Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Similar documents
Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

Fiber Optic Distribution Cables (6-144 Fibers)

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

HELKAMA. Optical Fibre Cables

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

DNVGL-CP-0402 Edition February 2016

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

Ø 1000 * 588 mm 50 kg

industry solutions: military

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Duct Cable GYTS-144B1.3

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Fibre Specification Standards

SPECIAL ELECTRICAL AND OPTICAL CABLES

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

Compact Module. Category 6A FTP Cabling System 1.1

Fiber Optic Patch Cord and Pigtails

STANDARD CONFORMANCE

FIRE RESISTANT CABLES

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Fibre optic media options and trends

Traction Cable Radox 3 GKW

Fibre Optic Cable. Catalogue.

DNVGL-CP-0401 Edition February 2016

PRODUCT CATALOGUE Norröna

DNVGL-CP-0399 Edition March 2016

Special Provision No. 683S28 December 2017

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

High Performance LSZH Fire Resistant Cable

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

TYPE APPROVAL CERTIFICATE

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

MT-RJ Optical Fiber System Field Testing

infrastructure for 10, 40 and 100Gbits/s readiness

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Caledonian Flame Retardant Coaxial Cables

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Multi-Core Fire Resistant Cable

CATEGORY 6A FTP RJ45 SOLUTION

fire resistant cables

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Fire Safety Fire Resistant Building Components

OPTICAL FIBER SOLUTIONS

FiberExpress Solutions

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Photovoltaic Cables EN H1Z2Z2-K

ITU-T L.404. Field mountable single-mode optical fibre connectors

4120 Fire Alarm Network Reference

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Fibre (TIA) Field Test Specification

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Lloyd s Register Type Approval System Test Specification Number 3

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Qualification Test Report LC Duplex Adapter For LC Cutouts

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Fiber Optics for Todays Industry Applications

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

Caledonian Fire resistant Coaxial Cables

Single core cables with reduced wall thickness

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

LCS 2 YOUR digital infrastructure

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

INTERNATIONAL STANDARD

Basic Professional Fiber Optic Installation

Transcription:

Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors bend insensitive fiber cable jacket: LSHF-FR UV resistant, metal-free, longitudinally watertight cable structure: several separately strain relieved cables in one outer jacket strain relief: Aramid applicable standards: EN 50173-1, ISO 11801 2nd edition, IEC 60794-2, IEC 60794-2-10, EN 187000 fire behaviour: class Dca acc. to EN 50399 (Klassifizierung nach EN 13501-6) Variants: Number of OS2 fibers 4x1, 8x1, 12x1, 24x1 Number of OM5 fibers 4x1, 8x1, 12x1 Number of OM4 fibers 2x1, 4x1, 8x1, 12x1, 24x1 Number of OM3 fibers 4x1, 8x1, 12x1, 24x1

Page 2/9 General Data Fields of application Design Structured building cabling, Office Fiber to the Desk,, Data center breakout cable Transmission technology Fiber optic Color violett Mode type of the fiber Multimode Fiber class Cable Type OM4 (ISO/IEC 11801/EN 50173 & IEC 60793-2-10/EN 60793-2-10 A1.a.3) Breakout Number of cables/ cores 1 Number of fibres each cable/ wire 12 Fiber construction 50/125 µm Weight 160.00 kg/km Connections/interfaces Connector technology interface 1 Free line end Connector technology interface 2 Free line end Cable sheath diameter (min. - max.) Cable sheath diameter 12.50 mm Cable sheath diameter 0.492 in. Optical characteristics Attenuation of the fiber Attenuation of the fiber in the cable at 850 nm 3.0 db/km Attenuation of the fiber in the cable at 953 nm 2.3 db/km Attenuation of the fiber in the cable at 1300 nm 1.0 db/km Mechanical characteristics strain relief aramide fibres Permanent tensile strength 1150 N Short term tensile strength 2300 N Maximum installation load (max.) 3500 N Maximum installation load 150.00 mm Maximum installation load 5.906 in. Maximum operating bending radius 250.00 mm

Page 3/9 Mechanical characteristics Maximum operating bending radius 9.843 in. Impact resistance 20 J Crush (compressive strength) 1500 N Fire load 2500 MJ/km Materials and material properties Material - Cable jacket LSHF-FR Bend insensitivity Flame retardancy Halogen free Metallfrei UV-resistance Environmental conditions Temperature (min. - max.) Temperature - Storage C -40-70 C Temperature - Storage F -40-158 F Temperature - Operating C -20-70 C Temperature - Operating F -4-158 F Temperature - Installation C -20-70 C Temperature - Installation F -4-158 F Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC 11801 Ed.2 DIN EN 50173-1 Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ISO/IEC 60793-2-10 (A1a.3)

Page 4/9 The product meets the following standards Optical fibers: Indoor optical cables Family specification for multi-fibre optical cables ISO/IEC 60794-2-20 Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content IEC 60754-1 Determination of acidity (by measuring the ph value) IEC 60754-2 and conductivity Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated DIN EN 60332-1-2 wire or cable Test for vertical flame spread of vertically-mounted ISO/IEC 60332-3-24 bunched wires or cables Measurement of smoke density of cables burning ISO/IEC 61034-2 Common test methods for cables under fire conditions Fire behaviour - class ITU-T standard fire behaviour: Class Dca acc. to EN 50399 (classification acc. to EN 13501-6) G.651.1 Packing details Type of packaging meter

Page 5/9 Illustrations Principle diagram

Page 6/9 Fiber color coding Fiber color code 1 2 3 4 5 6 7 8 9 10 11 12 red green blue yellow white grey brown violet turquoise black orange pink

Page 7/9 OpDAT fiber OM4 BR 150XXX7 General Data Transmission technology Fiber optic Mode type of the fiber Multimode Fiber class OM4 (ISO/IEC 11801/EN 50173 & IEC 60793-2-10/EN 60793-2-10 A1.a.3) 50/125 µm Fiber construction Transmission characteristics Transmission rate up to 10 GBit (Gigabit-Ethernet) IEEE 802.3an Transmission rate up to 100 GBit IEEE 802.3ba Reach Reach 1000BASE SX 1100 m Reichweite 10GBASE SR 550 m Reach 40GBASE SR4 190 m Reichweite 100GBASE SR4 100 m Reichweite 100GBASE SR10 190 m Overfilled (OFL) modal bandwidth at 850 nm (min.) 3500 MHz * km Overfilled (OFL) modal bandwidth at 1300 nm (min.) 500 MHz * km Effective modal bandwidth (EMB) at 850 nm (min.) 4700 MHz * km Connections/interfaces Connector technology interface 1 Free line end Connector technology interface 2 Free line end Fiber core diameter 50 ± 2 µm Core-/ Fiber cladding diameter 125.0 ± 1.0 µm Primary coating diameter - colored 250 ± 15 µm Primary coating diameter - uncolored 242 ± 7 µm Optical characteristics Attenuation of the fiber Attenuation of the fiber in the cable at 850 nm Attenuation of the fiber in the cable at 1300 nm max. 2.5 db/km max. 0.7 db/km Maximum value of cable attenuation at 850 nm 3.0 db/km Maximum value of cable attenuation at 1300 nm 1.0 db/km

Page 8/9 OpDAT fiber OM4 BR 150XXX7 Mechanical characteristics Proof stress level min. 0.7 ( 1 %) GPa Typische durchschnittliche Abziehkraft min. 1.0 max. 3.0 N Strip force (peak) min. 1.3 max. 8.9 N Biegeverlust Dornradius = 7.5 mm, 2 Umdrehungen bei 850/1300 nm Dornradius = 15 mm, 2 Umdrehungen bei 850/1300 nm min. 0.2 - max 0.5 db min. 0.1 - max 0.3 db Fiber cladding non-circularity max. 0.7 % Core non-circularity max. 5 % Core (MDF)-cladding concentricity error max. 1 µm Primary coating concentricity error max. 5 % Primary coating-cladding concentricity error max. 10 Inhomogeneity of OTDR measurement report at 1310 nm und 1550 nm Group refractive index Gruppen-Brechungsindex bei 850 nm max. 0.1 db/km Gruppen-Brechungsindex bei 1300 nm Numerical aperture 1.482 1.477 0.200 ± 0.015 Materials and material properties Bend insensitivity Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements Data centers ISO/IEC 11801 cat. OM4 TIA/EIA 568-C ISO/IEC 24764 Optical fibers: Measuring methods and test procedures Fibre geometry ISO/IEC 60793-1-20 Coating geometry ISO/IEC 60793-1-21 Length measurement ISO/IEC 60793-1-22 Fibre proof test ISO/IEC 60793-1-30 Coating strippability ISO/IEC 60793-1-32 Attenuation ISO/IEC 60793-1-40

Page 9/9 OpDAT fiber OM4 BR 150XXX7 The product meets the following standards Powered by TCPDF (www.tcpdf.org) Optical fibers: Measuring methods and test procedures Bandbreite ISO/IEC 60793-1-41 Numerical aperture ISO/IEC 60793-1-43 Gruppenlaufzeitdifferenz ISO/IEC 60793-1-49 Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ISO/IEC 60793-2-10 (A1a.3) ITU-T standard G.651.1 TIA/ANSI-492 AAAD