Ge zoneline SinGle PackaGeD Vertical air conditioners Product Guide

Similar documents
SPACE SAVING & EFFICIENT Zoneline Single Packaged Vertical Air Conditioners

STREAMLINED & EFFICIENT

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

Zoneline vertical packaged terminal air conditioners

PRELIMINARY NEW PRODUCT GUIDE. Zoneline Packaged Terminal Air Conditioners

all-season comfort GE Zoneline packaged terminal air conditioners New product introductions Spring 2010

We bring good things to life. Zoneline. Packaged Terminal Units PRELIMINARY

Air Conditioners. Zoneline Vertical. GEAppliances.com

GE Zoneline packaged terminal air conditioners. AZ41/ contract sales architects and engineers data manual

GE zoneline. Packaged Terminal Air Conditioners

GE Zoneline packaged terminal air conditioners contract sales architects and engineers data manual

Important Safety Information. Operating Instructions The Controls on Your Zoneline Care of Product

built-in comfort GE built-in air conditioners New product introductions January 2010

Important Safety Information. Operating Instructions The Controls on Your Zoneline Care of Product

Air Conditioners. Zoneline.

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

built-in comfort GE built-in air conditioners and heat pumps

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

TECHNICAL SPECIFICATIONS

VERT-I-PAK SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONERS

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

Technical Service Guide

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

TECHNICAL SPECIFICATIONS

ARCHITECTS AND ENGINEERS DESIGN DATA MANUAL

E3EH-xxx-H Series E3EB-xxx-H Series

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

UseandCare & Installation Guide

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

RE9X Series Downflow, Upflow Electric Furnaces

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

Single Package Vertical Air Conditioners. Vert-I-Pak

Commercial High-Efficiency Condensing Units

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

Product Profile SINGLE PACKAGE VERTICAL AIR CONDITIONERS. Features

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Air ConditionersSafety Instructions

PTW 42 Series 230/208 VOLT

TECHNICAL SERVICE GUIDE

E Z S E R I E S " W X 16" H

50TM TFF COMBINATION HEATING/COOLING UNITS

Single Package Vertical Air Conditioners

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

PAJ3. Product Specifications

We bring good things to life. GE Room Air Conditioners The 1997 Line

Single Package Vertical Air Conditioners

50TM COMBINATION HEATING/COOLING UNITS

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

PACKAGE AIR CONDITIONER

High Heat COP. High/Low Stage

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Concealed Ducted Split Series R-407C MBH

INSTALLATION & OPERATION GUIDE

R 410A Ducted Horizontal Air Conditioner

room air conditioners #1 preferred brand of room air conditioners.

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

TECHNICAL SPECIFICATIONS B6VMMX

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

GREEN REFRIGERANT R-410A

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

AE/AH R410A Window Air Conditioners & Heat Pumps

R4H4. Product Specifications

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

A 14 SEER Heat Pump with R---410A Refrigerant Series

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

General Description. Operation

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

PAC series Portable Air-Cooled Spot Cooler

WALL-MOUNT HEAT PUMPS - (60HZ)

ENGINEERING SPECIFICATIONS

Service Manual A SERIES. Single Package Vertical Air Conditioning System For Years 2009 and *(Electronic Control)

SECTION 9 DOMESTIC APPLIANCES UNIT 47 ROOM AIR CONDITIONERS

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

ENGINEERING SPECIFICATIONS

Product Data. Fig. 1 - Unit 50VR -A

MAC N-407 Air-Cooled Chiller

Transcription:

GE ZONELINE SINGLE PACKAGED VERTICAL AIR CONDITIONERS Product Guide

Quiet & comfortable with Vertical zon 2

Easy to install and maintain, Zoneline Single Packaged Vertical units keep your guests cool and comfortable and your energy costs low. eline 1 SPACE-SAVING DESIGN Vertical design leaves more usable space with installation in a closet or out-of-sight area and gives rooms a more home-like feel. With proper ducting, a single unit can serve multiple rooms. 2 Efficient Zoneline units are some of the most efficient single packaged vertical units in the industry. And greater energy efficiency means lower utility bills. 3 Reliable Every component is engineered to provide exceptionally quiet and reliable cooling and heating performance for a perfectly comfortable and relaxing environment. 3

Zoneline single packaged Vertical Air Conditioner specifications AZ90 series Marketing Model AZ90E09D2C AZ90E09D3C AZ90E09D5C AZ90E12D2C AZ90E12D3C AZ90E12D5C AZ90E18D2C AZ90E18D3C AZ90E18D5C Cooling (BTUh) 9200/9000 9200/9000 9200/9000 12200/11900 12200/11900 12200/11900 17000/16800 17000/16800 17000/16800 EER (BTUh/Watt) 10.5/10.5 10.5/10.5 10.5/10.5 10.4/10.4 10.4/10.4 10.4/10.4 9.0/9.0 9.0/9.0 9.0/9.0 Voltage (V) 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 Amperage 15 20 30 15 20 30 15 20 30 Unit Width (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Depth (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Height (in.) 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 Indoor CFM* (Hi/Low) (0.1 ESP) 450/405 450/405 450/405 450/420 450/420 450/420 480/400 480/400 480/400 Minimum Clearances Front Allow 3" minimum in front of unit. AZ90E09/12/18, AZ91H09/12 Sides Allow 3" minimum on each side of unit. Platform Field-supplied; refer to installation instructions. Side-access closets Not recommended for new installations. Overall Unit Dimensions AZ90E09/12/18, AZ91H09/12: 32-1/4" H 23-1/8" W 23-1/8" D AZ91H18 AZ91H18: 47-1/4" H 23-1/8" W 23-1/8" D Specifications subject to change. 4 * Indoor CFM at 0.1 External Static Pressure

AZ91 series Marketing Model AZ91H09D2C AZ91H09D3C AZ91H09D5C AZ91H12D2C AZ91H12D3C AZ91H12D5C AZ91H18D2C AZ91H18D3C AZ91H18D5C Cooling (BTUh) 9400/9400 9400/9400 9400/9400 12200/12000 12200/12000 12200/12000 18200/18000 18200/18000 18200/18000 EER (BTUh/Watt) 10.4/10.4 10.4/10.4 10.4/10.4 10.0 10.0 10.0 10.0 10.0 10.0 Heating (BTUh) 8400/8400 8400/8400 8400/8400 11100/10900 11100/10900 11100/10900 16800/16400 16800/16400 16800/16400 COP @ 47 3.0/3.0 3.0/3.0 3.0/3.0 3.0/3.0 3.0/3.0 3.0/3.0 3.0/3.0 3.0/3.0 3.0/3.0 Voltage (V) 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 Amperage 15 20 30 15 20 30 15 20 30 Unit Width (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Depth (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Height (in.) 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 47-1/4 47-1/4 47-1/4 Indoor CFM* (Hi/Low) 450/420 450/420 450/420 450/420 450/420 450/420 450/400 450/400 450/400 AZ91 series Marketing Model AZ91H09E2C AZ91H09E3C AZ91H09E5C AZ91H12E2C AZ91H12E3C AZ91H12E5C AZ91H18E2C AZ91H18E3C AZ91H18E5C Cooling (BTUh) 9400 9400 9400 12400 12400 12400 18000 18000 18000 EER (BTUh/Watt) 10.3 10.3 10.3 10.0 10.0 10.0 10.0 10.0 10.0 Heating (BTUh) 8500 8500 8500 11300 11300 11300 16500 16500 16500 COP @ 47 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 Voltage (V) 265 265 265 265 265 265 265 265 265 Amperage 15 20 30 15 20 30 15 20 30 Unit Width (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Depth (in.) 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 23-1/8 Unit Height (in.) 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 47-1/4 47-1/4 47-1/4 Indoor CFM* (Hi/Low) 450/420 450/420 450/420 450/420 450/420 450/420 450/400 450/400 450/400 Specifications subject to change. 5

ZONELINE PARTS & accessories RAVAL2 Aluminum outdoor Grill AZ90/91 RAVWPT8 Telescoping Wall Plenum 5-1/2" - 8" RAVWPT14 Telescoping Wall Plenum 8" - 14" RAVDP18 Drain Pan Kit 18,000 large chassis Az91 RAVRG1 Access Panel with return air grill for SMALL CHASSIS AZ90/91 RAVRG2 Return Air Grill RAVRG3 Access Panel with return air grill for large chassis AZ91 RAVTRANS Transition piece for replacement of EXISTING GE APPLIANCES VERTICAL WITH new az90/91 ZONELINE thermostats AZ90 Series RAK164D2 Cooling with Electric Heat Digital Remote Thermostat 24V AC digital remote wall thermostat with single-stage cooling and single-stage heating for resistance heat models Requires 5-wire hookup RAK164F2 DIGITAL TWO FAN SPEED THERMOSTAT FOR ELECTRIC RESISTANCE Two fan speeds 24V AC digital remote wall thermostat with single-stage cooling and single-stage heating for resistance heat models Requires 6-wire hookup RAK164P2 Cooling with Electric Heat Programmable Remote Thermostat 24V AC programmable remote wall thermostat with single-stage cooling and single-stage heating for resistance heat models Programmable for 7-day or 5+2-day programs Requires 5-wire hookup AZ91 Series RAK148D2 Heat Pump Digital Remote Thermostat 24V AC digital remote wall thermostat with single-stage cooling and 2-stage heating for heat pump models Requires 6-wire hookup 6 RAK148F2 DIGITAL TWO FAN SPEED THERMOSTAT FOR HEAT PUMP Two fan speeds 24V AC digital remote wall thermostat with single-stage cooling and 2-stage heating for heat pump models Requires 7-wire hookup RAK148P2 Heat Pump Programmable Remote Thermostat 24V AC programmable remote wall thermostat with single-stage cooling and 2-stage heating for heat pump models Programmable for 7-day or 5+2-day programs Requires 6-wire hookup

Zoneline single packaged vertical unit nomenclature The Vertical Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features included on the unit. When specifying or ordering the Zoneline chassis, use of this nomenclature will ensure receiving the correct unit. A Z 9 1 H 1 2 D 3 c Zoneline Chassis series 90=electric resistance single packaged vertical unit 91= heat pump single packaged vertical unit Nominal cooling capacity 09=9,000 BTUh cooling 12=12,000 BTUh cooling 18=18,000 BTUh cooling Heater wattage/ Amps 2= 2.4 kw; 15 amp 3=3.4 kw; 20 amp 5=5.0 kw; 30 amp Unit type E= cooling with electric resistance heat H= heat pump with electric resistance heat Voltage/Phase/Frequency D= 230/208 Volt, single phase, 60 Hz E= 265 Volt, single phase, 60 Hz Special features C=Corrosion treated Visit Zoneline.com for more information. Zoneline single packaged vertical unit warranty For the period of one year From the date of the original purchase GE Appliances will replace Any part of the air conditioner which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE Appliances will provide, free of charge, all labor and related service costs to replace the defective part. five years From the date of the original purchase Sealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor, condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or workmanship. During this limited five-year warranty, GE Appliances will provide, free of charge, all labor and related service costs to replace the defective part. second through fifth year From the date of the original purchase Fan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload, Solenoids, Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in materials or workmanship. During this additional four-year limited warranty, the customer will be responsible for any labor and related service costs. 7

GE is a trademark of the General Electric Company. Manufactured under trademark license. Appliance Park Louisville, KY 40225 geappliances.com zoneline.com 888.231.2548 Pub. No. 20-S0027-1 PC88082