Excel FWGH Merchandiser Data Sheet P/N 0540996_F NSF Certified January 2018 Note: Portion of parts removed for clarity. NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. Performance Data Page 2 Product Data (AHRI Statistics) Page 2 Cross Section Page 3 Plan Views Page 4 Estimated Shipping Weights Page 5 Loads Page 6 Replacement Parts List Page 7 Wiring Diagrams Page 8 Computing Refrigeration and Load Page 10 Revision History Page 10 Data sheet-excel FWGH We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. 2018 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0542264
Refrigeration Data 1 8 Ft Case AHRI 1200 MED FF IC Rating Point 2 Discharge Air F ( C) 24 ( 4.44) 12 ( 24.44) 22 ( 30.00) 15 ( 26.11) Evaporator F ( C) 19 ( 7.22) 20 ( 28.88) 30 ( 34.44) 24 ( 31.11) Unit Sizing F ( C) 17 ( 8.33) 23 ( 30.55) 33 ( 36.11) 27 ( 32.77) Btu/hr per ft (Watts/m) Parallel 500 (481) 675 (649) 755 (726) 700 (673) Conventional 520 (500) 705 (678) 785 (755) 730 (702) 6 Ft & 12 Ft Case AHRI 1200 MED FF IC Rating Point 2 Discharge Air F ( C) 24 ( 4.44) 12 ( 24.44) 22 ( 30.00) 15 ( 26.11) Evaporator F ( C) 19 ( 7.22) 20 ( 28.88) 30 ( 34.44) 24 ( 31.11) Unit Sizing F ( C) 17 ( 8.33) 23 ( 30.55) 33 ( 36.11) 27 ( 32.77) Btu/hr per ft (Watts/m) Parallel 465 (447) 670 (620) 720 (693) 670 (645) Conventional 485 (467) 695 (645) 750 (722) 695 (669) Notes: 1. All data based on store temperature and humidity that does not exceed 75 deg F and 55% relative humidity. 2. For energy consumption comparison only. 3. Dual temperature operation kits are not suitable for ice cream temperature applications. 4. Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. Defrost Data Frequency (hours between defrost) 24 Defrost Water 2.2 lb/ft/day (3.3 kg/m) (± 15% based on case configuration and product loading). Offtime Time (minutes) Electric Temp Term ( F) 48 Failsafe (minutes) 60 Gas Time (minutes) FF 15 IC 18 FWGH Not Recommended Conventional Controls FWGH Low Pressure Backup Control CI/CO 5 FF 17 F / 29 F 27.2 C / 33.8 C IC 27 F / 39 F 32.7 C / 39.4 C Indoor Unit Only, Pressure Defrost Termination 5 Not Recommended 5 Use a Temperature Pressure Chart to determine PSIG conversions. Estimated Charge 6 FWGH 6 ft 1.9 lb 29 oz.9 kg 8 ft 2.5 lb 40 oz 1.1 kg 12 ft 3.7 lb 59 oz 1.7 kg 6 This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound. Product Data Recommended Usable Cube 7 (Cu Ft/Ft) AHRI Total Display Area 8 (Sq Ft/Ft) Shelf Area (Sq Ft/Ft) 7.28 ft 3 /ft (0.68 m 3 /m) 6.97 ft 2 /ft (2.12 m 2 /m) 5.50 ft 2 /ft (1.68 m 2 /m) 7 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 8 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 2 of 10 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FWGH Merchandiser Data Sheet
Excel Low / Medium Temperature, Wide Island Display with Glass Walls Excel FWGH Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Dimensions shown as in. and (mm). FWGH 36 (914) 15 (381) 15 ⅞ (403) 15 ¼ (387) Load Limit 33 (838) Load Limit 18 ½ (470) 3 ⅛ (79) Fan Coil Coil Fan 5 ¾ (146) Case-to-Case Connection 4 (102) 59 ¾ (1518) 1 ½ (38) 3 ¼ (83) Refrigeration 11 ¾ (298) 68 ⅞ (1749) 80 ⅝ (2048) NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials and cleanability. P/N 0540996_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 10
Dimensions shown as in. and (mm). Plan Views 73 ¾ (1874) 64 ½ (1638) Field Concection 41 ½ (1054) 8 ½ (217) Stub Up Area 6 x 6 (152 x 152) Waste Wireway Waste 61 ⅝ (1565) 43 ⅞ (1114) 4 ¼ (108) 4 ¾ (120) 29 ½ (750) Waste Waste 41 ½ (1054) Refrigeration 10 ¼ (261) 12 ⅛ (307) 4 ½ (115) 8 (203) 15 ¾ (400) 20 ¾ (529) 59 ¾ (1515) 70 ¼ (1784) 72 (1829) 80 ⅝ (2046) 26 ½ (673) 67 ½ (1715) FRONT 6 Foot Model 8 ½ (217) 64 ½ (1638) Field Connection 41 ½ (1054) Waste Stub Up Area 6 x 6 (152 x 152) Wireway 96 ⅜ (2448) 79 ⅜ (2010) Waste 43 ⅞ (1114) 4 ¼ (108) 4 ¾ (120) 29 ½ (750) 26 ½ (673) 84 ⅜ (2143) 90 (2286) FRONT 8 Foot Model 10 ¼ (261) 12 ⅛ (307) 4 ½ (115) 8 (203) 15 ¾ (400) 20 ¾ (529) Refrigeration 59 ¾ (1515) 70 ¼ (1784) 72 (1829) 80 ⅝ (2046) 4 of 10 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FWGH Merchandiser Data Sheet
Dimensions shown as in. and (mm). Plan Views 8 ½ (217) 64 ½ (1638) Field Connection 144 ½ (3670) 132 ½ (3366) 130 ⅜ (3312) 41 ½ (1054) Waste Stub Up Area 6 x 6 (152 x 152) Wireway Waste 43 ⅞ (1114) 4 ¼ (108) 4 ¾ (120) 29 ½ (750) 26 ½ (673) 138 ⅛ (3508) FRONT 12 Foot Model 10 ¼ (261) 12 ⅛ (307) 4 ½ (115) 8 (203) 15 ¾ (400) 20 ¾ (529) Refrigeration 59 ¾ (1515) 70 ¼ (1784) 72 (1829) 80 ⅝ (2046) ENDS or PARTITIONS Each standard end and each insulated partition adds 2 in. (38 mm) to case line up. PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Schedule 40 PVC Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 ESTIMATED SHIPPING WEIGHT Case Solid End 6 ft 8 ft 12 ft (each) lb (kg) 800 (363) 1400 (635) 1600 (726) 75 (34) Actual weights will vary according to optional kits included. P/N 0540996_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 10
Data Number of Fans 6 ft 8 ft 12 ft 4W Evaporator 4 4 4 Amperes Watts Evaporator Fan 6 ft 8 ft 12 ft 6 ft 8 ft 12 ft 120V 50/60Hz Energy Efficient 0.24 0.48 0.48 16 32 32 Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard 1.3 4 5 156 480 600 Minimum Circuit Ampacity 120V 50/60Hz Standard Energy Efficient 2.74 4.68 5.68 Maximum Over Current Protection 120V 20 20 20 Return Glass Anti-sweat Heaters 120V 50/60Hz Standard 0.16 0.18 0.24 18 20 28 208V Electric Defrost 13.1 15.38 23.07 2720 3200 4800 120V Koolgas Defrost 2.7 3.33 6.66 320 400 800 Standard Lighting None 6 of 10 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FWGH Merchandiser Data Sheet
Replacement Parts List Part # Description Part # Description Fan Assemblies 4W Standard Fan Assembly 0477653 Fan Motor/Evaporator 0546175 Fan Blade (8 ft only) 0464847 Fan Blade (6 &12 ft only) Heaters (Cont.) 208V Evaporator Defrost Heaters 0444057 6 ft case 3016524 8 ft case 3016527 12 ft case Thermostats Heaters 0398557 Defrost Termination Thermostat (Front/Electric Defrost only) 0398558 Defrost Termination Thermostat (Rear/Electric Defrost only) 0481370 Heater Switch (Koolgas Defrost only) 208V Drip Pan Defrost Heaters, Electric 0444300 6 ft case 0462160 8 ft case 0444296 12 ft case 120V Drip Pan Defrost Heaters, Koolgas 0465906 6 ft case 0465907 8 ft case 0465908 12 ft case Nosing Anti-sweat Heaters 0495006 6 ft case 0495007 8 ft case 0495008 12 ft case Return Grille Anti-sweat Heaters 0495010 6 ft case, Outside 0545637 8 ft case, Inside 0545574 8 ft case, Outside 0545638 12 ft case, Inside 0545575 12 ft case, Outside Return Glass Anti-sweat Heaters 3020071 6 ft case 0474785 8 ft case 0474786 12 ft case P/N 0540996_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 10
Fan Wiring Defrost - Standard Excel FWGH 120V Neutral 120V Power Brown Band Brown Band Brown Band Brown Band Fans Nosing Anti-Sweat Heater Return Grille Anti-Sweat Heater Refrigeration Thermostat (Optional) L1 208V Power From Defrost Contactors L2 Light Blue To Condensing Unit Red 6 Drip Pan Heater Red Defrost Termination Thermostat 5 To Condensing Unit Electric Defrost Heaters 6 Red Red Drip Pan Heater Return Glass Anti-Sweat Heater 5 Purple White Electric Defrost Heaters Purple White 120V Power 120V Neutral WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers 8 of 10 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FWGH Merchandiser Data Sheet
Optional Gas Defrost 120V Drip Pan Heater Koolgas Only 7 4 Heater Switch 208V/230V Drip Pan Heater Koolgas Only 7 7 4 Heater Switch 4 Heater Switch 120V Power 120V Neutral L1 L2 L1 L2 WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers P/N 0540996_F HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 9 of 10
Estimating Refrigeration and Load (for comparison purposes only) Case Btu To determine Btu for a case, refer to the performance data chart on Page 2. Select lit or unlit shelves, then select the type of remote refrigeration system (parallel or conventional), which will give Btu/hr/ft. Multiply this number by the length of the case to determine Btu per hour. Case Refer to store legend to determine number of circuits. Lighting should be specified in store legend. Line Sizing Refer to store legend. Hussmann Line Sizing Charts are engineered for use with Hussmann refrigeration equipment. Revision History Revision A: June 2014: Original Issue. Revision B: August 2015: Added gas defrost data on page 2. Revision C: January 2016: Updated fan assembly part numbers page 7. Revision D: May 2016: Added note on page 2. Revision E: March 2017: Added high glide refrigerant note. Revision F: January 2018: Added 6 foot data. Other changes marked with bar, underline or circle. 10 of 10 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FWGH Merchandiser Data Sheet