Please send to the customer who is used this operation manual without fail. Operation manual Basis operation edition

Similar documents
Hot-air generator. Operation manual (Basis operation) TAKETSUNA MANUFACTORY CO., LTD. Please read this without fail before use.

Hot-air generator. Final edition of Electric hot-air generator!! Catalog No. 4 TAKETSUNA MANUFACTORY CO., LTD. Hot-air generator.

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

High pressure hot-air generator KD-series

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Motion Sensor Oscillating Heater with Digital Control

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

Model:DKG610(V)/650(V) Model:DKG810(V)/850(V)

INSTRUCTIONS FOR THD-U SERIES HOT AIR MATERIAL DRYERS

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

E11 Indoor Board Failed to Receive Signal from Signal Output Board III - 65 E12 Automatic Address Setting is in Progress: Automatic Address Setting

An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.

Advanced Ultraviolet Burner Controller

DESIGN & TECHNICAL MANUAL

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

Mobile Type Air Conditioner

TLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

MANUAL INTELLIVENT CELSIUS

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

Customized Industrial Products

DESIGN & TECHNICAL MANUAL

Emerson Blue Easy Set 1H/1C

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

DESIGN & TECHNICAL MANUAL

CAUTION. Installation Manual

DESIGN & TECHNICAL MANUAL

Programmable Towel Radiator Manual

INSTALLATION / OPERATING INSTRUCTIONS

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Simple Self-Diagnosis by Malfunction Code

TC515 and TC600 Installation Manual. a Winters company

RE-PR3-E-27 3-Phase Panel Mount 27kW

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

DIGITAL LIGHT CONTROLLER

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

GCS-300 No.GCS31E

INSTRUCTION MANUAL RM AM/FM Digital Alarm Clock Radio

Buttons on remote controller

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

OPERATING INSTRUCTION MAGNETIC POLISHING MACHINE TYPE PM-200

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

SAS803WHL-7 Thermostat for floor heating

SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT. DocID: 00G00089E

Small VRF system. for light commercial and home use SERVICE MANUAL

Owner's Manual TABLE OF CONTENTS

TC-150 CONVEYORIZED OVEN. OPERATION AND MAINTAINANCE MANUAL Ovens with Omron PLC and Touchscreen

Remote flower watering and monitoring, part II (automatic garden watering)

SR-5/2D Solar-Power-Regulator

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

DIGITAL ALARM UNIT Model ALU-AP

Room thermostats with LCD for wall mounting

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

TRUE INDUCTION DOUBLE BURNER TI-2C PORTABLE INDUCTION COOKTOP MANUAL

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

H&H Asia Group Limited

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Operator: Save these instructions for future use!

OPERATIONS MAINTENANCE MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

NH DV NH DV

OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-B10, 13, 16, 22N3KV2-E1. Outdoor unit RAS-10, 13N3AV2-E1 RAS-16, 22N3AV2-E ENGLISH

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Stratomaster Smart Single

Wired Controller XK60

Install Guide CT100. Caution. Caution

7. ON/OFF Controller (CZ-ANC2)

OWNER S MANUAL ENGLISH REMOTE CONTROLLER R05 YDS-R

Operating Functions Temperature Parameters

Part 3 Troubleshooting

INSTALLATION & OPERATION MANUAL

Programmable Outlet Thermostat. User Manual. Version 1.5s. Inkbird Tech. Co., Ltd.

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

- Data Brochure Boiler Control 274

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Transcription:

Please send to the customer who is used this operation manual without fail. Preservation type Hot-air generator C-type series Operation manual Basis operation edition Please read without fail before use. Thank you very much for purchasing Hot-air generator this time. Please confirm the model, type, and voltage by the name plate of this machine. The basis operation method of the hot-air generator is entered to this operation manual. Please see the operation manual total edition about Installation, Piping, Power supply, Service terminal, Abnormal detection. TSK Hot-air generator TSK-18 TSK-, TSK-4, 5 TSK-5HT TSK-56 TSK-6, 7 TSK-8 TSK-9, 10 TSK-1, 1 1. Usually operation. Timer operation, Timer stop. When External sensor is used 4. When External run is used 5. When Temp. alarm is used 6. When External control is used 7. When Cooling operation is used 8. Operation stop Contents of this operation manual are changed without notice. The figure and display in the operation manual does not guarantee actual specification. We prohibit that changes this operation manual without taking our permission. Kansai Electric Heat Corp.

1.Usually operation 1 Please turn on the factory (primary side) power supply. Stop lamp is lighted, "nfb" is flickered to HOT-AIR TEMP., and "off" is flickered to SETTING TEMP. Please turn on the breaker (NFB) of this Present temp. is displayed to HOT-AIR TEMP. "0" is displayed to SETTING TEMP., and "60"(Frequency) is displayed to AIR VOL. CNTL. (The fist time) Operation is not produced in this condition. TSK-18 becomes the display of by turning on the factory power supply. BLOW lamp (Green) is lighted and blow operation is started by pushing BLOW switch. nd thereafter, the setting value of the previous time is displayed to SETTING TEMP. and AIR VOL. CNTL. Air volume control settomg (Frequency setting) Air volume can be changed to 0-60Hz by the 1Hz by the up down key. Temp. does not rise to the max. temp. if the hot-air generator is non-load in the case of that the air volume is set up to 0Hz of the min. air volume setting value. (Because the minimum of the motor rotation number is set up in consideration of the cooling effect of blower motor.) Please squeeze the air volume in min. air volume setting condition by establishing the dumper to the inlet. 4 HOT-AIR lamp (Orange) is lighted and hot-air operation is started by pushing HOT-AIR switch. Hot-air temp. setting Hot-air temp. Air volume can be changed to 0-50 C by the 1 C by the up down key. Max. setting temp. of TSK-5HT is 500 C. Attention Hot-air temp. is measured and managed at the outlet temp. sensor position near the heater. But, difference in temp. may occur at the outlet face by the air turbulence of the physical by the increase and decrease of the passage air volume and the pressure loss of the outlet side and inlet side. We recommend to operation the hot-air generator with the temp. inside the oven by using the external sensor to measure more exact temp. HEATER lamp (Green) displays the ON/OFF condition of the heater by the lighting and flickering. -1-

. Timer operation, Timer stop Please set up hot-air temp. and air volume optionally control before timer operation or timer stop. Please set up the timer setting in stop condition. (Timer setting can not be set up during hot-air operation and blow operation.) Timer operation 1 Please push OPERATION BY TIMER switch. OPERATION BY TIMER lamp (Green) is lighted, and "00.00." is flickered to TIMER or the setting time of the previous time is lighted. Please set up optional time by the up down key. Time can be set up until 99 hours 59 minutes by 1 minute unit. After setting, the display changes from the flickering to illumination seconds later by separating the hand from the up down key. And, the setting value is registered. Please push HOT-AIR switch. Time counting (Reduction of the setting time) is started (Flickering of the dot display), and hot-air operation is started when the time counting becomes to "00.00.". And, HOT- AIR lamp (Orange) is flickered during time counting, and the lamp changes to lighting after hot-air operation was started. Display of the timer becomes to "00.00." after time counting ended. Timer operation and timer counting are stopped by pushing STOP switch. Timer stop 1 Please push STOP BY TIMER switch. STOP BY TIMER lamp (Green) is lighted, and "00.00." is flickered to TIMER or the setting time of the previous time is lighted. Please set up optional time by the up down key. Time can be set up until 99 hours 59 minutes by 1 minute unit. After setting, the display changes from the flickering to illumination seconds later by separating the hand from the up down key. And, the setting value is registered. Please push HOT-AIR switch. -- Time counting (Reduction of the setting time) is started (Flickering of the dot display), and hot-air operation is started. Hot-air operation is stopped when the time counting becomes to "00.00.". And, HOT-AIR lamp (Orange) is lighted during hot-air operation, and the lamp changes to flickering after hotair operation was started. Display of the timer becomes to "00.00." after time counting ended. Timer operation and timer counting are stopped by pushing STOP switch.

. When External sensor is used The temp. of the place that parted is controlled by the external sensor. Please set up after the external sensor is connected to the external sensor input terminal of the service terminal. Hot-air temp. setting of SETTING TEMP. value is the setting of the external sensor position, and hot-air temp. of HOT-AIR TEMP. value is the temp. of the external sensor position in the case that the external sensor is used. 1 Please connect the external sensor to the external sensor input terminal of the service terminal without that mistakes plus and minus. TSK-18-56 : External sensor input terminal TSK-6-1, External sensor input terminal E.S+ and E.S- 5HT : A6 (+) and A7(-) Please continue to push MODE switch (About seconds). "A1" is displayed to HOT-AIR, and "0" is displayed to SETTING TEMP. Please push MODE switch times once again. "ESn" is displayed to HOT-AIR, and "off" is displayed to SETTING TEMP. 4 Please change SETTING TEMP. to "on". Please return to the display of usually operation condition by pushing MODE switch 1 time after setting. 5 Please start hot-air operation after setting the optional temp. and air volume. EXT. SENSOR lamp (Orange) is lighted when external sensor setting is changed to "on". Barn out operates and operation is not started if the external sensor is set up in condition the external sensor is not connected (Refer to P14 of Operation manual Total adition). Please return SETTING TEMP. to "off" when the use of the external sensor is stopped. Attention Hot-air temp. is measured and managed at the outlet temp. sensor position near the heater. But, difference in temp. may occur at the outlet face by the air turbulence of the physical by the increase and decrease of the passage air volume and the pressure loss of the outlet side and inlet side. We recommend to operation the hot-air generator with the temp. inside the oven by using the external sensor to measure more exact temp. --

4. When External run is used Operation, stop, and heater ON/OFF of the hot-air generator can be operated by the signal from the 1 Please connect the outside signal (Unvoltage contact signal) to the external run ON/OFF terminal and external heater ON/OFF terminal of the service terminal. TSK-18-56 : TSK-6-1, 5HT : External run ON/OFF terminal E.R and COM External run ON/OFF terminal A1 and A External heater ON/OFF terminal E.H and COM Terminal voltage is less than DC1V.6mA External heater ON/OFF terminal A and A Terminal voltage is less than DC1V 7mA Please continue to push EXT. RUIN switch in stoppage condition after setting optional temp. and air volume (About seconds). EXT. RUN lamp (Orange) is lighted. Please operate by the outside signal. BLOW lamp (Green) is lighted at the time of blow operation by the external run ON/OFF signal is ON, external heater ON/OFF signal is OFF. HOT-AIR lamp (Orange) is lighted at the time of hot-air operation by the external run ON/OFF signal is ON, external heater ON/OFF signal is ON. Hot-air generator can not be restarted for about 0 seconds after this machine was stopped by the external run. (BLOW or HOT-AIR lamp is flickered at the time of the waiting condition of restarting, and this machine is started 0 seconds later from stoppage.) And, please the external control function when highly frequent heater ON/OFF is necessary because life of the inside relay becomes short if the external heater ON/OFF is turned ON/OFF frequently. BLOW switch and HOT-AIR switch are ineffective at the time of EXT. RUN mode (These can not operate). External run is reset by pushing STOP switch. And, OPERATION and STOP BY TIMER can not be operated by the external run. EXT. RUN mode is canceled by NFB of this machine is turned OFF. But, this is not canceled by the primary power supply is turned OFF. -4-

5. When Temp. alarm is used Alarm signal can be output when discharge hot-air temp. exceeded the optional regular range to setting temp. Please use as occasion demands. (This is ineffective at the time of shipment.) 1 Please continue to push MODE switch (About seconds). "A1" is displayed to HOT-AIR TEMP., 0" is displayed to SETTING TEMP. Please set up the optional temp. range by the up down key. Please return to the display of usually operation condition by pushing MODE switch times after setting. Please start hot-air operation. Alarm is output from the service terminal and TEMP.ALM lamp (Red) is lighted when hot-air temp. becomes more than +10 C or less than -10 C if "10" were set up. (Excerpt for temp. rising at the time of the hot-air operation start.) This machine is not stopped by the temp. alarm. Temp. alarm output is ineffective if setting of temp. alarm is "0". Temp. alarm is output as the unvoltage contact signal (Contact capacity AC50V 1A DC0V 1A) from temp. alarm output terminal. TSK-18-56 : Temp. alarm output terminal T.A and COM TSK-6-1, 5HT : Temp. alarm output terminal B5 and B7-5-

6. When External control is used Hot-air generator is controlled by the signal of the temp. controller that was established in the outside. At this time, temp. controller of this machine can be used as the discharge temp. upper limiter. Hot-air temp. setting of SETTING TEMP. and hot-air temp. display of HOT-AIR TEMP. is the temp. of the outlet sensor in the case that the external control function was used. 1 Please prepare the temp. sensor that measures the temp. of the outside and the temp. controller that control the temp. of the outside. Please connect the output of the outside temp. controller to the external control input terminal of the service terminal without that mistakes plus and minus. (There is polarity.) TSK-18-56 : External control input terminal TSK-6-1, External control input terminal E.C+ and E.C- 5HT : A4 (+) and A5(-) SSR drive reverse action output (DC1V - 4V) SSR drive reverse action output (DC1V - 4V) TSK-1, 1 : External control input terminal A4 (+) and A5(-) DC4-0mA Output (4mA : Heater output 0%, 0mA : Heater output 100%) Please continue to push MODE switch (About seconds). "A1" is displayed to HOT-AIR, and "0" is displayed to SETTING TEMP. Please push MODE switch 1 time once again. "SSc" is displayed to HOT-AIR, and "off" is displayed to SETTING TEMP. 4 Please change SETTING TEMP. to "on". Please return to the display of usually operation condition by pushing MODE switch times after setting. 5 Please start hot-air operation after setting the optional temp. and air volume, and please start even temp. control by the temp. controller of the outside simultaneously. EXT. CNTL lamp (Orange) is lighted when external control setting is changed to "on". Hot-air generator is controlled by temp. that reached any early of temp. that was set up with the temp. controller of the outside or discharge setting temp. of the hot-air generator. So, please set up each temp. in consideration of the radiation of piping etc. Please return SETTING TEMP. to "off" when the use of the external control function is stopped. -6-

7. When Colling operation is used Only in the case that timer operation is selected, cooling operation function can be used. Blow operation in optional time is conducted after the hot-air operation by the timer is conducted, and operation is stopped. Cooling operation for heater snapping of a wire prevention is not necessary because the hot-air generator of the our company is set up the watt density of the heater low. So, please use for the burn prevention of the piping etc. by the remainder heat after operation stoppage and for cooling after the work of the drying heating product. 1 Please continue to push TIMER UP key while Please change SETTING TEMP. to "on" by up pushing MODE switch in stoppage condition. key, and push MODE switch 1 time. "T-" is displayed to HOT-AIR TEMP., and "off" is displayed to SETTING TEMP. "00.00." is flickered to TIMER. Please set up optional cooling time by the up down key. Please return to the display of usually operation condition by pushing MODE switch 1 time after setting. 4 Please set up the hot-air operation time by pushing STOP BY TIMER. 5 Please push HOT-AIR switch. Time counting is started (Flickering of the dot display), and hot-air operation is started. And, HOT-AIR lamp (Orange) is lighted during hot-air operation. Cooling operation (Blow operation) is started by the timer after hot-air operation is stopped by the timer operation. And, BLOW lamp (Green) is lighted during cooling operation. Cooling operation (Blow operation) is stopped when the time counting becomes to "00.00.", and BLOW lamp (Green) is flickered. Timer operation is stopped by pushing STOP switch. (Timer setting is returned to the initial setting value.) -7-

8. Operation stop Please push STOP switch in the case that the hot-air generator is stopped at the time of usually operation. Please turn off even the factory power supply side in the case that the hot-air generator is not used the long time. 1 Please push STOP switch. STOP lamp (Green) is lighted, and all operation is stopped. Please turn off even the factory power supply side in the case that the hot-air generator is not used the long time. All display is not lighted. Breaker of this machine (NFB) does not need to turn off. Please turn off the factory side power supply or the breaker of this machine (NFB) after the hot-air generator is stopped by STOP switch without fail. Hot-air generator may malfunction if the hot-air generator is stopped by the factory side power supply or the breaker of this machine during operation. External run mode is canceled if the breaker of this machine is turned off and is turned on again when the hot-air generator is operated or stopped by the outside run function. Please block by the factory side power supply (Primary power supply) without fail in the case that the power supply is blocked when this machine is operated by the external run mode. (External run mode is held by the input of the factory side power supply.) Please do not operate and stop the hot-air generator by the electromagnet contact device etc. that was established to the primary side of the hot-air generator. The inside electron devices damage by serge voltage. Please turn on the breaker (NFB) of the hot-air generator constantly. Please do not do on/off as the operation switch. The inside electron devices damage by serge voltage. About the instantaneous stoppage action at the time of the power failure In all the machine types except for TSK-18, the hot-air generator is returned automatically to the operation condition before the block if the input (return) of the power supply is within one second case of instantaneous block of the factory side power supply by power failure etc. Hot-air generator is stopped and may become to the condition that blower warning occurred when the power supply was input (return) in the case that power supply block time is for more than one second. In this case, please turn off the breaker of this machine at first and turn on once again. And, the operation is started once again. (At this time, the external run mode is canceled.) -8-