Drawing Submittal Package

Similar documents
Drawing Submittal Package

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Technical Data Submittal Document

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Technical Data Submittal Documents

LMR Electric Fire Pump Controllers Features

LMR Electric Fire Pump Controllers Features

Model GPP Full Service Reduced Voltage Part Winding Electric Fire Pump Controller

FDF Foam Pump Controllers Features

Model GPA Full Service Full Voltage Across the Line Start Electric Fire Pump Controller

FD30 Full Voltage - Across the Line July 2011

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPW + GPU Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller with Automatic Power Transfer Switch

Technical Data Submittal Documents

FT60 Reduced Voltage - Autotransformer

Model GPY + GPU Full Service Reduced Voltage Wye-delta Open Electric Fire Pump Controller with Automatic Power Transfer Switch

FT20 Full Voltage - Limited Service. Electrically and Mechanically

Model GPW Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Model GPS Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller

Soft Start Series MP700 Solid State, Reduced Voltage

Transfer Switch Features

Across-the-Line SERIES MP300 Combined Manual and Automatic

Transfer Switch Features

Variable Frequency Drive SERIES MP800 VFD

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

FDJ SERIES Jockey Pump Controllers Features

Fire Pump Controllers Medium Voltage Controllers

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

DIESEL Engine Fire Pump Controllers Features

Fire Pump Controllers Foam (Additive) Controllers

SECTION Fire Pumps

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Options for Diesel Fire Pump Controllers

SECTION AUTOMATIC TRANSFER SWITCHES

DIESEL Engine Fire Pump Controllers Features

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

SECTION AUTOMATIC TRANSFER SWITCHES

Guide Specification Model CTG Automatic Transfer Switch

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Model GPD Diesel Engine Driven Fire Pump Controller

Microprocessor Based Wye-Delta Reduced Current Type Starting

EATON LMR Plus Electric Fire Pump Controllers

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

INSTALLATION AND MAINTENANCE MANUAL FOR ELECTRIC FIRE PUMP CONTROLLERS MODEL GPX

PILOT SERIES MPT700TS

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

PUMP CONTROL CENTER (PCC)

A. This Section includes transfer switches rated 600 V and less, including the following:

CONTENTS AUTOMATIC TRANSFER SWITCHES

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Remote Alarm Panels Features

FTA550 JOCKEY PUMP CONTROLLERS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION AUTOMATIC TRANSFER SWITCHES

Specification/ Data Sheet

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

70E Pressure Booster. Bell & Gossett. Bulletin D-215D. Efficient Operation. Easy to Select and Install. Quick Set-up through EZ Start

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

MPT Electric Fire Pump Controller

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION 4000 LIFT STATIONS

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Table of Contents. Protective Relays

A New Standard of Excellence

DGC-500 DIGITAL GENSET CONTROLLER

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SECTION ROTARY-SCREW WATER CHILLERS

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Commercial and Light Industrial Fire Alarm Control Panel

CHECKFIRE 210 Detection and Actuation System

Transcription:

Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch Contents: Submittal Data Sheets Dimensional Data Wiring Schematics Field Connections NOTE: The drawings included in this package are for controllers covered under our standard offering. Actual AS BUILT drawings may differ from what is shown in this package August 2012

Submittal Data Sheet Model GPL + GLU Electric Pump Controller From automatic power transfer switch 3L2 3L1 4L2 1M T2 T1 M CR4 1M 3L1 3L2 Starting Method: Full Voltage Across the line (Direct on line) Typical Voltage Applied at Start: 100% Inrush Current: 6 x normal load current Starting Torque: 100% Motor Type: Across the line (Direct on line) No. of Contactors: 1 at 100% of horsepower Line current % of full load 600 Across-the-line starting Locked rotor current No. of Motor Connections & Sizing: 3 at 100% of Full load Current (FLC) 450 300 150 Full load current 20 40 60 80 100 Percent of motor speed (%) Shortcircuit Withstand Rating Standard 208V to 240V - 1ph - 50/60Hz Normal Power Alternate Power 65,000 A Listings, Approvals and Certifications Enclosure Built to NFPA 20 (latest edition) Underwriters Laboratory (UL) New York City Protection Rating Standard: NEMA 2 Optional NEMA 12 NEMA 3 NEMA 3R NEMA 4 Accessories Wall mounting lugs Keylock handle UL218 - Fire pump controllers UL1008 - Automatic power transfer switches for fire pump controllers CSA C22.2 No. 14 Industrial Control Equipment Accepted for use in the City of New York by the Department of Buildings NEMA 4X-304 sst painted NEMA 4X-304 sst brushed finish NEMA 4X-316 sst painted NEMA 4X-316 sst brushed finish Paint Specifications Red RAL3002 Powder coating Glossy textured finish July 2012 1

Submittal Data Sheet Model GPL + GLU Electric Pump Controller Limitations Pressure Sensing Surge Suppression Across the line starting only Horsepower rating of maximum 30hp Can only be installed where acceptable by the authority having jurisdiction Not accepted in FM insured property Pressure transducer for fresh water application Pressure sensing connection 1/2 Female NPT Rated for 0-500psi working pressure (calibrated at 0-300psi) Internally mounted Surge arrestor rated to suppress surges above line voltage Disconnecting Means & Locked Rotor Protector Circuit breaker (inverse time non ajustable) rated between 150% and 250% of motor full load current Service Entrance Rating Emergency Start Handle Electrical Readings Pressure Readings Pressure and Event Recorder Suitable as service entrance equipment Push and slide to lock Across the line start (direct on line) Voltage phase to phase Amperage of each phase when motor is running Continuous system pressure display Cut-in and Cut-out pressure settings Pressure readings with date stamp Event recording with date stamp Under regular maintained operation, events can be stored in memory for up to 5 years Data viewable on operator interface display screen Downloadable by USB port to external memory device July 2012 2

Submittal Data Sheet Model GPL + GLU Electric Pump Controller Audible Alarm Visual Indications and Alarms 4 alarm bell - 85 db at 10ft. (3m) Power available Locked rotor Manual start Phase reversal Periodic test Deluge valve start Motor run Fail to start Remote automatic start Pump room alarm Low discharge pressure Remote manual start Motor trouble Low pump room temperature Overcurrent Phase loss Pump room temperature (ºF or ºC) Undercurrent Phase unbalance Pump on demand/automatic start Undervoltage Low water level Emergency start Overvoltage Remote Alarm Contacts ViZiTouch Operator Interface Operation SPDT-8A-250V.AC Power available Phase reversal Motor run Common pump room alarm Overvoltage Undervoltage Phase unbalance Low pump room temperature High pump room temperature Common motor trouble Overcurrent Fail to start Undercurrent Ground fault Embedded microcomputer with software PLC logic 4.2 color touch screen (HMI technology) Upgradable software Automatic Start Manual Start Stopping Timers Actuation Mode ** Can only be used if approved by the AHJ Expandable storage Multi-language Start on pressure drop Remote start signal from automatic device Start pushbutton Run test pushbutton Deluge valve start Remote start from manual device Manual with Stop pushbutton Automatic after expiration of minimum run timer ** Minimum run timer** (off delay) Field Adjustable & Visual Countdown Sequential start timer (on delay) Periodic test timer Pressure Non-pressure Visual Indication Automatic Non-automatic July 2012 3

Submittal Data Sheet Model GPL + GLU Electric Pump Controller Automatic Power Transfer Switch Surge Suppression Surge arrestor rated to suppress surges above line voltage Isolating switch and circuit breaker assembly: Door interlocked in the ON position Isolating switch rated not less than 115% o f motor full load current Disconnecting Means Circuit breaker continuous rating not less than 115% of motor full Overcurrent sensng nonthermal type, magnetic only Instantaneous trip setting of not more than 20 times the motor full Common flange mounted operating handle Operate shunt trip to open circuit breaker Locked Rotor Protector Factory set at 600% of motor full load current Trip between 8 and 20 seconds Alternate (emergency) isolating switch in the OFF position Alternate (emergency) voltage phase to phase Visual Indications Transfer switch in normal position Transfer switch in alternale (emergency) position Transition timers Transfer switch test pushbutton Bypass for re-transfer and generator shutdown Electrically operated and mechanically held in the normal or alternate position Provision for manual operation Remote Alarm Contacts SPDT-8A-250VAC Isolating switch in the OFF position Transfer switch in normal position Transfer switch in alternate (emergency) position Time Delays Momentary normal power outage override (factory set at 3 sec - field adjustable 1 to 3 sec) Alternate (emergency) power available delay (factory set at 3 sec - field adjustable 1 to 3 sec) Transfer trouble delay (factory set at 20 sec - field adjustable 1 to 60 sec) Retransfer to normal (factory set at 5 min - field adjustable 1 to 20 min) Generator cooldown (factory set at 5 min - field adjustable 1 to 20 min) Voltage Sensing Transfer to alternate (normal power dropout) 85% of nominal - field adjustable 0 to 100% Phase reversal transfer to alternate Retransfer to normal (normal power pickup) 90% of nominal - field adjustable 0 to 100% Audible Alarm (AIS Open) 4 alarm bell - 85 db at 10ft. (3m) Generator Start Connection SPDT-8A-250V.AC July 2012 4

Submittal Data Sheet Model GPL + GLU Electric Pump Controller A4 A8 A9 A10 A11 A13 A16 B11 B11B B19 B21 C1 C4 C6 C7 C10 C11 C12 C14 C15 C16 C17 C18 C19 C20 C21 C22 Flow switch provision Foam pump application w/o pressure transducer and run test solenoid valve Low zone pump control function Medium zone pump control function High zone pump control function Non-pressure actuated controller w/o pressure transducer and run test solenoid valve Lockout/interlock circuit from equipment installed inside the pump room Built in alarm panel (120V.AC supervisory power) providing indication for: Audible alarm & silence pushbutton for motor run, phase reversal, loss of phase. Pilot lights for loss of phase & supervisory power available Built in alarm panel same as B11 but 220-240VAC supervisory power High motor temperature thermistor relay c/w visual indication and alarm contact Ground fault alarm detection c/w visual indication and alarm contact Extra motor run alarm contact Periodic test alarm contact Low discharge pressure alarm contact Low pump room temperature alarm contact High water reservoir level alarm contact High electric motor temperature alarm contact High electric motor vibration c/w visual indication and alarm contact Pump on demand/automatic start alarm contact Pump fail to start alarm contact Control voltage healthy alarm contact Flow meter valve loop open c/w visual indication and alarm contact High water reservoir level c/w visual indication and alarm contact Emergency start alarm contact Manual start alarm contact Deluge valve start alarm contact Remote automatic start alarm contact C23 C24 Cx D1 D1A D10 D14 D14A D14B D15 D18 D19 D20 D21 D26 D26A D27 D27A D28 D34 D35 D36 D36A D37 E1 E2 E3 F2 F2A F2B Remote manual start alarm contact High pump room temperature alarm contact Additional visual and alarm contact (specify function) Low suction pressure transducer for fresh water rated at 0-300PSI with visual indication and alarm contact Low suction pressure transducer for sea water rated at 0-300PSI with visual indication and alarm contact Omit mounting feet (when applicable) Anti-condensation heater & thermostat (fire pump section only) Anti-condensation heater & humidistat (fire pump section only) Anti-condensation heater & thermostat & humidistat (fire pump section only) Tropicalization CE Mark with factory certificate French labelling Spanish labelling Other languages Modbus RTU provision Modbus TCP/IP provision Motor heater connection (external single phase power source and heater on/off contact) Motor heater connection (internal single phase power source and heater on/off contact) Customized drawing set Field programmable I/O board - 8 Input / 5 output Field programmable I/O board - 8 Input / 10 output Redundant pressure transducer for fresh water rated for 0-500PSI (calibrated at 0-300PSI) Redundant pressure transducer for sea water rated for 0-500PSI (calibrated at 0-300PSI) Window kit for operator interface Permanent load shedding contacts Temporary pump motor start period load shedding contacts Temporary & permanent load shedding contacts Anti condensation heater & thermostat (transfer switch section only) Anti condensation heater & humidistat (transfer switch section only) Anti condensation heater & thermostat & humidistat (transfer switch section only) Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. July 2012 5

Submittal Data Sheet Model GPL + GLU Electric Pump Controller ViZiTouch Operator Interface 1 3 2 4 5 6 7 8 9 10 11 12 13? 14 1 - Power LED 2 - Color touch screen 3 - Alarm LED 4 - HOME page button 5 - ALARM page button 6 - CONFIGURATION page button 7 - HISTORY page button 8 - USB port 9 - START button 10 - TRANSFER SWITCH TEST button 11- Contextual navigation pad 12 - STOP button 13 - RUN TEST button 14 - HELP button July 2012 6