BFFF HUY. Partial Frost-free Bottom Combi Nyíregyháza Factory

Similar documents
SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION

Service Quick Guide SQG_CL_15/01_EN

SERVICE MANUAL REFRIGERATION

SERVICE INSTRUCTION. DYNAMIC COOLING with 0 zone REFRIGERATION. Fridge/freezer with. Publication number

SERVICE MANUAL New Electronic Cold Platform 2005.

Fast Track Troubleshooting

Essentia Project Artica Platform No Frost 60 cm Appliances 2011

LCD on door ERF 2000 SERVICE INSTRUCTION COLD. Fridge/Freezer with electronic control. Publication number

EGE Manisa 70 cm BIR Carinaro 55 cm. Fabriano June Presenter Francesco Nieli

KitchenAid Food Stream Solutions Classic and Integrated Series

Owner's Manual TABLE OF CONTENTS

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

ENGLISH REMOTE CONTROL MANUAL

Service instruction Cold

Technicians Manual Single Compressor

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

4. ALIGNMENT AND ADJUSTMENTS

Model: Slimline-RF. 1 Slimline Series

B-764 FULL NF REFRIGERATOR CONTROL SPECIFICATIONS

BLOOD PLASMA Walk-in Freezers

Chromatographic Air circulated Refrigerator, two-door TC 603

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

FRIDGES AND FREEZERS COMBINED. EFC-2033 NF EX p. 108 EFC-2032 NF EX p. 109 EFC-2032 NF WH p. 109

Refrigerator KE T

TEMPERATURE & PRESSURE CONTROLS

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

Model: Slimline-B. Battery Series

User Guide ems25plus. Page 1. Normal operation. Product interface

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

New! Refrigerator FEATURES

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

Refrigerated air dryers

Turbo Freeze function

Benefit Cabinets. Performance. Efficiency

OPERATING AND INSTRUCTIONS MANUAL: B130/10/220H VACCINE REFRIGERATOR REV.1 (WITH TEMPERATURE HOLDOVER FUNCTION)

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Benefit Cabinets. Performance. Efficiency

Internet. Climate rating definitions. Customer service.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Laboratory refrigerators and freezers

Refrigerated Cabinets

TEKA - Teka is the only company that offers a complete solution for your kitchen

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

User Manual. Commercial Refrigerator And Freezer User s Manual

USER'S OPERATING INSTRUCTIONS

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

FOR SERVICE TECHNICIAN S USE ONLY

REMOTE CONTROL MANUAL

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

4. Alignment and Adjustments

CONTROL PANEL INSTRUCTIONS RSQ-4

TEIS Induction Module. 4 cooking zones hob with TAP user interface

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

Refrigeration. Bosch pioneers in design and energy conservation to produce a range of innovative refrigeration products to suit every need.

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

Follett Performance Plus

ST Wiring diagram. Product description. Standard temperature controller. Order number

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

Owner s Manual TABLE OF CONTENTS

TABLE OF CONTENTS REFRIGERATOR-FREEZER. Model No. NR-BN34FX1 Model No. NR-BN34FW1

Remote Controller. <Open the front cover> <ARC452A4>

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

IKS..10,..20 / IK..00 / EK..10 from Index 20. IKS..14,..24 / IK..04 / EK..14 from Index 20, with 4-star freezer compartment

Owner's Manual TABLE OF CONTENTS

Control solutions Biofloor

USER GUIDE 30L 40L 50L. Instruction Manual. IFRIDGE30 (30L), IFRIDGE40 (40L) and IFRIDGE50 (50L) CAPACITY CAPACITY CAPACITY

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

13:00 h REAL FRESHNESS

RF Programmable Room Thermostat User Instructions

USER INTERFACE, PROGRAMS

Wired Controller XK60

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

AUTO CM CM USER GUIDE

Biomedical Freezer 37 38

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Robust Construction, Technology, Quality, Reliability and Repeatability for extreme Tropic Conditions

Easy-Stat. Wireless Programmable Room Thermostat Pt No

TCW 2000 Ice liner refrigerator and freezer PIJ

Operating instructions Page 12

OTF5000 Cryostat. At the cutting edge of sectioning technology

ThermoSaver TM Hot Gas Defrost System

OPERATING MANUAL Enertronic Control System 2

Dixell Installing and Operating Instructions release 7.0

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Model: Available in : Sapphire Black and Glacier White. 1 Series

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

Model: Touch-RF. 1 Wireless Series

CR193-RG70E2(2)BGEU

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

The next level to boost your sales.

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

ThermoSaver TM Hot Gas Defrost System

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

GKv 5710 / 5760 GKv 6410 / 6460

Transcription:

BFFF HUY Partial Frost-free Bottom Combi Nyíregyháza Factory

Nyíregyháza Factory Electrolux Code HUY Nyíregyháza HUY Satu Mare ROA Jászberény HUC

Product Range HUY HUY production: bottom combis Convenience Range Static, 1 or 2 compressors, transfer from HUC (partly from ZS) Partial frost-free (BFFF), new models 4 cabinet heights: 1540, 1750, 1850, 2010 mm

Convenience Range HUY STATIC FROST FREE A + FF FF A + A + A + BOTTOM FREEEZRS 60CM Q1/2005 Q1/2005 Q1/2005 Q1/2005 Q1/2005 Q1/2005 Q1/2005 Q1/2005 Q3/2005 Q3/2005 Type Combi Combi Combi Combi Combi Combi Combi Combi Combi Combi Base Model CB290 1C CB290 2C CB340 1C CB340 2C CB360 1C CB360 2C CB400 1C CB400 2C CBFF340 CBFF380 Factory HUY HUY HUY HUY HUY HUY HUY HUY HUY HUY Energy A+/A A+/A A+/A A+/A A+/A A+/A A+/A A+/A A A Height mm. 1540 1540 1750 1750 1850 1850 2010 2010 1850 2010 Width 595 595 595 595 595 595 595 595 595 595 Gross Capacities 211+79 211+79 226+110 226+110 249+110 249+110 291+110 291+110 249+86 289+86 Net Capacities 208+61 208+61 223+92 223+92 245+92 245+92 287+92 287+92 245+72 285+72 Total Gross/Net 290/269 290/269 336+315 336+315 359/337 359/337 401/379 401/379 334/316 374/357

HUY BFFF BFFF is a new range of partial frost-free bottom combis from HUY BFFF = Bottom Freezer Frost-Free Partial frost-free: static refrigerator frost-free freezer 2 cabinet heights: 1850 mm (245 / 72 l net) 2010 mm (285 / 72 l net) 2 types of controls: electromechanic thermostat electronic Dual Smart

Convenience range, frost free Based on the static range, develop a cost efficient range of Frost free 60cm combi bottom models to meet the growing mass market price for frost free combi bottom products.

Frost Free Generation 1 - Product range CBFF340 CBFF380

Bigger internal capacity The Convenience range offers an extra 10-15% usable storage capacity compared to the actual models with the same external dimensions. This has been obtained with Full height side panels Removing the conventional top and leaving only a front panel Reducing the plinth to 5 cm Optimizing the internal layout of the appliances Model Height Gross cap. Net cap. CBFF340 185cm 340 323 CBFF380 201cm 382 363

Freezer Evaporator Assembly EPS COMPONENT EVAPORATOR KLIXON DEFROST HEATER ALUMINIUM PLATE FAN BRACKET FRONTAL GRID (Air Inlet) FAN MOTOR FAN SUPPORT EVAPORATOR HOLDER DOOR SWITCH

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Thermostats on Battery Evaporator Safety thermostat Defrost end thermostat + 40 C + 8 C

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Freezer Evaporator Access to Parts

Circuit Diagram Electromechanical Version FRIDGE THERMOSTAT DEFROST TIMER DEFROST THERMOSTAT 8 C FREEZER EVAP. FAN FRIDGE DOOR SWITCH COMPRESSOR DEFROST HEATER 200 W SAFETY THERMOSTAT 40 C FRIDGE LAMP

Wiring Diagram Electromechanical Version

Defrost Control Electromechanical Models Timer-controlled defrost Timer motor is in series with main switch (6-3), and will run continuosly when appliance is switched on Defrost interval: 14 hours Defrost time: 30 minutes After defrost interval: compressor off defrost heater on After defrost time : compressor on defrost heater off * * defrost heater will be normally cut off by defrost thermostat (+8 C) before end of defrost time Safety thermostat + 40 C

Defrost Timer Box

Defrost Timer Access

Defrost Timer

Models with Electronic Control ERF2021 + Dual Smart The electronic models are equipped with a new electronic control, consisting of: Power Board ERF2021 User Interface Dual Smart It offers quasi-independent temperature control in the 2 compartments of an 1-compressor combi, using separate temperature sensors and an intelligent balance heater This type of electronic control can be used on models with staic freezer too

Power Board ERF2021

User Interface with LCD

Dual Smart 2 rotary temperature selectors (potentiometers), with maxmiddle-min settings corresponding approximately to: +8 +5 +2 C in refrigerator -16-18 -24 C in freezer LC Display will normally show ambient temperature, user can switch to refrigerator or freezer temperature Functions : Fast Freezing, Shopping, Freezer temperature alarm

Control Panel A B C D E F A. ON/OFF BUTTON B. TEMPERATURE SELECTOR FREEZER C. TEMPERATURE DISPLAY SELECTION BUTTON D. DISPLAY (TEMPERATURES AND FUNCTIONS) E. FUNCTION SELECTION BUTTON F. REFRIGERATOR TEMPERATURE SELECTOR

Display Symbols 1 2 3 4 1. ambient (room) temperature 2. refrigerator 3. freezer 4. or + sign

Display Symbols 6 8 5 7 5. Temperature display 6. Fast freezing symbol 7. Freezer temperature alarm 8. Shopping mode

First Power On Press ON/OFF Display shows ambient temperature and the house symbol Temperature alarm symbol flashing, display backlit in red, acoustic alarm on Press function selection button to cancel the acoustic alarm Set desired temperatures in refrigerator and freezer respectively, using the selector potentiometers (N.B.: it is not possible to set an exact numeric value, but only an approximate angular setting)

Temperature Display normally, the ambient temperature will be shown pressing the temperature selection button will scroll through: refrigerator temperature freezer temperature ambient temperature after 10 seconds without any action, the display will revert to ambient temperature

Switch off Apliance Press ON/OFF for about 1 sec Countdown 3-2-1 Display blank

Fast Freezing Press function selector button until star symbol is shown in display Freezer temperature is set to the value corresponding to the lowest setting To cancel, press function selector button until star symbol disappears Maximum duration: 52 hours

Shopping (Supercool) Press function selector button until shopping symbol is shown in display Refrigerator temperature is set to the value corresponding to the lowest setting To cancel, press function selector button until shopping symbol disappears Maximum duration: 6 hours

Freezer Temperature Alarm Activated when freezer temperature is above - 8 C Display backlit in red, flashing Alarm symbol in display Display shows freezer temperature Buzzer sounds (can be cancelled with function selection button) If freezer temperature drops below - 8 C, the buzzer sound will be cancelled Optical alarm (alarm symbol & red backlighting) remains When pressing the function selection button, the highest temperature reached in the freezer is shown, after which the optical alarm is also cancelled

Wiring Diagram Electronic Version

Sensors and Balance Heater E A. evaporator sensor (only refrigerator) B. refrigerator air sensor C. balance heater D. freezer air sensor E. ambient temperature sensor (on PCB)

Location of Air Sensors Sensors not replaceable (in insulation foam)

Sensor Characteristic 90 80 70 60 50 40 30 20 10 0-40 C -30 C -20 C -10 C 0 C +10 C +20 C +30 C +40 C

Sensor Failure If the resistance of one air sensor ist outside the working range, this will be shown as below: refrigerator air sensor freezer air sensor Compressor : 40 min ON / 40 min OFF A faulty evaporator sensor will not be shown to the user

Location of Balance Heater Balance heater not replaceable (under fridge evaporator)

Wiring to Balance Heater

Balance Heater 16 W The balance heater is controlled by triac ACS2 on the power board By using phase cutting, the heater can be used at variable power The software will determine the power level based on ambient temperature, and of actual demands from the 2 compartments, as measured by the air sensors This ensures a good control at ambient tempeartures as defined for SN/N/ST climatic class (10-38 C) In case of heater failure, the appliance will work more or less satisfactorily (i.e. like a conventional 1-compressor combi) at ambient temperatures above 16 C (N/ST)

Control Limits of Balance Heater at Different Ambient Temp. -15-16 -17 Freezer Packages Temperature -18-19 -20-21 -22-23 10 25 38-24 -25 1 2 3 4 5 6 7 8 9 Fridge Air Temperature

Defrost First defrost routine: 5 hours after power-on, or after power reset The following defrost routines are initiated after 14, 30 or 71 hours - depending on a series of factors: activation of fast freezing, accumulated door opening, compressor duty cycle, time limit reached at previous defrost The defrost routine will start after the next compressor cutout (if the compressor continues to run for more than 2,5 hours, it will be forcibly stopped) Fan off at 2 min after start of defrost routine Heater on 5 min after start of defrost routine Minimum defrost time: 20 min

Defrost Under normal conditions, the defrost heater will be cut off by the fixed bimetal thermostat, which opens at +8 C After the minimum defrost time of 20 minutes has elapsed, the electronic control starts checking if the thermostat has opened Once this has happened, the heater triac will also switch off the supply to mark defrost end Compressor start 5 min after defrost end Fan start 3 min after compressor start

Defrost Safety: Temperature limit + 40 C (thermostat in series with the other side of the heater Time limit 60 min

Service Mode The special functions: forced defrost service mode component activation are not accessible because of the separate bi-polar main switch