ASSE 1017 Point of Source Commercial. Mixing Valves. Mixing Valves. MVA (34A) Series/MVAH Hydronic Series

Similar documents
HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

Automatic Temperature Controller (ATC)

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

WATER CONTROL VALVES

Series 20 Dual Check Backflow Preventers

SECTION DOMESTIC WATER PIPING SPECIALTIES

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

Honeywell Water Solutions. Thermostatic Mixing Valves

2016 CASH ACME CATALOG

Thermostatic Radiator Valves (Caleffi)

Taco 00 Series Cartridge Circulators

CONNECTION SYSTEM Reliance Worldwide USA

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

TMV45 & TMV80 Standard Thermostatic Mixing Valves

Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

THERMOSTATIC MIXING VALVES

ADMS. AERCO Digital Mixing Station. AERCO.com

Home. One Source For All Your Potable Water Needs

Quality, Service. A history of. and Innovation

A. This Section includes the following domestic water piping specialties:

INSTANT-FLOW C-MICRO WATER HEATER

AM Series Proportional Thermostatic Mixing Valve

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

INSTALLATION ADJUSTMENT SERVICE

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

INSTANT-FLOW C-MICRO WATER HEATER

CONNECTION SYSTEM AUGUST Reliance Worldwide USA

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

CONNECTION SYSTEM JULY

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic Mixing Valves

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

DigiTemp. Digital Water Tempering System. PVI.com

10-MINUTE "EXPERT" dahl Edition

POINT-OF-USE WATER HEATERS

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

7000BT Eye/Face Washes

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Tri-Max Aerator GPM. Three flow rate options Patented FlexFlo technology Dual-thread brass connection

Domestic Hot Water Systems and Plumbing Products

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Thermostatic mixing valves with interchangeable cartridges

Viega ProPress Marine Systems Safe, secure connections across the seas.

Rada 320R Installation and Maintenance

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Tube Clamp Submittal Information Revision A: July 25, 2013

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Multilux 4-Eclipse-Set

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

In-Line Air Separators

Healthcare Solutions. Water, faucets, and the fight against healthcare-associated infections (HAIs)

HL45, HL80 Thermostatic High-Low Valves

The New Caroma TMV20

Flow Control for Fire Protection

Installation. S Series Navigator Thermostatic Mixing Valve

T HE U NIVERSE E LECTRONIC F AUCETS

Rada 425R Installation and Maintenance

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

SECTION METERS AND GAGES FOR HVAC PIPING

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

Engineering Specifications

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OUTLET HOT INLET COLD INLET INSTALLATION

Hydronic Separator. Hydro Separator. Hydro Separator. 548 tech brochure Hydro Separator ASME. tech brochure 01076

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Electric Tankless Water Heaters

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

TOP 15 :: EMERGENCY EQUIPMENT

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Hydronic Expansion Tanks THE ONE THAT STARTED IT ALL

RA15/6T & TB Conversion Valve

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Installation S

Hydronic Product & Application Catalog

Flow Control for Fire Protection

technological solutions LIST PRICE BOOK Building the Future Together Effective November 1, 2016 All Prior Issues Void PL-CIM_V0013.

UL/FM Fire Protection Products Setting the Standard

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers

Transcription:

ASSE 1017 Point of Source Commercial Mixing MVA (34A) Series/MVAH Hydronic Series The Apollo MVA thermostatic master mixing valves are designed for ASSE 1017 point of source applications. They provide reliable hot water temperature control of potable and hydronic hot water distribution systems. NEW Superior thermostatic element technology for optimal performance, reliability and accuracy Integral inlet strainers and check valves are standard to protect against cross-flow and foreign particles in the piping system Thermostat over-temperature control Maximum temperature limit option Fingertip temperature control Materials of construction meet the requirements of the EPA Safe Drinking Water Act Instantaneous cold or hot water supply failure shut-off protection Multiple connection options to fit your specific needs High temperature version for hydronic/radiant heating applications ASSE 1017 - Temperature Actuated Mixing Valve for Hot Water Distribution Systems CSA B125.3 - Plumbing Supply Fittings MATERIAL Body: Shuttle: Sensor: O-ring: Spring: Cap: ASTM B Bronze Noryl Modified PPO (Polyphenylene Oxide) Copper/Wax filled Chloramine Resistant EPDM ASTM A313 Stainless Steel ABS (Acrylonitrile Butadiene Styrene) Maximum working pressure - 10 psig (10 kpa) Maximum working temperature - 210 F (99 C) Cold water inlet temperature range - 39-80 F (4-27 C) Hot water inlet temperature range - 120-180 F (49-82 C) Minimum Flowrate* - 1/2 gpm (1.9 lpm) Flowrate at 30 psid (138kPA) - 19 gpm (64 lpm) Mixed water temperature range - 85-140 F (30-60 C)/ 130-180 F (54-82 C) Mixed water temperature tolerance - ±5 F (1.7 C) * Minimum flow when the valve is installed with recirculating water pump. FLOW CURVE Flow curve is based on the following: Cold and hot water inlet pressures at 45 psig; cold water supply temperature at 55 ±5 F; hot water supply temperature at 140 ±5 F, and mixed water temperature at 105 ±5 F. 4

Commercial High Capacity Mixing MVC (34C Series) The Apollo Model MVC (34C Series) ASSE 1017 listed, highcapacity mixing valves are thermostatically controlled regulating valves designed for use in large commercial and institutional potable point of source and non-potable hot water systems or applications. Simple adjustment of water temperature from 90-140 F or 130-180 F. Sizes 3/4, 1, 1-1/4, 1-1/2, 2 Standard temp range 90-140 F High temp range 130-180 F (use suffix H1 ) for hydronic/ radiant heating systems Highest flow in its class Threaded connections Installs easily on heating source Patented design for easy in-line maintenance Supply pressures to 150 psig U.S. Patent #6,328,219 ASSE 1017 approved CSA B125-01 ORDERING NUMBERS High Temp. Size (in.) Part No. Part No. 3/4 34C-104-01 34C-104-H1 1 34C-105-01 34C-105-H1 1-1/4 34C-106-01 34C-106-H1 1-1/2 34C-107-01 34C-107-H1 2 34C-108-01 34C-108-H1 Special Features Selected Apollo 34C mixing valves feature a two-piece shuttle with integral over-travel spring so they're smaller and easier to install than other high-capacity valves. Plus their patented snap-fit element retainer and shuttle with special finger-grip pads assure easy removal and servicing without tools. 3/4-1 34C-104/34C-105 1-1/4-2 34C-106/34C-108 6

MVB (34B Series) ASSE 1070/1016 Point of Use Mixing The Apollo Model MVB (34B Series) thermostatic mixing valves are designed to control and limit the volumes of cold and hot water required to deliver mixed water at a predetermined temperature either from the point of sourc or point of use application for single or multiple fixtures. Highest capacity that meets ASSE 1070 Superior thermostatic element technology for optimum reliability, dependability and accuracy Integral strainers and check valves provide protection against cross-flow and foreign particles Thermostat over-temperature protection Tamper resistant locking cap feature Maximum temperature setting adjustment Meets the requirements of the EPA Safe Drinking Water Act Instantaneous cold or hot ater supply failure shut-off protection Multiple connecton options to fit your specific needs NEW ASSE 1017 - Temperature Actuated Mixing Valve for Hot Water Distribution Systems ASSE 1070 - Water Temperature Limiting Device CSA B125.3 - Plumbing Supply Fittings Maximium working pressure =150 psig (1034 kpa) Maximum working temperature =210 F (99 C) Hot water inlet temperature range =120-180 F (49-82 C) Mixed water temperature range =80-120 F (27-49 C) Mixed water temperature tolerance = ± 3 F (1.7 C) Minimum flow rate =1 gpm (3.7 lpm) Model Series Connection Number Number Type A B C D E Unit F Wt. (lbs) MVB12 34B213T 1/2 FNPT 4.52 2.11 2.28 4.56 1.87 0.73 2.75 MVB34 34B214T 3/4 FNPT 4.52 2.11 2.28 4.56 1.87 0.77 2.84 MVB1 34B215T 1 FNPT 4.52 2.11 2.28 4.56 2.12 0.94 2.93 MVBS12 34B213S 1/2 Solder 4.52 2.11 2.28 4.56 1.87 0.81 2.54 MVBS34 34B214S 3/4 Solder 4.52 2.11 2.28 4.56 1.87 0.81 2.60 MVBS1 34B215S 1 Solder 4.52 2.11 2.28 4.56 2.12 0.94 2.66 MVBC12 34B213C 1/2 CPVC 4.52 2.11 2.28 4.56 1.87 0.58 2.39 MVBC34 34B214C 3/4 CPVC 4.52 2.11 2.28 4.56 1.87 0.80 2.42 MVBC1 34B215C 1 CPVC 4.52 2.11 2.28 4.56 2.12 1.09 2.45 MVBX12 34B213X 1/2 PEX 4.52 2.11 2.28 4.56 1.87 0.83 2.54 MVBX34 34B214X 3/4 PEX 4.52 2.11 2.28 4.56 1.87 0.83 2.60 MVBX1 34B215X 1 PEX 4.52 2.11 2.28 4.56 2.12 1.04 2.66 www.apollovalves.com 7

Hydronic Tempering 34-100 Series Designed to provide non-asse extension of water heater capacity and hot water temperature control in hydronic heating applications. Numbered indicator control allows easy setup and fingertip control. Available in low or high temperature options depending on floor or baseboard application. Low temperature range (100-130 F) High temperature range (120-150 F) Stainless steel spring and rings Corrosion resistant bronze body Thermoplastic shuttle assembly Thread or solder connections In-line repairable Low flow restriction Fingertip temperature control Dimensions(in.) Size Connection A B C D 1/2" solder 2.563 1.938 1.625 3.688 1/2" threaded 2.688 1.938 1.750 3.625 3/4" solder 3.063 2.063 2.063 3.875 3/4" threaded 2.938 2 2 3.750 ORDERING NUMBERS STANDARD MODEL Size(in.) Threaded Solder 1/2 34-105-01 34-103-01 3/4 34-106-01 34-104-01 LOW TEMPERATURE MODEL Size (in.) Threaded Solder 1/2 34-105-L1 34-103-L1 3/4 34-106-L1 34-104-L1 To Order Repair Kits: 34-100-01RK for Standard Temp. 34-100-L1RK for Low Temp. www.apollovalves.com 3

ASSE 1070/1016 Point of Use Mini Mixer Mixing MVD (34D Series) The new Apollo MCVD (34D Series) Mini Thermostatic mixing valves are designed for ASSE 1070 Point of Use temperature control applications with a single fixture using proven ASTM grade materials. These valves will hold a desired temperature within ± 2 F and will shut off in the event of hot or cold water failure. They come equipped with a tamper-resistant high temperature limit stop to prevent the valve from being stet above 120 F. 100% Made in the USA New tamper resistant locking control knob Adjustable maximum temperature limit stop Crush proof integral check valves Hot/cold water failure protection Single outlet for sensor faucets Bypass fitting option for dual control faucets Satin chrome plating option 3/8 compression connections Outlet temperature range (85 F - 120 F) Maximum pressure: 125 psig Maximum inlet temperature: 210 F Minimum flow rate 0.5 GPM ASSE 1070 - Performance Requiremens for Water Temperature Limiting Devices ASSE 1016-96 - Individual Thermostatic Control Valve for Individual Fixtures CSA B125.3-05 - Plumbing Fittings Model Series Description Weight MVD 34D30201 3/8 Single Out Bronze.82 MVDR 34D30217 3/8 Single Out Chrome.82 MVDB 34D302B1 3/8 Double Out Bronze 1.0 MVDBR 34D302B17 3/8 Double Out Chrome 1/0 8