RIVERA P5000. Folding awning P5000

Similar documents
External venetian blinds

Pleated blinds, free hanging units FS, FK, FE Description

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

External venetian blinds

THE WIDTH AND HEIGHT OF THE LIGHT HOLE IN THE WINDOW WING IS MEASURED IN THE FOLLOWING WAY:

Shading Tension Systems

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

CONTENTS PRODUCTS AND INNOVATIONS OF THE HELLA GROUP. SINTESI 12 The innovative pergola. Pergolas 06 Overview. Design characteristics 18 HELLA 22

ClimaSys Resistance heaters Selection guide

Technical Manual Pergola STAR

ES 200. Sliding door operator

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

Hakki Pilke Raven spare parts manual

Silent Gliss. Venetian Blind Systems

External venetian blinds

CONTENTS PRODUCTS AND INNOVATIONS OF THE HELLA GROUP. Control 23. SINTESI ARCHI 12 Without columns. Pergolas from HELLA 04 Living outdoors

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

RICCAR VIBRANCE VIBC.2

MC-UL Vacuum Cleaner. Specifications are subject to change without notice for further improvement. Order Number MAC CE

Installation Instructions

GETTING STARTED OPTIONAL HARDWARE A

Online Ordering. Swale Blinds has established itself as one of the UK s leading trade only Window Blind suppliers and installers.

Pleated Blinds L. 48 mm

1.1 This section applies to air handling units for HVAC Systems.

PERGOLA SUNEAL THE MULTI-SEASON LIVING SPACE. Architects: Giusti/Versini Photography: Laurent Descloux

Fusion-FX, G-Force, Focus. Features Advantage Benefits

ClearAccent - Affordable recessed LED spot

Smoke and Fire Curtains

External Blinds - Aluflex

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Ledinaire Batten Simply great LED

HEDMAN The HEDMAN Company 189 Gordon St. Elk Grove Village, IL

Installation Instructions

Installation and Care Instructions

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

Wet and dry vacuum cleaners NT 48/1 (110V)

CoreLine Waterproof the clear choice for LED

CoreLine Recessed Spot the clear choice for LED

Cord-operated curtain rails. elegant ease

Safety vacuum cleaner with automatic filter cleaning system, 42 l, class L

MEDIVA LED. Normal care / Horizontal Bed head units. Dynamic Lighting

DIVISION FURNISHINGS. WINDOW TREATMENTS Page 63 of WINDOW TREATMENTS WINDOW BLINDS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Product Range. The UK s leading trade only Window Blind manufacturer

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

PLEASE READ PRODUCT GUIDE NOTE IN FULL BEFORE COMPLETING ORDER FORM, 1 BLIND PER ORDER FORM, STATE QUANTITY IN BOX PROVIDED BELOW

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data

Technical Manual Pergola Arch

Safety vacuum cleaner with automatic filter cleaning system, 30 l, class L

Please read operating instructions carefully before use and keep it for further reference.

INLET DAMPER WALL FAN UNIT

Running Magnet 2.0 Suspension Down High-tech LED lighting system for interior architecture

Roll Heated Flatwork Finisher

Photography: Wenzel SHOP AND OFFICE FITTINGS TECHNAL SYSTEM AND FURNITURE

Neon LED Rope Light Installation Instructions

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

Running Magnet 2.0 Suspension Up&Down High-tech LED lighting system for interior architecture

Roto. U.S. Patent(s) Pending CERTIFICATE

Fire protection unit

July Colour Temperature switch. 60mm

TECHNICAL INFORMATION T1500 Series Clothes Dryers

TECHNICAL INFORMATION T 15xx Dryers

NT 27/1 Me. All-purpose vacuum cleaner built for demanding cleaning applications, with stainless steel container. On-board accessory storage

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

made in germany The art of controlling light ARTec Alulux external Venetian blind technology Alulux zip textile screens

HRS Hand Rail System 1

WYND DC 54 CEILING FAN Installation Manual

HVAC Module Assembly Replacement. Tools Required. J A Halogen Leak Detector. Removal Procedure

MC-V Vacuum Cleaner. Specifications are subject to change without notice for further improvement.

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

NT 65/2 Tact² Tc. Tilting chassis with container lock. Suction tubes and floor nozzles can be stored in any direction in the accessory holders

Material Handling MACHINES & SYSTEMS

NT 27/1. Cartridge filter with float. Robust bumper

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Contents. Track Styles... Flat... Inclined... Curved... Vaulted...

Vertical Blinds. Step by Step Installation Instructions

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Installation and Care Instructions. Wood Blinds and Alternative Wood Blinds. LiteRise Touch System. Getting Started

Ersatzteilliste Spare parts list

Glacial. COB Inground

WF2613 Classic Corner Washfountain with 9" Deep Bowl

1.1. The unit shall be manufactured with quality, durability, and professionalism.

MARINE. High efficiency pumps you can rely on

WOLF VENTILATION SYSTEM PRICE LIST

LA9800 BASE (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) (S/P) DESCONTINUADO DESCONTINUADO DESCONTINUADO (S/P) (S/P) (S/P)

OPERATIONS MANUAL REV A

Line Smoke Detector LRMX

TUNNELS BOXES AND CONNECTORS

AF-810 and AF-820 Venetian blinds

Wet and dry vacuum cleaners NT 27/1

Table of Contents. Ceiling Bracket Installation

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

NT 35/1 Tact Te. Tact system (Tact Automatic Filter Cleaning System) Ideal connections. High-quality, robust equipment.

Installation Instructions

Special vacuum cleaners NT 55/1 Tact Bs

OWNERS INSTRUCTION MANUAL

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

Transcription:

RIVERA Beschreibung Description min. 200 cm max. 500 cm 8 25 Wall mounting 8 25 Top fixation min. 200 cm max. 700 cm Terrace roof system comprising an aluminium extruded structure and integrated fabric shading. The structure is designed for wall and ceiling mounting and comprises two lateral carriers (dimension 80 x 150 mm). The brace in the front comprises two support profiles (120 x 80 mm) and a transverse profile (117 x 150 mm). The transverse profile also acts as a gutter and drains the water via lateral gutters as standard. To guarantee optimum drainage of the water forwards over the PVC fabric can be guaranteed, an incline of 8 up to max. 25 must be respected. The shading consists of a fabric which folds up when retracted or tensioned when extended. The fabric is connected to cord profiles (36 x 70 mm), which vary in number depending on the projection. To prevent the ingress of water, a cord is attached to both sides of the fabric and a brush seal to the lateral guides. Wind resistance: The system satisfies wind resistance class 4 when extended (tensioned fabric) or to 150 km/h when retracted. (DIN 13561 compliant) Cover: Polyester fabric (630 g/m²) with polyvinyl chloride coating and high-grade surface texture making it suitable for continuous outside use. Material thickness 0.5 mm. Washable and watertight up to a water column of 3000 mm. Burning behaviour flame-resistant class B1 in accordance with DIN 4102-1. Drive: Electric drive with electronic end stop to tension. Power feed 230 V/50 Hz. IP protection class 44. The force is transmitted to the front rail on both sides via a Kevlar-reinforced toothed belt Option: Drainage: Optionally, water can be drained away via lateral gutters or through the supports. Top board: 3 bevelled plates are mounted on two square profiles (extruded aluminium dimension 50 x 120 mm). Maximum projection 972 mm. Integrated LED lighting: The carrier profile contains a groove for an integrated light, which is aligned at an angle of 45 to the inside of the system, where an LED strip light (LED light source warm white) can be integrated. It is covered by a plastic reflector profile. Variants with remote control and dimmer are possible. Glazing: The all-glass sliding system SV1020 can be used as front and side glazing. The fixed glazing system SV1051 is used as side glazing (e.g. as a wedge) in combination with SV1020. The max. front or side surface of 15 m 2 per side must not be exceeded. I.S.L.A. Concept: Via specific connection fittings, the supports can be mounted in the corners of the frame profiles on flooring system SB4700. METHOD OF DELIVERY Cloth, cord profile and front rail supplied separately. Guide rails pre-mounted in longitudinal carriers, cross beam/ supports supplied separately. Remaining single parts loose, without fasteners. 11.1

RIVERA Side position With 1 module 11.2

RIVERA Version with max. 10 modules Wall installation 11.3

RIVERA Roof mounting with wall bracket (flush) Roof mounting without wall bracket (offset) 11.4

RIVERA Wall installation ~60 40 110 Top installation 110 ~60 ~60 40 11.5

RIVERA P505/. Connecting piece (for P521) P521 Wall bracket 75.4 P530 Connecting piece (for P531) P521 Wall bracket (centre) 75.4 200 20 80 80 20 200 20 80 80 20 30 80 320 260 M12 80 80 160 160 80 30 80 65 55 11.6

RIVERA P809/5 Foot plate with lug P809/4 Headpiece W3 = Support with Drainage hole 11.7

RIVERA 2 modules coupled Side assembly of the gutter 11.8

RIVERA Fabric track with cover board 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 X = 599 641 683 725 767 809 851 893 935 977 1019 n = 3 4 5 6 7 8 9 10 11 12 13 Table valid at 8 inclination and wall mounting E X 150 (n x 42) ~240 ~83 321 171 ~95 F 150 11.9

RIVERA Lighting 126.5 203 126.5 150 82 80 94 110 138 80 94 LED strips SL115 - SL160 150 200 250 300 350 400 450 500 550 600 cm SL115 2 x 12W = 24W 12W 12W SL120 2 x 16W = 32W 16W 16W LED strips inclusive 600 cm Electrical cable SL125 2 x 20W = 40W 20W 20W EZ603-4 SL130 2 x 24W = 48W SL135 2 x 28W = 56W 24W 24W 28W 28W SL140 2 x 32W = 64W 32W 32W SL145 2 x 36W = 72W 36W 36W SL150 2 x 40W = 80W 40W 40W EZ603-5 SL155 2 x 44W = 88W SL160 2 x 48W = 96W 44W 44W 48W 48W 11.10

RIVERA Exploded view with 1 module P505/1 P511 TP710 TP720 P516 TP712 P515 P519 TP747 P501 P506-948 P506-728 P507-900 P507-1700 P517-900 P517-1700 P513 TP702 TP753 EZ602/.. P504 TP706 TP749 TP713 P512 TP714 TP727 P502 P521 P514 GP511/1 GP7 15/1 GP528 P503 P713 P809/4 P724/1 P505/2 GP511/2 P809/5 P850 P832 11.11

RIVERA Exploded view with 2-10 modules P531 P536 P530 P525 P542 P742 P715/1 P715-1 P528 P529 P728-1 11.12

RIVERA Components list P501 for TP702 Fabric holder P502 Fabric support profile 500 cm P503 Fabric support profile width 500 cm P504 Fabric support profile width 500 cm P505/1 P505/2 left right Connecting piece P506-728 P506-948 for P507-... for P517-... Cover lateral (Canopy) 74 cm 96 cm P507-900 P507-1700 Sheet roof (Canopy) 75.2 cm 75.2 cm P508 for P507-... Sheet roof coupling (for 2-3 adjacent modules) 75.2 cm P511 Beam 700 cm P512 for P502 End cover fitting P513 for P504 End cover fitting P514 for P503 End cover fitting P515 Protective roof fitting P516 Cover 700 cm P517-900 P517-1700 Sheet roof (Canopy) 97.2 cm 97.2 cm P518 for P517-... Sheet roof coupling (for 2-3 adjacent modules) 97.2 cm P519 Motor holder P521 for P505/. Wall bracket P525 Double carrier 700 cm P528 for P724/1 Gutter coupling with water drainage P529 for P724/1 Gutter coupling P530 centre Connecting piece P531 for P530 Center wall bracket P536 Center coverboard set P542 for P528 Drain sieve P703 for P713 Hose clip P713 for P715/1 Hose lm P715/1 for P724/1 Drainage P715-1 for P528 Stub tube P724/1 Gutter 400 cm 500 cm 600 cm 700 cm P728/1 for P724/1 Gutter coupling P742 for P529 Drain sieve P809/4 for P832 Headpiece P809/5 for P832 Foot plate with lug 11.13

RIVERA Components list P832 Post profile 700 cm P850 Corner reinforcement GP511/1 GP511/2 left right Gutter cover fittings GP511/4 GP511/5 left right Gutter cover with gutter fittings GP528 for P724/1 Drain sieve 200 cm GP533 for P724/1 Wall bracket TP702 Fabric support profile 500 cm TP706 Motor shaft 500 cm TP710 Guide profile 700 cm TP712 Drive fitting TP713 Pulley kit TP714 Holding bracket TP720 Toothed belt TP727 Inner cover TP747 Holder TP749 Motor holding bracket TP753 Beam (Canopy) EZ602/150 EZ602/200 EZ602/250 EZ602/300 Plastic cover 150 cm 200 cm 250 cm 300 cm EZ603-4 EZ603-5 LED converter 90 W 24 V 120 W 24 V MZ234 Junction box IP55 SL115 SL120 SL125 SL130 SL135 SL140 SL145 SL150 SL155 SL160 LED strips inclusive 600 cm Electrical cable 150 cm 200 cm 250 cm 300 cm 350 cm 400 cm 450 cm 500 cm 550 cm 600 cm 11.14

RIVERA P501 P505/2 P512 P502 P506-... P513 P503 P507-... P514 P504 P508 P515 P505/1 P511 P516 11.15

RIVERA P517-... P528 P542 P518 P529 P703 P519 P530 P713 P521 P531 P715/1 P525 P536 P715-1 11.16

RIVERA P724/1 P832 GP511/5 P728/1 P850 GP528 P742 GP511/1 GP533 P809/4 GP511/2 TP702 P809/5 GP511/4 TP706 11.17

RIVERA TP710 TP727 EZ603/. TP712 TP747 MZ234 TP713 TP749 SL115 - SL160 TP714 TP753 TP720 EZ602/... 11.18