scheduled to be released in 2016. I hope that the 2016 revision of NFPA 70B will add additional information regarding ultrasound, and how it can be used for electrical inspections. Both documents do go into great detail regarding the inspection and maintenance of any electrical asset in a facility. There are even recommended procedures discussed regarding asset criticality and establishing an electrical maintenance program. If you happened to be on the Technical Committee for NFPA 70B, I would welcome any comments and discussions regarding airborne ultrasound technology and its uses for inspecting energized electrical equipment. Speaking from experience, I can vouch for the fact that there is certainly an increased interest in airborne ultrasound for electrical inspection, not only from maintenance and reliability professionals in plants and facilities, but also from insurance companies that inspect a facility s electrical infrastructure. Sources: www.nfpa.org NFPA 70B www.csa.ca CSA Z463 6