INSTALLATION INSTRUCTION Ver

Similar documents
TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL

ULTIMATE REVERSE OSMOSIS SYSTEM

Tap Master Artesian Hydro Gardener Series Installation & Service Manual

Alkaline RO System INSTALLATION MANUAL

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

2-Stage Under Counter Filtration System Model: WP-2 LCV

USER S MANUAL. For use with the following systems: Flow Diagram for 5, 6 or 7-Stage Reverse Osmosis Water Systems (no pump)

INSTALLATION & SERVICE MANUAL

WATER FILTRATION SYSTEM (USF3) OWNER S MANUAL

Installation and Operation Manual

INSTALLATION & SERVICE MANUAL

Installation & Service Guide

ispring Whole House Water Filter Systems USER S MANUAL

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

475 PRO SERIES Reverse Osmosis System Installation & Operation Manual

Reverse Osmosis Filter Change Guide

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

Reverse Osmosis Install Guide

Installation and Operation Manual

Installation Instructions for:

Owner s Manual AQ-RO-BASE. Aquasana OptimH2O Drinking Water System Reverse Osmosis Filtration Technology

WATER FILTRATION SYSTEM (RO5) OWNER S MANUAL

WATER FILTRATION SYSTEM (RO6) OWNER S MANUAL

3-STAGE WATER FILTRATION SYSTEM. INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 1.5

Installation and Operation Manual

1 P a g e. G4 Counter Top OPERATION MANUAL

Installation Instructions for:

3-STAGE WATER FILTRATION SYSTEM INSTALLATION INSTRUCTION & OWNER S MANUAL

GROWMAX WATER Perfect Water for Plants and Gardens

Owner s Manual AQ-RO-3. Aquasana OptimH2O Drinking Water System. Reverse Osmosis plus Claryum Filtration Technology

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL PB-TLRO4H50T INSTRUCTION MANUAL

IMPORTANT! ank You! Model: Twist-In 100 GPD, 3-Stage RO Unit. Installation, Operation & Maintenance Guide

Aquaversa. Installation Guide

Table of Contents. List of Figures

by Water Purification Supplies

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

Home Master Reverse Osmosis System Installation & Service Manual

Home Master Reverse Osmosis System Installation & Service Manual

US Water American Revolution 5-Stage RO System The ONLY RO system on the market that is totally American made!

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Model #: PT3000T36-GOLD

Installation Instructions Residential Reverse Osmosis Drinking Water System

Tap Master Series Reverse Osmosis System Installation & Service Manual

Owners Manual FOR REVERSE OSMOSIS SYSTEMS MODEL ET6500 (P/N )

AquaLiv Water System - Usage & Installation Instructions

Installing the Turbo Floor Model System

KITCHEN FAUCET COS-KF222C

IMPORTANT! ank You! Model: Twist-In 100 GPD 4-Stage RO/DI Unit. Installation, Operation & Maintenance Guide

Installation & Service Manual. Reverse Osmosis Drinking Water Systems 75 GPD with Fully Automatic Noiseless Booster Pump

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Multipure. Drinking Water Systems. Installation, Operation and Maintenance Manual. Multipure Aqua RO System

AQUA ONE. Reverse Osmosis System Model ARO5000. Installation and Service Guide PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

PRO-RO 6-Stage Reverse Osmosis System

MODEL FW-2000 OPERATION MANUAL

IMPACT HEALTH SOLUTIONS. Installation & Service Guide

REVERSE OSMOSIS DRINKING WATER SYSTEM

Drinking Water Purification Systems

5-Stage Reverse Osmosis System

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

RYLE WIDESPREAD FAUCET INSTALLATION

WATER DISPENSER INSTALLATION GUIDE

User Instructions. Visit us at us at RB5, RB10, RB15 Maple Sap Buckets

INSTALLATION MANUAL CRS-3

- Do not Discard these instructions; please save them for later use/reference.

Advanced Two-Stage Drinking Water Filter

TABLE OF CONTENT WARNING: READ ENTIRE MANUAL. FAILURE TO FOLLOW ALL GUIDES AND RULES COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.

Reverse Osmosis System OWNERS MANUAL

HydroCycle Vertical Aeroponic Systems

Puratek Aquarium Reverse Osmosis Installation and Maintenance Manual

How To: PREPARATION REPLACE A KITCHEN SINK

Owners Manual. For Reverse Osmosis Systems MODEL ET4000 ET5000 P/N

INSTALLATION INSTRUCTIONS

1 P a g e MODEL G5CT COUNTER TOP OPERATION MANUAL

TARVER SINGLE HOLE FAUCET INSTALLATION

Parts & Material Included

INSTALLATION AND OPERATIONS MANUAL

BROEG SINGLE HOLE FAUCET INSTALLATION

Installation Instructions

Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot),

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

General System Layout Sketch

SERIES OWNER MANUAL DP1000(B) Please read this manual carefully prior to operating your Drinkpod. Retain for future reference.

LUDGATE SINGLE HOLE FAUCET INSTALLATION

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

Installation Instructions

One Less Thing to Forget...

DWSB-TFC-50 DWSB-50-PUMP

Installation Guide Europa

Top Control Dishwasher

PolyMax H2-24 Dutch Bucket System

R.O. DRINKING WATER SYSTEM

The Coffee Professor Reverse Osmosis System Model Genesis Cafe

INSTALLATION. Glass Panel Doors (select models) CAUTION

kk21 installation Kk21-WF21 Things you might need for the installation: vessel sink,

Aplos Single Handle Basin Bathroom Faucet

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

PWC-500/1000/1010/1500

J-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide

Transcription:

ispring Reverse Osmosis Water Filter Systems INSTALLATION INSTRUCTION Ver 2005-6 Copyright 2005-2015 ISPRING WATER SYSTEMS, LLC. All rights reserved.

Please keep this owner s manual for future reference. It includes the information on how to properly operate and maintain your ispring Reverse Osmosis water filtration system. TABLE OF CONTENT BEFORE INSTALLATION... 2 Inspect the package... 2 Recommended tools list... 2 Operating conditions... 2 Components Identification... 3 Installation Tips... 4 How to use Quick-Connect fitting... 4 To connect:... 4 To disconnect:... 4 How to use Compression fitting with brass Nut, Collar, and tube Insert... 5 How to drill a hole on sink or counter-top... 5 Installation Steps... 7 Step 1: Install Feed Water Adapter (AFW)... 7 Step 2: Install Drinking Water Faucet... 7 Step 3: Install Drain Saddle... 8 Step 4: Install the Vertical Filters: Stages 1, 2, and 3... 8 Step 5: Install Tank Shut-off Valve (TSV)... 8 Step 6: Install Reverse Osmosis Membrane... 9 Step 7: Tubing Hook up (model specific sub-steps are marked with * )... 9 Step 8: System Start Up (model specific sub-steps are marked with * )... 10 SYSTEM MAINTENANCE... 12 Stages 1 3 pre-filters: Replace every 6 12 months, or sooner if water flow gets slow... 12 How to change in-housing cartridges in 1st 3rd pre-filter stages... 12 Stage 4 RO membrane: Replace every 2 3 years or sooner if TDS level starts increasing... 13 How to change reverse osmosis membrane... 13 Stage 5 T33 fine carbon: Replace every 12 months... 13 How to change inline cartridges in 5th 7th stages... 13 O-rings: Replace every 3 years or sooner if leak happens at O-ring... 13 Extra Installation... 14 UV Lamp (part# ispring UVB11) and Ice maker kit (part# isrping ICEK)... 14 www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 1

Thank you for choosing the ispring Reverse Osmosis Water Filtration System. It was built from quality components, and has earned WQA GOLD SEAL certification against NSF/ANSI STANDARD 58 for performance and material safety. Please check the attached ispring RO Systems WQA Gold Seal Certification for details. BEFORE INSTALLATION Inspect the package Please open the box, and take all the components and tool kit out. Inspect them to ensure that nothing is damaged during shipping. If any part is cracked or broken, please immediately contact ispring Customer Support for replacement. Identify and get familiar with the components. Recommended tools list Variable speed drill with two bits: ¼ (for drilling a hole on PVC drain pipe), ½ hollow diamond (for drilling a hole on countertop for drinking faucet) 5/8, 9/16 open-end wrench, or adjustable wrench, pliers Phillips screwdriver Scissors or utility knife Operating conditions Maximum water pressure: 80 psi, or pressure regulator (part no. APR70) is required if there is high water pressure or water hammer) Minimum water pressure: 40 psi, or booster pump is needed to improve RO efficiency Water temperature: 40 100 F (4-37 C) (This RO system is NOT designed for HOT water) Maximum TDS: 750 ppm Install this RO system in a location where it is safe from hot/cold weather and direct sunlight. Avoid hitting, falling, or dragging as they may cause cracks and leaks. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 2

Components Identification RO machine head (membrane not yet installed) 3 Pre-filter housings and cartridges Storage tank Drinking faucet with installation kit Feed Water Adapter (AFW) 4-color tubing set Drain saddle ¼ Tank valve Housing wrenches Teflon tape Spare Housing O-rings x 3, Elbow Fitting x 2, Lock Clips Water Detector (optional) www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 3

Installation Tips How to use Quick-Connect fitting Figure 1 To connect: 1. See Figure 1. Check and cut the tubing end squarely and cleanly with utility knife or scissors. 2. Make a mark at the end of tubing. The lengh is about ½ inch, the depth of the fitting body. 3. Fully insert the tubing until the mark is about to disappear. This ensures that it is sealed by the O-ring near the bottom. Figure 2 Figure 3 To disconnect: 1. See Figure 2 and 3. Remove the blue Lock Clip. 2. With two fingers PUSHING IN and PRESSING DOWN the Lock Sleeve to eliminate the Gap that the blue Lock Clip occupied, pull the tubing out. (Pressing down the Lock Sleeve releases the spring-loaded steel teeth that grab the tubing inside the fitting body). www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 4

How to use Compression fitting with brass Nut, Collar, and tube Insert Compression fitting is used to connect the PVC tubing to the threaded metal inlet with a tapered open end, such as the refrigerator water inlet, drinking faucet water inlet, etc. Figure 4 1. Slide the Nut, Collar onto the end of tubing 2. Fully insert the Insert into the open end of tubing 3. Slide the Collar to be close to Insert and fit into the tapered open end of the thread matal inlet. 4. Screw on the Nut and tight it up. The Nut compresses the plastic Collar onto the tapered matal surface and creates a water seal between them while the Insert hardens the tubing. How to drill a hole on sink or counter-top 1. It s highly recommended to watch the YouTube video How To Drill Faucet Holes. 2. Choose a half inch Diamond Core Bit for granite, and a titanium drill bit for steel. Do NOT use a hammer drill on nature stone, glass, and ceramic. 3. An indent should be made with a punch on steel before drilling to help guide the bit. 4. Use caution when drilling on a Porcelain sink, as it could be easily chipped. Set drill speed on slow. Press the bit downward firmly until breaking through the slippery surface. 5. Use coolant to disperse heat. Choose water for granite, and oil for steel. Use the Water Suction Cup to hold coolant inside and prevent the drill bit from slipping. 6. Starting at slowest speed, hold the drill firmly and vertically and prevent the drill bit from slipping on the counter. 7. Once breaking through the smooth surface, swirl the drill a little to apply pressure in a circle evenly. 8. Be patient and deliberate. It can take 20 40 minutes to drill through one inch. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 5

Sample Installation Figure 5 A. Source water from Feed Water Adapter B. Source water to water inlet next to 1st stage C. Waste water from Flow Restrictor D. Waste water to Drain Saddle E. RO water from Automatic Shut-off Valve F. RO water to Storage Tank G. RO water from 5th stage H. RO water to Drinking Faucet An Ice Maker Kit (part# ispring ICEK) can be purchased separately to feed RO water to refrigerator and get crystal clear ice cubes and great tasting water at ease. It could make Drinking Water Faucet not absolutely necessary. Figure 6 www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 6

Installation Steps Before you begin installation, it is highly recommended that you watch the video ispring reverse osmosis installation on YouTube. Note: Steps 1 7 are independent, and can be performed in any order. Step 1: Install Feed Water Adapter (AFW) 1.1 See Figure 5. Turn off the Cold Water Line via the Cold Water Supply Valve (CWSV) under the sink. Open the kitchen faucet to release pressure and make sure water has stopped before proceeding to the next step. Get a towel or bucket to catch any water drips. Disconnect Kitchen Faucet Connector (KFC) pipe from CWSV. 1.2 (Refer to AFW user manual). Check O-ring inside AFW female end, and twist it onto CWSV. Tighten it up using wrench or pliers. 1.3 Twist KFC onto the male end of AFW. Turn the handle of AFW to cross (OFF) position. Turn on CWSV slowly, check and fix any leaks. 1.4 Connect the 1/4 RED tubing to AFW. Step 2: Install Drinking Water Faucet 2.1 If your kitchen sink does not have an existing ½ hole, you will have to drill one. (Refer to How to drill a Hole on Sink or Counter-top). Wipe clean and dry the area. (Contact us for larger front plate and washer if the hole is too big to cover). 2.2 Remove blue protection film from the front plate, slip it on the faucet thread, and slip on the black rubber washer. Insert the faucet thread portion into the hole. Optional plumber glue or sealer could be used. 2.3 Under the sink, tighten the back rubber washer, lock washer with nut. 2.4 (Refer to How to use compression fitting). Slip the compression fitting nut and collar on the BLUE tubing, push the insert into the tubing, insert it into the faucet end, and tighten up the nut. Pull the tubing to check if it is secure. Figure 7 www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 7

Step 3: Install Drain Saddle 3.1 Choose a spot on the drain pipe that is convenient for installing the drain saddle and tubing. Horizontal pipe is recommended to minimize the dripping sound. 3.2 Drill a 1 /4 hole on the drain pipe; paste the black sticky pad around the hole. 3.3 Cut the BLACK tubing end a bit to make a 45 degree angle. Slip the plastic nut and front plate on the tubing. Insert the tubing into the 1 / 4 hole on the drain pipe, install the back plate and tighten two screws with hex nuts while the tubing remains in the hole. 3.4 Tighten the nut on the Drain Saddle by hand. Pull the tubing to check if it is secure. Step 4: Install the Vertical Filters: Stages 1, 2, and 3 4.1 Make sure that the O-ring is seated inside the groove on top of the filter housing. (Figure 10). Food-grade silicon jelly may be used to help the O-ring stay in place and seal better. 4.2 Filter cartridges are preserved in shrink wrap. Note the direction sign on the sticker before removing the wrap (GAC stage). 4.3 When placing the filter cartridge into its housing, make Figure 12 sure it is centered and the knob protruding from the bottom of the housing fits in the central hole of the filter. 4.4 Screw the housing, with filters attached, onto the housing caps (caps are pre-assembled on the machine head). The cap also has a center knob which should be inserted into the center hole of the filter cartridge. Twist the housing on in a clockwise direction by hand, and then use a housing wrench to tighten it up for about 1/4 1/2 turn. Do not over tighten. This can cause leaks and make it difficult to unscrew the housing when replacing filters. 4.5 Follow the steps 1.1 1.4 to install the GAC and CTO filters. *Note* the second stage GAC is the only filter that must go in a certain direction. Make sure that the end with the rubber washer faces up, thereby attaching to the housing cap. Step 5: Install Tank Shut-off Valve (TSV) 5.1 Wrap 10-15 turns of Teflon tape clockwise (looking from top) onto the metal thread at the top of the tank. 5.2 Screw (clockwise) the Tank Shut-off Valve on and tighten up by hand. Do not over tighten. 5.3 Connect the YELLOW tubing onto the Quick-Fitting of TSV. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 8

Step 6: Install Reverse Osmosis Membrane Figure 8 Figure 9 6.1 Open the membrane housing screw cap. First, you will need to disconnect the white 1 / 4 tubing from the Inlet quick-fitting on the membrane housing cap (refer to How to Use Quick-Fitting section), and then unscrew (counter-clockwise) the cap. A thick rubber band can be slipped on the housing body for a stronger hand hold. 6.2 Remove the membrane from its sealed bag. Follow the flow direction sign on the membrane, and firmly insert the membrane into the housing with the smaller end that has two black O-rings heads first until the bigger end is even with the housing opening. See Figure 8-9. 6.3 Before twisting the housing cap back on, check that the O-ring is evenly snagged on the membrane housing (cap does NOT have O-ring). Hang tight and tighten up for about 1 /4 1 /2 turns using a small plastic housing wrench, but do not over tighten. DO NOT reconnect the tubing to inlet on cap at this point (will do it in system start up). Step 7: Tubing Hook up (model specific sub-steps are marked with * ) 7.1 See Figure 5 and Figure 10 RCC7P & RCC7 TOP VIEW, note connection points A-B, C-D, E-F, and G-H. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 9

Figure 10 7.2 Facing the ispring logo up front, the pre-filter 1st stage is located on the right hand side. Connect the RED tubing Feed Water Adapter (AFW) (point A) to the elbow fitting (point B). 7.3 Connect the Flow Restrictor (point C), which is a 3-inch long cylinder with a FLOW sign laying beside the membrane housing, to the Drain Saddle (point D) with the BLACK tubing. 7.4 On the right side of the Post Carbon Filter (FT15 5 th stage), connect the Tee-fitting (point E) and the Tank Valve (point F) with the YELLOW tubing. 7.5 * Model without UV/AK/DI: at left end of FT15, insert the BLUE tubing (links to RO faucet) into the elbow fitting. * Model with UV/AK/DI: RO water flows out of point G at FT15 and flows into the left end of next stage. So the BLUE tubing (links to RO faucet) should be connected at the final end of the last stage, which could be the UV/AK/DI filter. 7.6 Connect the other end of the BLUE tubing to the RO faucet (refer to How to use compression fitting). 7.7 You may organize the tubings, but make sure to leave enough length so the filter system can be moved freely in and out of the cabinet when replacing filters. 7.8 You may hang the system using two 10 x 1-1/4 Phillips Flat Wood Screws. This will make replacing filter cartridges easier. Step 8: System Start Up (model specific sub-steps are marked with * ) * If your model has a UV stage, do not plug in power until the system is fully flushed 8.1 Make sure that all tubings are not kinked. Turn Tank Shut-off Valve OFF (cross). Prepare a bath towel to catch any water leak. 8.2 To avoid the residual carbon in the first three stages from getting into the RO membrane, the tubing to the inlet of the RO membrane housing cap was left disconnected. Flush the first three stages into a bucket until the water turns clear, and re-connect the tubing to the RO membrane. (You may do this whenever you change the first three stages). 8.3 Turn on (inline) Feed Water Adapter valve (AFW), and then slowly turn on the Cold Water Supply Valve (CWSV) and check for leaks. The top 3 causes of leaks are 1) the tubing was not fully inserted into the quick-connect fitting. 2) the O-ring was not in place or kinked. 3) the Housing/Cap was not tightened up or off threads. 8.4 * Plug in booster pump power if your model has one. 8.5 Within 5 minutes, RO water should start dripping. Let it run for at least 10 minutes. This flushes the system except the tank. Water is black due to loose carbon from new carbon filters (step 8.2 could be taken to expedite the flush). It will turn clear with some air bubble. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 10

8.6 Shut off the RO Drinking Faucet. Turn on the Tank Shut-off Valve. Wait for the tank to be filled up. It may take 1.5 hours in warm summer or 3 hours in cold winter to fill up a 3.2 gallon tank with about 2.5 gallons holding capacity. 8.7 After two hours, turn on the RO Drinking Faucet to flush out all the water in the tank. DO NOT use the first tank of water. The water out of the faucet should be a much stronger stream since the water pressure was built up to 35-40 psi when being filled up. When the water flow changes back to a trickle, it means the tank is empty. 8.8 * Plug in the UV power and observe if the RO faucet turns the UV on/off through the Flow Sensor Switch. 8.9 The reverse osmosis membrane is the key part for the effective reduction of total dissolved solids (TDS) and that product water shall be tested periodically to verify that the system is performing properly. If the TDS of the source water is 100ppm, the RO water should be less than 10ppm (Rejection rate >90%). 8.10 Check for leaks daily for the first two weeks after installation. Furthermore, a bucket can be put under the system in case of any leaks, and a Flood Alarm can be used together for better protection. Congratulations! You have successfully installed the ispring Reverse Osmosis Water Filtration System! Start enjoying the cleanest water right from your tap! www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 11

SYSTEM MAINTENANCE This RO system is designed with ease of use and low maintenance in mind. If you change the filter cartridges as suggested below, and check TDS level periodically, the system will work properly for many years. Note: stage 6 or 7 only exists in certain models. For a filter pack supply, visit 123Filter.com or Google Model replacement filter online, in which Model is the model number of the system, e.g. RCC7 Stages 1 3 pre-filters: Replace every 6 12 months, or sooner if water flow gets slow. The frequency depends on the source water quality and water usage. They could last longer in city water, and shorter in well water. Different areas have good or bad water. Some customers reported they had to replace the 1st stage every 1-3 months when they saw through the clear housing where heavy sediments and particles turned the white cartridge into dark brown. Some customers reported they could replace them every 12 months. To protect the RO membrane in the 4th stage, it is required to replace the pre-filters at least every 12 months. How to change in-housing cartridges in 1st 3rd pre-filter stages 1. Shut off the water supply valve and tank valve, open the faucet to depressurize. Place a bucket or towel under the unit to catch water spills. 2. If there is enough room under the sink and filter system is hung on wall, it could be easier to twist the filter housing off without taking the unit off the wall. Otherwise, it could be easier to pull the system out, lay it down and work towards the housing bottom. Please be careful with tubing connections when pulling the system out. 3. Twist off the filter housing in a counter-clockwise direction when looking from the bottom. Use a housing wrench (the bigger one) if necessary. 4. Refer to Installation Step 1.1 to install a new vertical filter cartridges and twist the housings back on. Remember not to over tighten or it will be hard to open next time. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 12

Stage 4 RO membrane: Replace every 2 3 years or sooner if TDS level starts increasing. Check the TDS level at least once a month to monitor the system performance. The rejection rate should be above 90% (NSF/ASIN STANDARD 58 for RO water filter). How to change reverse osmosis membrane Figure 11 Figure 12 1. Reverse osmosis membrane usually last about 2 3 years, depending on the source water quality and the replacement schedule of the three pre-filters. 2. To ensure system performance and water purity, filter cartridges must be replaced on schedule. Use the TDS meter periodically to check water purity 3. Shut off the water supply valve and tank valve, open the faucet to depressurize 4. Place a bucket or towel under the unit to catch water spills. 5. Remove the tubing from the inlet fitting on the membrane housing cap. Use a housing wrench or by hand to twist off the housing cap in a counter-clockwise direction looking from inlet. 6. Pull out the old membrane. Use scissors or pliers to apply leverage if necessary. 7. Clean the housing using hot water and optional scent-free dish soap. Rinse thoroughly. Cut open the small end of the sealed bag of a new RO membrane, hold the new membrane with the bag, and insert it into housing without touching the membane with your bare hand, which may contaminate it. 8. Check the O-ring on the open end of the membrane housing. It is recommended to replace it every 3 years to prevent leaks. 9. Twist the membrane housing cap back on by hand. Use a wrench for a final ¼ turn if necessary. DO NOT over tighten. Stage 5 T33 fine carbon: Replace every 12 months Unscrew the elbow fittings on both ends, put them on the new cartridge, and use new Teflon if necessary. How to change inline cartridges in 5th 7th stages 1. Please note that the 5th - 7th stages (model specific) have directions and each end may have a different kind of fitting. 2. Disconnect the tubing from the Quick-Connect fitting, unscrew the fitting, unwrap a new cartridge, replace the Teflon tape on the fitting threads if necessary, follow the sign on the label to screw the correct fitting on each end, and reconnect the tubing. O-rings: Replace every 3 years or sooner if leak happens at O-ring. The package comes with 3 spare O-rings for the pre-filter housing, and 1 spare O-ring for the membrane housing. Please save them with this manual. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 13

Extra Installation UV Lamp (part# ispring UVB11) and Ice maker kit (part# isrping ICEK) Figure 13 Flow Sensor Switch for UV lamp The models with a UV stage have a U letter in model number, such as RCC7U, RCCAK-UV, RCC1UP-AK. The UV module comes pre-installed on the models with UV. It should function out of the box. The photos above are for a better understanding about how the components are assembled and work together. The Ice Maker Kit (model#: ispring ICEK) can be purchased separately to feed RO water to a refrigerator and get crystal clear ice cubes and great tasting water. It would make a Drinking Water Faucet not absolutely necessary. www.123filter.com (678) 261-7611 sales@ispringfilter.com Page 14