INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Similar documents
INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OUTLET HOT INLET COLD INLET INSTALLATION

TA-300, TA-300-LF, TA-350, TA-350-LF

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

INSTALLATION ADJUSTMENT SERVICE

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

MEGATRON MODEL 2, 3, 4, and 5

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

OUTLET LEONARDH THERMOSTATIC INSTALLATION

HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

OUTLET LEONARD THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

MEGATRON MODEL TA, TA-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

INSTALLATION, OPERATION AND MAINTENANCE

Installation Manual. Models 99168, 99169, 99170

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Installation Instructions PP-AS20 Anti-Scale System

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

Model TWBS.EW.H Tempered Water Blending System

Installation Instructions / Warranty. PuraVida 15775XX1

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

INSTALLATION & TESTING MANUAL

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

TUB AND SHOWER FAUCET

AeroVent 3X Product Manual

Installation Instructions / Warranty. Massaud

Nachi Series TM Z6957-XL

Installation Instructions

INSTALLATION & TESTING MANUAL

Whole House Filter Model: WH-LD

Installation Instructions / Warranty

Installation and Operation Guide

INSTRUCTION MANUAL HS-229G

Installation & Operation Manual

AeroVent 1 Product Manual

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

1. Connect Hose Attach a garden hose to the swivel nut hose fitting.

Instruction Manual. Nacho Cheese Dispenser and Warmer

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Instruction Manual. Carmel Apple-Dip Warmer

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Installation Instructions / Warranty. Metris 31060XX XX XX1

Installation S

Installation S

Installation S

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Model 9201EFE Tempered Water Blending System

User Manual. Hot Water Dispenser. Models: 177HWD15G 12/2018. Please read and keep these instructions. Indoor use only.

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Part No Revised: June TS1 TOASTER SYSTEM Instruction Manual Models # 5700 AND # 5700SF

Installation Instructions / Warranty

Model 9201EW Tempered Water Blending System

Troubleshooting the MPH 24FP Series Pedestal Hydrant

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Transcription:

. Bulletin XL-200 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES XL-200, XL-200-LF, XL-200-SW, XL-200-SW-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! LEONARD VALVE CO W A R M E R INSTALLATION 1. Valve should be installed at a location where it can easily be cleaned, adjusted or repaired. 2. The inlets are clearly marked on the valve body. Union angle strainer checkstops furnished must be installed on both supply lines as shown above. 3. A shutoff valve must be installed on the outlet pipe. Type XL valves do not have a built-in shutoff. 4. Use solder, or thread sealant sparingly. Supply pipes should be flushed before the valve is connected. Flush outlet pipe and valve as soon as it is connected. 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE CAUTION All thermostatic water-mixing valves have limitations. They will not provide the desired accuracy outside of their flow capacity range. Consult the flow capacity chart on page 5. Minimum flow must be no less than as shown. REMEMBER! THIS IS A CONTROL SYSTEM WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANCE GUIDE AND RECORD MGR-1000). 1360 Elmwood Avenue, Cranston, RI 02910 USA Phone: 401.461.1200 Fax: 401.941.5310 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com 1

METHOD #1 INSTALLATION REQUIRED METHODS OF PIPING XL SERIES Required when TEMPERED WATER is NOT CIRCULATED. Only the hot water supply to the mixing valve can be circulated with this piping arrangement. METHOD W Required when TEMPERED WATER IS CIRCULATED. OPERATION 1. Verify that the temperature of the hot water source is properly set and maintained. Shutoff and isolate the circulator pump. 2. Loosen LTR set screw located on temperature adjustment knob with allen wrench. 3. Turn on enough fixtures to flow approximately 10 GPM, turn knob clockwise until it stops (full cold) then counterclockwise until it stops (full hot), three times to exercise the thermostatic element. 4. Set mixing valve to the desired temperature, (See warning tag for temperature set point). Tighten LTR set screw. 5. Shut off all fixtures. Setup is complete. 6. Turn on circulator. With all fixtures still off, (no water flowing) observe the circulation temperature until it stabilizes. 7. If temperature rises, close balance valve until desired temperature is reached 2

INSTALLATION CONTINUED WARNING WARNING! This Thermostatic Mixing Valve has an Locking Temperature Regulator (LTR) which must be checked. If the temperature is too high, the installer MUST RESET this adjustment immediately. Always check the temperature of the mixed water after installation. Excessively hot water is DANGEROUS AND MAY CAUSE SCALDING! The LTR is factory set at approximately 120 F (49 C) with an incoming hot water supply temperature of 150 F (65 C) If the incoming hot water supply for your installation is higher than 150 F (65 C), the valve may deliver water in excess of 120 F (49) and the LTR MUST BE RESET BY THE INSALLER. SERVICE Leonard Type XL Thermostatic Water Mixing Valves are simple in design and may be easily cleaned, adjusted and repaired. If the installation is accessible, servicing may be completed without disconnecting the valve. NOTE: Thermostatic Water Mixing Valves are REGULATING mechanisms, which must be regularly maintained to provide best performance. Frequency of cleaning depends on quality of local water conditions and usage. (See Maintenance Guide and Record MGR-1000). TROUBLESHOOTING INSTRUCTIONS ITEM: PROBLEM: RECOMMENDED REPAIR KITS: PACKINGS & GASKETS 1. Leak at stem. 2. Leak between valve cover and base. KIT 1/XL200 SHUTTLE ASSEMBLY 3. Valve delivers either all hot or all cold water, or will not mix consistently. KIT R/XL200 CHECKSTOPS 4. Hot water bypass into cold line. 5. Supplies cannot be shut off completely. 6. Leak at checkstop bonnet. KIT 2/200/C REMEMBER! THIS IS A CONTROL DEVICE WHICH MUST BE CLEANED AND MAINTAINED ON A REGULAR BASIS. (SEE MAINTENANCE GUIDE AND RECORD, MGR-1000). 3

KIT KIT TYPE INCLUDES R/XL200 COMPLETE REPAIR 1-7 1/XL200 O-RING 2,3,6,7 2/200/C CHECK 11-15 ITEM # DESCRIPTION QTY. PART # / KIT # 1 SPRING, RETURN 1 KIT R/XL200 2 O-RING, LOWER SHUTTLE 1 KIT 1/XL200, KIT R/XL200 3 O-RING, UPPER SHUTTLE 1 KIT 1/XL200, KIT R/XL200 4 SHUTTLE ASSEMBLY 1 KIT R/XL200 5 RETAINING RING, COVER 1 7611, KIT R/XL200 6 O'RING, COVER 1 KIT 1/XL200, KIT R/XL200 7 O'RING, STEM 1 KIT 1/XL200, KIT R/XL200 8 STEM ASSEMBLY (DO NOT REMOVE SNAP RING) 1 781700 9 COVER 1 7856 10 KNOB ASSEMBLY 1 764000 11 LOWER STEM & PACKING 2 KIT 2/200/C 12 SCREEN 2 KIT 2/200/C 13 SPRING, CHECK 2 KIT 2/200/C 14 O-RING, BONNET 2 KIT 2/200/C 15 O-RING. UPPER STEM 2 KIT 2/200/C 16 STEM, UPPER CHECK 2 4727 17 CHECK BONNET 2 4723 18 SWIVEL (IF APPLICABLE) 2 4704 19 SWIVEL NUT (IF APPLICABLE) 2 4707 4

MIN. FLOW FLOW CAPACITIES PRESSURE DROP 5 10 15 20 25 30 35 40 45 50 PSI 0.3 0.7 1 1.4 1.7 2.1 2.4 2.8 3.1 3.4 BAR 5 69 96 117 135 148 163 174 188 198 208 GPM 18.9 216 363 443 511 560 617 659 712 750 787 l/min 220(833) 200(757) FLOW RATE GPM(l/min) 180(681) 160(606) 140(530) 120(454) 100(379) 80(303) 60(227) 0 5 (0.3) 10 (0.7) 15 (1.0) 20 (1.4) 25 (1.7) 30 (2.1) 35 (2,4) 40 (2.8) PRESSURE DROP PSI(BAR) 45 (3.1) 50 (3.4) LIMITED WARRANTY Leonard Valve Company warrants the original purchaser that products manufactured by them (not by others) will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with Leonard Valve Company's instructions, for a period of one year from date of shipment. During this period the Leonard Valve Company will at its option repair or replace any product, or part thereof, which shall be returned, freight prepaid, to the Leonard factory and determined by Leonard to be defective in materials or workmanship. There are no warranties, express or implied, which extend beyond the description contained herein. There are no implied warranties of merchantability or of fitness for a particular purpose. In no event will Leonard be liable for labor or incidental or consequential damages. Any alteration or improper installation or use of the product will void this limited warranty. 2015 Leonard Valve Company Printed in USA 1360 Elmwood Avenue, Cranston, RI 02910 USA Phone: 401.461.1200 Fax: 401.941.5310 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com 5