PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

Similar documents
PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

PSE-805A. AL4000 SERIES 100mm chart PEN HYBRID MEMORY RECORDER

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

SHIMADEN DIGITAL INDICATORS

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Process & TeMPerATUre UniversAl input DigiTAl MeTers

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

MICROJET RECORDER (24-CHANNEL 180mm)

UDC100 Universal Digital Controller Specifications

MICROJET RECORDER (180mm)

MICROJET RECORDER (180mm)

Temperature Controllers

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Specification , July 2015

Universal controller for panel mounting Models CS6S, CS6H, CS6L

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

TEMPERATURE CONTROLLER

Series Digital Controller Instruction Sheet

I/A Series 716C 1/16 DIN Temperature Controller

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Series Temperature Controller Instruction Sheet

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

UDC 700 Universal Digital Controllers and Indicator Specifications

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Advanced Test Equipment Rentals ATEC (2832)

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User s. Manual) Model VJUK Limit Alarm for Universal Input

KH SERIES (PEN-WRITING SYSTEM)

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

02/11/2015

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

CTT8 TEMPERATURE MONITOR DEVICE

Option output. 0 None. 4 RS485 communication output. 0 None. Alarm output. CH2 control output. 0 None. CH1 control output. 0 None

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

02/11/2015

MO n : 12JMC rév A

Specifications Minimum Typical Maximum Unit

Example of Applications and Parameter Functions

SR70 (SR ) Series Digital controller Instruction Manual

TEMPERATURE CONTROL MODULE MODEL R3-TC2

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Compact Ultra Low Temperature Chamber

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Series Multipoint Recorder. Features. The future in Data Recording Technology is available today

RTD TEMPERATURE SENSING SYSTEM

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Model 1062 Environment Monitor

FAHM Co. Temperature Transmitter PTT74 Series

IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

EC3-X33 Stand-alone Superheat Controller Technical Data

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

RS485 MODBUS Module 8AI

Hardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC.

Nov 08 PRODUCT SPECIFICATION SHEET

JW SERIES. Three Phase Thyristor Regulator PSE-351

EL-USB-TC Thermocouple Data Logger with USB Interface

Temperature Controller

E5CN/E5CN-U (48 x 48 mm)

ELMTEC. Kattreppeln Königslutter / /

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Universal Input Digital Panel Meter With Bargraph, NA3

Analog Input Module IC670ALG630

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

APPLICATION DATA SHEET

Infrared port USB. Control Output 2. (built-in) SSR outputs

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Bulletin 900-TC. Bulletin 900 TC Temperature/Process Controllers. Certifications. Bulletin 900-TC8 Controller Models

GCS-300 No.GCS31E

MR SERIES CARD LOGGERS

Point recorder KS 3660

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

TC515 and TC600 Installation Manual. a Winters company

Model 144H. Product Data Sheet , Rev DB February Content

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

EL-USB-1-LCD Temperature Data Logger with LCD

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Programmable Temperature Controller (Digital Controller)

EasyLog Data Logger Series

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Transcription:

KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER KL4000 Series hybrid recorders realize simple and easy operation as analog recorders. Not only can each measured value be read from the custom made analog scale plate which incorporates input type and measurement value input, but a comprehensive LED display also enables precise digital measurements to be taken by the user. FEATURES Dual displays for accuracy and simplicity Measured value can be read at a glance, directly from the triple scale analog display plate while a digital display clearly indicates measured values. Ready to run immediately after Power ON As the recorders are pre-set to meet individual customer specifications and precise application requirements, the unit starts indicating and recording as soon as they are Power ON. Front section USB port provided Connect with PC by mini-usb cable.* By attached setting software, you can set or change the parameter by PC. *Purchase commercialized product separately. Corresponds to custom-made In addition to easy to use features, we will correspond to adding various devices and special features according to user s requirement. Packaged Software attached. By Data acquisition software, the use of application is expands from recording/management to information processing. *Optional communication interface is required.. Parameter setting software can manage the setting information on PC. MODELS KL4- Input signal 1:Thermocouple/DC voltage single range 2:Resistance thermometer single range 5:Thermocouple/DC voltage individual range 6:Resistance thermometer/ thermocouple/dc voltage individual range Input point 06 : 6 points Communication interface (option) N:None R:RS232C A:RS422A/RS485 Alarm output / remote contacts (option) 0:None 2:Mechanical relay 2 points ( a contact) 4:Mechanical relay 4 points ( c contact) + remote contact 5 points A:Mechanical relay 6 points ( a contact) + remote contact 5 points Power supply A:100-240V AC PSE-369A

KL4000 SERIES NAME Scale plate Pointer Display CH.No. Display DATA Operation/Setting Key Engineering port (USB communication connector) Display and operation keys [Display] CH.No. Channel number of analog indication and data display (data display only for one-point continuous display) * DATA Data or time display* *Set contents are displayed while in [Setting mode]. [Status LED] REC ALM Green light lights during recording. Operation of recording ON/OFF is done by REC key. Flashes when chart end. ALM Red light blinks during alarm activation. [Operation/set key] Key names Function FEED Feed key Feeds chart at a speed of 600mm/min while this key is pressed. MODE Mode key Switches mode. SEL Select key Selects item to be set. Down key Moves the cursor up/down. Up key Selects setting items or values. ENT Enter key Registers various settings.

RECORDING EXAMPLE Periodic data printing and fixed time printing Prints data(time, scale, chart speed periodic, setting change mark and printing of time line) on trace printing at arbitrary set intervals. Chart speed Scale Scale Time Time line Digital recording CH. No. Trace printing Data printing When the latest data is required, trace printing will stop and record. Time Digital recording Trace printing Alarm activation and reset printing When an alarm activation and reset occurred, its time, CH No, alarm type and level are printed. Alarm reset time Alarm reset CH No. Level (alarm points No.) Time printing Level (alarm points No.) Alarm type Alarm activation CH No. Alarm activation time

KL4000 SERIES INPUT SPECIFICATIONS Measuring points: 6 Input types: DC voltage --- ±±± ±± DC current --- Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately) Thermocouple --- K, E, J, T, R, S, B, N, U, L, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel Resistance thermometer --- Pt100, old Pt100, JPt100, Pt50, Pt-Co Accuracy ratings: Refer to the tables of measurement range, accuracy ratings and display resolution Measuring interval:5sec./6points Reference junction compensation accuracy: At ambient temperature:23±10 K, E, J, T, N Platinel --- ±0.5 or equivalent of 20µV, whichever is greater Other than above --- ±1.0 or equivalent of 40µV thermal electromotive force, whichever is greater Burnout: For thermocouple input and resistance thermometer input this function detects input signal disconnection. For thermocouple, resistance thermometer this function enables selection of NON/UP/DOWN for each input CH Terminal board: Removable when wiring. RECORDING SPECIFICATIONS Dotting interval: About 5sec./1point Recording system: Wire-dot type 6-color ribbon Record/Printed color: Trace printing CH 1 2 3 Color Red Black Blue CH 4 5 6 Color Green Brown Purple Digital recording Chart paper: Chart speed: Periodic data printing Alarm printing Repetition of six colors; red, black, blue, green, brown and purple Activate: Red, Reset: Green Black (individual channel items use List printing same colors as trace printing) Fan-fold type Total width 114mm, total length 10m, effective chart width 100mm From 1 to 1500mm/h, in 1mm/h increments. (12.5mm can be set exceptionally.) Periodic data printing: Digital printing is added to trace printing as time, channel no., data, and unit. Interval (hour, minute) arbitrary setting Data printing: When required, interrupt trace printing and digital print time and measuring value. Alarm printing: Alarm activated --- Time, CH No, alarm type List printing: Subtract printing: Alarm reset --- and level are printed Time, CH No. and alarm level are printed Memory capacity --- Max. of 48 data When required, interrupt trace printing and print date, chart speed and setting information of each channel. *Optional remote contacts is required. Difference between reference CH value and measured value or between set value and measured value (set by provided software) Fixed time printing:date (month/day), time and time line, scale, CH No. tag and unit are printed in conjunction with the chart speed. Skip function: No display or printing of channels that are not inputted. DISPLAY AND INDICATION SPECIFICATIONS Analog display: Digital display: Status display: 100mm scale plate 7-segment type red LED, CH No, 2 digits and data display, 5 digits REC, ALM ALARM SPECIFICATIONS Alarm display: Alarm types: Alarm settings: Alarm output: Status LED ALM flashes, Absolute upper/lower alarm, differential upper/lower alarm, rate-of-change upper/lower alarm Each points individual settings, Max 2 levels/1 CH Mechanical relay a contact 2 or 6points output Mechanical relay c contact 4points output GENERAL SPECIFICATIONS Rated power voltage: 100 to 240V AC, 50/60Hz Power consumption: Max 38VA 100VAC balanced 17VA, 240VAC balanced 23VA Normal operation condition: Ambient temperature range : 0 to 50 C (20 to 60%RH no dew condensation) Ambient humidity range: 20 to 80%RH, (5 to 45 C) no dew condensation Power voltage : 90 to 264V AC Power frequency : 50/60Hz ±2% Mounting orientation : forward tilting 0, backward tilting 0 to 30, left/right 0 to 10 Case material: Case color: Door---Aluminum die casting (ADC12) Front plate---soda glass Case---Steel (SPCC) Door frame---black (equivalent to Munsell N3.0 ) Front plate---clear and colorless Case---Gray (equivalent to Munsell N7.0 ) Mounting method: Panel flush-mount Weight: About 3.0kg (full option) STANDARDS CE marking: UL: CSA (C-UL): EN61326-1 EN61010-1 *Under EMC test condition, variation in indication value is ±20% or ±2mV at maximum, whichever is larger. UL61010-1 CAN/CSA C22.2 No.61010-1 OPTIONS Other manufacture's chart paper corresponding type Handle and feet ACCESSORIES Shunt resistor for DC current 100Ω Model : EZ-RX100 (Max.50mA) 250Ω Model : EZ-RX250 (Max.20mA)

MEASURING RANGES/ACCURACY RATING/DISPLAY RESOLUTION DC voltage Thermocouple RTD Input type Measuring range Accuracy ratings mv V K E J T R S B N U L W-WRe26 WRe5-WRe26 NiMo-Ni Platinel PtRh40-PtRh20 CR-AuFe Pt100 Old Pt100 JPt100 Pt50 Pt-Co -6.9 to 6.9mV -13.8 to 13.8mV -27.6 to 27.6mV -69.0 to 69.0mV -5 to 5 V -150 to 150ºC -200 to 600ºC -200 to 1370ºC -200 to 350ºC -200 to 900ºC -200 to 500ºC -200 to 1200ºC -150 to 150ºC -200 to 250ºC -200 to 400ºC 0 to 1760ºC 0 to 1760ºC 0 to 1820ºC -200 to 200ºC -200 to 400ºC -200 to 750ºC -200 to 1300ºC -150 to 150ºC -200 to 250ºC -200 to 500ºC -200 to 600ºC -200 to 500ºC -200 to 900ºC 0 to 2315ºC 0 to 2315ºC 0 to 1310ºC 0 to 150ºC 0 to 350ºC 0 to 650ºC 0 to 1390ºC 0 to 1880ºC 0 to 280 K -50 to 50ºC -100 to 100ºC -140 to 150ºC -50 to 50ºC -100 to 100ºC -140 to 150ºC -50 to 50ºC -100 to 100ºC -140 to 150ºC 4 to 374 K ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2% ±0.15% Display resolution 5µV 10µV 10µV 10µV 10mV 0.1K 0.1K Note: The accuracy ratings are converted into the measuring range under reference condition. Thermocouple input does not contain reference junction compensation accuracy. K, E, J, T, R, S, B, N : IEC584(1977, 1982), JIS C 1602-1995, JIS C 1605-1995 W-WRe26, NiMo-Ni, Platinel, PtRh40-PtRh20, CR-AuFe, Au/Pt : ASTM E1751 WRe5-WRe26 : ASTM E988 U, L : DIN43710-1985 Pt100 : IEC751(1995), JIS C 1604-1997 Old Pt100 : IEC751(1983), JIS C 1604-1989, JIS C 1606-1989 JPt100 : JIS C 1604-1981, JIS C 1606-1986, Pt50 : JIS C 1604-1981 Pt-Co : CHINO STANDARD SCALE LIST Thermocouple RTD Input type DC voltage & DC current K E J T R S B N PR20-40 PR5-20 Ni-NiMo Platinel U L Pt100 JPt100 Pt50 Standard scale -5 to 5mV, 0 to 5mV -10 to 10mV, 0 to 10mV 0 to 20mV 0 to 50mV 1 to 5V, 4 to 20mA, 10 to 50mA 0 to 100ºC, 0 to 15ºC, -50 to 100ºC 0 to 200ºC, 0 to 250ºC, 0 to 300ºC 0 to 800ºC, 0 to 1000ºC, 0 to 1200ºC 0 to 200ºC, 0 to 300ºC, -50 to 150ºC 0 to 500ºC, 0 to 600ºC, 0 to 800ºC 0 to 300ºC, 0 to 400ºC, 0 to 600ºC, 0 to 800ºC, 0 to 1000ºC 0 to 100ºC, 0 to 150ºC, -50 to 100ºC 0 to 200ºC, 0 to 250ºC, -50 to 200ºC 0 to 300ºC, 0 to 400ºC 0 to 1200ºC, 0 to 1400ºC, 0 to 1600ºC 0 to 1400ºC, 0 to 1600ºC, 400 to 1600ºC 0 to 1200ºC, 0 to 1400ºC, 0 to 1600ºC 0 to 150ºC0 to 200ºC 0 to 300ºC 0 to 1000ºC, 0 to 1200ºC 0 to 1600ºC 0 to 1200ºC0 to 1400ºC, 0 to 1600C 0 to 800ºC, 0 to 1000ºC, 0 to 1200ºC 0 to 100ºC, 0 to 150ºC, -50 to 100ºC 0 to 200ºC, 0 to 250ºC, 0 to 300ºC 0 to 800ºC, 0 to 1000ºC, 0 to 1200ºC 0 to 100ºC, 0 to 150ºC, -50 to 100ºC 0 to 200ºC, 0 to 250ºC-50 to 200ºC 0 to 300ºC, 0 to 400ºC 0 to 600ºC 0 to 300ºC, 0 to 400ºC 0 to 600ºC, 0 to 800ºC -50 to 50ºC0 to 50ºC 0 to 100ºC, -20 to 80ºC-100 to 50ºC 0 to 150ºC, -50 to 150ºC 0 to 200ºC, 0 to 250ºC0 to 300ºC 0 to 400ºC, 0 to 500ºC0 to 600ºC -50 to 50ºC0 to 50ºC 0 to 100ºC, -20 to 80ºC-100 to 50ºC 0 to 150ºC, -50 to 150ºC 0 to 200ºC, 0 to 250ºC, 0 to 300ºC 0 to 300ºC, 0 to 400ºC, 0 to 500ºC

APPLICATION SOFTWARE (standard attached) Data Acquisition Software You can acquire data easily to your PC. *Optional communication interface required Parameter Setting Software Control the setting information at PC by using communication interface or USB port (standard equipped) List Data Screen Trend Data Screen TERMINAL ARRANGEMENT Alarm relay output(6 points a contact) + remote contacts and communication interface * RS232C and RS422A/485 are Communication terminal specified on purchase. 1 2 3 4 5 6 7 8 RS232C SG SD RD COM1 RS422A RS485 SG SDA SDB RDA RDB Short SG SA SB SA SB between 5-7, 6-8 Measurement input terminals TC.mV(+), RTD(A) terminals TC.mV(-), RTD(B) terminals RTD(B) terminals Power/protective conductive terminals Remote contact terminals (option) Alarm output terminals (option) N.O terminal COM terminal Alarm relay output(4 points c contact) + remote contacts and communication interface * RS232C and RS422A/485 are Communication terminal specified on purchase. 1 2 3 4 5 6 7 8 RS232C SG SD RD COM1 RS422A RS485 SG SDA SDB RDA RDB Short SG SA SB SA SB between 5-7, 6-8 Power/protective conductive terminals Remote contact terminals (option) Measurement input terminals TC.mV(+), RTD(A) terminals TC.mV(-), RTD(B) terminals RTD(B) terminals Alarm output terminals (option) DIMENSIONS 144 63 18 63 216max Panel cutout 200 138 1 0 144 137 12 161 200 27.2 154.4 195 12 138 1 0 *Maximum 216 when an alarm unit and a communication unit are added Unit :mm Specifications subject to change without notice. Printed in Japan (I) 2015. 6 32-8 KUMANO-CHO,ITABASHI-KU,TOKYO 173-8632 Telephone : +81-3-3956-2171 Facsimile : +81-3-3956-0915 E-mail : inter@chino.co.jp Website : www.chino.co.jp/ $