Technical Specification VFD

Similar documents
3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

PILOT VALVE ENCLOSURES

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

standards: standards:

Technical Specification

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Description. Applications

INSTRUCTION & SERVICE MANUAL

OPTIBAR DP 7060 Supplementary Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION & SERVICE MANUAL

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Centro-Matic Automated Lubrication Systems System Controls

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Certificate of Compliance

LTFX Electric Tank Immersion Heaters Installation Instructions

Introduction to Flow Switch

Certificate of Compliance

Dräger Polytron 5100 EC Detection of toxic gases and vapors

FX5 Series Explosion-Proof Electric Air Heaters

Technical Data. Dimensions

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Performance Data. curus Component Recognized; File No. E IP 20

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Ultrasonic Point Level Switches

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Ultrasonic Switches. Features & Benefits

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Dräger Polytron 5700 IR Detection of flammable gases and vapours

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Technical Data. Dimensions

Monitored Pneumatic Valves On Series Ported Manifold

Circulation Heaters Selection Guidelines

Hazardous Area Telephone Model EP600

Dräger Polytron 5100 EC Detection of toxic gases and vapors

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Commercial/Industrial Combustion Control Level Three Announcement

Enclosure Heaters and Fan Heaters

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

FE1 Explosion-Proof Electric Air Heaters

INTRODUCTION / TABLE OF CONTENTS

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Annubar Flowmeter Series

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Circulation Heaters Selection Guidelines

CR 027 PTC Fan Heater W

Installation Instructions for W2H Series Signals

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

½ Monitored Pneumatic Valves On Series Ported Manifold

Enraf Servo Gauge 854 XTG

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Field Certification Certificate of Compliance

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

TRASCO ATEX Couplings

SET-2000 Hi Level/Oil

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Technical Manual for the Strobe - SM87 HXB

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

4) Intrinsic Safety Certification

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Description. Applications

Technical Data. Dimensions

Dräger Polytron 5720 IR Toxic Gas Detection

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

Guide for hazardous areas

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

ULTRA-SAFE Explosion-proof Duct Heaters

Powers Controls Low Temperature Detection Thermostat

Compressed air treatment. Condensate drains OMEGA AIR

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Flange immersion heaters

EJB Custom-Built Control Panels

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

INTRODUCTION / TABLE OF CONTENTS

VERSAFLOW VORTEX Supplementary instructions

Plug-in Base, Long Range Sensor E3B2

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

ULTRA-SAFE Explosion-proof Duct Heaters

Transcription:

Technical Specification - 3-6 VFD Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain both flame and the ignition of dust and gas clouds and any accumulated layers of dust. 3-6VFD Combination Flame and Explosion Proof Pilot Valve Enclosures Diecast aluminium enclosure with explosion proof (Ex-e) and flame proof (Ex-d) protection suitable for use in hazardous areas, available optionally with anti-condensation heater. In Canada and Europe Goyen offers enclosures that meet the requirements of both flame proof and explosion proof type designs simultaneously. This has the advantage of simplifying assembly designs when using the Goyen enclosures. Suitable for NEC500 Division 1, NEC505 Zone 1 and ATEX Zone 20 and 21 (II Cat 2G & 2D equipment) hazardous environments, for piloting Goyen diaphragm valves. Construction Body: Al 2011-T3 Pilot body: Al 2011-T3 Ferrule: AISI 302 SS Armature: 430FR SS Seals: Nitrile Screws: AISI 302 SS Clips: Plated mild steel Maintenance Annual maintenance of serviceable parts is recommended. Serviceable items are the pilot armature, armature spring, pilot valve body o-ring. The same model Goyen coil may also replace damaged coils. All other items are non-serviceable. Goyen recommend that appropriately qualified personnel conduct all maintenance activities. Certification of maintenance staff and facilities may be required under some certification schemes. Inappropriate service invalidates the product certifications. Operation Recommended on time: On time range: Recommended time between pulses: Pilot Performance Flow: Maximum Working Pressure: Minimum Working Pressure: Minimum Temperature: Maximum Temperature: Fluid Media: 50-150ms 50-500ms 1 minute or more, if maximum on time is used. 0.27 Kv/0.32 Cv 860 kpa/125 psi 0 kpa/0 psi -40 o C/-40 o F 82 o C/-180 o F Air or inert gas Copyright by Tyco International Ltd. TS-3-6VFD/SEP/05

Technical Specification - 3-6 VFD Restrictions This product's hazardous areas certifications are valid only for product that has not been modified since leaving the factory. Modifications made to the enclosure such as the fitment of additional gaskets, the addition or removal of pilot valves and coils, changes in markings, or physical modifications made to the enclosure itself will invalidate the product certifications. Only activities described in 'Installation' and 'Maintenance' may be conducted without affecting the certification of the product. Installation WARNING: Ensure that power is isolated from the system prior to installing or opening this product. Where a heater kit is installed, ensure that the heater has been de-energised for a minimum of 5 minutes prior to opening the enclosure. Ensure that the enclosure is properly assembled with all flange screws fully tightened (minimum 10Nm (7.4 ft.lbs)) prior to applying power in a hazardous area. Mounting Enclosures should be mounted in a horizontal position, where the pilot valves and solenoid assemblies are in the preferred vertical orientation. Threads Pilot valve inlet and exhaust outlets are offered in both 1/8" BSPP (Rp) and NPT. The enclosure base has one conduit entry with either M25 or 3/4" NPT thread. Electrical connections Refer to diagram below. The included Goyen QT2 solenoids are provided with screw/spade terminals. These solenoids are neutrally linked at the factory for customer convenience. Product Certifications and Markings CSA Without heater * LR26709 Class I Nema 7 Class II Groups E, F and G Nema 9 Temp Code T4 * Heater kit is not certified for use with this enclosure ATEX Without heater Ex II 2GD CE 0518 EEx d IIB T6/T3 IP6X T85 o C/T192 o C (T192ºC WITH HEATER FITTED) SIRA 02ATEX1408 DATE XX/XX/XX Product warning labels Pneumatic connections These pilot valves are connected to the dust collector reverse pulse jet valves using metric 4mm tubing (ID 0.157") or imperial ¼" tubing (ID 0.162") and maximum length of 1.5m (4.9 ft). Solenoid Performance Voltage Inrush Hold Power Current ma Current ma 220/240 50/60 Hz 148/143 105/94 23.1 VA 100/120 50/60 Hz 234/255 180/152 19.8 VA 24 VDC 873 873 20 W CSA CAUTION: open circuit before removing cover ATTENTION: ouvrir le circuit avant d'enlever le couvercle WARNING: more than one live circuit. see diagram. AVERTISSEMENT: cet equipement renferme plusieurs circuits sous tension. voir le schema ATEX Warning do not open whilst energised, do not open when explosive atmosphere is present. Use cables rated at 135 o C when anticondensation heater is installed. Copyright by Tyco International Ltd. TS-3-6VFD/SEP/05

Technical Specification - 3-6 VFD Anti-Condensation Heater Elements According to model specification number, this enclosure type may be factory fitted with a heater element to assist in the prevention of condensation within the enclosure. Heater ratings Voltage Watts 24VDC 48 110/120VAC 100 220/240VAC 100 Note that heater voltage matches solenoid voltages. Heater terminal block connections 1. Heater retaining clip 3. Wiring terminal block 2. Heater element 4. Thermostat element Spare Parts K0380: Single armature kit. includes spring, armature and o-ring G604490: Flange gasket Order Codes Each individual enclosure configuration is controlled under a unique specification number in accordance with the product's Certification. The list below only represents a portion of the legally configurable Goyen 3-6V ranges. Please contact your Goyen representative if you require a configuration not represented here. Pilot Conduit Spec. No* Fitted Thread Thread UL Cert. Pilots Voltage Heater (NPT) (NPT) 4T4/2766* 4 100/120VAC No 1/8" 3/4" 4T4/2780* 4 220/240VAC No 1/8" 3/4" 4T4/2781* 4 24VDC No 1/8" 3/4" 4T4/2846* 4 100/120VAC No 1/8" 3/4" 4T4/3228* 4 100/120VAC No 1/8" 3/4" 5T4/2767* 5 100/120VAC No 1/8" 3/4" 5T4/2783* 5 220/240VAC No 1/8" 3/4" 5T4/2784* 5 24VDC No 1/8" 3/4" 6T4/2768* 6 100/120VAC No 1/8" 3/4" 6T4/2786* 6 220/240VAC No 1/8" 3/4" 6T4/2787* 6 24VDC No 1/8" 3/4" 6T4/2845* 6 100/120VAC No 1/8" 3/4" 6T4/3229* 6 100/120VAC No 1/8" 3/4" Spec. No* Fitted Pilot Conduit ATEX Cert. Pilots Voltage Heater Thread Thread 4T6/3427 4 100/120VAC No Rp 1/8 M25 4T6/3428 4 220/240VAC No Rp 1/8 M25 4T6/3429 4 24VDC No Rp 1/8 M25 5T6/3430 5 100/120VAC No Rp 1/8 M25 5T6/3431 5 220/240Vac No Rp 1/8 M25 5T3/3438 5 220/240Vac Yes Rp 1/8 M25 5T6/3432 5 24VAC No Rp 1/8 M25 5T3/3437 5 24VAC Yes Rp 1/8 M25 6T6/3433 6 100/120VAC No Rp 1/8 M25 6T6/3434 6 220/240VAC No Rp 1/8 M25 6T6/3442 6 220/240VAC Yes Rp 1/8 M25 6T6/3435 6 24VDC No Rp 1/8 M25 Notes: (1) Heater kit not available for CSA 3-6VFD enclosures. (2) These enclosures are dual rated Ex-d and Ex-e. Please Note: When ordering, add the enclosure number to the beginning of the specification number, e.g. 3-6VFD4T4/2766. *No Goyen label on product. Copyright by Tyco International Ltd. TS-3-6VFD/SEP/05

Technical Specification - 3-6 VFD Dimensions (in mm (inches)) Weight Mass = 2.24 Kg + 0.08 Kg per fitted pilot (4.94 lbs + 0.18 lbs per fitted pilot) Copyright by Tyco International Ltd. TS-3-6VDFD/SEP/05

Technical Specification - 3-6 VFP Pilot valve enclosures suitable for use in hazardous certified environments. These enclosures are designed and tested to contain an explosion. 3-6VFP Flame Proof Enclosure Diecast aluminium enclosure with flame proof (Ex-d) protection suitable for use in hazardous areas, available optionally with anticondensation heater. These enclosures are designed and tested to contain an explosion. The main hazard is a potentially explosive gas/air mixture that may exist within the enclosure. This enclosure contains the explosion and quenches the flame. Flame path width and gaps to the exterior are designed to cool the burning gases to prevent the ignition of the surrounding atmosphere. This protection concept is sometimes referred to as Ex-d. Suitable for NEC500 Division 1, NEC505 Zone 1 hazardous environments, for piloting Goyen diaphragm valves. Construction Body: Al 2011-T3 Pilot body: Al 2011-T3 Ferrule: AISI 302 SS Armature: 430FR SS Seals: Nitrile Screws: AISI 302 SS Clips: Plated mild steel Maintenance Annual maintenance of serviceable parts is recommended. Serviceable items are the pilot armature, armature spring, pilot valve body o-ring. The same model Goyen coil may also replace damaged coils. All other items are non-serviceable. Goyen recommend that appropriately qualified personnel conduct all maintenance activities. Certification of maintenance staff and facilities may be required under some certification schemes. Inappropriate service invalidates the product certifications. Operation Recommended on time: On time range: Recommended time between pulses: Pilot Performance Flow: Maximum Working Pressure: Minimum Working Pressure: Minimum Temperature: Maximum Temperature: Fluid Media: 50-150ms 50-500ms 1 minute or more, if maximum on time is used. 0.27 Kv/0.32 Cv 860 kpa/125 psi 0 kpa/0 psi -40 o C/-40 o F 82 o C/-180 o F Air or inert gas Copyright by Tyco International Ltd. TS-3-6VFP/SEP/05

Technical Specification - 3-6 VFP Restrictions This product's hazardous areas certifications are valid only for product that has not been modified since leaving the factory. Modifications made to the enclosure such as the fitment of additional gaskets, the addition or removal of pilot valves and coils, changes in markings, or physical modifications made to the enclosure itself will invalidate the product certifications. Only activities described in 'Installation' and 'Maintenance' may be conducted without affecting the certification of the product. Installation WARNING: Ensure that power is isolated from the system prior to installing or opening this product. Where a heater kit is installed, ensure that the heater has been de-energised for a minimum of 5 minutes prior to opening the enclosure. Ensure that the enclosure is properly assembled with all flange screws fully tightened (minimum 10Nm (7.4 ft.lbs)) prior to applying power in a hazardous area. Mounting Enclosures should be mounted in a horizontal position, where the pilot valves and solenoid assemblies are in the preferred vertical orientation. Threads Pilot valve inlet and exhaust outlets are offered in both 1/8" BSPP (Rp) and NPT. The enclosure base has one conduit entry with either M25 or 3/4" NPT thread. Electrical connections Refer to diagram below. The included Goyen QT2 solenoids are provided with screw/spade terminals. These solenoids are neutrally linked at the factory for customer convenience. 3-6VFP Product Certifications and Markings UL With heater Without heater Listed 823N Listed 823N Class 1 Class 1 Nema 7 Nema 7 Op. Temp Code T3 Op. Temp Code T6 CSA With heater Without heater LR26709 LR26709 Class 1 Class 1 Nema 7 Nema 7 Temp Code T2C Temp Code T4 SAA With heater Ex d IIB T3 IP65 Aus Ex 1220X Without heater Ex d IIB T5 IP65 Aus Ex 1220X Product warning labels Pneumatic connections These pilot valves are connected to the dust collector reverse pulse jet valves using metric 4mm tubing (ID 0.157") or imperial ¼" tubing (ID 0.162") and maximum length of 1.5m (4.9 ft). Solenoid Performance Voltage Inrush Hold Power Current ma Current ma 220/240 50/60 Hz 148/143 105/94 23.1 VA 100/120 50/60 Hz 234/255 180/152 19.8 VA 24 VDC 873 873 20 W UL WARNING to prevent ignition of hazardous atmospheres disconnect all supply of circuits before opening enclosure. keep tightly closed when in operation. CSA CAUTION: open circuit before removing cover SAA (enclosures with heaters) WARNING: do not open enclosure whilst energised. isolate elsewhere and allow a minimum of 5 minutes after heater is de-energised before removing cover. SAA (enclosures without heaters) WARNING: do not open enclosure whilst energised. isolate elsewhere before removing cover. Copyright by Tyco International Ltd. TS-3-6VFP/SEP/05

Technical Specification - 3-6 VFP Anti-Condensation Heater Elements According to model specification number, this enclosure type may be factory fitted with a heater element to assist in the prevention of condensation within the enclosure. Heater ratings Voltage Watts 24VDC 48 110/120VAC 100 220/240VAC 100 Note that heater voltage matches solenoid voltages. Heater terminal block connections 1. Heater retaining clip 3. Wiring terminal block 2. Heater element 4. Thermostat element Spare Parts K0380: Single armature kit. Includes spring, armature and o-ring. Order Codes Each individual enclosure configuration is controlled under a unique specification number in accordance with the product's Certification. The list below only represents a portion of the legally configurable Goyen 3-6V ranges. Please contact your Goyen representative if you require a configuration not represented here. Pilot Conduit Spec. No* Fitted Thread Thread UL Cert. Pilots Voltage Heater (NPT) (NPT) Pilot Conduit Spec. No* Fitted Thread Thread CSA Cert. Pilots Voltage Heater (NPT) (NPT) 4T3/2678* 4 100/120VAC Yes 1/8" 3/4" 4T3/2719 4 100/120VAC Yes 1/8" 3/4" 4T3/2930* 4 24VDC Yes 1/8" 3/4" 4T6/2398* 4 100/120VAC No 1/8" 3/4" 4T3/3275 4 220/240VAC Yes 1/8" 3/4" 4T6/2615 4 220/240VAC No 1/8" 3/4" 4T6/2754* 4 24VDC No 1/8" 3/4" 4T6/3040 4 24VDC No 1/8" 3/4" 4T6/3041 4 100/120VAC No 1/8" 3/4" 5T3/2898* 5 100/120VAC Yes 1/8" 3/4" 5T3/2929* 5 24VDC Yes 1/8" 3/4" 5T6/2397* 5 100/120VAC No 1/8" 3/4" 5T6/2496* 5 24VDC No 1/8" 3/4" 5T6/2882 5 24VDC No 1/8" 3/4" 5T3/3303 5 220/240VAC Yes 1/8" 3/4" 5T6/2923 5 220/240VAC No 1/8" 3/4" 5T6/3039 5 100/120VAC No 1/8" 3/4" 6T3/2396 6 100/120VAC Yes 1/8" 3/4" 6T3/2928* 6 24VDC Yes 1/8" 3/4" 6T3/3107* 6 100/120VAC Yes 1/8" 3/4" 6T6/2517* 6 100/120VAC No 1/8" 3/4" 6T6/2614 6 220/240VAC No 1/8" 3/4" 6T6/2753* 6 24VDC No 1/8" 3/4" 4T2C/2856* 4 100/120VAC Yes 1/8" 3/4" 4T2C/2927* 4 24VDC Yes 1/8" 3/4" 5T2/2901* 5 100/120VAC Yes 1/8" 3/4" 5T2C/2926* 5 24VDC Yes 1/8" 3/4" 6T2C/2809* 6 100/120VAC Yes 1/8" 3/4" 6T2C/2925* 6 24VDC Yes 1/8" 3/4" Spec. No* Fitted Pilot Conduit SAA Cert. Pilots Voltage Heater Thread Thread 4T6/2393 4 100/120VAC No Rp 1/8 M25 4T6/2670 4 24VAC No Rp 1/8 M25 4T6/2671 4 220/240VAC No Rp 1/8 M25 4T6/2849 4 100/120VAC No Rp 1/8 M25 4T6/3143 4 24VDC No Rp 1/8 M25 5T6/2392 5 220/240VAC No Rp 1/8 M25 5T6/2850 5 100/120VAC No Rp 1/8 M25 5T6/3142 5 24VDC No Rp 1/8 M25 5T6/3182 5 100/120VAC No Rp 1/8 M25 6T6/2563 6 100/120VAC No Rp 1/8 M25 6T6/2608 6 24VDC No Rp 1/8 M25 6T6/3361 6 220/240VAC No Rp 1/8 M25 Please Note: When ordering, add the enclosure number to the beginning of the specification number, e.g. 3-6VFP4T6/2393. *No Goyen label on product Copyright by Tyco International Ltd. TS-3-6VFP/SEP/05

Technical Specification - 3-6 VFP Dimensions (in mm (inches)) Weight Mass = 2.21 Kg + 0.08 Kg per fitted pilot (4.87 lbs + 0.18 lbs per fitted pilot) Copyright by Tyco International Ltd. TS-3-6VFP/SEP/05