ClimaSys Resistance heaters Selection guide

Similar documents
Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Enclosure Heaters and Fan Heaters

HEATING. Anticondensation Heaters

CR 027 PTC Fan Heater W

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Cooling unit Mechanical control

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

Thermal Management Products & Accessories for Enclosures

Stego accessories for cabinets

Anti Condensation Heaters

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

Rittal roof-mounted fans Efficiency on top

Application. Specifications. Finish

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Rittal roof-mounted fans

Performance Data. curus Component Recognized; File No. E IP 20

LC1 Modular Ceiling Loudspeaker Range. en Installation note

THERMASREG TR 040 THERMASREG TR 060

ClimaSys Technical Guide Preventing condensation

SELECTION GUIDE. Industrial Thermoregulation. Products for panels and enclosures

Power. Average noise level (DIN EN ISO 4871)

Fan speed controller Type Saginomiya XGE

Thermal management for your cabinets!

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Life insurance for your electronics

Thermal control. Overview. Adjustable thermostats. Double-adjustable thermostat. Different installation methods. The new quick-fixing systems:

electronics Protection

THERMAL MANAGEMENT. Outdoor 3.13 to

+ = ECO-STAR System. Ecology Series (Distribution boxes) + Star Series (Boxes for industrial sockets) ECOLOGY Technical Specifications

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Positive Temperature Coefficient (PTC2) Heater Manual

Eldon Product Overview

Type CODE Speed Heating Cooling

RIVERA P5000. Folding awning P5000

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Heaters, Thermostats and Hygrostats

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

CMD420 / CMD421 Series

WHITE PAPER: Thermal Management Solutions

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

Contents. External and internal tight cabinets, heating and cooling systems. IP55 outdoor distribution cabinets 1-4

LB3-PCx50 Premium Cabinet Loudspeakers

Anti-condensation and climate control

The insurance for your regulation!

Accessory Products

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Advantages / Characteristics

Interface Modules for SENTRI

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Quatro canal Super-powered climate control for 4-pipe systems

Ledinaire Batten Simply great LED

Acessories BROCHURE JUNHO 2013

DTA. Motor thermistor relay. Benefits. Description

Line Smoke Detector LRMX

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

NGC-40 Advanced Heat-Tracing Control System

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Cabinet Cooler Systems

Loadstar AC/DC Systems

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

CONTROLS FOR ELECTRIC RADIATORS AND TOWEL RAILS

Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Maximum rated temperature Maximum ambient temperature

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Engineering Guideline. pac- Carriers Type Universal

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Tubular Heaters. Finned Tubular Heaters. Threaded Immension Heaters

Safe Enclosure Cooling

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Heatless Desiccant Compressed Air Dryers

Easy installation Certified for zones 1 and 21 High IP degree of protection

Product Management, Rev 3 December 2009

Bulletin 1608N MiniDySC Dynamic Sag Corrector

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

Trench Heating Katherm QK

CoreLine Waterproof the clear choice for LED

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Marathon Special Products

Superdew 3. Hygrometer. Operating Instructions

Q (m3/h)

TROPO 15W Dimmable LED Driver

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Transcription:

Selection guide Insulated resistance heaters Power W Voltage Type of connection Terminal block Cable 87504 10 12-36 DC X 87501 10 110-250 AC X 87512 21 12-36 DC X 87502 21 110-250 AC X 87518 55 12-36 DC X 87506 55 110-250 AC X 87521 55 270-420 AC X 87523 102 12-36 DC X 87509 102 110-250 AC X 87528 102 270-420 AC X 87536 147 12-36 DC X 87515 147 110-250 AC X 87540 147 270-420 AC X 94

Insulated resistance heaters with fan Power W Voltage Type of connection Terminal block Cable 87555 177 230 AC X 1 Ventilation systems Thermofans Power (W) Voltage Type of connection Terminal block Cable 17571 400/550 120 AC X 17526 400/550 230 AC X 2 Air-air exchangers Power W Voltage Type of connection Terminal block Cable 17504 10 12-36 DC X 17501 10 110-250 AC X 17512 20 12-36 DC X 17502 20 110-250 AC X 17510 20 270-420 AC X 17518 55 12-36 DC X 17506 55 110-250 AC X 17521 55 270-420 AC X 17523 90 12-36 DC X 17509 90 110-250 AC X 17528 90 270-420 AC X 17536 150 12-36 DC X 15515 150 110-250 AC X 17540 150 270-420 AC X 3 Air-water exchangers with fan Fixing accessories Power W Votlage Type of connection Terminal block Cable 17570 250 115 AC X 17531 250 230 AC X 17581 400 115 AC X 17554 400 230 AC X 17572 200 115 AC X 17555 200 230 AC X Description 21432 Set of 5 studs 21431 Set of 5 studs, DIN rails and screws 7 Calculation and selection aid software 4 Cooling units 5 6 Control devices 95

INSULATED RESISTANCE HEATERS 10 W and 20 W insulated resistance heaters General characteristics Compact resistance heater which prevents the formation of condensation and ice. Designed for a better natural convection and a high thermal performance. Extremely compact resistance heater. Extruded aluminium body. Features a plastic cover UL94 V0, light grey, to avoid direct contact with the aluminium radiator. Surface temperature limited to 70 C. Fitted with an insulated cable. Double insulated. PTC technology range. Quick attachment by clips into 35 mm DIN rail. Certifications compliant with UL and VDE and EC Marking. Usage conditions The resistance heaters should be used with a hygrometer switch or a thermostat (thermostat 87561 or 87558, hygrostat 87560) to control temperature or humidity within the enclosure. The enclosure should be sealed to prevent the entry of external air. An electrical protection device should be installed on the supply side of the unit. Characteristics 87501 87504 87502 87512 Power at 0ºC 10W 20W Voltage 110-250V 12-36V 110-250V 12-36V Technology PTC Surface temperature <70ºC, except for grill for higher protection Electrical connection Insulated cable Quick attachment By clips into 35 mm DIN rail (EN 50022) Cover Plastic UL94 V0 Operating position Vertical Operating temperature -40...+70ºC -10...+158ºF Degree of protection IP Class II IP 20 (double insulated) Certifications Compliant with VDE and UL on request 96

INSULATED RESISTANCE HEATERS Dimensions 1 Ventilation systems 38 1 2 75 2 Air-air exchangers L (mm) clip de fixation clip sur 35 rail mm DIN 35 DIN mmrail 98 3 Air-water exchangers 87501 98 87502 98 1 2 7 Calculation and selection aid software 6 Control devices 5 4 Cooling units 97

INSULATED RESISTANCE HEATERS 55 W - 100 W 147 W insulated resistance heaters General characteristics Compact resistance heater which prevents the formation of condensation and ice. Designed for a better natural convection and a high thermal performance. Extremely compact resistance heater. Extruded aluminium body. Features a plastic cover UL94 V0, light grey, to avoid direct contact with the aluminium radiator. Surface temperature limited to 70 C. Fitted with an insulated cable 2.5 mm 2. Double insulated. PTC technology range. Quick attachment by clips into 35 mm DIN rail (EN 50022). Certifications compliant with UL and VDE and EC Marking. Usage conditions The resistance heaters should be used with a hygrometer switch or a thermostat (thermostat 87561 or 87558, hygrostat 87560) to control temperature or humidity within the enclosure. The enclosure should be sealed to prevent the entry of external air. An electrical protection device should be installed on the supply side of the unit. Characteristics 87506 87518 87521 87509 87523 87528 87515 87536 87540 Power at 0ºC 55 W 102 W 147 W Voltage 110-250V 110-250V 270-420V 110-250V 12-36V 270-420V 110-250V 12-36V 270-420V Technology PTC Surface temperature <70 ºC, except for grill for higher protection Electrical connection Four-pole terminal for 2.5 m 2 Quick attachment By clips into 35 mm DIN rail (EN 50022) Cover Operating position Plastic UL94 VO Vertical Operating temperature -40...+70ºC -10...+158ºF Degree of protection IP Certifications Class II IP 20 (double insulated) Compliant with VDE and UL on request 98

INSULATED RESISTANCE HEATERS Dimensions 2 Air-air exchangers 1 Ventilation systems L (mm) 87506 110 3 Air-water exchangers 87509 110 87515 150 Performances diagram 4 Cooling units Heating power/external temperature Diagram Heating power (W) 87515 87509 87506 5 7 Calculation and selection aid software 6 Control devices External temperature ( C) 99

INSULATED RESISTANCE HEATERS WITH FAN 177 W General characteristics Compact resistance heater which prevents the formation of condensation and ice. Designed for a better natural convection and a high thermal performance. Extremely compact resistance heater. Extruded aluminium body. Features a plastic cover UL94 V0, light grey, to avoid direct contact with the aluminium radiator. Surface temperature limited to 70 C. Fitted with an insulated cable 2.5 mm 2. Double insulated. PTC technology range. Quick attachment by clips into 35 mm DIN rail (EN 50022). Certifications compliant with UL and VDE and EC Marking. Usage conditions The resistance heaters should be used with a hygrometer switch or a thermostat (thermostat 87561 or 87558, hygrostat 87560) to control temperature or humidity within the enclosure. The enclosure should be sealed to prevent the entry of external air. An electrical protection device should be installed on the supply side of the unit. Characteristics 87555 Power at 0ºC Voltage Technology Surface temperature 177 W AC 230 V; 50-60 Hz PTC 50 ºC max. in the enclosure, 100 ºC over grill for higher protection (for an external temperature of 20 ºC/68 ºF) Service life 40,000 h at 40 ºC Air flow 13.8 m 3 /h Electrical connection Two-pole terminal for 2.5 m 2 Quick attachment By clips into 35 mm DIN rail (EN 50022) Cover Operating position Plastic UL94 V0 Vertical Operating temperature -40...+70 ºC -10...+158 ºF Degree of protection IP Certifications Class II IP 20 (double insulated) Compliant with VDE and UL on request 100

INSULATED RESISTANCE HEATERS WITH FAN Dimensions 7 Calculation and selection aid software 6 Control devices 5 1 Ventilation systems 4 Cooling units 3 Air-water exchangers 2 Air-air exchangers 101