VAC1 Series-Division 2 / Zone 2

Similar documents
VAC1 Series - Division 2 / Zone 2

Capacity: 1.5 to 6.0 Ton

Capacity: 1.5 to 6.0 Ton

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

VACPB1 Series - 60 Hz Models

CU-MS & AH-HW Mini-Split Series

Explosion Proof Hazardous Location Roof Top A/C Units

Portable Vertical Air-Conditioning and Heating Systems

CENTRAL SPLIT UNIT UNIC

General Description. Operation

PAJ3. Product Specifications

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

MAC N-407 Air-Cooled Chiller

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

Precise Temperature Control; Compact Footprint

MACH N-407 Heat Pump Air-Cooled Chiller

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

FX5 Series Explosion-Proof Electric Air Heaters

Installation Instructions

48TF GAS HEATING/ ELECTRIC COOLING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

MODEL IX-WAC AIR CONDITIONERS FOR HAZARDOUS & HIGHLY CORROSIVE AREAS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Split System Cooling Product & Performance Data

Corporation , Soraji-ro, Paju-si, Gyeonggi-do, Republic of Korea (Postal Code: 10863)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

48TM GAS HEATING/ELECTRIC COOLING UNITS

GREEN REFRIGERANT R-410A

Advance Release September 2009

Self-Contained & Split System Reverse Cycle Air Conditioners Models

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Description. Applications

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

50TM TFF COMBINATION HEATING/COOLING UNITS

WALL-MOUNT HEAT PUMPS - (60HZ)

50TM COMBINATION HEATING/COOLING UNITS

Indoor Air Handlers with Compressors MVS and MVW

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Commercial High-Efficiency Condensing Units

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Q-TEC QC-Series Chilled Water Air Conditioner

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Comfort. Description. Applications

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Call us today! (800)

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

Hazardous Location Certified

Condensing Units & Air Handlers

Q-Tec TM QC-Series Chilled Water Air Conditioner

CF1 ProVector Explosion-Proof Heaters

MODEL CX -WAC/HP AIR CONDITIONERS & HEAT PUMPS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Split System Heat Pump Product Data

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

48PGD/E/F/L/M/N PG20-28

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Self-Contained Reverse Cycle Air Conditioners

FE1 Explosion-Proof Electric Air Heaters

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

RGE 13 A T - 1 A

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

SMALL AIR COOLED CONDENSERS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

American Brand with Global Reach. Model: SMLW-SAGL

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Packaged Terminal Air Conditioners

Call us today! (800)

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

Super-Flo Low Profile Unit Cooler

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

AIR COOLED PACKAGED CHILLER

Transcription:

VAC1 Series-Division 2 / Zone 2 Wall Mount Explosion Proof Air Conditioner System CSA Certified For Use in Division 2 Hazardous Locations 60 Hertz s 21,200 59,000 60 Hertz, High Ambient, & Custom Designs Available Contact Safe Air Technology Sales Team for Assistance Standard Features All Components UL and / or CSA Certified Overload Protection on Motors and Compressors Non Sparking Condenser Fan Blade Aluminum Finned Copper Tube Coils Twin Blowers to Move Air More Quietly Built-in Full Length Mounting Brackets Motors are Easily Accessible for Fast and Easy Maintenance Powder Coated Steel Cabinet Engineering Data Sheets Available with Detailed System Specification N.E.C. and I.E.C. Certificate of Conformance Issued for Hazardous Location Operation, Maintenance, and Installation Manuals Included Offering The Keys to Success: Quality Pricing On Time Delivery

System Description Safe Air Technology VAC1 Series Systems are designed to provide cooling, and heating for industrial, severe duty, and marine applications. Our standard VAC1 Series product line has been carefully engineered and manufactured to ensure a quality product that will provide many years of reliable service. Safe Air Technology also has an in-house engineering team that can custom design a VAC1 to meet your specific needs. Our units are fully tested for operational performance and NEC / IEC Compliance to ensure customer satisfaction and many years of safe operation. Safe Air Technology works with its customers to determine the most appropriate system for the customer s application. Once the correct system has been selected, Safe Air Technology will provide an Engineering Submittal Package for approval prior to the manufacturing of the system Safe Air Technology works equipment is NEC and IEC 3 rd Party Certified by CSA International. System Applications Industrial Refineries Fuel Transfer Docks and Pumping Stations Chemical Plants Analyzer Buildings Offshore Platforms MCC Rooms Gas Plants and Pipelines Control Rooms Specifications A/C Specifications All Components UL and CSA Approved Maintenance Friendly General Purpose Control Box Included for A/C Explosion Proof Motor and Compressor Overload Protection Installed General Purpose Thermostat Included to Control Room Temperature High and Low Pressure Safety Switches Installed Easily Accessible Condenser Fan Section with Non Sparking Fan Blade System Shut-Down Provided in Case of Gas/ Smoke Detection (Gas Detectors Provided by Others) Industrial Grade Scroll Compressor R-410 Refrigerant Installed Twin Blowers to Move Air Quickly and Quietly Copper Tubes with Aluminum Fin Coils Installed Fully Tested for Operational Performance and NEC Compliance O & M Manuals Included Certificate of Conformance to Explosion Proof Codes Issued

Available Options -ADC Adsil Coated Coils and All Copper Lines for Corrosion Protection -B Group B Classification -CC Copper Tube and Copper Fin Coils -CRT Export Crate for Sea/Air Shipping -SD Smoke Detector Installed -CF Custom Filtration -HC Humidity Controls Installed -SH6 -WC -XPR -MG1 -MG2 316 Stainless Steel Housing Water Cooled Condenser Coil Explosion Proof Receptacle Installed Marine Grade Option 1-Coila and Copper Coated for Corrosion Protection Marine Grade Option 2-Coils, Copper, and Sheet Metal Coated for Corrosion Protection -DSI Disconnect Switch Installed -RMT Remote Control Box -DW Double Wall-Evaporator Section -EPX 646 Epoxy Coated Metal for Corrosion Protection -HCC Heresite Coated Coils Available Designs -HG Hot Gas Bypass Valve Installed Safe Air Technology Also Offers Standard -HL High and Low Pressure Safety Switches Installed Wall Mounted Systems Designed for the Following Applications -ISV Refrigeration Isolation Valves High Ambient The VAC1 Series Can Be Designed to -LAC -LOC -MOD -PBD -RT Low Ambient Controls Installed Lock Out Switch Installed (Standard Feature) Custom Modification (Consult Sales Dept.) Pressure Blower Isolation Damper Remote Thermostat Temperatures 50 Hertz Power Supply Operate in Temperatures up to 115 o F (46 o C). Custom Systems Are Available for Applications that Exceed These Temperatures. 50 Hertz Power Supply Options Are Available, Please Contact Sales for NOTE: If an option you require due to your specifications is not listed, please contact our Sales Engineering Department. We will be happy to assist in ensuring that your system fully complies with your specifications Custom Applications If your Project Requires an Additional Specification Not Listed in This Catalog, Please Contact the Sales

VAC1 Series Standard Layout and Design NOTE: This is a Typical VAC1 Layout Drawing, Contact Safe Air Technology for a Specific Drawing

VAC1 Series 230/208-1 Ph / 60 Hz 1.5 Ton s VAC1-H-D-1.5-N-2-CND-ICD2-1C-LOC 18,000 N/A 230/208-1 16 20 600-.2 ESP 300 VAC1-H-D-1.5-5KW(EH/S)-2-CND-ICD2-1C-LOC 18,000 12,799 230/208-1 30 30 600-.2 ESP 300 VAC1-H-D-1.5-10KW(EH/S)-2-CND-ICD2-1C-LOC 18,000 25,598 230/208-1 56 60 600-.2 ESP 300 2 Ton s VAC1-H-D-2.0-N-CND-ICD2-1C-LOC 24,000 N/A 230/208-1 21 30 800-.2 ESP 325 VAC1-H-D-2.0-5KW(EH/S)-2-CND-ICD2-1C-LOC 24,000 12,799 230/208-1 30 56 800-.2 ESP 325 VAC1-H-D-2.0-10KW(EH/S)-2-CND-ICD2-1C-LOC 24,000 25,598 230/208-1 56 60 800-.2 ESP 325 2.5 Ton s VAC1-H-D-2.5-N-2-CND-ICD2-1C-LOC 30,000 N/A 230/208-1 24 35 1000-.4 ESP 355 VAC1-H-D-2.5-5KW(EH/S)-2-CND-ICD2-1C-LOC 30,000 12,799 230/208-1 32 35 1000-.4 ESP 355 VAC1-H-D-2.5-10KW(EH/S)-2-CND-ICD2-1C-LOC 30,000 25,598 230/208-1 58 60 1000-.4 ESP 355 VAC1-H-D-2.5-15KW(EH/S)-2-CND-ICD2-1C-LOC 30,000 38,396 230/208-1 84 90 1000-.4 ESP 355 MCA: Amapacity MEFC: or Breaker

VAC1 Series 230/208-1 Ph / 60 Hz 3 Ton s VAC-1-H-D-3.0-N-2-CND-ICD2-1C-LOC 36,000 N/A 230/208-1 29 35 1100-.3 ESP 355 VAC1-H-D-3.0-KW(EH/S)-2-CND-ICD2-1C-LOC 36,000 12,799 230/208-1 32 35 1100-.3 ESP 355 VAC1-H-D-3.0-10KW(EH/S)-2-CND-ICD2-1C-LOC 36,000 25,598 230/208-1 58 60 1100-.3 ESP 355 VAC1-H-D-3.0-15KW(EH/S)-2-CND-ICD2-1C-LOC 36,000 38,396 230/208-1 84 90 1100-.3 ESP 355 3.5 Ton s VAC1-H-D-3.5-N-2-CND-ICD2-1C-LOC 42,000 N/A 230/208-1 33 50 1400-.3 ESP 500 VAC1-H-D-3.5-5KW(EH/S)-2-CND-ICD2-1C-LOC 42,000 12,799 230/208-1 33 50 1400-.3 ESP 500 VAC1-H-D-3.5-10KW(EH/S)-2-CND-ICD2-1C-LOC 42,000 25,598 230/208-1 59 60 1400-.3 ESP 500 VAC1-H-D-3.5-15KW(EH/S)-2-CND-ICD2-1C-LOC 42,000 38,396 230/208-1 85 90 1400-.3 ESP 500 4 Ton s VAC1-H-D-4.0-N-CND-ICD2-1C-LOC 48,000 N/A 230/208-1 37 50 1550-.2 ESP 500 VAC1-H-D-4.0-5K(EH/S)-2-CND-ICD2-1C-LOC 48,000 12,799 230/208-1 37 50 1550-.2 ESP 500 VAC1-H-D-4.0-10K(EH/S)-2-CND-ICD2-1C-LOC 48,000 25,598 230/208-1 59 60 1550-.2 ESP 500 VAC1-H-D-4.0-15KW(EH/S)-2-CND-ICD2-1C-LOC 48,000 38,396 230/208-1 85 90 1550-.2 ESP 500 MCA: Amapacity MEFC: or Breaker

VAC1 Series 230/208-1 Ph / 60 Hz 5 Ton s VAC1-H-D-5.0-N-2-CND-ICD2-1C-LOC 60,000 N/A 230/208-1 41 60 1700-.3 ESP 500 VAC1-H-D-5.0-5KW(EH/S)-2-CND-ICD2-1C-LOC 60,000 12,799 230/208-1 41 60 1700-.3 ESP 500 VAC1-H-D-5.0-10KW(EH/S)-2-CND-ICD2-1C-LOC 60,000 25,598 230/208-1 59 60 1700-.3 ESP 500 VAC1-H-D-5.0-15KW(EH/S)-2-CND-ICD2-1C-LOC 60,000 38,396 230/208-1 85 90 1700-.3 ESP 500 6 Ton s VAC1-H-D-6.0-N-2-CND-ICD2-1C-LOC 72,000 N/A 230/208-1 49 60 1800-.2 ESP 550 VAC1-H-D-6.0-5KW(EH/S)-2-CND-ICD2-1C-LOC 72,000 12,799 230/208-1 49 60 1800-.2 ESP 550 VAC1-H-D-6.0-10KW(EH/S)-2-CND-ICD2-1C-LOC 72,000 25,598 230/208-1 59 60 1800-.2 ESP 550 VAC1-H-D-6.0-15KW(EH/S) 72,000 38,396 230/208-1 85 90 1800-.2 ESP 550 SH6 316L Low Carbon Content Stainless Steel Housing The Low Carbon Content of 316 Stainless Steel Makes It Ideal for Highly Corrosive Applications. The SH6 Option Can Extend Durability and Life of Service for All Applications. MCA: Amapacity MEFC: or Breaker

VAC1 Series 208/230-3 Ph / 60 Hz 2 Ton s BTU/ HR VAC1-H-D-2.0-N-3-CND-ICD2-1C-LOC 24,000 N/A 230/208-3 15 20 800-.2 ESP 300 VAC1-H-D-2.0-6KW(EH/S)-3-CND-ICD2-1C-LOC 24,000 15,359 230/208-3 22 25 800-.2 ESP 300 2.5 Ton s BTU/ HR VAC1-H-D-2.5-N-3-CND-ICD2-1C-LOC 30,000 N/A 230/208-3 18 20 1000-.4 ESP 325 VAC1-H-D-2.5-6KW(EH/S)-3-CND-ICD2-1C-LOC 30,000 15,359 230/208-3 24 25 1000-.4 ESP 325 VAC1-H-D-2.5-9KW(EH/S)-3-CND-ICD2-1C-LOC 30,000 23,038 230/208-3 33 35 1000-.4 ESP 325 VAC1-H-D-2.5-15KW(EH/S)-3-CND-ICD2-1C-LOC 30,000 38,396 230/208-3 51 60 1000-.4 ESP 325 3 Ton s VAC1-H-D-3.0-N-3-CND-ICD2-1C-LOC 36,000 N/A 230/208-3 23 30 1100-.3 ESP 355 VAC1-H-D-3.0-6KW(EH/S)-3-CND--ICD2-1C-LOC 36,000 15,359 230/208-3 24 30 1100-.3 ESP 355 VAC1-H-D-3.0-9KW(EH/S)-3-CND-ICD2-1C-LOC 36,000 23,038 230/208-3 33 35 1100-.3 ESP 355 VAC1-H-D-3.0-15KW(EH/S)-3-CND-ICD2-1C-LOC 36,000 38,396 230/208-3 51 60 1100-.3 ESP 355 MCA: Amapacity MEFC: or Breaker

VAC1 Series 208/230-3 Ph / 60 Hz 3.5 Ton s BTU/ HR VAC1-H-D-3.5-N-3-CND-ICD2-1C-LOC 42,000 N/A 230/208-3 25 35 1400-.3 ESP 500 VAC1-H-D-3.5-9KW(EH/S)-3-CND-ICD2-1C-LOC 42,000 23,038 230/208-3 34 35 1400-.3 ESP 500 VAC1-H-D-3.5-15KW(EH/S)-3-CND-ICD2-1C-LOC 42,000 38,396 230/208-3 53 60 1400-.3 ESP 500 4 Ton s BTU/ HR VAC1-H-D-4.0-N-3-CND-ICD2-1C-LOC 48,000 N/A 230/208-3 29 40 1550-.2 ESP 500 VAC1-H-D-4.0-9KW(EH/S)-3-CND-ICD2-1C-LOC 48,000 38,396 230/208-3 34 40 1550-.2 ESP 500 VAC1-H-D-4.0-15KW(EH/S)-3-CND-ICD2-1C-LOC 48,000 46,076 230/208-3 53 60 1550-.2 ESP 500 5 Ton s VAC1-H-D-5.0-N-3-CND-ICD2-1C-LOC 60,000 N/A 230/208-3 29 40 1700-.3 ESP 500 VAC1-H-D-5.0-9KW(EH/S)-3-CND-ICD2-1C-LOC 60,000 23,038 230/208-3 34 40 1700-.3 ESP 500 VAC1-H-D-5.0-15KW(EH/S)-3-CND-ICD2-1C-LOC 60,000 38,396 230/208-3 53 60 1700-.3 ESP 500 6 Ton s VAC1-H-D-6.0-N-3-CND-ICD2-1C-LOC 72,000 N/A 230/208-3 43 50 1800-.2 ESP 550 VAC1-H-D-6.0-9KW(EH/S)-3-CND-ICD2-1C-LOC 72,000 38,396 230/208-3 43 50 1800-.2 ESP 550 VAC1-H-D-6.0-15KW(EH/S)-3-CND-ICD2-1C-LOC 72,000 46,076 230/208-3 53 60 1800-.2 ESP 550 MCA: Amapacity MEFC: or Breaker

VAC1 Series 460/480-3 Ph / 60 Hz 2 Ton s VAC1-H-D-2.0-N-4-CND-ICD2-1C-LOC 24,000 N/A 460-3 10 15 800-.2 ESP 300 VAC1-H-D-2.0-6KW(EH/S)-4-CND-ICD2-1C-LOC 24,000 18,840 460-3 12 15 800-.2 ESP 300 2.5 Ton s VAC1-H-D-2.5-N-4-CND-ICD2-1C-LOC 30,000 N/A 460-3 11 15 1000-.4 ESP 325 VAC1-H-D-2.5-6KW(EH/S)-4-CND-ICD2-1C-LOC 30,000 18,840 460-3 12 15 1000-.4 ESP 325 VAC1-H-D-2.5-9KW(EH/S)-4-CND-ICD2-1C-LOC 30,000 28,620 460-3 17 20 1000-.4 ESP 325 VAC1-H-D-2.5-15KW(EH/S)-4-CND-ICD2-1C-LOC 30,000 47,099 460-3 26 30 1000-.4 ESP 325 3 Ton s VAC1-H-D-3.0-N-4-CND-ICD2-1C-LOC 36,000 N/A 460-3 12 15 1100-.3 ESP 355 VAC1-H-D-3.0-6KW(EH/S)-4-CND-ICD2-1C-LOC 36,000 18,840 460-3 12 15 1100-.3 ESP 355 VAC1-H-D-3.0-9KW(EH/S)-4-CND-ICD2-1C-LOC 36,000 28,620 460-3 17 20 1100-.3 ESP 355 VAC1-H-D-3.0-15KW(EH/S)-4-CND-ICD2-1C-LOC 36,000 47,099 460-3 26 30 1100-.3 ESP 355 MCA: Amapacity MEFC: or Breaker

VAC1 Series 460/480-3 Ph / 60 Hz 3.5 Ton s VAC1-H-D-3.5-N-4-CND-ICD2-1C-LOC 42,000 N/A 460-3 12 15 1400-.3 ESP 500 VAC1-H-D-3.5-9KW(EH/S)-4-CND-ICD2-1C-LOC 42,000 28,620 460-3 18 20 1400-.3 ESP 500 VAC1-H-D-3.5-15KW(EH/S)-4-CND-ICD2-1C-LOC 42,000 47,099 460-3 27 30 1400-.3 ESP 500 4 Ton s VAC1-H-D-4.0-N-4-CND-ICD2-1C-LOC 48,000 N/A 460-3 14 20 1550-.2 ESP 500 VAC1-H-D-4.0-9KW(EH/S)-CND-ICD2-1C-LOC 48,000 28,260 460-3 18 20 1550-.2 ESP 500 VAC1-H-D-4.0-15KW(EH/S)-4-CND-ICD2-1C-LOC 48,000 47,099 460-3 27 30 1550-.2 ESP 500 5 Ton s VAC1-H-D-5.0-N-4-CND-ICD2-1C-LOC 60,000 N/A 460-3 15 20 1700-.3 ESP 500 VAC1-H-D-5.0-9KW(EH/S)-4-CND-ICD2-1C-LOC 60,000 28,260 460-3 18 20 1700-.3 ESP 500 VAC1-H-D-5.0-15KW(EH/S)-4-CND-ICD2-1C-LOC 60,000 47,099 460-3 27 30 1700-.3 ESP 500 6 Ton s VAC1-H-D-6.0-N-4-CND-ICD2-1C-LOC 72,000 N/A 460-3 23 30 1800-.2 ESP 550 VAC1-H-D-6.0-9KW(EH/S)-4-CND-ICD2-1C-LOC 72,000 28,260 460-3 23 30 1800-.2 ESP 550 VAC1-H-D-6.0-15KW(EH/S)-4-CND-ICD2-1C-LOC 72,00 47,099 460-3 27 35 1800-.2 ESP 550 MCA: Amapacity MEFC: or Breaker

VAC1-Series Nomenclature Guide VAC1 - H - D - 2.0 - N- 2 - CND- ICD2-1C - **** VAC1 Vertical Wall Mount Package A/C Air Flow Direction H = Horizontal Discharge Air Flow V = Vertical Discharge Air Flow Options See Options List on Page 3 ** Please Contact our Sales Department if Your Needed Option is not Listed Refrigerant Type A = R22 B = 407 C = 134A D = 410A Control Box Type 1C= General Purpose Controls 2C= Explosion Proof Controls Capacity 2.0 = 2 Tons (24,000 ) ing Capacity 10KW (EH/S) = 10 KW Electric / Standard 10KW (EH/XP) = 10 KW Electric / Explosion Proof N = No Installed Supply Voltage 2 = 208-230 / 1 / 60 Hz 2(50) = 220-240 / 1 / 50 Hz 3 = 208-230 / 3 / 60 Hz 3(50) = 220-240 / 3 / 50 Hz 4 = 460-480 / 3 / 60 Hz NEC Classification Please Contact our Sales Engineers for Classification Codes Explosion Proof Design CND = Condenser Section ONLY Explosion Proof AU = All Explosion Proof

Safe Air Technology Office Locations Safe Air Technology specializes in the engineering and manufacture of Explosion Proof, Corrosion Resistant, and Severe Duty HVAC/R systems and Pressurization Equipment. Our explosion proof, severe duty systems are designed to offer a safe solution at a competitive price. We strive to maintain the highest level of quality in both our systems and services. Safe Air Technology is headquartered in Baton Rouge, Louisiana. This allows us to easily serve many of our petrochemical, oil and gas, and industrial clients. To better serve our clients around the world, Safe Air Technology has international offices in Dubai and Singapore. Our international reach has given us the opportunity to work with clients in over 40 countries to design and deliver durable and reliable explosion proof HVAC/R systems. At Safe Air Technology, we understand that our clients HVAC/R needs are continuously adapting and changing. By forging a relationship with you, we can be better equipped to understand and meet your specific needs as they arise. Our engineering and production team takes pride in every system they deliver, from one of our standard window units to our complex custom design projects. Contact Safe Air Technology and Let Us Help to Keep Industry Safe for Your World. Safe Air Technology Safe Air Technology Safe Air Technology