Fat, Oil, and Grease (FOG) Program Frequently Asked Questions (FAQ)

Similar documents
I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

Program Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4

Keeping. Fats, Oils, and. Grease. Out of the Sewer

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors

Best Environmental Management Practices

F.O.G. 2/8/2013. Frequently Asked Questions. Defining Fats, Oils, & Grease (FOG)

Best Management Practices (BMPs)

BUILDING AND CODES DEPARTMENT 350 Pageant Lane Suite 309 Clarksville, TN 37040

Prohibitions on using

FATS, OIL AND GREASE (FOG) PROGRAM

Grease Control Device Maintenance Recordkeeping

Fats, Oil, & Grease (F.O.G.) Participant Data South San Luis Obispo County Sanitation District

Grease Interceptors and Oil Separators

Fats, Oils, & Grease (FOG)

Fat-Free Sewers. How to Prevent Fats, Oils, and Greases from Damaging Your Home and the Enviroment

COOKING GREASE ITS EFFECT ON OUR WATER INFRASTRUCTURE

Fats, Oils and Grease Program (FOG)

Engineering Fact Sheet

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

4. TECHNOLOGY AND DESIGN CRITERIA

TOWN OF BILLERICA DEPARTMENT OF PUBLIC WORKS WASTEWATER DIVISION BILLERICA HEALTH DEPARTMENT

CHAMBERS COUNTY FOOD ESTABLISHMENT PROCEDURES AND REQUIREMENTS PROCEDURES FOR OPENING A FOOD ESTABLISHMENT

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

Grease Interceptors. General For the purpose of this standard, the following terms shall have the meaning indicated in this section.

CHAPTER 10 TRAPS AND INTERCEPTORS

Fats, Oils & Grease (FOG)

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHAPTER 10 TRAPS AND INTERCEPTORS

Yakima Health District 1210 Ahtanum Ridge Drive Union Gap, Washington Phone (509) Fax (509)

Food Service Facilities

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

168 Spotnap Road Charlottesville, VA Tel (434) Fax (434)

MARINA SEWER MAINTENANCE DISTRICT

Fats, Oils, and Grease (FOG) Policy and Procedures City of Palm Bay, Florida May 2013

Joseph Florio, Commissioner of Pub. Works Tel

Sewer System Management Plan - Appendices Richmond Field Station APPENDIX D - RESOURCES. EH&S Fact Sheets

Sewer System Management Plan - Appendices UC Berkeley Collection System APPENDIX D - RESOURCES. EH&S Fact Sheets

GREASE REMOVAL DEVICE GUIDELINES FOR PLOT/PLUMBING PLAN DRAWINGS AND INSTALLATION REQUIREMENTS

GREASE SEPARATION DEVICE SIZING OPTIONS

ADAMS COUNTY HEALTH DEPARTMENT PLAN REVIEW APPLICATION FOR FOOD ESTABLISHMENTS This is not a Food Establishment application. Fees are non refundable

Who Needs BIG DIPPER?

HOW THE RIGHT GREASE INTERCEPTOR CAN HELP YOU SAVE SPACE IN A COMMERCIAL KITCHEN

Commercial food preparation and service

Decentralized Wastewater Collection, Treatment System and Disposal

Minimum Requirements for Food Establishments (per the Texas Food Establishment Rules (TFER) 25 TAC 228)

APPENDIX F: GREASE SEPARATION DEVICE SIZING OPTIONS

TOWNSHIP OF WEST WINDSOR 271 CLARKSVILLE ROAD, P.O. BOX 38 WEST WINDSOR, NJ (609) FAX (609)

CONSUMER HEALTH SERVICES PLAN REVIEW PACKET

Fat, oil and grease is known as FOG in the drainage industry.

VEHICLE SERVICE FACILITIES Best Management Practices

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X

TOWNSHIP OF WEST WINDSOR P.O. BOX 38; 271 CLARKSVILLE ROAD WEST WINDSOR, NJ (609) FAX (609)

Innovative, Compact Design

Murfreesboro Water Resources Department FOG Management Policy

General Licensing Information. Checklist

Temporary Food Service Requirement Checklist and Application

Food Establishment Guidelines. Food Service Plan Review

TEMPORARY FOOD SERVICE ESTABLISHMENT REQUIREMENTS

Phone (573) Fax (573) Temporary Food Stand

Design of Precast Concrete Grease Interceptors

Mobile Food Services & Establishments

FOOD ESTABLISHMENT CONSTRUCTION GUIDE Revised December 19, 2011 Reviewed January 10, 2014

WBUD Customer s Manual

FATS, OIL & GREASE (FOG) POLICIES

Read Only Document Not For Distribution

Guide to Starting a Food Business

Dietary Department, Infection Control

FOOD SERVICE PLAN REVIEW WORK SHEET

Structural Guidelines. Food Service Establishments. Retail Food Stores

FARMERS MARKET INFORMATION

STEUBEN COUNTY HEALTH DEPARTMENT RETAIL FOOD ESTABLISHMENT PLAN REVIEW QUESTIONNAIRE

TENNESSEE OIL AND GREASE CONTROL GUIDANCE DOCUMENT

Food Service Plan Review Information

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

NZTIWF TECHNICAL GROUP

Town of Sturbridge Grinder Pump Policy Homeowner s Guide to Grinder Pumps

COMMUNITY EVENT FOOD VENDOR REQUIREMENTS. CONSTRUCTION SECTION: These are items that deal with the construction or setup of the food booth.

SludgeHammer. Owner s Manual. Model S-400/600. The latest advance in wastewater treatment. NSF/ANSI Standard #40. nature called. we answered.

HARNETT COUNTY PLAN REVIEW APPLICATION COVER LETTER FOOD SERVICE ESTABLISHMENTS

New Food Service Plan Review Checklist

THE CITY OF CHANDLER BOARD OF ADJUSTMENT WILL MEET FOR A SCHEDULED MEETING MONDAY, APRIL 14, 2014 IN THE CITY HALL OF CHANDLER, TEXAS AT 6:00PM

All food service facilities must be equipped with the following items for the pre-opening inspection:

FOOD SERVICE PLAN REVIEW WORK SHEET

SPECIAL EVENTS. Food Vendor Requirements

Alabama Department of Public Health. Retail Food Sales

GARCIA GALUSKA DESOUSA Consulting Engineers

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

Plan reviews are required for child care facilities that engage in diaper changing, meal preparation, and/or obtain drinking water from a well.

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

Cleaning and Sanitation Procedures Module Cafe/Dining Restroom

Trade Waste in the Food Industry

MINIMUM CONSTRUCTION AND EQUIPMENT REQUIREMENTS FOR FOOD AND BEVERAGE ESTABLISHMENTS

FOOD ESTABLISHMENT LICENSE APPLICATION Fee Required with Submission of Application

Read Only Document Not For Distribution

A. Pollution Prevention

ROTISSERIE OVEN PROGRAM GUIDE

Mailing Address: City: State: Zip: CONTACT PERSON FOR PLAN STATUS NOTIFICATION: Contact Person: Contact Phone: ( )

FROM: FORSYTH COUNTY DIVISION OF ENVIRONMENTAL HEALTH

Food Establishment Plan Review Application. Milton Health Department

Transcription:

Fat, Oil, and Grease (FOG) Program Frequently Asked Questions (FAQ) Q. Who is San Jacinto River Authority (SJRA)? A. San Jacinto River Authority (SJRA) is one of 10 major river authorities in Texas created in 1937 by the Texas Legislature. SJRA has four operating divisions: Woodlands, Lake Conroe, Groundwater Reduction Plan (GRP), and Highlands. The Woodlands Division provides wholesale water supply and wastewater treatment services to the municipal utility districts (Customer Districts) located in The Woodlands, Texas. Q. What is FOG and where does it come from? A. FOG comes from many sources and typically enters the sewer system through kitchen sinks and dishwashers. Grease is a byproduct of cooking and is found in a variety of things such as: meat, lard, cooking oil, shortening, butter & margarine, food scraps, baking goods, sauces, dairy products, etc. These products are washed down the drain and into sewer pipes. Q. What can be done to help reduce FOG problems in the sewer pipes? A. The only way to keep FOG out of the sewer pipes and prevent overflows is to keep the material out of the sewer in the first place. There are several ways to accomplish this: Don t pour grease down sink drains. Pour used grease into sealable containers and dispose of the containers accordingly. Scrape grease and food waste into the trashcan for disposal. Limit use of in-sink garbage disposals. These allow the grease laden food scraps to move further into the sewer system where they still can cause problems. Dry wipe greasy cookware prior to cleaning. Clean and maintain commercial grease traps/interceptors frequently. Talk to your friends and neighbors about FOG and encourage them to help keep it out of the sewer system. Q. Why do food service establishments need grease trap/interceptor? A. Grease traps and interceptors allow grease to separate and collect in a chamber and the water to

flow past grease trap/interceptor. Grease trap/interceptor equipment is standardized by the Local Plumbing Code (City of Houston Plumbing Code), Uniform Plumbing Code (UPC) or other approved and appropriate Plumbing Codes for commercial food handling businesses, and is required by SJRA. Q. What is the difference between a grease trap and a grease interceptor? A. Both devices do the same thing, separating and retaining free floating oils and greases. Small, in-floor or under-sink prefabricated units are most often referred as grease traps. Grease interceptors are the larger units located outdoors that offer much longer hydraulic retention times. The term Interceptor and Trap may be used interchangeably and can be referred as grease trap/ interceptor. Q. How do I know what size grease traps or interceptor is right for my business? A. New Facilities: Food service facilities which are newly proposed or constructed, or existing facilities which will be expanded or renovated to include a food service facility, where such facility did not previously exist, shall be required to design, install, operate and maintain a grease trap/interceptor in accordance with the SJRA Grease Trap Sizing Criteria, Local Plumbing Code (City of Houston Plumbing Code), UPC or other approved and appropriate Plumbing Codes. Existing Facilities: Existing grease traps/interceptors must be operated and maintained in accordance with the manufacturer s recommendations and in accordance with the SJRA Grease Order. Q. Can I get a waiver of the requirement to install an interceptor/trap? A. No. When baking and/or other similar cooking processes are used during food preparation at food service establishments that do not generate significant amount of FOG as to cause interference with the SJRA collection and treatment system, a small under-sink or in-floor grease trap can be used instead of a full-size exterior in-ground grease interceptor. Q. What happens if I remodel or sell my business? A. If you sell or remodel your business a reassessment of the grease removal equipment will be conducted under SJRA s Grease Program. Remodels requiring a building permit are required to

reassess the sizing matrix of the existing interceptor following SJRA s Grease Trap Sizing Criteria, Local Plumbing Code (City of Houston Plumbing Code), UPC or other approved and appropriate Plumbing Codes. Q. Which kitchen fixtures should I connect to the interceptor and trap and are there any that should not be connected? A. All grease bearing waste streams should be routed through an appropriate grease trap/interceptor, including: three-compartment sinks, pot/pan sinks, soup kettles, hand-washing sinks, dishwashers, mop sinks and floor drains. Drains that receive clear waste only, such as from ice machines, condensate from coils and drink stations, may be plumbed to the sanitary system without passing through the grease interceptor. No toilet/bathroom wastes are allowed to be connected through the grease interceptor. Q. How do I properly clean a grease trap? A. For small under-sink or in-floor traps: 1. Bail out any water in the trap to facilitate cleaning. 2. Dip the accumulated grease out of the trap and deposit in a leak proof, sealable, and water-tight container. 3. Remove baffles if possible. 4. Scrape the sides, the lid, and the baffles with a putty knife to remove as much of the grease as possible, and deposit the grease into a watertight container. 5. Remove solids from the bottom with a strainer or similar device. 6. Replace the baffle and the lid. 7. Record the volume of grease removed. 8. Contact a waste hauler or recycler for grease pick-up. For large exterior in-ground interceptor: You will need to hire a TCEQ licensed grease hauler. WARNING! Do not flush with hot water or use drain cleaners, acids, caustics, solvents, enzymes, bacteria, or emulsifying agents when cleaning grease traps and interceptors. These actions do not remove grease. They only allow it to pass deeper into the sewer pipes where it becomes more costly and difficult to remove.

Q. How often does the grease trap need to be cleaned? A. For most under-sink grease traps, weekly cleaning is needed. Larger in-ground grease interceptors are required to be cleaned (pumped) a minimum of every ninety (90) days unless otherwise approved by SJRA. However, the actual pumping frequency of an interceptor will vary based on the type of establishment it serves. Any person who owns or operates a trap, interceptor, or separator may submit, to SJRA, a request in writing for a variance to the ninety (90) day pumping frequency of their trap/interceptor, or separator. Q. What other businesses have to install wastewater pretreatment? A. Car wash and automobile repair businesses are required to have a Sand/Oil/Water separator. Photographic developers, doctor s offices, and dental offices are required to have a silver recovery system and amalgam separator. Dry cleaners are required to have a solvent recovery system. Washateria facilities are required to have a lint trap. Hair traps are required for beauty salons, barber shops, pet grooming facilities, hospitals or wherever hair clogging is a potential problem. Q. Can I clean my own grease trap? A. Food Services establishment users may clean their own trap provided they receive written approval from SJRA annually, and the trap is no more than fifty (50) gallons in liquid/operating capacity. Q. Do I need to use SJRA registered waste hauler to clean my grease interceptor? A. Yes, all waste haulers must be licensed with the TCEQ. Q. Do I need to send grease trap/interceptor cleaning waste manifest to SJRA? A. Yes, a copy of each manifest returned to the waste generator (FSE) shall be sent to SJRA by the waste generator via fax, email, or mail. Q. How long am I required to retain Waste Manifests? A. Copies of waste manifest returned to the waste generator shall be retained for five (5) years and be readily available for review by SJRA or other local authorities.

Q. Does a Food Services Establishment need to establish a training system? A. Yes. Users required maintaining traps, interceptors, or separators, shall establish a system of training designed to provide employees with appropriate instruction on the proper use and maintenance of such facilities. Training sessions shall be conducted annually to ensure that employees understand the essential elements of the system. New employees shall be trained immediately upon employment. All training must be documented. Q. What is strong waste? A. Strong waste is a term generally applied to the relative strength of a commercial or industrial liquid waste that is discharged into the sewer system. If the discharge exceeds 200 mg/l BOD or 220 mg/l TSS it is considered to be a strong waste. Q. How can I reduce my surcharge? A. The surcharge is based on multiple components; flow, BOD concentration and TSS concentration. Reduce any or all of these components and your surcharge will be reduced. Conserving water is a quick and simple way to reduce your surcharge. In addition, the strength of wastewater (BOD and TSS concentrations) can be reduced in many ways. The easiest way is to examine your housekeeping practices and take note of what is put down the drain. BOD and TSS surcharges may be reduced by minimizing discharges of the following: Milk and dairy products Dough products Sugar Alcohol FOG Cleaning chemicals Disposal of these types of materials into trashcans and garbage dumpsters will help reduce your surcharge and help SJRA maintain the sewer system. In addition, use or overuse of in-sink garbage disposals and poor maintenance of grease traps/interceptors can result in a high surcharge.

Q. What if I fail to clean my grease trap? A. A user shall have any trap, interceptor, or separator cleaned when ordered to do so by SJRA. Failure to have the unit cleaned by the deadline specified by SJRA shall cause for enforcement action and SJRA may precipitate the cleaning and bill the user for such costs, plus any additional costs incurred by SJRA. Q. Who will bear the costs for sampling and laboratory analysis? A. Where SJRA must perform sampling for investigative purposes, and finds a user negligent in complying with the Grease Order, the costs of such sampling shall be borne by the user.