Mercury Vapor Monitor VM-3000

Similar documents
VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor

stationary dose rate measuring systems

PG 990 Atomic Absorption

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Constant climate chambers

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Constant climate chamber with humidity

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Series 9000 Total Hydrocarbon Analyzer

Constant climate chambers

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Constant climate chambers

A New Standard of Excellence

PUV, PIR and PFO Series BROCHURE

CLEAN-LASERSYSTEME GMBH

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Constant climate chamber with ICH-compliant illumination

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

portable gas analyser

ALPHA+ Light Exposure and Weathering Testing Instrument. Xenotest Alpha+ Features. Xenotest Alpha+ Specifications. Sample Capacity

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

SP-3800AA Atomic Absorption Spectrophotometer

Customised HPLC Systems for Highest Performance

Specification for On-Line UPS Battery Monitoring and Data Management System

SEC Signature Process Gas Analyzer

Specifications Wavelength Range: 190 nm to 800 nm continuous

HSD Dry Cabinet

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

Gas detection for your safety

Variable Temperature Options for Optical Experiments

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Pressure measuring instruments

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Advanced FireAlarm Panel 1-4Loop

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

Standard Specifications

Dräger Polytron Pulsar 2 Open Path Gas Detector

Operate the Mutli-Gas Monitor PID

ELD500 PRECISION LEAK DETECTOR

incubator, the best in its class

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Parameterisable compact fault annunciator with permanent display

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Certificate: _01 / 22 March 2013

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Dräger PIR 7200 Toxic Gas Detection Transmitter

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Huminator II. Precision Humidity Generator. ww.testo.in

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

HSD Dry Cabinet. Outstanding performance

Model KBWF 720 Growth chambers with light and humidity

Chemistry Instrumental Analysis Lecture 4. Chem 4631

SAM-MAX Refrigerant Monitors

Model gffoz Process Ozone Sensor (In-Line)

Intelligent addressable fire alarm control panel

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Microtherm Heat Stress WBGT

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

WASTEWATER Online UV%Transmission Analyzer

Chlorine gas leak detector

DP 300 mobile dew point instrument

Series 5000 Hydrazine Analyzer Model 60002

AS950 REFRIGERATED SAMPLERS

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

portable gas analyser

Dräger Polytron 7000 Fixed gas detector

PHOENIXL 300 New Standards in Leak Testing. Technical information

Dräger Pac 6000 Single-Gas Detector

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Infrared Moisture Determination Balance FD-610. Operating Manual

Dew point set DS 400

BRS Mechanically-Agitated BioReactor MA 100. Quick Reference Guide Ver2.0

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Atomic Absorption Spectrometer

Data Sheet. >>AMTAX inter 2

DIESEL Engine Fire Pump Controllers Features

COMPLETELY AUTOMATED HYDROLYSIS

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

SIMRAD GD10PE IR GAS DETECTOR

SECTION Fluorescent Dissolved Oxygen Measuring System

Specifications Minimum Typical Maximum Unit

Transcription:

Member of the envea Group Mercury Vapor Monitor VM-3000 Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS) Measuring ranges 0-100 / 0-1000 / 0-2000 µg/m³ Easy operation Automatic zero adjustment Sensitivity: 0.1 µg/m³ Integrated battery for mobile operation (option) integrated Data logger (option)

Fields of application The VM-3000 Mercury Vapor Monitor serves for continous measurement of the mercury concentration in air and other gases in laboratory as well as industry and mobile applications. It has a wide variety of applications: work place monitoring (threshold limit value) exhaust air monitoring in mercury recovery plants emission monitoring in the chemical industry ground air screening of contaminated soil quality control of hydrogen and natural gas detector and analyzer for laboratory applications Measuring principle The mercury concentration is measured in an optical cell made of fused silica. A maintenance-free membrane pump continuously feeds the sample gas to the optical cell where UV absorption is measured at a wavelength of 53.7 nm. This so-called cold vapor atomic absorption spectroscopy (CVAAS) measuring method is extremely sensitive for mercury determination and has been used successfully for many years. In contrast to the occasionally propagated atomic fluorescence spectroscopy (AFS) method it is low in interference and requires neither an amalgamation step nor expensive noble gases as carriers. VM-3000 Flowchart Analytical Performance The VM-3000 uses a high-frequency driven electrodeless Hg low pressure lamp (EDL) as UV source. It generates emission lines of an extremely narrow bandwidth congruent with the the absorption lines of the Hg atoms. Cross-sensitivities are thus minimized. The extremely high stability of the UV source in the VM-3000 is a result of the reference beam feedback control method. Total background noise is less than 0.1 µg/m³. To prevent temperature drift both the lamp unit and the detectors are temperature stabilized. The optical cell heating makes it insensitve to water vapor.

Special Features Metal housing with sturdy handle Option: Rack version with mounting brackets for 19 racks Membrane pump with long service life Input filter with teflon membrane Factory-calibrated Stable optical bench Precise and proven technique: The Mercury Vapor Monitor VM-3000 The soul of the machine:the optical bench inside the VM-3000 Easy to operate The user controls the VM-3000 by menu-guided inputs via a waterproof membrane keypad. After switch-on the light source is stabilized (approx. 1-15 minutes). Before the measurement starts, a zero adjustment is automatically carried out. The analyzer then switches to measurement mode and continuously indicates the measured mercury concentration of the gas as a numerical value and a graphic bar. The following settings are possible in the parameters menu: duration and repeat interval of the zero adjustment selection of the concentration unit: µg/m³ or ppb measuring range (0.1-100, 0-1000, 0-2000 µg/m³) input of three different alarm levels calculation of a mean value over three freely selectable time intervals printer activation sample dilution factor (if required) Display and Output of Measurements The result of a measurement is displayed in real time and output as an analogue electrical signal of 4-20 ma. The device also features digital outputs for alarm, status and measurement values for full integration in plant control systems as well as a serial interface (RS 232 / USB) for data transfer to a PC or Laptop (Software Hg-Transfer included on delivery).

Extensions The VM-3000 Mercury Vapor Monitor is the basic model of our modular system for mercury analytics. An optional reaction unit and activation of the appropriate software turn it into a laboratory unit for liquid samples (Mercury LabAnalyzer-254). Multiplexer Operation The VM-3000 can be combined with a multiplexer unit for automatic monitoring at several different measurement points. See information about the Mercury Monitoring System (MMS) in a special brochure. Self Diagnosis System If an important component of the VM-3000 malfunctions the user is warned via the display (blinking messages) and via output signals e. g.: clean cell lamp low battery alarm Battery Operation for mobile Use For operation independent from mains power the VM-3000 is also available with a built-in rechargable battery and a charger unit. This option allows mobile battery-powered applications of up to approx. 4 hours. Data Logger Function A data logger function can be integrated into the VM-3000 as an option. Up to 30 000 readings can be stored in the data memory. The logging interval can be set from 1-999 seconds resulting in a total recording capacity of 8 hours to 346 days. The stored data can be read out with a PC using the serial interface of the analyzer (RS232 or USB). Data transfer software is incuded (Hg-Transfer).

Dustproof enclosure The VM-3000 with dustproof enclosure is now available in our regular product line. It is meant for stationary wall or stand mounting. All necessary cables and tubings are fed through the dustproof cable glands on the bottom of the enclosure. The VM-3000 unit has all of its electrical in- and outputs as well as the sample gas in- and outlet on the rear. They are easily accessible by simply swinging open the enclosure.

VM-3000 : Technical Specifications Measuring principle: Cold vapor UV absorption (CVAAS) Wavelength: 253.7 nm UV source: Electrodeless low-pressure mercury lamp Stabilization: Reference beam and thermal Optical cell: fused silica (Suprasil), 23 cm long, heated to avoid condensation 0... 100 µg / m³ Measuring range: 0... 1000 µg / m³ 0-2000 µg / m³ Sensitivity: 0.1 µg / m³ Response time: <1 sec Computation of mean values: autom. via three freely selectable time intervals Alarm: when concentration is exceeded, 3 levels programmable Measuring cell soiled Status alarm: battery state UV source Control pad: waterproof membrane keypad Measurement display: Graphic dipslay with background lighting 4... 20 ma Signal outputs: RS 232 USB, bidirectional Pump: membrane pump, approx. 2 L/min. Filter: PFTE, 1µ, 47-50 mm diameter Power supply: 110 V / 60 Hz 240 V / 50 Hz Battery operation: optional, 12 V rechargeable batteries integrated, 4h capacity Data logger function: up to 30 000 readings Power consumption: 40 VA Dimensions: 45 x 15 x 35 cm (W x H x D) Weight: approx. 7 kg Mercury Instruments GmbH Analytical Technologies Liebigstrasse 5 85757 Karlsfeld / Germany mail@mercury-instruments.de Tel.: +49(0)8131-50 57 20 Fax.: +49(0)8131-50 57 22 2018 Mercury Instruments GmbH, Mercury Vapor Monitor VM-3000 Specifications subjet to change without notice Distributed by: As a leading supplier of high precision analytical equipment, we strive at all times to offer top quality solutions. Our products are manufactured according to the ISO 9001 quality regulations. www.mercury-instruments.de