HOT INLET COLD INLET INSTALLATION

Similar documents
INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

OUTLET LEONARD THERMOSTATIC INSTALLATION

OUTLET LEONARDH THERMOSTATIC INSTALLATION

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

MODEL 210, 210-LF THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

TA-300, TA-300-LF, TA-350, TA-350-LF

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

OUTLET HOT INLET COLD INLET INSTALLATION

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

MEGATRON MODEL TA, TA-LF

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

CLASSIC HIGH LOW MANIFOLD SYSTEMS

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

Installation S

Installation S

Installation S

Installation S

Installation S

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

NEW GENERATION HIGH LOW SYSTEMS

INSTALLATION & TESTING MANUAL

INSTALLATION & TESTING MANUAL

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Instruction Manual. Cheese Warmer with Pump

Installation Instructions / Warranty. Metris 31060XX XX XX1

AM Series Proportional Thermostatic Mixing Valve

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

COMPLETE WATER TEMPERATURE CONTROL SYSTEM

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

1. Connect Hose Attach a garden hose to the swivel nut hose fitting.

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

1. Connect Hose Attach a garden hose to the swivel nut hose fitting.

INSTALLATION, OPERATION AND MAINTENANCE

Installation Instructions / Warranty

PALARRE, ROCHELLE WATER-GUARD VITREOUS CHINA SIPHON JET TOILET

Model 8356WCC Pull-Down Shower Eye/Face Wash

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Installation Instructions / Warranty

Model Combination Shower Eye/Face Wash

Installation Instructions / Warranty


Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

F-LF AND F-PF SERIES

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Model /8320CRP Shower and Eye/Face Wash

Installation and Maintenance "L" and "LS" Series

Installation Instructions PP-AS20 Anti-Scale System

Model 7656WCC Eye/face Wash

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

AeroVent 3X Product Manual

Faucet Care and Maintenance Guide. Answers to frequently asked questions on how to keep your Delta faucets at their best

MERIDIAN MODEL# 3793

WELLWORTH WATERGUARD VITREOUS CHINA SIPHON JET TOILET

MEMOIRS VITREOUS CHINA TOILETS

Transcription:

EMERGENY VALVE F EMERGENY VALVE Bulletin G-4 INSTALLATION SETUP AND OPERATING INSTRUTIONS WATER SYSTEMS TYPE TM-600, TM-600-LF, TM-650, TM-800, TM-800-LF, TM-850, TM-850-LF TM-5100, TM-5100-LF, TM-5125, TM-5125-LF IMPORTANT! Provide valve serial number, (stamped on valve cover) when ordering parts!! OT OLD REDUNDANT F OT OLD TM-600, TM-600-LF, TM-800, TM- 800-LF, TM-5100, TM-5100-LF Valve should be installed at a location where it can easily be cleaned, adjusted or repaired. INSTALLATION PRIMARY TM-650, TM-850, TM-850-LF TM-5125, TM-5125-LF Union angle strainer checkstops furnished must be installed on both supply lines as shown above. The inlets are clearly marked on the valve body casting. onnect the hot water into the inlet marked "OT" and cold water into the inlet marked "OLD." These are NOT to be confused with the "-" markings on the front cover. Use solder or pipe cement sparingly. Supply pipes should be flushed before the valve is connected. Flush outlet pipe and valve as soon as it is connected. Maximum Operating Pressure 125PSI (860 KPA) for ot and old Water. NOTE: It may be necessary to recirculate the tempered water to the face/eyewash/drench shower should the piping be exposed to excessive hot or cold conditions. onsult factory for proper piping. AUTION IMPORTANT! These systems are designed to provide mixed water from 60 to 90 F (15 to 2 ) for emergency shower applications only. all Leonard for systems designed to operate at temperatures outside of this range. REMEMBER! TIS IS A ONTROL SYSTEM WI MUST BE LEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANE GUIDE AND REORD MGR-1000). 160 Elmwood Avenue, ranston, RI 02910 USA Phone: 1.461.10 Fax: 1.941.510 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com

Leonard Type TM Thermostatic Water Mixing Valves are simple in design and may be easily cleaned, adjusted and repaired. If the installation is accessible, servicing may be completed without disconnecting the valve. TO RESET ADJUSTABLE IG TEMPERATURE LIMIT STOP: ADJUSTMENT AND SERVIE NOTE: Thermostatic Water Mixing Valves are REGULATING mechanisms, which must be regularly maintained to provide best performance. Frequency of cleaning depends on quality of local water conditions and usage. (See Maintenance Guide and Record MGR- 1000 and ANSI 58.1). WARNING SNAP AP STOP SREW LTR SET SREW 1. Loosen LTR set screw. 2. Remove SNAP AP, SREW & WASER. Remove.. Temporarily place on the spline rod, turn ANDLE to the left, allow cold water to flow. Slowly adjust handle to the right to required maximum temperature. (Temperatures above 90ºF are not recommended on Emergency equipment, consult medical advisor for correct temperature settings). 4. Replace on the spline rod so that its RIGT edge is resting against the STOP SREW located on the RIGT SIDE OF TE OVER. 5. The new maximum temperature has now been set. Test this temperature by holding a thermometer under the flow of water to be certain it is as desired. WARNING! This Thermostatic Mixing Valve has an adjustable high temperature limit stop which must be checked. If temperature is too high, the installer MUST RESET stop immediately. Always check the temperature of the mixed water when the lever handle is turned to full OT. If the Emergency Drench equipment is a combination type, the water temperature must be checked at each outlet (FAE/EYEWAS /SOWER) location independently, Excessively hot water is DANGEROUS AND MAY AUSE SALDING! onsult medical advisor for correct temperature setting. The high temperature limit stop is factory set at approximately 90 F (2.2 ) with an incoming hot water supply temperature of 150 F (65 ). If the incoming hot water on the job is higher than 150 F, the valve when turned to full hot will deliver water in excess of 90 F and the high temperature limit stop MUST BE RESET BY TE INSTALLER. TROUBLESOOTING INSTRUTIONS PAKINGS & GASKETS Leak at pointer rod. Leak between valve cover and base TM-600, 650, 800, 850 REPAIR KIT 1/50M TM-5100, 5125 REPAIR KIT 1/125M ASSEMBLY Valve delivers either all hot or all cold water, or will not mix consistently. REPAIR KIT TGM-1/50M or REPAIR KIT R/50M REPAIR KIT TGM-1/125M or REPAIR KIT R/125M TERMOSTAT After cleaning or replacing port sleeve assembly, valve will not hold temperature. REPAIR KIT TGM-2/50 or REPAIR KIT R/50M REPAIR KIT TGM-2/125 or REPAIR KIT R/125M EKSTOPS ot water bypass into cold line. Supplies cannot be shut off completely. Leak at checkstop bonnet. REPAIR KIT 2/50M REPAIR KIT 2/50M SEE PAGE 5 FOR OMPLETE PARTS BREAKDOWN, AND PARTS KITS If installed on a circulated hot water system, make certain the valve is piped according to Leonard Required Methods of Piping (see page ). REMEMBER! TIS IS A ONTROL DEVIE WI MUST BE LEANED AND MAINTAINED ON A REGULAR BASIS. (SEE MAINTENANE GUIDE AND REORD, MGR-1000). 2

F F EMERGENY VALVE REQUIRED METOD OF PIPING TM VALVES METOD #1 Required when hot water is to be circulated to a thermostatic mixing valve, which is a substantial distance from the hot water source. Recommended ot Water Inlet Temperature 1ºF (60º). TO OT WATER SOURE SWING EK OT SUPPLY OLD SUPPLY OT OLD REDUNDANT OT OLD OT SUPPLY TO OT WATER SOURE OLD SUPPLY PRIMARY TM-650, 850, 5125 TM-600, 800, 5100 ADJUSTMENT SREW The TM-650, 850 & 5125 Redundant Thermostatic Mixing Valve has been factory set at 90 F (2 ). This set point can be field adjusted with a /8 wrench (see diagram). lockwise direction will increase temperature. Maximum set point is 100 F (8 ). onsult medical advisor for correct temperature setting. As a secondary level of protection, in the event of redundant valve failure, installing contractor may wish to prevent cold water contamination by installing a swing check valve on the cold water supply to the valve (only needed on TM-650, 850, and 5125). This unit must be cycled each time the emergency equipment is checked. (See ANSI Z58.1, Maintenance and Training section). ycle redundant thermostatic valve by loosening the pointer set screw and set the primary thermostatic mixing valve to full hot. (TM-650, TM-850, TM-5125 only). Open drench or combination emergency shower and allow temperature to reach the set point. Temperature will drop when secondary valve opens to cool output. Turn primary thermostatic valve to full cold and wait ten seconds, this will close secondary valve. Turn primary thermostatic valve to full hot and wait for ten seconds. heck to be sure outlet temperature does not climb above 90 F (2 ) or above recommended maximum temperature set by medical advisor. Turn primary thermostatic mixing valve to full cold and wait ten seconds. Set primary thermostatic mixing valve to the desired temperature and close drench or combination emergency shower.

INSTRUTIONS FOR DISMANTLING VALVE Shut off hot and cold supplies to valve. Loosen SET SREW, Remove SNAP AP, SREW and WASER, and FRITION. (FIGURE #1). Remove the 6 OVER SREWS, then take off cover to which the Thermostat and Gears are attached. WEN RE-ASSEMBLING VALVE, insert new Flange Packing in base; replace OVER, tightening OVER SREWS in rotation; put FRITION in place; then replace and ROD SREW, WASER and AP. After installing new parts, it will probably be necessary to reset Pointer to obtain correct temperature range from old to ot. See page 2 instructions "TO RESET ADJUSTABLE IG TEMPERATURE LIMIT STOP." TO LEAN ASSEMBLY Failure to properly blend the water may be caused by a sticking condition in the ASSEMBLY. The TIMBLE should slide freely on the. If a deposit of lime or sediment prevents free movement, use a nail set or other tapered tool to unscrew the EK NUT as far as it will go, then screw the NUT into the base. This will release the and TIMBLE so they can be lifted out, (Figure #2). lean with a NON-ORROSIVE LEANING AGENT AND SOFT LOT - DO NOT USE ABRASIVES - then wash parts thoroughly, wipe with a dry cloth and re-assemble. The should be assembled with the elongated holes to the right (OLD SIDE). Tighten NUT against end of but be careful not to over tighten, this may deform port sleeve. Tighten EK NUT. When replacing front be sure DRIVING BALL is inserted in Ball Socket as shown in Figure #1. TO REPLAE WIT GEAR Loosen SET SREW, remove SNAP AP, SREW, WASER,, and FRITION. (FIGURE #1) Remove OVER with parts attached, from the front of valve. Remove OIL SLEEVE and take off TERMOSTAT. Replace with GEAR and re-assemble. TO REPLAE (OR LEAN) TERMOSTAT Follow instruction for replacing with GEAR above. If a deposit has collected on the Thermostatic oil, clean it off with a brush in a non-corrosive grit-free cleaning solution. 1. ROD WIT GEAR 2. LTR SET SREW PORT SLEEVE DRIVING BALL OIL SLEEVE PAKING TIMBLE EK NUT PORT SLEEVE NUT BALL SOKET ELONGATED OLES ALWAYS TO RIGT REMEMBER! TIS IS A ONTROL DEVIE WI MUST BE LEANED AND MAINTAINED ON A REGULAR BASIS. (SEE MAINTENANE GUIDE AND REORD, MGR-1000) 4

TM-600, 650, 800, 850 VALVE PARTS TM-15B/50 OVER TGM-2/50 TERMOSTAT 57-L SNAP AP TM-25 TM-25D STOP TM-8 OIL SLEEVE (2 REQD.) TM-29/29A SREW W/WASER TM-16 OVER SREWS 0 FRITION TM-21/50 PAKING TM-28A TGM-1/50M TM-16A/50M DIAL PLATE TM-/50M NUT FOR TM-600, TM-650, TM-800, TM-850 EKSTOP PARTS BODY 0 & PAKING UPPER STEM MU-4A 0 (OT SIDE) 015 BLUE (OLD SIDE) 04/50 SWIVEL 09/50 SWIVEL NUT 01 SREEN 014 AP PAKING 05 PAKING 06 STRAINER AP 02 BONNET REPAIR KITS FOR TM-600, 650, TM-800 & 850 KIT 1/50M PAKINGS & GASKETS & PAKING (2) (4) (OT & OLD) NUT. KIT R/50M REBUILDING KIT SREEN (2) (2) BONNET (2) AP PAKING (2) LOK-TYPE (SUFFIX LTR) OIL SLEEVE. KIT 2/50M EKSTOP KIT TERMOSTAT All TM-600, 650, 800 & 850, valves are furnished with lockable pointers. See part noted. TM-6 SET SREW & PAKING (2) UPPER STEM (2) (OT & OLD) SREEN (2) AP PAKING (2) BONNET (2) REMEMBER! TIS IS A ONTROL DEVIE WI MUST BE LEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANE GUIDE AND REORD, MGR-1000) NOTE: AFTER INSTALLING NEW PARTS IT WILL BE NEESSARY TO RESET TE ADJUSTABLE IG TEMPERATURE LIMIT STOP (SEE PAGE 2). 5

TM-5100, 5125 VALVE PARTS 57-L SNAP AP TM-25 TM-15B/125 OVER TM-25D STOP TGM-2/125 TERMOSTAT TM-8 OIL SLEEVE (2 REQD.) EKSTOP PARTS BODY TM-29/29A SREW W/WASER FOR TM-5100, TM-5125 0 & PAKING UPPER STEM MU-4A 0 (OT SIDE) 015 BLUE (OLD SIDE) 04/125 SWIVEL 09/125 SWIVEL NUT 01 SREEN TM-16 OVER SREWS 014 AP PAKING 05 PAKING 06 STRAINER AP 0 FRITION TM-21/125 PAKING 02 BONNET LOK-TYPE (SUFFIX LTR) REPAIR KITS FOR TM-5100, TM-5125 KIT 1/125M PAKINGS & GASKETS & PAKING (2) TM-28A TGM-1/125M (4) (OT & OLD) NUT. TM-16A/125M DIAL PLATE TM-/125M NUT KIT R/125M REBUILDING KIT SREEN (2) (2) BONNET (2) AP PAKING (2) All TM-5100, 5125 valves are furnished with lockable pointers. See part noted. TM-6 SET SREW OIL SLEEVE. KIT 2/50M EKSTOP KIT UPPER STEM (2) SREEN (2) TERMOSTAT BONNET (2) REMEMBER! TIS IS A ONTROL DEVIE WI MUST BE LEANED AND MAINTAINED ON A REGULAR BASIS (SEE MAINTENANE GUIDE AND REORD, MGR-1000) & PAKING (2) (OT & OLD) AP PAKING (2) NOTE: AFTER INSTALLING NEW PARTS IT WILL BE NEESSARY TO RESET TE ADJUSTABLE IG TEMPERATURE LIMIT STOP (SEE PAGE 2). 6

FLOW APAITIES 55 50 TM-600 TM-800 TM-5100 TM-650 TM-850 TM-5125 PRESSURE DROP P.S.I.G. 0 10 0 2 4 5 6 7 8 10 0 50 60 70 80 100 150 0 MAXIMUM FLOW APAITY GALLONS PER MINUTE MODEL IN OUT MINIMUM FLOW () INTERNAL OLD WATER BY-PASS MINIMUM 5 0. 10 0.7 15 1.0 PRESSURE DROP 25 0 5 1.4 1.7 2.1 2.4 2.8 45.1 PSI BAR *TM-600 /4" 1" 14 19 25 5 72 95 28 106 0 8 4 125 144 44 167 51 19 TM-650 /4" 1" 14 19 25 5 72 95 28 106 0 8 4 125 144 44 167 51 19 *TM-800 1" 25 0 95 4 125 5 8 4 12 144 16 50 189 56 212 *TM-850 25 0 95 4 125 5 8 4 12 144 16 50 189 56 212 TM-5100 1 1/2" 151 5 1 64 242 72 81 90 99 108 27 07 41 74 9 7 44 126 477 TM-5125 1 1/2" 151 5 1 64 242 72 27 81 07 90 41 99 74 108 9 7 44 126 477 MAXIMUM FLOW APAITY LIMITED WARRANTY Leonard Valve ompany warrants the original purchaser that products manufactured by them (not by others) will be free from defects in materials and workmanship under normal conditions of use, when properly installed and maintained in accordance with Leonard Valve ompany's instructions, for a period of one year from date of shipment. During this period the Leonard Valve ompany will at its option repair or replace any product, or part thereof, which shall be returned, freight prepaid, to the Leonard factory and determined by Leonard to be defective in materials or workmanship. There are no warranties, express or implied, which extend beyond the description contained herein. There are no implied warranties of merchantability or of fitness for a particular purpose. In no event will Leonard be liable for labor or incidental or consequential damages. Any alteration or improper installation or use of the product will void this limited warranty. 15 Leonard Valve ompany Printed in USA 160 Elmwood Avenue, ranston, RI 02910 USA Phone: 1.461.10 Fax: 1.941.510 Email: info@leonardvalve.com Web Site: http://www.leonardvalve.com 7